| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC | L1 | Accepted-AOC Award of Contract | |
| 2 | L2₹36.5 L+₹1.6 L (4.54%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹38.7 L+₹3.8 L (10.9%)Rejected-Finance 4 94D RAJA COTTAGE 1ST FLOOR KANYAKULAM PARVATHIPURAM NAGERCOIL KANNIYAKUMARI TAMILNADU 629 003 | KANNIYAKUMARI | TAMIL NADU | 629003 | L3 | Rejected-Finance NOT BEING L1 |
| Sl No | Description | Qty | Unit | SREE CONSTRUCTIONS L2 | NRN GROUP L1 | ADR ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for servicing of Air cooled type AC plant unit of capacity 4x11 TR at site including cleaning of cooling coils , insulation of suction and discharge line , oiling , greasing of blower motor , checking of electricals circuit supply , air handling unit , pressure meter , greasing bearings and taking out the dust and mud complete and replacement of defective filter , relay capacitor over load protector etc as required , rewiring if necessary complete all as specified and directed by Engr in Charge.
Note :- Cost of pipe insulation , minor spares like , tape sealants , nut bolts flexible control wires etc and other T&P reqd for job is deemed to be included in quoted rates . Remaining unserviceable items if any will be measured and paid seperately. | 1 | Each Job | 7,500 ₹7,500 | 6,050 ₹6,050 Lowest | 7,500 ₹7,500 |
| 2.00 | S&F filter drier with flared/soldered connection as per sample complete all as specified and directed by Engr in Charge. | 2 | Each | 750 ₹1,500 Lowest | 800 ₹1,600 | 750 ₹1,500 Lowest |
| 3.00 | M&L in replacement of aire filter of AHU as per sample made of suitable filter with efficeiny not less than 90% class 1 to 10 micron , matching with existing sample complete all as specified and directed by Engr in Charge. | 3 | Each | 3,000 ₹9,000 | 3,500 ₹10,500 | 2,800 ₹8,400 Lowest |
| 4.00 | M&L in replacement for duct insulation with 25mm thick fiber glasses and covered with polythene sheet & chicken wire mesh or with 9mm thick nitrile sheet to duct where ever exposed to unconditional space complete all as specified and directed by engr in Charge. | 3 | Sqm | 2,100 ₹6,300 | 1,400 ₹4,200 Lowest | 2,000 ₹6,000 |
| 5.00 | Supply and fixing in replacement air grills/diffusers fabricated out of powder coated extruded aluminium sections including bird screen/VCD etc as per sample complete all as specified and directed by engr in Charge. | 3 | Each | 4,400 ₹13,200 | 2,800 ₹8,400 Lowest | 4,000 ₹12,000 |
| 6.00 | Supply anfd fixing in replacement of by pass safety valve for AC plant of capacity up to 11x4TR as per sample complete all as specified and directed by Engr in Charge. | 2 | Each | 760 ₹1,520 | 550 ₹1,100 Lowest | 700 ₹1,400 |
| 7.00 | Supply and fixing in replacement HP/LP cut out complete all as specified and directed by engr in Charge. | 2 | Each | 2,000 ₹4,000 | 1,500 ₹3,000 Lowest | 1,800 ₹3,600 |
| 8.00 | Supply and fixing of thermostatic expansion valve suitable for Pakage type AC plant of capacity 11x4TR complete and all as specified and directed by Engr in Charge. | 2 | Each | 11,000 ₹22,000 | 7,100 ₹14,200 Lowest | 12,000 ₹24,000 |
| 9.00 | M&L for replacement pilot control solenoid coil suitable for AC plant matching with existing ample complete all as specified and directed by Engr in Charge. | 2 | Each | 1,450 ₹2,900 | 850 ₹1,700 Lowest | 1,300 ₹2,600 |
| 10.00 | Supply and fixing in replacement of power contactor of suitable rating three pole 415 volts complete all as specified and directed by engr in Charge. | 2 | Each | 4,000 ₹8,000 | 2,650 ₹5,300 Lowest | 3,800 ₹7,600 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
17 Nov 2025, 6:00 pmClosed
GE(S)BANGALORE
GE(S)BANGALORE
REPAIR/ MAINT OF SUMMER APPLIANCES, PACKAGE TYPE AC PLANT AND REPAIR/ MAINT OF LT DISTRIBUTION SYSTEM FOR ZONE F, G, H AND LT PANELS SWITCH GEARS, FEEDER PILLARS AND OTHER CONNECTED ITEMS UNDER GE (SOUTH) BANGALORE.
2025_MES_736845_1
8962/E8
Open Tender
Civil Works
Item Rate
270 days
BANGALORE
AS PER NIT
6 documents required · 6 mandatory
₹500
GE(S)BANGALORE
₹86,000
Yes
27 Jan 2026
25 Oct 2025
19 Nov 2025
25 Oct 2025
17 Nov 2025
10 Nov 2025
Amount
M&L for servicing of Air cooled type AC plant unit of capacity 4x11 TR at site including cleaning of cooling coils , insulation of suction and discharge line , oiling , greasing of blower motor , checking of electricals circuit supply , air handling unit , pressure meter , greasing bearings and taking out the dust and mud complete and replacement of defective filter , relay capacitor over load protector etc as required , rewiring if necessary complete all as specified and directed by Engr in Charge. Note :- Cost of pipe insulation , minor spares like , tape sealants , nut bolts flexible control wires etc and other T&P reqd for job is deemed to be included in quoted rates . Remaining unserviceable items if any will be measured and paid seperately.
S&F filter drier with flared/soldered connection as per sample complete all as specified and directed by Engr in Charge.
M&L in replacement of aire filter of AHU as per sample made of suitable filter with efficeiny not less than 90% class 1 to 10 micron , matching with existing sample complete all as specified and directed by Engr in Charge.
M&L in replacement for duct insulation with 25mm thick fiber glasses and covered with polythene sheet & chicken wire mesh or with 9mm thick nitrile sheet to duct where ever exposed to unconditional space complete all as specified and directed by engr in Charge.
Supply and fixing in replacement air grills/diffusers fabricated out of powder coated extruded aluminium sections including bird screen/VCD etc as per sample complete all as specified and directed by engr in Charge.
Supply anfd fixing in replacement of by pass safety valve for AC plant of capacity up to 11x4TR as per sample complete all as specified and directed by Engr in Charge.
Supply and fixing in replacement HP/LP cut out complete all as specified and directed by engr in Charge.
Supply and fixing of thermostatic expansion valve suitable for Pakage type AC plant of capacity 11x4TR complete and all as specified and directed by Engr in Charge.
M&L for replacement pilot control solenoid coil suitable for AC plant matching with existing ample complete all as specified and directed by Engr in Charge.
Supply and fixing in replacement of power contactor of suitable rating three pole 415 volts complete all as specified and directed by engr in Charge.
All as per item No 11 above but for control contactor complete all as specified and directed .
S&F in replacement controller circuit board for Air cooled AC plant of capacity up to 11 TR as per existing sample complete all as specified and directed by Engr in Charge.
Supply and charging of gas R407/410/134a/R32/R22/R12 to AC plant /split AC/ window AC /cooling appliances to maintain adequate gas pressure and seal the leakage of the unit if found leakage before chargeing the gas complete all as specified and directed by Engr in Charge.
Servicing of the following Window/Split ACs/Water cooler/Refrigerator/ Deep freezer of different capacities alongwith connected voltage stablizer by carrying out periodical maintenance including cleaning with compressed air to cooling coils, condenser,water wash to the internal cabin, leak testing of refrigerant pipes and arresting leakage if any and carrying out all sort of minor repairs as required ie, checking of the complete wiring,replacement of perished wires and reconnect complete all as specified and as directed. Note : - Cost of major spares ie, rewinding /replacement of condensor fan motors,capacitors compressor,blower fan, refrigerant copper tubing,relays, refrigerant gas etc, if required shall be measured and paid seperately under respective item of work (a) Window type AC of capacity upto 1.5 TR.
(b) Split type AC of capacity upto 3.0 TR.
(c) Water cooler of capacity upto 180 Ltrs
M&L for removing the old unserviceable hermatically sealed compressor unit from Water cooler of 40/80 &160/120 ltrs capacity and fixing new sealed unit reciprocating type hermatically sealed compressor unit as per sample including charging of gas and oil to at adequate level complete all as specified and directed by Engr-in-Charge.
All as per item No -18 here in before but suitable for water cooler 150 to 180 ltr cap.
All as per item No-18 here in before but suitable for 1.5 Ton Window/Split type AC.
All as per item No-18 here in before but suitable for above 2.0 Ton and upto 3.0 Ton Split type AC.
All as per item No -18 here in before but suitable for Refrigerator of any type.
Supply and replacement blower/condensor fan motor suitable for window/ split type AC and water cooler of any type/any size complete all as specified and as directed.
Supply and replacement condenser cooling coil including system fusing,vaccumising incl all material and labour for refrigerent gas,charging,testing and commissioning suitable for 1.5 Ton window/Split type AC complete all as specified and as directed.
All as per item No 24 here in before but suitable for above 1.5 Ton and upto 3.0 Ton Split type AC.
All as per item No 24 here in before but suitable for water cooler of any type/any size.
S&F in replacement indoor type unit of split type air conditioner 2.0 TR of existing make complete including blower, controller card, cooling coils remote control etc including testing and connection with outdoor unit complete all as specifed and directed by Engr-In-Charge.
S&F in replacement outdoor unit of split type air conditioner 2.0 TR of existing make including condensing coil, condensor motor and fan blade, hermetically sealed compressor suitable for Non CFC based Refrigerant gas, inlet outlet copper valves to connect with indoor unit and other accessories as required including testing and connection with indoor unit complete all as specifed and directed by Engr-In-Charge.
Supply and replacement cooling coil unit suitable for 1.5/2.0 Ton window/split type AC, complete all as specified and as directed.
Supply and replacement fan blade for window AC 1.5/ 2.0 Ton complete all as specified and as directed.
All as per item No 30 here in before but suitable for water cooler any type
Supply and replacement starting relay for 1.5 Ton/ 2 Ton Window /Split type AC complete all as specified and as directed.
Supply and replacement relay any type any size for water cooler, deep freezer/refrigerator complete all as specified and as directed.
Supply and replacement of push tap of same make & type chromium plated for water cooler complete all as specified and as directed.
Supply and replacement of unserviceable float valve 15mm dia for water cooler complete all as specified and as directed.
Supply and replacement of unserviceable PVC flexible inlet pipe of 16mm dia and 450mm long with brass nuts& bolts complete all as specified and as directed.
Supply and replacement of unserviceable PVC flexible outlet pipe of 32mm dia including O clip 1.5 mtr long complete all as specified and as directed.
Supply and replacement of plug top 16 Amp suitable for water cooler complete all as specified and as directed.
Supply and replacement of plug top 6 Amp suitable for Refrigerator complete all as specified and as directed.
Supply and replacement of unserviceable thermostate for refrigerator/deep freezer complete all as specified and as directed.
Supply and replacement of unserviceable over load protection for any type of refrigerator/deep freezer complete all as specified and as directed.
Supply and replacement of unserviceable stainless steel water tray basin of water cooler any type/make complete all as specified and as directed.
Supply and replacement PVC insulated cable with copper conductor size 2.5 Sqmm, single core, 1100 volt grade, complete all as specified and as directed.
Supply and replacement PVC insulated cable with copper conductor size 4.0 Sqmm, single core, 1100 volt grade, complete all as specified complete all as spd and directed.
Supply and fixing metal clad plug & socket unit enclosed in sheet metal enclosure complete with MCB SP 20 Amp complete all as specified and as directed.
Supply and replacement starting capacitor of suitable variable Mfd matching with existing sample complete all as specified and as directed.
Supply and replacement for running capacitor 4 Mfd complete all as specified and as directed.
Removing unserviceable front grill of window type AC's and replace with new grill matching with existing all as specified and as directed.
Supply and replacement insulation for refrigerant copper tubing of any size matching with existing complete all as specified and as directed
Supply and replacing refrigerant copper tubing 1/4" & 1/2" with 22 SWG seperately alongwith insulation sleeves, fixed on wall/ floor/ cealing for additional length (Required if any) as per site requirement including making joints duly brazed at ends complete all as specified and as directed.
Supply and replacing refrigerant copper tubing 3/8" & 5/8" with 22 SWG seperately alongwith insulation sleeves, fixed on wall/ floor/ cealing for additional length (Required if any) as per site requirement including making joints complete all as specified and as directed.
Supply and replacement for PCB of cooling unit of split AC 1.5/ 2.0 Ton with remote complete all as specified and as directed.
Supply & fixing in replacement of potential correction unit, with digital display and designed for input variation between 140 V to 250 V with output voltage stabilized at 230 V within tolerance limit of capacity not less than 5 KVA complete all as specified and directed by Engr-In-Charge. VGuard/BlueBird/Microtek or as approved
M&L for shifting of window/Split Air conditioner by safely removing it from existing location including making good to disturbed surfaces matching with existing and storing refrigerant gas securely and refixing the same at new location, providing proper insulation to Copper tubing and extention of existing copper tubing, providing mounting brackets for indoor and outdoor units if required including testing after shifting complete all as specifed and directed by Engr-In-Charge. Note:-(1) Rate inclusive of necessary transportation (2) Additional requirement of refrigerent copper tubing,insulation and cables during shifting shall be measured and paid seperately under respective item)
Taking down filter units from water cooler cum purifier of 80 LPH capacity and re-assemble the same after carry out necessary servicing complete all as specified and as directed.
Note: (i) Cost of spares, if required during servicing shall be measured and paid seperately under respective items
Carbon booster filter
Semi carbon cartridge
Pressure booster pump 24 volt
Silcon filter
M&L for making hole in brickwall/stone masonary for passing pipes/wires etc and making good to distrubed surfaces matching with existing , complete all as specified and directed by Engr in Charge.
M&L sub main wiring surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run of 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through concealed/ casing caping/ PVC conduit as required at site complete all as specified and as directed by Engr-In-Charge. (Note :- Two runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
M&L sub main wiring surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run of 6 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through concealed/ casing caping/ PVC conduit as required at site complete all as specified and as directed by Engr-In-Charge. (Note :- Two runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
Excavation in trenches in soft/loose soil not exceeding 1.5 M wide and not exceeding 1.5 M in depth for laying of UG cables and LT Panel board foundation etc and getting out.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil.
Removing excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 M above the starting point all as directed.
M&L for sand cushioning in trenches for bricks of u/g cable with coarse sand laid dry in trenches with uniform thickness.
Relaying of old serviceable bricks brought out from exacavation as a protection for LT Cables complete all as specified and directed by Engr-In-Charge.
Supply and lay burnt bricks of sub class 'B' laid dry across in trenches for cable protection all as specified and directed.
Taking down old unserviceable service cable 10/6 sqmm 2 core
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated multi stranded aluminum conductor, 6 Sqmm twin core served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed by Engr-In-Charge
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated multi stranded aluminum conductor, 10 Sqmm twin core served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed by Engr-In-Charge
Taking down/out unserviceable LT Cables of any Cross Sectional Area and Connections and joints including Pipes, Bricks, etc of any description laid in trenches or fixing with Walls/Poles, segreating serviceable Pipes, Cables etc and keep serviceable cable and Bricks in safe custody for reuse, complete all as specified and as directed. Note : Earthwork will be measured and paid under appropriate Items.
Taking down carefully old unserviceable UG cable of any size from the trenches/wall/pole from site after affording credit including removal of brick cable cover complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm x 2 core including thimbles at ends/strraight through ferrules as reqd for connection duly insulated including taking down unserviceable UG cable complete all as specified and directed. (Make- Havells/Polycab/Paragon/Gloster/KEI)
All as per Item No as per 75 but of size 16 Sqmm x 4 Core complete all as specified and directed by Engr-In-Charge
All as per Item No as per 75 but of size 35 Sqmm x 3.5 Core complete all as specified and directed by Engr-In-Charge
All as per Item No as per 75 but of size 70 Sqmm x 3.5 Core complete all as specified and directed by Engr-In-Charge
All as per Item No as per 75 but of size 120 Sqmm x 3.5 Core complete all as specified and directed by Engr-In-Charge
All as per Item No as per 75 but of size 185 Sqmm x 3.5 Core complete all as specified and directed by Engr-In-Charge
All as per Item No as per 75 but of size 300 Sqmm x 1 Core complete all as specified and directed by Engr-In-Charge
Labour only for Re-Laying fixing or passing through pipe only LT 1100 Volts grade cable of any size incl connections from LT panel board of any size Complete all as specified and directed by Engr-in-Charge.
M&L for Breaking road, pavement, hard standing, tiles of any type, including excavation of sub base, soil upto the depth of 0.60 mtr and width 0.45 mtr by mechanical means for fault finding in electric cables and including making good to the disturbed surfaces matching with existing after rectification of fault including removal of surplus material to nearby dumping point complete all as specified and directed by Engr-In-Charge. Note:(i) Any T&P required for work is deemed to be included in quoted rates. (ii) Tiles, cement concrete etc. required for making good is deemed to be included in quoted rates.
Dismanling old unserviceable of MCB/MCCB any type any capacity
S&F in replacement of MCCB 3/4 pole as reqd 415 volt fixed type of capacity 400 Amps with breaking capacity 36 KA Complete all as specified and as directed by Engr-In-Charge.
S&F in replacement of MCCB 3/4 pole as reqd 415 volt fixed type of capacity 250 Amps with breaking capacity 36 KA Complete all as specified and as directed by Engr-In-Charge.
S&F in replacement of MCCB 3/4 pole as reqd 415 volt fixed type of capacity 200 Amps with breaking capacity 36 KA Complete all as specified and as directed by Engr-In-Charge.
S&F in replacement of MCCB 3/4 pole as reqd 415 volt fixed type of capacity 160 Amps with breaking capacity 25 KA Complete all as specified and as directed by Engr-In-Charge.
S&F in replacement of MCCB 3/4 pole as reqd 415 volt fixed type of capacity 125 Amps with breaking capacity 16 KA Complete all as specified and as directed by Engr-In-Charge.
S&F in replacement of MCCB 3/4 pole 415 volt fixed type of capacity 100 Amps with breaking capacity 16 KA Complete all as specified and as directed by Engr-In-Charge.
S&F in replacement of MCCB 3/4 pole as reqd 415 volt fixed type of capacity 63 Amps with breaking capacity 16 KA Complete all as specified and as directed by Engr-In-Charge.
S&F in replacement of MCCB 3/4 pole as reqd 415 volt fixed type of capacity 800 Amps with breaking capacity 16 KA Complete all as specified and as directed by Engr-In-Charge.
S&F in replacement of MCB TPN 63 Amp capacity three phase 415 volt 50 Hz Complete all as specified and as directed by Engr-In-Charge.
Supply and fixing in replacement of Multifunction meter digital type suitable for displaying Voltage, Current, Power factor, Frequency and other relevant parameters of three phase four wire 415 Volts system prewired, operates on 230/415 Volts Auxiliary supply having accuracy class-1 including making provision for mounting in existing LT Panel and taking down existing complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement RYB indicator lamps set of three with mounting provision on existing panel board complete all as specified and directed by Engr-In-Charge.
S & F of Onload front /side handle change over switch of capacity 100Amp 415 volt 50 Hz 4P with encloser, handle matching with existing including taking down of unserviceable change over complete all as specified and as directed by Engr-InCharge. Make- Indoasian/havells/Legrand
S & F of Onload front/side handle change over switch of capacity 200 Amp 415 volt 50 Hz 4P with encloser, handle matching with existing including taking down of unserviceable change over complete all as specified and as directed by Engr-InCharge. Make- Indoasian/havells/Legrand
S & F of Onload front/side handle operated suitable for panel mounting change over switch of capacity 800 Amp 415 volt 50 Hz 4P with encloser, handle matching with existing including taking down of unserviceable change over complete all as specified and as directed by Engr-InCharge. Make- Indoasian/havells/Legrand
M&L for repairing of LT Panel by fixing broken hinges welding , greasing , internal MCCB/Bus bar cubicle 10nOs repairing , tightining of earthing including new hinges , locks welding /brazing , greasing including if reqd for complete LT Panel off up to size 1.7x1.2x0.4mtr Complete all as specified and as directed by Engr-In-Charge.
M&L for fixing in repair locking arrangement of external doors of LT Panel by providing proper lock proper lock mechanism , including replacement of lock if reqd at site Complete all as specified and as directed by Engr-In-Charge.
M&L for Preparaton of old surfaces for painting of existing LT Panel/feeder pillar size up to 1.7x1.2x0.4mtr by peeling existing paint layer and dust , cleaning of surface , and applying to coats of sytnhetic enamel paint of colour as decided over one coat of red oxide primer on all outdoor of LT panel including inner side of gates complete all as specified and directed by Engr-in -Charge.
Dismantling of old unserviceable LT Panel board from Site .
Dismentling of Feeder piller box of any type any size complete all as directed.
Supply and fixing in replacement LT Feeder pillar Panel board outdoor type fabricated out of 3.15mm thick CRCA Sheet steel factory made vermin proof duly painted with two coat of synthetic enamelled paint over a coat of red oxide primer or powder coated, double door, water proof dust and vermin proof hinged and lockable doors inlcuding rain protection cover on top and complete with interconnections, with copper wires, tapes, opening from both sides with cable entry from bottom,double door type with both side opening of doors with locking provision and gaskets at opening , with Aluminum bus bar chamber three phase four wire 415 Volts type of rating 300 Amps with provision for mounting of MCCB of rating upto 160 Amps,4 pole,25 KA, including Digital type Voltmeter and Ammeter, bonding to earth and painting, including angle iron frame of size minimum 40x40x6mm having 4 legs 0.60 mtr long including grouting in PCC 1:4:8, to the reqd depth including under mentioned Items all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement LT Feeder pillar Panel board outdoor type fabricated out of 3.15mm thick CRCA Sheet steel factory made vermin proof duly painted with two coat of synthetic enamelled paint over a coat of red oxide primer or powder coated, double door, water proof dust and vermin proof hinged and lockable doors inlcuding rain protection cover on top and complete with interconnections, with copper wires, tapes, opening from both sides with cable entry from bottom, with Aluminum bus bar chamber three phase four wire 415 Volts type of rating 160 Amps, 4 pole, 25KA, bonding to earth and painting, including angle iron frame of size minimum 40x40x6mm having 4 legs 0.60 mtr long including grouting in PCC 1:4:8, to the reqd depth including under mentioned Items all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts and washers made out of GI/steel earth strip protected by GI light grade pipe of 40 mm dia and connecting to main panel board/switch board/control board all shown in electrical plate No 3 of SSR Pt I incl PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10 cm center to center both ways incl earth work like excavation, returning filling back disposal etc complete.
Supply and errect swaged steel tubular poles, 9 meter long complete with cast iron base plate, finial taper plug, bolts, nuts, screws and complete with all accessories etc including excavation removal and filling in PCC 1:4:8 in foundation and 1:3:6 in coping outside and painting with stove enamelled paint over a coat of red oxide, marking no of pole and stripes at bottom of color as decided complete all as specified and as directed by Engr-In-Charge.
M&L for GI bracket for street light fittings 32mm dia 1.2Mtr length including D/C clamps for PCC/Steel pole round or square nut bolt and washers etc and painiting of bracket and clamps all as specifiedf and directed by Engr in Charge .
Material & Labour for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation, mass concrete for road crossing etc. complete all as specified and as directed by Engr-In-Charge.
Material & Labour for PCC 1:3:6 type D2 (using 20mm graded stone aggregate) as in foundation, mass concrete for road crossing etc.,complete all as specified and as directed by Engr-In-Charge.
Material & Labour for PCC 1:2:4 type B2 (using 40mm graded stone aggregate) as in foundation, mass concrete for road crossing etc. complete all as specified and as directed by Engr-In-Charge.
S&F for post insulator for fixing of aluminium strip on wall for safety purpose complete all as per specified and directed by Engr-In-Charge.
Supply and fixing Aluminium strip of size 25 x 3.15mm incl epoxy/porcelain insulators of suitable size , distance between insulators not more than 1mtr including fixing screws washers etc complete all as specified and as directed by Engr-In-Charge.
Dismantaling of old unserviceable GI Pipe of any size complete all as specified and as directed by Engr-In-Charge.
Supply and lay pipe galvanized light grade including fittings 40mm dia for cable protection using road crossing etc.
All as per Item No as per 54 above but of size 80mm dia complete all as specified and as directed by Engr-in-Charge.
Material & Labour for LT straight through joint for under ground cable for 3 ½ / 4 Core upto 50 sqmm Compete all as specified and directed by Engr-In-Charge.
All as per Item No as per 56 but of size 70 Sqmm to 95 sqmm 3.5 Core complete all as specified and directed by Engr-In-Charge.
All as per Item No as per 56 but of size 120 Sqmm to 185 sqmm 3.5 Core complete all as specified and directed by Engr-In-Charge
All as per Item No as per 56 but of size 240 Sqmm to 400 sqmm 3.5 Core complete all as specified and directed by Engr-In-Charge.
Supply and fix LED security light fittings aesthetically designed roadway luminaire with excellent thermal management complete 35/45Watt IP 66 including dismatling old one complete all as specified and directed by Engr-In-Charge.
S & F LED street light 90W made up off pressure die cast aluminium housing wth toughened glass and LEDs as a light source prewired with electronic driver suitable for 90 watts light fitting with IP 65 protection with Surge protection device for protection of LED driver, lumen efficacy of light fitting shall be not less than 100 lm/W. with necessary mounting arrangements including taking down old unserviceable light fitting.complete all as specified and directed by Engr-in-charge. Note :- Housing of street light fitting shall be suitable for 40 to 50 mm dia of bracket.
S&F in replacement PVC insulated 3 Core multistranded copper cable 1.5 Sqmm complete all as specified and directed by Engr-In-Charge.
S&F Aluminium thimbles for end termination of cables and straight through ferrules for suitable for cable size 120 Sqmm to 150 Sqmm tightned with suitable crimping tools along with connecting accessories ie nut bolt washers etc complete all as specified and directed by Engr in Charge.
All as per Item No as per 63 but size 70 to 90 Sqmm
All as per Item No as per 63 but size 25 to 50 Sqmm
All as per Item No as per 63 but size up to 16 Sqmm
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed by Engr-in-Charge.
M&L preparation of surfaces of pole for painting of steel tubular pole,vertical with one coat of aluminium paint incluing painting black and white strip or as ordered by engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering with writing letters or figures(Block), height not,exc 30 cm high & letters or figures n'exc 10 Nos complete all as directed.
M&L preparation of surfaces of pole for painting of PCC pole,vertical with one coat of cement base paint incluing painting black and white strip or as ordered by engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering with writing letters or figures(Block), height not,exc 30 cm high & letters or figures n'exc 10 Nos complete all as directed.
Supply and fixing in replacement LT Panel board outdoor type fabricated out of 3.15mm thick CRCA Sheet steel factory made vermin proof duly painted with two coat of synthetic enamelled paint over a coat of red oxide primer or powder coated, double door, water proof dust and vermin proof hinged and lockable doors inlcuding rain protection cover on top and complete with interconnections, with copper wires, tapes, opening from both sides with cable entry from bottom, with cable alley and bus bar chamber, bonding to earth and painting, including angle iron frame of size minimum 40x40x6mm having 4 legs 0.60 mtr long including grouting in PCC 1:4:8, to the reqd depth all as specified and directed by Engineer-in-Charge. INCOMING (a) MCCB 315 amps 4 pole 50 KA adjustable thermal and fixed magnetic setting - 01 No Busbar : - Aluminium busbar 3 phase 4 wire of 400 Amps supported with ebonite insulators -1set OUTGOING (b) MCCB 200 Amps 3 pole 16 KA with adjustable thermal and fixed magnetic setting – 03 Nos (c) Multifuction meter suitable to display voltage, current, frequency, power factor and other relavent parameters for three phase 4 wire 415 Volts System including three nos CTs of appropriate ratio – 01 No
Supply and fixing in replacement LT Panel board outdoor type fabricated out of 3.15mm thick CRCA Sheet steel factory made vermin proof duly painted with two coat of synthetic enamelled paint over a coat of red oxide primer or powder coated, double door, water proof dust and vermin proof hinged and lockable doors inlcuding rain protection cover on top and complete with interconnections, with copper wires, tapes, opening from both sides with cable entry from bottom, with cable alley and bus bar chamber, bonding to earth and painting, including angle iron frame of size minimum 40x40x6mm having 4 legs 0.60 mtr long including grouting in PCC 1:4:8, to the reqd depth including under mentioned Items all as specified and directed by Engineer-in-Charge. INCOMING (a) MCCB 160 amps 4 pole 25 KA fixed thermal and fixed magnetic setting - 01 No Busbar : - Aluminium busbar 3 phase 4 wire of 400 Amps supported with ebonite insulators -1set OUTGOING (b) MCCB 100 amps 3 pole 16 KA – 03 Nos (c) Multifuction meter suitable to display voltage, current, frequency, power factor and other relavent parameters for three phase 4 wire 415 Volts System including three nos CTs of appropriate ratio – 01 No (d) LED indicator RYB – 03 Nos
Supply and fixing in replacement LT Panel board outdoor type without MCCB and changeover fabricated out of 3.15mm thick CRCA Sheet steel factory made vermin proof duly painted with two coat of synthetic enamelled paint over a coat of red oxide primer or powder coated, double door, water proof dust and vermin proof hinged and lockable doors inlcuding rain protection cover on top and complete with interconnections, with copper wires, tapes, opening from both sides with cable entry from bottom, with cable alley and bus bar chamber, bonding to earth and painting, including angle iron frame of size minimum 40x40x6mm having 4 legs 0.60 mtr long including grouting in PCC 1:4:8, to the reqd depth suitable for mentioned Items including multifunction meter, bus bars, LED induction all as specified and directed by Engineer-in-Charge. Note:(Quoted rates are deemed to be included for multifunction meter, bus bar, 4 LED indicator, MCCB and changeover will be mentioned and paid separately under respective work. INCOMING (a) MCCB 800 amps 4 pole 50 KA fixed thermal and fixed magnetic setting - 02 No Busbar : - Aluminium busbar 3 phase 4 wire of 400 Amps supported with ebonite insulators -1set OUTGOING (b) MCCB 800 Amps Changeover 3 pole 16 KA – 01 Nos (c) Multifuction meter suitable to display voltage, current, frequency, power factor and other relavent parameters for three phase 4 wire 415 Volts System including three nos CTs of appropriate ratio – 01 No (d) LED indicator RYB – 03 Nos
Supply and fixing in replacement LT Panel board outdoor type fabricated out of 3.15mm thick CRCA Sheet steel factory made vermin proof duly painted with two coat of synthetic enamelled paint over a coat of red oxide primer or powder coated, double door, water proof dust and vermin proof hinged and lockable doors inlcuding rain protection cover on top and complete with interconnections, with copper wires, tapes, opening from both sides with cable entry from bottom, with cable alley and bus bar chamber, bonding to earth and painting, including angle iron frame of size minimum 40x40x6mm having 4 legs 0.60 mtr long including grouting in PCC 1:4:8, to the reqd depth including under mentioned Items all as specified and directed by Engineer-in-Charge. INCOMING (a) MCCB 400 amps 4 pole 50 KA fixed thermal and fixed magnetic setting - 01 No Busbar : - Aluminium busbar 3 phase 4 wire of 400 Amps supported with ebonite insulators -1set OUTGOING (b) MCCB 400 Amps 4 pole 16 KA – 01 Nos (c) MCCB 100 amps 3 pole 16 KA-1 Nos (d) MCCB 32 amps 3 pole 16 KA-03 Nos (e) MCCB 25 amps 3 pole 16 KA-05 Nos (f) MCCB 10 amps 3 pole 16 KA-03 Nos (g) Multifuction meter suitable to display voltage, current, frequency, power factor and other relavent parameters for three phase 4 wire 415 Volts System including three nos CTs of appropriate ratio – 01 No (h) LED indicator RYB – 03 Nos
Supply and fixing in replacement LT Panel board outdoor type fabricated out of 3.15mm thick CRCA Sheet steel factory made vermin proof duly painted with two coat of synthetic enamelled paint over a coat of red oxide primer or powder coated, double door, water proof dust and vermin proof hinged and lockable doors inlcuding rain protection cover on top and complete with interconnections, with copper wires, tapes, opening from both sides with cable entry from bottom, with cable alley and bus bar chamber, bonding to earth and painting, including angle iron frame of size minimum 40x40x6mm having 4 legs 0.60 mtr long including grouting in PCC 1:4:8, to the reqd depth including under mentioned Items all as specified and directed by Engineer-in-Charge. INCOMING (a) MCCB 250 amps 4 pole 50 KA fixed thermal and fixed magnetic setting - 01 No Busbar : - Aluminium busbar 3 phase 4 wire of 400 Amps supported with ebonite insulators -1set OUTGOING (b) MCCB 160 Amps 3 pole 16 KA – 03 Nos (c) MCCB 100 amps 3 pole 16 KA-03 Nos (d) Multifuction meter suitable to display voltage, current, frequency, power factor and other relavent parameters for three phase 4 wire 415 Volts System including three nos CTs of appropriate ratio – 01 No (e) LED indicator RYB – 03 Nos
SREE CONSTRUCTIONS (BID ID -3475643)
ADR ENTERPRISES (BID ID -3481110)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
Tenderdocument8962.pdf
Tender Documents • 0.87 MB
BOQ_825041.xls
BOQ • 5.74 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .