Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-Finance | L1 | Accepted-Finance Being Lowest Tenderer | |
| 2 | L2₹39.3 L+₹4.3 L (12.4%)Rejected-Finance | L2 | Rejected-Finance Being other than Lowest Tenderer | |
| 3 | L3₹40.9 L+₹6.0 L (17.1%)Rejected-Finance | L3 | Rejected-Finance Being other than Lowest Tenderer | |
| 4 | L4₹42.9 L+₹7.9 L (22.7%)Rejected-Finance B BLOCK 2 3 RAM BACHAN V B NAGAR PIPE ROAD KURLA W MUMBAI 400070 | MUMBAI SUBURBAN | MAHARASHTRA | 400070 | L4 | Rejected-Finance Being other than Lowest Tenderer |
Tender Value
₹47.1 L
EMD Value
₹94,000
Closing Date
20 Nov 2023, 6:55 pmClosed
Lt Col Ng Rajesh Singh GE NW KUNJALI
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8974 SPECIAL REPAIRS TO ROOF AND PARAPET WALL OF NMRL DGQA BUILDING AT NAVAL DOCKYARD MUMBAI AND ADDN ALTN OF SHAFT OF SINGLE LIVING ACCN AT INS ANGRE UNDER GE NW KUNJALI
2023_MES_626305_1
8974/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
All as per tender documents
6 documents required · 6 mandatory
₹0
₹94,000
Yes
11 Dec 2023
2 Nov 2023
22 Nov 2023
5 Nov 2023
20 Nov 2023
6 Nov 2023
2 Nov 2023 - 5 Nov 2023
Amount
Taking down PVC wastage and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, complete all as specified and as directed
S&F sand cast type 100 mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors all as specified.
Taking down cement plaster on brick / surfaces built in cement mortar including raking out joints, bading for key scrubbing down with water etc complete.
Taking down chowkats or frame with shutter ( without taking off shutter from frame) , n exc 1.5 sqm each complete all as specified.
Taking down chowkats or frame with shutter ( without taking off shutter from frame) exc 1.5 sqm but n exc 4 Sqm each complete all as specified.
Taking down 15mm bore, GI tubing and connections including cleaning for refixing or removal to store.
All as per item No 6 above but 20 mm bore GI Pipe.
Providing plain cement concrete type B-1, 1:2:4 (using 20 mm graded stone agg) as in lintels upto 1.5 M clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stones, bed plates, bed blocks, roof kerbs water troughs and the like including weathering slightly rounded or chamfered angles and throating complete all as specified and as directed
Dismantling of cast iron or reinforced concrete drain pipes of 100mm dia fixed to wall and taking out from trenches all as directed.
S&F sand cast type 100 mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, but fixed to walls all as specified.
S&F sand cast type 75 mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, but fixed to walls all as specified.
S&F in repairs 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) all as specified.
S&F in repairs 75 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) all as specified.
S&F in repairs 75 mm bore cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) all as specified.
S&F 160mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including fixing clips, bends, elbows, shoes etc complete all as specified and as directed by EIC.
S&F 110mm dia bore PVC (SWR) bends any radius complete all as specified and as directed
S&F 160mm dia bore PVC (SWR) bends any radius complete all as specified and as directed
S&F 110mm dia bore PVC (SWR) (T/Y) any radius complete all as specified and as directed
S&F 160mm dia bore PVC (SWR) (T/Y) bends any radius complete all as specified and as directed
Removing Bldg Material exc 1.5 Km but n.exc 15 Km and deposited where as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and disposing off complete all as specified and as directed
M&L brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:6 all as specified.
M&L for brick work with sub class 'B' bricks , straight or curved on plan to any radius in half brick thick wall built in cm 1:4.
Supply only integral water proofing compound complete all as specified and as directed
M & L for Pre cast Cement concrete block masonary (type B1 1:2:4 20 mm graded aggregate) with solid blocks exc 10 cm in width and setting in CM (1:6)
S & F Powder coated aluminium frame for doors, windows, ventilators and partitions with one or more rebates including joining cleat for fixing etc. complete shall as specified.
Supply & fix aluminium anodised grill (minimum thickness of anodising 15 micron) with and including suitable aluminium anodized 'F'/'H' section frame as required with aluminium rebated/screwed attachment complete all as specified and directed complete all as specified and directed. Note:- Aluminium grill shall be of Deco grill of M/s ELESAR FOCCHI Ltd as per Design No DG 102, 7.50mm x 6.0mm and weight shall not be less than 3.131Kg/Sqm or approved design in M/s Royal Grill/National Grill/Allumigrille of M/s Alumi Profies Pvt Ltd, Chandramukhi Basement, Nariman Point, Mumbai
S&F 4mm thick backelite with decoratve choice laminated on both side complition as specified and as directed
S&F 4.8mm thick sheet glass froasted or obscured one side and glazing with oil putty or wooden beads in square area n.exc 0.5 Sqm in each pane complete all as specified and as directed
S & F 100 mm Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type B-11.
S&F Aluminium anodised sliding door bolt 300m long, with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy .
S&F aluminium anodised Barrel tower bolts of extruded section, length of bolt 200mm.
S&F Extrude aluminium anodised alloy handles, fabricated type 150mm size.
M & L for Floor door stopper of aluminium alloy body 140 mm long and tongue, anodised, with hard drawn steel spring, fixed in floor.
Cement concrete 25 mm thickType B1 1:2:4 (20 mm graded aggregate)
S&F in repair aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel stapple etc.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and disposing the rubbish to the out side of MD land
M&L for coloured glazed ceramic tiles 450x300x7 mm thick but as on vertical surfaces such as skirting/dado including 10mm thick rendering in CM 1:3.
M&L double charge premium quality virified ceramic light shade tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match in floor including 15 mm thick screed bed or bedding layer for laying floor finishes in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match.
M&L double charge premium quality vitrified ceramic light shade tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36sqm (600x600mm),but as on vertical surfaces such as skirting/dado including 10mm thick rendering in CM1:3 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match.
M&L 20 mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills,cooking platforms, working table and like over 20 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed
S&F 15 mm dia medium grade galvanized steel tubing with all fittings fixed to walls, ceilings or laid under floors all as specified and directed complete all as specified and as directed.
As per item No 44 above but 20mm dia medium GI Pipe
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof covering.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
S&F roof trusses (framed), trussed, purlins,crane gantries, rails and fastnings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.conforming to Fe 410-W (Gde- E-250) quality-B complete all as specified .
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of Fe 410-W ( Gde-E-250 quality-A).
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, chajjas, valley gutter, ridge and fixed with crumple joint etc fixed with self tapping screws as specified.
M & L for preparation of new steel surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed .
S&F 1mm thick Plain, galvanised, mild steel sheeting in valley gutters, eaves, hips, drip and straight flashing (length and girth as fixed) with grade of zinc coating 275 complete all as specified & directed.
Surface excavation in hard/dense soil n exc30cm deep and averaging 15cm deep getting out, and making good surface complete all as specified and directed
M & L hardcore of guage not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to true surfaces (broken stone or boulders).
M&L for 100 mm thick cement concrete 1:4:8 type D-2 (40 mm graded stone agg) as in sub base.
M&L for machine pressed precast concrete inter locking paver block any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 Grade, glossy finished of approved colour laid over and including 25 mm thick fine sand cushion to a line and slope etc and joined complete including spreading screened river sand over surface for filling the joints with rising surface vibrator etc complete all as specified . Make :- NITCO/VITCO.
Demolition of brick bats, terracing tiles, etc on roofs and removing the same to store from terrace of high rise bldg etc complete all as specified and directed.
M&L for roughening surfaces of old concrete surfaces by picking, sweeping cleaning and washing down with water to remove dust etc including taking down tarfelt and 15mm thick screeding in cement mortar 1:4 finishes even and smooth using extra cement including mixed with water proofing compound as per manufacturer instructions (WPC shall be measured and paid separately).
M&L for PCC 1:2:4 type B-0(using 12.5mm graded aggregate) cement concrete as a levelling course on roof surfaces and coping etc complete all as specified and directed.
The Water Proofing Treatment shall be four course and shall be carried out as follows :- (a) Apply a coat of oil based bituminous primer @ 200 gms/ sqm on the prepared surfaces. (b) Apply a coat of blown type bitumen grade 85/25 confirming to IS: 702 heated to a working temperature of 180 degree C and applied @ 1.2 Kg/ Sqm the surface area. (c) Provide and lay 4mm thick APP modified torch applied water proofing membrane weighing not less than 4.00 Kg per Sqm reinforced with non woven polyster matt, weighing not less than 160 gm/ Sqm having softening point not less than 140 defree C, Longitudinal tensile strength not less than 650 N/5 CM, tear strength of 180N (Min), a static puncture resistance of 180, keeping a minimum of 10 cm over laps and 15 cm end lap. (d) Removing of existing water proofing treatment complete all as specified and directed by EIC. The APP membrane shall be taken upto minimum 200mm on vertical surfaces. the edge of the membrane shall be sealed with sealant. The rain water gutter portion shall be finished with cement mortar 1:4 to provide requisite slop towards rain water pipe outlet . NOTE : (i) Irrespective of lap the net covered area shall only be measured and paid. (ii) The quoted rate shall be deemed to be inclusive of primer for APP membrane and SBR latex complete.
M&L for machine pressed pavers terracotta (coloured) cement tiles of size 300mm x 300mm x 22 mm thick mix with grey cement and pigment laid over 20mm thick screed bed in CM 1:4 set and jointed and pointed in neat cement slurry in floors complete all as specified and direcetd.
S & F in repairs single piece WC with UF Soft close slim seat cover fixing accessories, accessories set and cistern fitting incl trap/connecting piece complete all as specified and directed. (Make-Jaquar)
S & F in repairs white vitreous china squatting pan, 'Orissa' pattern, water closet of size 580x440mm with integral foot rest, P/S trap etc, fixed in repair complete all as specified and directed by Engr-in-Charge.
S&F in repairs10 litres capacity PVC low level flushing cistern of approved make including ball valve,syphon set, inlet and outlet pipe, brackets etc. complete all as specified and directed by Engr-in-Charge.
S & F in repair for health faucet ( Jet) 1 m long PVC tube with wall hook chromium plated fitted to stopcock 15 mm bore complete all as specified and directed by Engr-in-Charge.
S&F counter top wash hand basin incl chromium plated brass waste coupling and PVC waste pipe complete all as directed Make _ Jaquar/ Hindware/ Cera.
S&F in repairs CP bib cock 15 mm bore (Make Jaquar CAT PART NO- FLR-5047N) all as specified and directed.
S&F in repairs CP angular stop cock with wall flange of 15 mm bore (Make - Jaquar CAT PART NO- FLR-5053N) all as specified and directed.
S&F in repairs CP Pillar cock taps 15 mm bore with lift type operating knob and base flange Make - Jaquar CAT PART NO- FLR-5015 all as specified and directed.
S&F in repairs Toilet paper holder of vitreous china (White) fixed to walls with chromium plated (CP) brass screws
S&F PVC connections 15 mm size with PTMT nuts of length 450mm
S&F in repairs Soap dish any type fixed to plugs with chromium plated brass screws.
S&F in repairs CP towel rail 600 mm long with round flange (Make - Jaquar CAT PART NO -CAN-1111NM) all as specified and directed.
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finishing the surface fair and even all as specified and directed.
M&L for rendering 20 mm thick pre polymer modified ready mixed cement based plaster in two coats 12 mm thick base coat and 8 mm thick finishing/final coat. Polymer modified ready mixed cement based plaster should having minimum composition of cement & sand 1:4 using fully treated dry, well graded natural sand conforming to IS-383 suitable for external plastering having low rebound properties, low water demand for curing properties, mechnical mixing with water in a matalic tray only to made good, consistency as per the specification of the manufacturer and applied over exterior masonry and concrete surfaces incl using richer mix for making corners if necessary incl making grooves of existing size including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions and necessary two legged MS pipe scaffolding as wherever required incl curing required complete all as specified and directed. (Water proofing compound to be measured and paid for separately).
M&L for rendering 10 mm thick pre polymer modified ready mixed cement based plaster on chajja top and soffits Polymer modified ready mixed cement based plaster should having minimum composition of cement & sand 1:4 using fully treated dry, well graded natural sand conforming to IS-383 suitable for external plastering having low rebound properties, low water demand for curing properties, mechnical mixing with water in a matalic tray only to made good, consistency as per the specification of the manufacturer and applied over exterior masonry and concrete surfaces incl using richer mix for making corners if necessary incl making grooves of existing size including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions and necessary two legged MS pipe scaffolding as wherever required incl curing required complete all as specified and directed. (Water proofing compound to be measured and paid for separately).
Preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of of primer complete all as specified and as directed
M&L for Preparation of surfaces of walls, chajjas, parapets,ceiling etc incld preparation of cracked surfaces removing loose materials after filling the crack with crack filling compound of approved grade and applying one coat of 100% Acrylic exterior emulsion with and incl erection and dismantling of scaffolding to carrying out works upto nine storeys buildings complete all as specified and directed by EIC.
S&Fof vitreous china urinal, half stall type complete including providing andfixing plugs bedding urinal against wall in cement mortar in 1:2 securing urinals to plugswith and including 60 mm brass screws, pointing around urinal back in cement , flush pipes, inlet ,outlet etc complete all as specified Fixed in repairs.
S&F PVC waste Flexible pipe 32mm dia 800mm long with socket sutable for WHB/Sink/urinal complete all as specified and as directed.
S&F Solid PVC Door Frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed by EIC.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. M.S.frame shall be covered with heat moulded design with colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as specified and directed by EIC.
Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes gate stops, parts of ranges, balusters and similar articles exc 5 Kg Each all as specified.
Demolition of Unreinforced cement concrete of any description and in any position not other wise specifically provided for all as specifed and directed.
M&L for PCC 1:2:4 type B-1, (using 20mm graded aggregate) as in foundation, filling mass concrete ,grouting of angle posts, pillars etc including necessary form work complete all as specified and directed.
M & L for water proofing plaster for sunken portion in CM 1:3, 15 mm thick in twon coats with intetgral water proofing compound at the rate of 3% by weight of cement and finishing the surface even and smooth without using extra cement complete all as specified and directed by EIC.
M & L for water proofing treatment of sunken floor/wall surfaces by applying two coats of elastomeric coatings of BRUSHBOND RSX in FOSROC or teckforce 2K STRONG in chowksey Chemical as a two component flexible elastomeric coating with minimum 2mm thickness layer complete all as specified and directed by EIC.
Supply only water proofing chemical pidiproof LW+ of Dr fixit or equivalent.
Complete removal of existing treatment on wall surfaces and applying two coats of oil bound distemper over a coat of primer.
M&L for preparation of old decorated surfaces of wall and applying one coat of oil emulsion distemper all as specified and directed
Preparing old decorated surfaces as in walls soffits & facias of beams, chajjas etc complete by washing, rubbing down & stopping making good the surface & applying 2 coats of weather proof Acrylic based paint (100% Acrylic) exterior Gde .
S & F UPVC pipes of pressure rating 10 Kgf/cm2 fixed complete to walls, celing etc or in floors etc 15 mm bore pipe
-do but 20 mm bore
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets.
M&L for false ceiling made out of 600 x 600 x 4 to 6 mm thick ceiling board/tiles deep panel suspensor system made out of powder coated GI sheet main tee of size 23.50 x 40 x 0.63 mm and cross tee of size 23.50x23.50x0.63 mm and angle size 19x19x0.63 mm including 3 mm GI wire for suspending holts necessary washers nut/cleats/pin hook etc for securing frame work to ceiling to the snap grid including provn of necessary holes/cutting for providing light/far as required including making necessary recesses/projected pattern complete all as spoecified and as directed.
Dismantling water tank of capacity exc. 250 Ltrs but n.exc. 500 ltrs.
S&F rotational moulded polythene water storage tank of 5000 ltrs capacity (cylinderical vertical with closed top) hoisted and fixed in position complete all as specified and as directed by Engr-in-Charge..
Disconnecting existing tanks exc 2000 but n.exc 5000 ltr capacity, setting aside (or lowering if required) for cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes and re-fixing in position all as specified and directed.
S&F rotational moulded polythylene water storage loft tank tank of 300 ltr capacity hoisted including 20 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for inron pipe and fixed (minimum weight 210 grms ) all as specified in SSR Part I.
M & L rendering 20mm thick in two coats(15mm inner coat 5mm finishingcoat) on brick work or concrete surfaces in cement mortar 1:4 finished even and fair including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions including necessary scafolding for high rise bldgs etc all as specified and directed. (Water proofing compound to be measured and paid for separately).
M & L applying damp proof smat care waterproof coating to wall and floor surfaces all as per manufacture instructions including necessary scaffolding for high rise building etc all as specified and directed.
M&L for preparation of newly plastered surfaces of wall, soffits, facia roof and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified.
Dismantling stone slab and tiles of of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc all as specified and directed.
Rounding to edges of stone slabs on edge, such as in steps, cooking platform and making grooves for lining and other similar work complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-1 , (20 mm graded stone agg) as in foundation filling and sunken floors etc all as specified and directed.
Demolition and breaking up drain pipes salt glazed ware, reinforced cement concrete) set in cement mortar 100 mm
-do- but 75 mm bore
-do- but 75 mm bore
S & F PVC (SWR) branch piece 110 mm single Y
-do- but 75 mm bore
S & F PVC (SWR) junction single (single tee) equal or unequal piece 110 mm
-do- but 75 mm bore
S & F PVC (SWR) vent cowl 110 mm
-do- but 75 mm bore
M&L in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent cement75 mm dia.
Taking up or down steel tubing and connections including cleaning and refixing in new or old position (walls, ceilings, floors etc) 100 mm bore pipes.
Taking up or down existing GI water tubing complete with all fittings of 25 mm bore
Taking up or down existing GI water tubing complete with all fittings of 50 mm bore
S & F UPVC pipes of pressure rating 6 kgf/cm2 fixed complete to walls,ceilings or in floors etc any type of pipe 50 mm bore
-do- but 25 mm bore
S&F in repairs Vitreous China wash down water closet pan ( pedestal pattern) , white (excluding fixing bolts, flushing cistern and flush pipe) fixed in repairs
S&F in repairs, Plastic water closet seat, black or white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device.
Supply only cast iron 'P' trap 100mm dia
S&F in repairs Flush pipe of Polyethylene of low or high density or PVC 32 mm dia. for low level cistern
S & F repair for Toilet External Downtake Pipelines for Soil Water Pipes fixing done with Pipe Supporting Clamping System having Profile Bracket + Slotted C Channel + U Bolt R/M System - 1. Soil Water Pipe 4" PVC - 1 nos. running from Terrace to Ground Floor Vertical Fixed line with wall distance 3": Pipe Support Clamping made of 1. Profile Bracket Type A2 (Wall Distance 3") made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Slotted "C" Channel B3 Type to be used of size 10" (Continuous Slotted "C" Channel with ribs) made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty.: 1. Profile Bracket of A2 Type (Wall distance 3") - 2 Nos. 2. Continuous Slotted C Channel of B3 Type Size 10" - 1 No.; 3. U Bolt R/M for 4" PVC Pipe Dia. - 1 No.; 3. Justi Khilla GI coated 2 1/2" - 4 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified in the Technical Drawing. Make : Shaivi or equivalent
S & F repair for Toilet External Downtake Pipelines for Waste Water Pipes fixing done with Pipe Supporting Clamping System having Profile Bracket + Slotted C Channel + U Bolt R/M System - 1. Soil Water Pipe 2 1/2" (75 mm) PVC - 1 nos. running from Terrace to Ground Floor Vertical Fixed line with wall distance 3": Pipe Support Clamping made of 1. Profile Bracket Type A2 (Wall Distance 3") made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Slotted "C" Channel B3 Type to be used of size 10" (Continuous Slotted "C" Channel with ribs) made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty.: 1. Profile Bracket of A2 Type (Wall distance 3") - 2 Nos. 2. Continuous Slotted C Channel of B3 Type Size 10" - 1 No.; 3. U Bolt R/M for 2 1/2" PVC Pipe Dia. - 1 No.; 3. Justi Khilla GI coated 2 1/2" - 4 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified in the Technical Drawing. Make : Shaivi or equivalent
S & F repair of RISER Water Supply pipelines fixing done with Pipe Supporting Clamping System having Profile Bracket + Slotted C Channel + U Bolt System - RISER Water Supply take pipes 4" GI - 1 no. running Vertical Fixed line from 1st floor to Ground floor with wall distance 3": Pipe Support Clamping made of 1. Profile Bracket Type A1 (Wall Distance 2") of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Slotted "C" Channel B3 Type to be used of size 10" (Continuous Slotted C Channel with ribs) made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) are Hot Dip + Zn Al flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty.: 1. Profile Bracket of A1 Type (Wall distance 2") - 2 Nos. 2. Slotted C Channel of B3 Type Size 10" - 1 No.; 3. U Bolt R/M for 4" GI pipe Dia. - 1 nos and 4. Justi Khilla GI coated 2 1/2" - 4 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified in the Technical Drawing. Make : Shaivi or equivalent
S & F repair of Water Supply Downtake pipelines fixing done with Pipe Supporting Clamping System having Profile Bracket + Slotted C Channel + U Bolt System - Water Supply Downtake take pipes 2" UPVC - 8 no. running Vertical Fixed line from 1st floor to Ground floor with wall distance 3": Pipe Support Clamping made of 1. Profile Bracket Type A1 (Wall Distance 2") of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Slotted "C" Channel B3 Type to be used of size 30" (Continuous Slotted C Channel with ribs) made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) are Hot Dip + Zn Al flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty.: 1. Profile Bracket of A1 Type (Wall distance 2") - 2 Nos. 2. Slotted C Channel of B3 Type Size 30" - 1 No.; 3. U Bolt R/M for 2" GI pipe Dia. - 8 nos and 4. Justi Khilla GI coated 2 1/2" - 4 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified in the Technical Drawing. Make : Shaivi or equivalent
S & F repair of Water Supply Downtake pipelines for Tank Supply Riser pipeline fixing done with Pipe Supporting Clamping System having Mono Bracket + U Bolt System - Water Supply Down take pipes 1" UPVC running Vertical Fixed line with wall distance 1": Pipe Support Clamping made of 1. Mono Bracket for single 1" GI pipe having Wall Distance 3" made of Low Carbon Hot Roll Gauge Corrected (HRGC) Steel (IS 1079 DD) with ribs and notch are Hot Dip Galvanized + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs. 2. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 DD used as per MTC confirms to EN 10204 3.1. Material Qty.: 1. Mono Bracket for single 1" UPVC pipe; Wall distance 1" - 2 Nos. 2. Continuous Slotted C Channel of Size 10" - 1 No.; 3. U Bolt R/M for 1" UPVC pipe Dia. - 1 nos and 4. Justi Khilla 2 1/2" - 4 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified in the Technical Drawing. Make : Shaivi or equivalent
S & F repair of Water Supply Downtake pipelines for Tank Supply Riser pipeline fixing done with Pipe Supporting Clamping System having Mono Bracket + U Bolt System - Water Supply Down take pipes 1" UPVC running Vertical Fixed line with wall distance 1": Pipe Support Clamping made of 1. Mono Bracket for single 1" GI pipe having Wall Distance 3" made of Low Carbon Hot Roll Gauge Corrected (HRGC) Steel (IS 1079 DD) with ribs and notch are Hot Dip Galvanized + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs. 2. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 DD used as per MTC confirms to EN 10204 3.1. Material Qty.: 1. Mono Bracket for single 1" UPVC pipe; Wall distance 1" - 2 Nos. 2. Continuous Slotted C Channel of Size 10" - 1 No.; 3. U Bolt R/M for 1" UPVC pipe Dia. - 1 nos and 4. Justi Khilla 2 1/2" - 4 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified in the Technical Drawing. Make : Shaivi or equivalent
S & F Repair of Soil Water Pipe and Water Supply Pipelines for Water Supply Down take three pipelines fixing done with Pipe Supporting Clamping System having Profile Bracket + Continuous Slotted C Channel + U Bolt R/M System - 1. Soil Water Pipe Downtake 4" PVC - 1 no. and 2. Water Supply Down take two pipes 1" UPVC running Vertical Fixed line with wall distance 3": Pipe Support Clamping made of 1. Profile Bracket having Wall Distance 3" made of Low Carbon Hot Roll Gauge Corrected (HRGC) Steel (IS 1079 DD); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921 and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Continuous Slotted "C" Channel with ribs to be used of size 16" made of Low Carbon Hot Roll Gauge Corrected (HRGC) steel (IS 1079 DD) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 DD used as per MTC confirms to EN 10204 3.1. Material Qty.: 1. Profile Bracket Wall distance 3" - 2 Nos. 2. Continuous Slotted C Channel of Size 16" - 1 No.; 3. U Bolt R/M for 4" PVC pipe Dia. - 1 no.; U Bolt R/M for 1" UPVD pipe Dia. - 4 nos and 4. Justi Khilla 2 1/2" - 4 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified in the Technical Drawing. Make : Shaivi or equivalent
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, fan regulators, ceiling roses, lamp holders, brackets, ,removing material to store for keeping in safe custody and making good to disturbed surfaces as directed by Engineer-in-Charge
M&L for concealed point wiring complete with 1.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including casing caping with Accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI make terminal boxes fixed on wall including one PVC insulated & unsheathed multistranded copper conductor 1.5 Sq. mm as earth continuity conductor connected to common earth dolly including modular box and cover plate all as specified.Notes: a) Colour coding shall be followed as given below:- i) Phase - Red ii) Neutral - Black iii) Earth - Green b) Make of wire : Polycab/ Havells/ Finolex/Plaza/Benlo c) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit.
(a) One light point point controlled by one 5A switch
(b) One Fan point/Exhaust fan point controlled by one 5A switch
(d) One 5A flush type switch socket point on same board board
(e) One 5A flush type switch socket point on independent board
M&L for concealed point wiring complete with 2.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make drawn through & including PVC Conduit with Accessories fixed on wall/ceiling/truss etc with metallic ISI make terminal boxes fix on wall including one PVC insulated & unsheathed multistranded copper conductor 2.5 Sq. mm as earth continuity conductor connected to common earth dolly for single board having 1 x15 Amp switch socket point for independent board complete including required size and numbers moduler box and cover plate all as specified & directed. Notes:- a) Colour coding shall be followed as given below:- i) Phase - Red ii) Neutral - Black iii) Earth - Green
M&L for concealed point wiring complete with proper colour coding using PVC insulated unsheathed multistranded copper conductor cable 4.0 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing capping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including required number and size of modular box with cover plate frame in any module complete necessary electric connection for each workstation point comprising of 02 Nos 6A sockets and 01 No 15A socket on same board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Switch socket measured & paid separately.
S & F ceiling rose surface bakelite 65 x 50mm, flush type, 3 terminals complete all as specified and directed by EIC.
S & F switch Piano 1 way 6A all as specified and directed by EIC. Make: Anchor/ Roma/Legrand
S & F switch Piano 1 way 15/16 A all as specified and directed by EIC. Make: Anchor Roma/Legrand
S & F socket, 6A - 2/3 pin combined all as specified and directed by EIC. Make: Anchor/Roma/Legrand
S & switch socket combination 16A,3 pin all as specified and directed by EIC. Make: Anchor/Roma/Legrand
S&F for fan regulator fan flush type on the existing phenolic laminated sheet etc Make: Anchor Roma/Legrand
Supply and fixing in repair new generation walll/surface mounted 1x 20W LED batten fitting, 4 feet surface mounted provides high quality ecomonic energy saving lighting complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round block-02 Nos including connecting up with twin core twisted flexible copper conductor cable with suitable size and all as directed by Engr-in-Charge. Make : C&S/Wipro/Jaguarcat No LGLZ01x020XC/Bajaj
Supply and fixing in repair new generation walll/surface mounted 1x 10 W LED batten fitting, 2 feet surface mounted provides high quality ecomonic energy saving lighting complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round block-02 Nos including connecting up with twin core twisted flexible copper conductor cable with suitable size and all as directed by Engr-in-Charge. Make : C&S/Wipro/Jaguarcat No LGLZ01x020XC/Bajaj
S & F Single pole and neutral enclosure with a two pin and earth plug and socket complete suitable for one single pole MCB 20A all as specified and directed by EIC. Make : Legrand/ Seimens/GE
M&L for concealed sub-main wiring with 2 runs of 2.5sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing & caping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 2.5sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex
M&L for concealed sub-main wiring with 2 runs of 4.0sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing & caping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 4.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex
M&L for concealed sub-main wiring with 2 runs of 6.0sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC conduit not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 6.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex
M&L for sub-main wiring with 4 runs of 10.0sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC conduit not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 10.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex
S&F in repair sheet metal enclosure TPN DB VTPN 8 Way,415V with 250A copper busbar, double door type IP-54, IK-09 protection suitable for housing MCCB 100Amp 4 pole incl required numbers of suitable size of gland complete etc all as specified and directed by EIC. Make: Siemens/Legrand /GE Note : DBs shall be conceeled in wall where ever posible including making good the surface to match with surrounding. Make: Legrand/ Seimens/GE
S & F in repair MCB DB double door SPN 8 Way with 200 Amps rated copper bus bar, IP 54, IK 09 suitable for flush mounting and surface mounting complete etc all as specified and directed. Make: Legrand / Seimens/GE
S & F in repair MCB DB double door SPN 12 Way with 200 Amps rated copper bus bar, IP 54, IK 09 suitable for flush mounting and surface mounting complete etc all as specified and directed. Make: Legrand/ Seimens/GE
S & F MCCB FP 125 Amps,16KA, thermal magnetic,415volts complete all as specified and directed. Make : Legrand cat No 420016/Seimens/GE
S & F MCB SPN 63 Amps,10KA , 'C' curve Make: Legrand/ Seimens/GE
S & F MCB SPN 40 Amps,10KA , 'C' curve Make: Legrand/ Seimens/GE
S & F MCB SP 6-32 Amps,10KA, 'C' curve, Make: Legrand/ Seimens/GE
S & F MCB SP 40 Amps,10KA, 'C' curve, Make: Legrand/ Seimens/GE
Supply of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 32 mm dia with 250 micron ( average ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF ECO SAFE compound shall be supplied in 50 Pound Bag. ( 1 Bag required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set incl Supply of Eco Friendly weather proof High Density Polyethylene Earth Pit Chamber Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
M&L for 25x4mm GI earth continuity conductor or main earthing lead fixed to wall or buried in ground or drawn in conduit/ pipe or fixed to transformer/panel body complete all as specified
Disconnecting & taking down old Unservicable cable & Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3½ core complete all as specified and directed by Engr-in-Charge.Make: Polycab/havells/Finolex.Gloster
M&L for shifting of Split AC/Window unit from existing postion & refixing the new position/location including additional accerssories as required, bressing of existing copper pipe with new copper pipe, leak testing, testing & commisssioning all as specified and directed BY EIC.
Supply and fixing copper tubings of appropriate dia for suction line & for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing thugh pipe and making good distrubed surface completely.
S& F GI cable tray perforated type 2 mm thick of size 250x50mm ( Including pre fabricated GI clamp suitable for fixing/supporting ) with0.71mm thick aluminium sheet cover, alloy 31000 H4 in ridges, Hips vally gutter cable trucking for plain to be fixed on any wall (brick/stone) vertically/horizontally including all accessories complete bending,shaping,drilling,welding, cutting & all fixing arrangement complete etc all as directed
S& F GI cable tray perforated type 2 mm thick of size 450x50mm ( Including pre fabricated GI clamp suitable for fixing/supporting ) with0.71mm thick aluminium sheet cover, alloy 31000 H4 in ridges, Hips vally gutter cable trucking for plain to be fixed on any wall (brick/stone) vertically/horizontally including all accessories complete bending,shaping,drilling,welding, cutting & all fixing arrangement complete etc all as directed
S & F exhaust fan of sweep 300 mm heavy duty type complete with self closing MS louvers, mounted in suitable opening arrangement and suitable for operation on 230 Volts single phase 50 Hz AC supply and connectin up with and including two core PVC insulated, PVC sheathed copper conductor including fixing and making connection and fixed by using 4 Nos 200 mm long 12 mm dia bolts, nuts and washers and grouted in wall in CM 1:3 completed all as specified and directed. Make: Havells/ khaitan / Bajaj
SB CONSTRUCTION
Laxmi Sales
Genius Construction Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .