Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-Finance HOUSE NO 99 3RD FLOOR SK JAIN BUILDING KALIBARI ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L1 | Accepted-Finance Bid value/rates are reasonable | |
| 2 | L2₹29.1 L+₹2.3 L (8.74%)Rejected-Finance RAM JANAKI THAKURBARI J T ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | NAGALAND | 797112 | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹30.7 L+₹4.0 L (15.0%)Rejected-Finance | L3 | Rejected-Finance Higher bid value |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
23 Nov 2019, 6:00 pmClosed
GE 868 EWS
GE 868 EWS, PIN-913868, C/O 99 APO
REPAIR/REPLACEMENT OF INTERNAL WIRING, SUB MAIN, REPAIR OF CEILING FANS, GEYSERS AND REPAIR/MAINT OF STREET LIGHTS AND PERIMETER SECURITY LIGHTS ETC AT RAJABARI , DIMAPUR.
2019_MES_290781_1
8137/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Rangapahar
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
GE 868 EWS
₹54,000
Yes
13 Feb 2020
19 Oct 2019
25 Nov 2019
19 Oct 2019
23 Nov 2019
15 Nov 2019
19 Oct 2019 - 22 Oct 2019
Amount
Taking down existing street / perimeter light fittings from pole and alike of any wattage replacement the burnt or wornout parts. Cable twin core and alike Refixing the same fitting in its original position complete all as specified and directed by Engr-in-Charge Note:- (i) Necessary componets which are required for repairs of fittings and items measured will be paid under supply items only
Supply only 4 sqmm twin core aluminium conductor PVC insulated and PVC sheathed complete all as specified and directed by Engr-in-Charge
Supply only 6 sqmm twin core aluminium conductor PVC insulated and PVC sheathed complete all as specified and directed by Engr-in-Charge
Supply only electronic ballast capacity 2x24 Watts suitable for 2x24 Watt T-5 fitting complete all as specified and directed by Engr-in-Charge. Make:Havells /Philips/Bajaj.
Supply only T-5 Lamp 24 Watt complete all as specified and directed by Engr-in-Charge. Make : Havells /CG/Bajaj.
Supply only Lamp Holder suitable for 24 Watts T-5 Lamps as directed complete all as specified and directed by Engr-in-Charge. Make : As per Sample
S&F energy saving envirnmental friendly die-cast aluminium IP-66 LED Street light fitting of capacity 15 Watts with high power LEDs suitable for single phase 50 Hz AC including twin core aluminium conductor cable for connection from light fitting and replacement of GI bracket with clamp & Nuts bolts taking down old unsv HPSV/FTL flood lights complete all as specified and directed by Engr-in-Charge. Make : Havells /Phillips/Bajaj
S&F energy saving envirnmental friendly die-cast aluminium IP-66 LED Street light fitting of capacity 20 Watts with high power LEDs suitable for single phase 50 Hz AC including twin core aluminium conductor cable for connection from light fitting and replacement of GI bracket with clamp & Nuts bolts taking down old unsv HPSV/FTL flood lights complete all as specified and directed by Engr-in-Charge. Make : Havells /Phillips/Bajaj
S&F energy saving envirnmental friendly die-cast aluminium IP-66 LED Street light fitting of capacity 25 Watts with high power LEDs suitable for single phase 50 Hz AC including twin core aluminium conductor cable for connection from light fitting and replacement of GI bracket with clamp & Nuts bolts taking down old unsv HPSV/FTL flood lights complete all as specified and directed by Engr-in-Charge. Make : Havells /Phillips/Bajaj
S&F energy saving envirnmental friendly die-cast aluminium IP-66 LED Street light fitting of capacity 30 Watts with high power LEDs suitable for single phase 50 Hz AC including twin core aluminium conductor cable for connection from light fitting and replacement of GI bracket with clamp & Nuts bolts taking down old unsv HPSV/FTL flood lightscomplete all as specified and directed by Engr-in-Charge. Make : Havells /Phillips/Bajaj
S&F energy saving envirnmental friendly die-cast aluminium IP-66 LED Street light fitting of capacity 35 Watts with high power LEDs suitable for single phase 50 Hz AC including twin core aluminium conductor cable for connection from light fitting and replacement of GI bracket with clamp & Nuts bolts taking down old unsv HPSV/FTL flood lights complete all as specified and directed by Engr-in-Charge. Make : Havells /Phillips/Bajaj
S&F energy saving envirnmental friendly die-cast aluminium IP-66 LED Street light fitting of capacity 40 Watts with high power LEDs suitable for single phase 50 Hz AC including twin core aluminium conductor cable for connection from light fitting and replacement of GI bracket with clamp & Nuts bolts taking down old unsv HPSV/FTL flood lightscomplete all as specified and directed by Engr-in-Charge. Make : Havells /Phillips/Bajaj
S&F energy saving envirnmental friendly die-cast aluminium IP-66 LED Street light fitting of capacity 45 Watts with high power LEDs suitable for single phase 50 Hz AC including twin core aluminium conductor cable for connection from light fitting and replacement of GI bracket with clamp & Nuts bolts taking down old unsv HPSV/FTL flood lights complete all as specified and directed by Engr-in-Charge. Make : Havells /Phillips/Bajaj
S&F energy saving envirnmental friendly die-cast aluminium IP-66 LED Street light fitting of capacity 48 Watts with high power LEDs suitable for single phase 50 Hz AC including twin core aluminium conductor cable for connection from light fitting and replacement of GI bracket with clamp & Nuts bolts taking down old unsv HPSV/FTL flood lights complete all as specified and directed by Engr-in-Charge. Make : Havells /Phillips/Bajaj
S&F in repairs GI bracket 32 mm dia, medium grade pipe 1.2 m long bent to 120 degree angle with MS, nuts, bolts and washers etc complete all as specified and directed by Engr-in-Charge
S&F in repairs on wall / on pole GI bracket 25 mm dia, medium grade pipe 1.2 m long bent to 120 degree angle with MS, nuts, bolts and washers etc complete all as specified and directed by Engr-in-Charge
S&F in repairs junction box FRP 30x25x12.5 cm with connector 1 phase supply incl MCB SP 6 Amp 10 KA complete all as specified and directed by Engr-in-Charge.
S & F in repair install, testing and commissioning of street light controller panel Tent roof factory made powder coated out of 3 mm thick CRCA sheet of size 0.75x0.75x0.3 Mtr mounted on angle iron frame with front openable, lockable / operatable by keys louvers & air vent gasket to accommodate incommer / outgoing MCCBs and TPN aluminium bus bar of rating not less than the 1.5 times the rated capacity & the inner side of panel box will be painted with 2 coats of Synthetic enamel paint over a coat of red oxide primer. fixed on legs 40 x 40 x 6mm will be 0.75 m long of which 0.3 m will be below GL and 0.45 m above GL incl fixing of angle with PCC 1:4:8 D2 & earthwork complete all as specified and directed by Engr-in-Charge. Following components shall be fixed in panel box:- (a) MCB SPN 25 Amps-01 No (Incoming) (b) MCB SPN 25 Amps-01 No (Outgoing ) (c) Contactor 25 Amps-01 No (d) Timer for street light (24 Hrs) 63 Amps -01 No
Earthing complete with galvanised steel earth plate electrode60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm as earth lead and connected by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part - I 2009 including necessary earth work and PCC (1:2:4) pit including charcoal and common salt GI pipe 20mm dia light grade with 40 mm funnel with wire mesh , connected to earthing test point all as specified or indicated including testing on completion incl earthwork and PCC complete all as specified and directed by Engr-in-Charge
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5m in depth for layiung of water supply pipe line etc n exc 10 Sqm on plan and getting out soft/loose soil complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Removing ex avated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for fine river sand of approved quality cushioning for cable protection all as required at site complete all as specified and directed by Engr-in-Charge
M&L for bricks of standered size 230x110x75 mm for cable portection class -B complete all as specified and directed by Engr-in-Charge
M& L for GI tubing 50 mm dia light grade for cable protection complete all as specified and directed by Engr-in-Charge
Taking down unserviceable LT UG cable any size / any type complete all as specified and directed by Engr-in-Charge.
Supply and laying connecting and testing in repairs XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable with aluminium conductor 1100 V grade cross sectional area 25 Sq mm 4 corecomplete all as specified and directed by Engr-in-Charge. Note: Earthwork, cable cover & sand cushioning will be measured and paid separately
Supply and laying connecting and testing in repairs XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable with aluminium conductor stranded 1100V grade cross sectional area 16 Sq mm 2 core complete all as specified and directed by Engr-in-Charge. Note: Earthwork, cable cover & sand cushioning will be measured and paid separately
Supply and laying connecting and testing in repairs XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable with aluminium conductor stranded 1100V grade cross sectional area 10 Sq mm 2 core complete all as specified and directed by Engr-in-Charge. Note: Earthwork, cable cover & sand cushioning will be measured and paid separately
Earthing complete with galvanised steel earth plate electrode60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 25 X 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion incl earthwork and PCC complete all as specified and directed by Engr-in-Charge
Demolation of PCC coping , base , etc any type complete all as specified and directed by Engr-in-Charge
M & L for PCC 1:3:6 (using 20mm graded aggregate) type C 1 lintels upto 1.5m clear span, cills, steps; seismic and other similar brands, plinth courses, string courses lacing courses, parapets and railings upto 60cm in height copings, kneelers, apex stones, bed plates, kerbs not provided for, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed including form work complete all as specified and directed by Engr-in-Charge.
S&F in repair in Sheet Steel Enclosure switch disconnector fuse unit type FN (TPN) S-D-F suitable for DIN fuse -link 250 A, 415 volts complete all as specified and directed by Engr-in-Charge. Make : L&T confirming to cat No SK95618 or Havells.
S&F in repair in Sheet Steel Enclosure switch disconnector fuse unit type FN (TPN) S-D-F suitable for DIN fuse -link 200 A, 415 volts complete all as specified and directed by Engr-in-Charge. Make : L & T confirming to cat No SK95511 or Havells.
Taking out existing unsv multifunction meter from panel board S&F VAF+PF meter ,3 Phase,17-520VAC ,flush mounting 96 x 96 mm ,CT/PT site programmable ,class1,5A complete all as specified and directed by Engr-in-Charge. Make : L&T confirming to cat No WDV303FC000 or Havells.
Taking down carefully copper/aluminium point wiring (light,fan, socket or power) complete including fixture and fittings such as switches,ceiling roses,pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or fot taking credit(credit for above items should be made as per conditions separately) and making good distrubed surfaces of walls, floors etc
M&L for wiring with 1.5 sqmm size stranded FRLSH copper conductor cable single core multi stranded copper conductor in and including PVC casing capping and PVC boards with all fittings and fixing materials including multistranded insulated copper earth continuity conductor of size 1.5 Sqmm and connecting to light fittings etc all as specified and directed for following :-
(a) One light point controlled by one switch one way
(b) One fan point controlled by one switch one way
(c) One 3 pin socketoutlet 5 Amps independent board
(d) One socket outlet 5 Amps 5 pin on same board with other switch
(e) One call bell/buzzer point controlled by one push button on the same borad with other switches or independent.
All as per item No 38 here-in-before but with cable size 2.5 Sqmm for one 5 pin 15 Amps socket outlet on independent board and multistranded insulated copper earth contunuity conductor of size 1.5 Sqmm all as specified and directed by Engineer-in-Charge
M & L for switch piano type 5 Amps single pole one way
M & L forswitch socket combination 2 in 1 multi pin 5 Amps flush type universal
S & F switch socket combination multi purpose 2 in 1, 3 pin 5 & 16 Amps flush type universal
M&L for ceiling rose, surface bakelite PVC board 65 x 50mm two to three terminals.
S & F lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings
M&L for 20W LED, 4', Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver.etc with all accessories internally pre-wired and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting incl taking down old unsv light fitting complete all as specified and as directed. (100 tube lights additional for replace only )
M&L for Building security light 20W LED, bracket mounted 25 mm L shape one mtr length ,, extruded alumintreet light ium heat sink provided for efficient heat dissipation & integrated electronic driver.etc with all accessories internally pre-wired and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting incl taking down old unsv light fitting complete all as specified and as directed. (100 tube lights additional for replace only )
S & F Bell AC 230 Volts single pole 240 Volts
S & F Bell push, flush type 5 Amps 240 Volts
S&F fan regulator electronic step type, 230V 50Hz complete D13
S & F MCB SPN 240 Votls 40 to 63 Amps. Make Legrand Cat No - 603255 or equivalent Make Havells/ L & T.
S & F MCB SP 6 to 32 Amps 240 V. Make Legrand Cat No - 603231-37 or equivalent Make Havells/ L & T.
S & F for Isolator TPN 100 Amps 415 Volts. Make Legrand Cat No - 604017 or equivalent Make Havells/ L & T.
S & F MCB DB Single pole and neutral 8 way sheet steel phospetised powder painted with 200 amps rated bus bar 240 V nautral link, earth bar and Din rail double door. Make Legrand Cat No - 607711 or equivalent Make Havells/ L & T.
S & F MCB DB Single pole and neutral 4 way sheet steel phospetised powder painted with 200 amps rated bus bar 240 V nautral link, earth bar and Din rail double door. Make Legrand Cat No - 607710 or equivalent Make Havells/ L & T.
S & F MCB DB Triple pole and neutral 6 way sheet steel phospetised powder painted with 200 amps rated bus bar 415 V nautral link, earth bar and Din rail single door. Make Legrand Cat No - 607706 or equivalent Make Havells/ L & T.
S & F for Sheet metal enclosure SPN wth a two pin and earth plug and socket complete with one single pole MCB 40 Amps 240 Volts
Taking down existing unserviceable tube light fitting and repair and replace unserviceable items like electronic chock,tube rod and holders as requird and after same tube light complete set fixed on same location as per direction .
M & L for sub main wiring with 2 single core 4 sqmm copper conductor (multistrandered) including PVC casing caping PVC board with all fitting including 2.5 sqmm copper conductor as earth continuity & taking down old UNSV cable all as directed. Make - ANCHOR/PLAZZA/ RICHA/ HAVELLS/RR Kable.
Sunpply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart incl 4mm suspension wire one twin core cable flat or circular 10 sqmm 2 core stranded conductor incl taking down old UNSV one all as directed and specified by Engr-in-Charge. Make - ANCHOR/PLAZZA/ RICHA/ HAVELLS/RR Kable.
Dismantling the ceiling fan and its allied smaller parts and taking out the bearings/bushes and refixing the same with all parts i.e. down rod, canopies, fan blades etc. damaged split pins and screw, nuts and spring washers (for blade/body) as required complete all as directed.
Dismantling and taking out burnt copper winding from ceiling fan of sweep 1200mm any make, model, type and rewinding the same with new super enameled copper wire of similar gauge and number of turns as exists for full speed, including cleaning and greasing of bearing/bushes, taping, varnishing, heating and replacement of defective parts and reassembling of fan motor and refixing the fan after testing complete to the entire satisfaction of the Engr-in-Charge. Note:-Spare parts shall be measured and paid under respective items of Sch 'A'.
All as per item No above but ceiling fan of sweep 1400mm
All as as per item No above but wall cabin fan/table fan of sweep 400 of any model and type
All as per item No here-in-before but for exhaust fan of 450mm sweep, make, model and type
All as per item No here-in-before but for exhaust fan of 300mm sweep, make, model and type
Preparation of old painted surface of ceiling fan of any sweep, model and make by using chemicals, wire bush, etc to make smooth surface and apply two coats of synthetic enamel paint (first quality) by spraying similar to existing colour of the ceiling fan, motor, blades (set of 3), down rod etc including re-wiriting the MES Number with black paint complete all as directed by Engr-in-Charge
Supply & Fixing following items for ceiling fan, table fan and exhaust fan of any sweep, make, model and type all as specified and directed by the Engr-in-Charge
Fan capacitor of capacity 2.5 MFD all as specified and directed by the Engr-in-Charge Make: Universal/Usha
Fan capacitor of capacity 4.0 MFD (Oil filled) all as specified and directed by the Engr-in-Charge Make Universal/ Usha.
Ball bearing suitable for ceiling fan, of any sweep all as specified and directed by the Engr-in-Charge. Make of bearing-TATA,NBC,SKF (6201to 6204)
Bush bearing suitable for ceiling fan, pedestal fan of any sweep of approved make, model all as specified and directed by the Engr-in-Charge
Fan clamp MS including nut, bolt, rubber reel, split pin complete of suitable size 1200/1400 mm all as specified and directed by the Engr-in-Charge
Flexible wire, copper conductor, twin core, twisted type of size 23/0.0076 mm all as specified and directed by the Engr-in-Charge. Make Plaza/Payal
Top/bottom canopy suitable for ceiling fan of any sweep, make, model and type set of two all as specified and directed by the Engr-in-Charge
Rubber reel small/big size all as specified and directed by the Engr-in-Charge
Down rod made out of GI tubing medium grade with both side thread & hole of 15mm two feet long all as specified and directed by the Engr-in-Charge
Armature including magnatic ring with shaft suitable for ceiling fan of any type/make and model all as specified and directed by the Engr-in-Charge
Taking down Gysers 25 to 50 Ltrs cap from verious unit OTM accn and md accn and Re-Fixing after repair work as same location. (Including repair and maintenance of gyser work if required any replace of material it shall be measure and paid by seprately) all as specified and directed by the Engr-in-Charge
M/L heating element 1.5 KW as per IS and reported coy all as specified and directed by the Engr-in-Charge
M/L heating element 2 KW as per IS and reported coy all as specified and directed by the Engr-in-Charge
M/L thermostate suitable for 25/50 Ltrs Gyser cap all as specified and directed by the Engr-in-Charge.
Supply, laying, connecting and testing XLPE insulated (Earthed) cable in trenches/ or fixed on pole etc. in screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 volt grade, cross sectional area 35 Sqmm 3.5 Core all as specified and directed by the Engr-in-Charge. (Note: Excavation & earth work shall be measured and paid separately under relavant item of schedule)
Ditto all as per item No. 72 above, but size of cable 50 sqmm 3.5 core all as specified and directed by the Engr-in-Charge
SHRI BANARSI PRASAD
das enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .