Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 266 UTTAMNAGAR NDA ROAD PUNE 411023 | PUNE | MAHARASHTRA | 411023 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
18 Jan 2020, 9:00 amClosed
GE I R AND D GIRINAGAR PUNE
GE I R AND D GIRINAGAR PUNE 411025
ADDN ALTN TO COOKHOUSE OF OFFICERS MESS PROVN OF STORAGE SPACE NEAR TRG WKSHOP AND PROVN OF LIGHTING OF SPORTS COMPLEX CERTAIN OTHER PLACES IN DOMESTIC AREA AND OFFICER MESS OF MILIT GIRINAGAR PUNE
2019_MES_306101_1
GE I R AND D GNR TOKEN 79 OF 2019 20
Open Tender
Civil Works
Works
180 days
GE I R AND D GIRINAGAR PUNE
ADDN ALTN TO COOKHOUSE OF OFFICERS MESS PROVN OF STORAGE SPACE NEAR TRG WKSHOP AND PROVN OF LIGHTING OF SPORTS COMPLEX CERTAIN OTHER PLACES IN DOMESTIC AREA AND OFFICER MESS OF MILIT GIRINAGAR PUNE
6 documents required · 6 mandatory
₹500
GE I R AND D GIRINAGAR PUNE
₹86,000
Yes
21 Jan 2020
12 Dec 2019
20 Jan 2020
12 Dec 2019
18 Jan 2020
6 Jan 2020
12 Dec 2019 - 2 Jan 2020
Amount
Demolition of cement concrete (Reinforced) in roofs, floors, beams staircase, landing chajjas and similar suspended work and removing from site all as specified and directed.
Formwork to sides of pillars posts columns and stanchions
M&L for Concrete M25 (Nominal Mix) for Column, Post etc
M&L for TMT Reinforcement cut to length bent to shape reqd incl cranking, bending spirally for column hooking ends and binding with and incl mild steel wire not less than 0.9mm dia or securing with clips quality conforming to
Same as per item above but 5mm dia and over upto and including 10mm dia in stirrups spacers and binders
Steel work in any type/shape of tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming ot IS 1161-1979 grade st 240
M&L for plates (Plain or cheqered) channels, square cut or notched forming holes, without any attachement grade Fe410 -W (Gde E-250) quality-A
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide or zinc chrome primer.
M&L 2mm thk for fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed wiht self tapping screw and washer in roof, wall etc Note : Sheet shall be fixed in curve/Semi circular pattern over truss.
S&F PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall with PVC Clip and Ring of size 110mm bore
S&F PVC (SWR) bends any radius 110 mm bore
Taking down chowkats or frame of wooden or steel Not exc 1.5 Sqm with shutters (without taking of shutter from the frame).
Forming jambs etc to opening including cutting toothing and properly bonding into old work including facing and pointing (if necessary) to match existing work complete in CM 1:4
M&L for Precast cement concrete block masonary Type C1 1:3:6 with solid blocks exc 10cm in width and setting in CM 1:6
Rendering 10 mm thick of fair faces of stone work in CM 1;6. finished even and smooth without using extra cement.
Rendering 15 mm thick of fair faces of stone work in CM 1:4 with waterproofing compound finished even and smooth without using extra cement.
M&L for Powder coated aluminium frame for doors, windows, ventilators with one or more rebate including joining cleat for fixing etc complete.
M&L for Powder coated aluminium window and ventilator shutters, fixed type/sliding type without sash bar, aluminium section wighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, Handle, lock, powder coated aluminium snap beading scres etc complete
M&L Framed work such as grills,gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe-290.Gde-E-165 for MS framed work as in trusses, purlins, rafters, post etc conforming to grade E-250 (Fe 410W, quality 'A') including shaped washers, including necessary cutting required length, notching, drilling, riveting and or welding or connecting with nut bolts with angle cleats, fish plate, gusset plate and also erecting in true position complete as directed.
Removal of entire existing water proofing treatment in any position including tarfelt plaster, lean concrete , gravels etc and removing the debirs out side MD land all as pecified and directed.
M&L for 10 mm thick rendering in CM 1:4 over concrete surfaces (Roof) mixed with water proofing compound @ 3% by weight of cement complete all as specified. Note: Water Proofing compound shall be measured and paid for seprately as "Supply Only"
M & L for APP based polymeric membrane minimum weight 3 Kgs/Sqm and minimum 3 mm thick reinforced with polyster non-woven fabric ( wt not less than 150 gms/sqm laid over primed surface with oil based bituminous primer conforming to IS- 3384 @ 0.3 litre/sqm and finishing with preventive coat of aluminium paint @ 100ml/sqm all as directed and specified.
Supply only WPC.
M&L for coloured vitrified tiles 600x600x9-10mm thick as in flooring, set and jointed in neat cement slurry and pointed in coloured cement to match with tiles, laid over and including 15mm thick screed bed in CM 1:4 over 75mm Thk PCC Subbase Type D2 1:4:8 all as specified and directed by Engr-in-Charge.
M&L for coloured vitrified tiles 9-10mm thick as in skirting, set and jointed in neat cement slurry and pointed in coloured cement to match with tiles, laid over and including 10mm thick backing coat in CM (1:3). all as specified and directed by Engr-in-Charge.
Surface dressing n. exc.15 cm deep in soft/loose soil
Excavation in trenches not exc 1.50mtr wide and not exc 1.50mtr in depth for foundation etc and getting out in hard / dense soil.
All as per item No-2 above but exc 1.50m deep or part thereof in depth beyond the first 1.50m.
M&L for cement concrete (1:4:8) type D2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete all as specified and directed.
M&L RCC M-25 Design Mix, using 20 mm graded aggregate as foundation beams,plinth beams,bases for Columns,etc;basement slabs, under-reamed piles and mass concrete all as specified and directed.
M&L RCC M-25 Design Mix, using 20 mm graded aggregate as columns,pillars,piers,posts and struts all as specified and directed.
M&L RCC M-25 Design Mix, using 20 mm graded aggregate as slab supported on walls,beams and column I floor roofs,and in shelves etc. all as specified and directed.
M&L RCC M-25 Design Mix, using 20 mm graded aggregate as as in beams,cantilevers,lintels,over 1.5 m span all as specified and directed.
M&L RCC M-25 Design Mix, using 20 mm graded aggregate as as in chajjas and like all as specified and directed.
M & L for treating the backfill in contact with the foundation at the rate of 7.5 Ltrs of anti termite emulsion per Sqm of vertical surface.
M & L for treating the top surface of filled earth and soil under plinth protection at the rate of 5 Ltrs of anti termite emulsion per Sqm of surface.
M&L for treating the soil along with external perimeter of building at the rate of 2.25 lit of emulsion per meter of the perimeter wall
Excavated soil filling under floors including spreading and leveling in layers n exc 25cm thick and well ramming including watering complete.
M&L 75 mm thick PCC 1:4:8 type D2 using 40 mm graded aggregate as in sub base
M&L for Machine cut kota stone slab flooring 20-25mm thick over 20mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete.
M&L Mirror polished kota stone 20-25mm thick in riser of steps, skirting, dado and piller laid over backing coat of 12mm thick in CM 1:4 and jointed with as per above item 100mm High
M&L for hard core of broken boulders of gauge n. exc 63mm, deposited, spread and levelled and layers n. exc 15 cm thick waterd and rammed to a true surface all as spd and directed
M&L for 75mm thick PCC 1:3:6 type C-2 (40mm graded stone aggregate) , without using extra cement as in plinth protection and path etc complete all as specified and directed.
M&L for precast cement concrete block masonry with solid blocks of PCC 1:3:6 type D1 using 20 mm graded stone aggregate, exc. 10 cm in width and setting in CM 1:6, complete.
Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips.
-Ditto - all as per item No 19 above but 8mm dia
Ditto but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) for rough finished surface of concrete.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
Formwork to sides of concrete foundations, footings, bases of columns, rafts raft beams, sides and soffits ( if any ) of foundation and plinth beams; and similar work; vertical or batter, finished rough surfaces of concrete, complete all as specified and directed.
formwork to sides of pillars,posts ,struts,piers,columns and stanchions for rough finished surfaces of concrete square and rectangular all as specified.
M & L formwork to chullah hoods, chajjas, trough and similar items including edges finished rough surfaces of concrete complete all as specified.
M&L form work to edges of concrete flats, treads breakin in floors, window cill, chajja,roofs slabs and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5 but not exc. 10 cm wide complete all as specified
S & F pressed steel frames for doors with one or more rebates incl necessary hold fasts, hinges, lock strike plate etc complete as specified size of frame 125 x 60mm.
S&FS & F IInd class hard wood 35mm thick factory made, glazed and skeleton shutter open rebated and prepared to receive glass,gauge,etc.edges of framing plain,chamfered or rounded fitted with cut and mitred beads for securing glass,etc; The size of the rail and stile as per IS 1003 (Part-I), Kiln seasoned and chemically pressure treated.
Preparation of new wooden surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
S&F aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section etc length of bolt 250 mm.
S&F aluminium anodised barrel tower bolts of extruded section 200 mm long.
S&F butt hinges 100mm size stainless steel medium weight all as specified.
S&F aluminium handles, anodised, cast type, of size 150 mm
S&F steel rolling shutter 1.25 mm thick of laths including Top cover , anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated complete , gear operated type with baved gear box and crank handle.
M&L for two coats of aluminium paint on new steel surfaces
S&F steel windows with side hung shutters including projecting type hinges with steel handles,steel peg stays complete with glazing bars dovetailed or welded,complete all as specified and directed.
M & L sheet glass ordinary quality 4mm thick and glazing with oil putty in squares exc. 0.5 sqm each pane complete all as specified.
M&L for preparing New surfaces , plastered or unplasterered and applying two coat of external emulsion paint over a coat of primer on walls/fins/fascia/ceiling etc including necessary scaffolding etc all as specified.
M&L for applying two coats of OBD, white over a coat of primer tinted, over 3mm thick wall care putty all as directed .
M&L for preparation of new plastered or unplastered ceiling surfaces and applying three coat of white wash as specified and directed by Engr -in-Charge.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide or zinc chrome primer.
S&F framed work such as grills, gratings etc, with ends of bars shouldered and or riveted or ferged into spikes, framed guard bars
M&L rendering 5 mm thick in CM (1:3) on concrete surface in ceilling finished even & smooth w/o using extra cement.
M&L for Rendring 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 on walls ,finishing surfaces even and smooth w/o using extra cement.
M&L for 15 mm thick rendering in CM 1:4 in two coats (10+5mm) over concrete /Brick/PCC Block surfaces mixed with water proofing compound @ 3% by weight of cement, finishing even and smooth without using extra cement complete all as specified. Note: Water Proofing compound shall be measured and paid for seprately as "Supply Only"
M&L for 10 mm thick rendering in CM 1:3 over concrete surfaces (Roof) mixed with water proofing compound @ 3% by weight of cement complete all as specified. Note: Water Proofing compound shall be measured and paid for seprately as "Supply Only"
Supply only WPC conforming to IS 2645
M & L for APP based polymeric membrane minimum weight 3 Kgs/Sqm and minimum 3 mm thick reinforced with polyster non-woven fabric ( wt not less than 150 gms/sqm) laid over primed surface with bituminous primer conforming to IS- 3384 @ 0.3 litre/sqm and finishing with preventive coat with aluminium paint @ 100m/sqm all as directed and specified.
Returning filling in including spreading, levelling, watering & well ramming in layers n.exc 25cm each.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and average 15 cm deep and getting out in soft / loose soil
M&L for hard core of broken stone or boulders of gauge n. exc. 63 mm, deposited, spread and leveled in layers n. exc. 15 cm thick, watered and rammed to a true surface.
M&L PCC in kerb Stone precast (factory made) any shape and size or as directed by engr in charge including weathering, slightly rounded or chamfered angles and throating, in type B-1 1:2:4 (20mm graded agg) set in cement mortar 1:4, complete all as spfd and directed.
M&L 75 mm thick cement concrete type D-2,1:4:8 (40mm graded stone aggt) as in sub floors, filling and mass concrete etc complete all as specified.
M & L for machine made Rubber moulded precast conctete interlocking paver block (coloured), Glossy finish pre polished of any shape and size with white cement and pigment confirming to IS 15658-2006 of 60 mm thickness M-35 Grade and over and including 25mm average thickness sand cushioning complete all as spfd and directed.
Removing excavated material (soil) exc. 250 m but n exc 500 mand depositing where directed at a level n.exc. 1.5 m above the starting point.
M&L for Point wiring complete with multistranded copper conductor cable (ISI marked) 1.5 Sqm PVC insulated, unsheathed cable 1100 volts FRLS grade drawn through in and including concealed non metalic rigid PVC conduit and all accessories such as bends, tees, junction boxes etc, concealed conduit in walls / roofs / ceiling etc.and including provision of continuous earth wire of size 1.5 Sqmm copper conductor PVC insulated unsheathed connected to earth dolly, Including terminated in terminal box made out of 1.60 mm thick MS sheet concealed in walls and including Metal flush box with Modular white cover plate and top as per site requirenment for housing the switches, socket outlet, fan regulator etc, cutting chases and making good to disturbed surface complete for the following :- (a) One light point controlled by one 6 Amps one way switch.
(b) One ceiling Fan, Exhaust Fan point controlled by one 6 Amps switch.
(c) One 3 pin switch socket outlet point 6 Amps on independent board.
(d) One 3 pin switch socket outlet point 6 Amps on same board with other switch.
All as per item above here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size.
S & F modular switch1 way 6A, 1 module
S & F modular switch1 way 16A, 1 module
S & F socket out let 6A 2/3 on combined 2 module
S & F socket out let 6A/16A-2/3 pin combined 2 module
S & Fix ceiling rose surface backlite 65x50mm 3 terminals complete.
S & F fan regulator electronic 2 modular type volts AC 50 HZ ,100 Watts,4 step complete all as directed.
S & Fix LED light 18W Batten integrated fitting,Engineering LED channel with acrylic cover,Natural white with accessories fixing arrangments all as specified Make-Bajaj Cat part No-BCLSB 18 WH or Eqvt In other.
S & Fix Fans ceiling complete with one electronic type regulater and accessories 230 volts,1200 mm sweep(white colour) complete all as specified & directed. Make : Havells,Bajaj and Usha
S & Fix Metallic type exhaust fan AC single phase 230 volts of size 300mm sweep with Louver and including ball opening as per site requirements and finishing complete all as specified and directed Make-Havells cat part -Ventil Air-DS,or Eqvt model in Bajaj,crompton and USHA.
S & Fix LED street light 30 W CUB type building security light pressure die cast aluminium housing LED street light lumaniries with IP 66 and complete accessories all as specified and directed by Engr-in-charge Make- Bajaj cart part no_BCLST 30W LED I
S & Fix of bracket / arm for street light fiting made out of 40 mm dia GI pipe not exceeding 2.5 mtr long complete accessories including fixing of MS clamps 2 Nos nut and bolts complete as directed.
S & Fix in replacement of 2 runs of 1.5 Sqmm PVC insulated stranded copper cable for connection of building street light including PVC conduit 20 mm external dia medium grade fixed on building with proper clamping, saddling etc all as directed.
S & Fix of sheet metal enclosure for DB’s (Double door type) when MCB’s to be used, single pole and neutral, 8 ways with 100 ampere rated bus bar, 415 volts fixed sunk/flush to the wall or niche complete all as specified and directed Make- Legrand/C&S/Standard/Schnieder.
S & Fix of MCB single pole and neutral, 240 volts, 40 to 63 Amps, rupturing capacity 10 KA, ‘B’ series complete all as specified and directed.
S & Fix of MCB single pole, 240 volts, 6 to 40 Ampere, rupturing capacity 10 KA, ‘B’ series complete all as specified and directed.
Supply and Laying and testing cable XLPE insulated heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm, 2 core cable connecting lugs, glands, jointing materials etc, laid on wall, floors, roof, ducts and fixing using clamps, saddle complete all as directed by Eng-in-charge of following:-
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in Hard / dense or any type of soil including forming bottom surface etc.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 50 mtr above the starting point.
Supply & Laying 50 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement.
M &L for GI pipe ''light grade'' for road crossing / on wall / on pole for cable protection of following size:- Make: TATA/JINDAL/ PRAKASH SURYA a) 50 mm dia
M&L for earthing complete with galvanised steel earth plate electrode 600 X 600 X 6mm thick buried directly in ground (earth pit not less than 2.25M deep below ground level) with top edge of the plate not less that 1.5M below normal grouond level connected to GI earth wire 4mm dia by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No 03 of SSR Part-I connected to earthing test point / DB including excavation / earth work in any type of strata, removal of surplus earth, GI pipe for watering pipe withand funnel, PCC 1:3:6 Type C-1 chamber with 40mm thick RCC 1:2:4 type B-1 in cover slab with TMT bars @ 150 mm c/c both way with GI protection pipe complete all as specified and directed by Engineer-in-Charge
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in soft soil including forming bottom surface etc.
Returning, filling in including spreading, levelling ,watering and well ramming in layers not exceeding 25 cm thick complete.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
Supply and Laying in trenches LT underground cable ISI marked XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc, laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole,making hole in wall as per requirement at site complete all as directed by Eng-in-charge of following:- (a) 2 core 6 Sqmm
(b) 4 core 16 Sqmm
Supply & Laying 40 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement
M & L for cutting of bituminous road / floor for laying of pipe / cables not exceeding 0.30 meter wide and not exceeding 0.45 meter deep including refilling / with material and , watering well ramming / compacting and making good with PCC 1;2;4,type B-1, 100 mm thick complete all as specified and directed by Engr-in-Charge.
M & L for GI pipe light grade, for road crossing / on wall / on pole for cable protection of following size:- Make: TATA/JINDAL/ PRAKASH SURYA a) 40 mm dia
Supply and fixing steel tublar swaged poles complete with cast iron base plate, final taper plug, bolts, nuts, & screws as specified type 410 SP - 31 ( 9.0 Meter long) all as directed by engr - in - charge
M & L Cross arms, bracing, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint as specified and directed by engr in charge.
S & Fix outdoor type FRP junction box light weight suitable for pole mounting inclduing MCB SP 6 Amps single pole, flat iron clamp duly painted with two coats of aluminium paint over a coat of red oxide primer and GI nut, bolts, washers and necessary connector for loop in loop out cable connection and suitable size galnds, of size 230x170x105mm. Make - Syntex/ Anchor
S & Fix LED Flood light 100 W High performance IP 66 LED flood light lumaniries with secondary optics made in pressure die - cast housing and heat sink in aluminium extrusion and all fixing arrengenment of pole / wall/bracket / chanel by belding and nut and bolts complete accessories all as specified and directed by Engr-in-charge Make- Bajaj cat No: Wipro cat part No -LF20-122-060-57-G2 or Eqvt in Havells/Crompton.
S & Fix LED Flood light 150 W High performance IP 66 LED flood light lumaniries with secondary optics made in pressure die - cast housing and heat sink in aluminium extrusion . complete accessories all as specified and directed by Engr-in-charge Make- Wipro cat part No -LF20-192-060-57-G2 or Eqvt in Havells/Crompton.
S & Fix LED Flood light 200 W High performance IP 66 LED flood light lumaniries with secondary optics made in pressure die - cast housing and heat sink in aluminium extrusion . complete accessories all as specified and directed by Engr-in-charge Make- Wipro cat part No -LF20-272-060-57-G2 or Eqvt in Havells/Crompton.
S & Fix 3 x 1 sqmm PVC circular copper cable for connection of street light pole, building security light, post top lights and garden light including all fixing arrangement with proper clamping, sadling etc all as directed.
Supply, install,commissioning and testing Cubical outdoor type factory made double door, powder coated LT Bus bar feeder piller box for 200 amps 3 Ph and neutral arrengenment of size 500mm x 500mm x 200 mm to accomodate the following :- (i) Aluminium bus bar 3 phase 4 wire-200 Amps -01 set (ii) MCCB TPN 63 amps-01 nos (ii) MCB SP 32 amps-02 nos and weather proof and verminproof conforming to IP - 54 made out of 3.15 mm thick CRCA sheet including provision for ventilation and cable termination alley all as per IS. It should be mounted on 40 x40 x6 mm angle frame with a clearance of at least o.45 mtrs above GL na 0.30 mtrs below ground including PCC for foundation and coping.
M&L for earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25M deep below ground level) with top edge of the plate not less that 1.5 M below normal grouond level connected to GI earth wire 4 mm dia by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No 03 of SSR Part-I connected to earthing test point / DB including excavation / earth work in any type of strata, removal of surplus earth, GI pipe for watering pipe with and funnel, PCC 1:3:6 Type C-1 chamber with 40 mm thick RCC 1:2:4 type B-1 in cover slab with TMT bars @ 150 mm c/c both way with GI protection pipe complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:4:8 Type D2 using 40 mm graded aggregate in foundation including form work and finishing the exposed surface of concrete even and smooth all as specified.
M&L for providing PCC 1:2:4 type B-1 with 20 mm graded aggregate for coping of pole complete all as directed.
J.G.Goel
M/S P D TUPE
DAKSH ENGINEERS AND BUILDERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .