Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.5 LAccepted-AOC 41 A COLONELGANJ CANTT FATEHGARH DISTT FARRUKHABAD UP 209601 | FATEHGARH | FARRUKHABAD | UP | 209601 | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹14.9 L+₹1.0 L (7.28%)Rejected-Finance | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹14.9 L+₹1.1 L (7.68%)Rejected-Finance | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹22.5 L+₹8.6 L (62.4%)Rejected-Finance | 4 | Rejected-Finance Not being lowest |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
30 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Agra
112 Taj road Agra Cantt
REPAIR / MAINT HT DISTRIBUTION SYSTEM AND OTHER ALLIED WORKS AT FATEHGARH CANTT
2022_MES_549622_1
86115/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Fatehgarh
MES contractors enlisted in Class E category b(ii) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹29,000
Yes
23 Nov 2022
2 Sept 2022
8 Oct 2022
2 Sept 2022
30 Sept 2022
16 Sept 2022
2 Sept 2022 - 9 Sept 2022
Amount
Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n'exc. 1.50m deep for HT under ground cable/pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed
Returning filling including spreading leveling watering and well ramming in layers not exc 25Cm in soft/ loose soil, complete all as specified and directed.
Removing excavated material in soft/ loose soil n.'exc 50M and depositing where directed at a level n.'exc1.5M above the starting point, complete all as specified and directed.
Dismantling cross-arms of mild steel channel or angle sections etc including mild steel bolts , nuts,washers etc complete all as specified and as directed
Dismantling insulators like Pin type, disc type from existing electric poles of any description and of any size,seggregating serviceable insulators and keep in safe custody for re-use complete all as specified and as directed
Dismantling ACSR conductors from the disturbed span including line spacer etc complete all as specified and as directed
Dismantling of old unserviceable HT concrete/Steel pole of 11 Mtr long with necessary demolition of concrete foundation including excavation, earth work complete all as specified and as directed. Note :- Arrangement of all safety equipment shall be deemed included in rates.
M&L for sand cushioning to U/G cable in layers of 23 cm thick ( 8 Cm before laying the cable and 15 Cm thick after laying the cable) in trenches complete all as specified and directed. Note :- Only Puned down volume shall be measured.
Supply and laying un-reinforced precast concrete cable cover, class HV, Type I, flat of size 300 mm x 180 mm x 40 mm laid dry for protection of UG cable complete all as specified and directed
Dismantling / Taking out unserviceable HT cables for renewal of any size from any position i.e ground / walls / poles / culverts etc complete with protection pipe complete all as specified and directed. ( Note : Earth work shall be measured and paid separately)
Supply, laying , jointing and testing of HT XLPE cable 3 core, 11000 volt screened, PVC bedded "Earthed grade" insulated bedded, galvanised steel (Heavy duty) strip armoured with aluminium conductor 11 KV pressure earth system confirming to IS-7098(Part-I) 1977 and part-II of 1985 laid in pipe /ducts/trenches, under floor and road or fixedd to wall etc complete cross-sectional area of cable 95 sqmm 3 core, complete all as specified and directed .
Supply, laying , jointing and testing of HT XLPE cable 3 core, 11000 volt screened, PVC bedded "Earthed grade" insulated bedded, galvanised steel (Heavy duty) strip armoured with aluminium conductor 11 KV pressure earth system confirming to IS-7098(Part-I) 1977 and part-II of 1985 laid in pipe /ducts/trenches, under floor and road or fixedd to wall etc complete cross-sectional area of cable 120 sqmm 3 core, complete all as specified and directed .
M&L in renewal of GI tubing light grade for passing through cables under the floor ,along the wall or along the pole of 80 mm bore and fixed to the poles/walls with suitable size of MS clamps and nut and botls/washers etc complete all as specified and directed.
Ditto all as per item No.13 above but S&F in renewal
M&L Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of two coats of Aluminium Paint over a coat of red oxide primer, complete all as specified and as directed.
Material and labour for lightning arrester 11000 volts non linear resister type conforming to IS-3070 part-I, line discharge class-2, nominal discharge 10 KA and high discharge 65 KA assembly complete suitable for 11 KV including all clamps, nuts, bolts and washers and connecting to earth with 4 mm dia GI wire complete all as specified and directed.
M&L in renewal of outdoor end terminal joints cold shrinkable Suitable for HT 11000V (Earthed), XLPE insulated armoured Heavy duty under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable of cross sectional area 120 Sqmm 3 Core complete all as specified and directed.
M&L in renewal of outdoor end terminal joints cold shrinkable Suitable for HT 11000V (Earthed), XLPE insulated armoured Heavy duty under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable of cross sectional area 95 Sqmm 3 Core complete all as specified and directed.
M&L in renewal of straight through joints cold shrinkable Suitable for HT 11000V, XLPE insulated armoured Heavy duty under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable of cross sectional area 120 Sqmm 3 Core complete all as specified and directed.
M&L in renewal of straight through joints cold shrinkable Suitable for HT 11000V, XLPE insulated armoured Heavy duty under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable of cross sectional area 95 Sqmm 3 Core complete all as specified and directed.
Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. ( Note : - GI Pipe laid will be measured and paid separately under appropriate item)
Supply, installation, commissioning and testing of switch air break gang operated HT 11000 volts grade triple pole with 09 insulators, 200 amp capacity current rating complete with dropout fuse assembly with fuse carrier fuse elements mounted on insulators and steel frame mechanically operated mechanism from ground level consisting of rod of 25 mm nbore GI pipe, light grade of suitable length worked from ground level with locking arrangement fixed with flat iron clamp 50X6 mm and MS channel of suitable size & length for fixing GO/DO including bolts, nuts and washers complete all as specified and directed.
S&F steel tubular swaged pole type 410 SP 55 (11 mtr. Long) complete with cast iron base plate/final taper plug, bolt, nuts and washers including excavation earth work in any type of soil , PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in plinth block ,copping in PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) including two coats of aluminium painting over a coat of red oxide primer on external surface and black bituminous paint on internal surface of pole and external surface upto planting depth as specified in SSR 2009 Part-I including writing pole numbers with white lettering on black background and making black & yellow strips upto 1.5 mtr height complete all as specified and directed.
S & F Pin type insulator porcelain,vitreous,white,brown or green including one galvanised spindle, two galvanised iron washer and one galvanised iron nut 150 mm height , 150 mm dia for 11 KV grade complete all as specified and as directed
Fixing only Pin type insulator (serviceable insulator obtained from item No.5 here in before) complete all as specified and as directed
S & F Disc type insulator porcelain,vitreous,145 mm high and 255 mm dia ball and socket type white, brown or green insulator single disc assembly for tension with tension clamps for conductors working pressure 11000 V complete all as specified and as directed
Fixing only Disc type insulator porcelain (serviceable insulator obtained from item No- 5 here-in-before) complete all as specified and as directed
S & F Aiuminium conductor steel reinforced ( ACSR) (sizes as ordered) with permissible sags and providing jumper etc fixing on electric poles and binding to insulators with Aluminium binding wire as in over head conductors including stringing, tightning etc complete all as specified and as directed. Note : Cost of binding wire is deemed to be included in the quoted unite rate
Restringing ACSR Conductor of exsisting OH lines by un-binding from insulator of any description, re-fixing after stretching,re-stringing the conductor, removing excess sag,maintaining proper distance between conductors as order and binding to insulators with aluminium binding wire complete all as specified and as directed.
Supply and fix earth continuity conductor or main earthing lead fixed to wall or on pole or any other indicated situation as GI strip of size 25x4 mm connected to test point complete all as specified and as directed
Dismantling and Taking out Transformer from its position from any location under AGE(I) Fatehgarh for repair/rewinding of capacity 100 to 500 KVA , 11/0.433 KV capacity disconnecting /opening HV, LV Electrical connections, earthing connections along with following other works. (a) Transporation of transformer to workshop at Unnao/Kanpur and back to site by making necessary arrangements of T&P (crane, recovery, vehicle, tripoid to be arranged by firm ) complete all as specified and directed. (b) Opening of transformer top cover by extraction ,removing of serviceable - unserviceable nuts bolts and washers etc in presence of Engr -in -Charge. (c).Draining out of transformer oil and keeping in safe custody for reuse (d) Lifting primary coil (HT) and secondary coil (LT) , dismantaling of transformer complete part by part carefully , and display all the parts without damaging any portion for inspection of Engr -in -Charge. (e) Refilling topping up of transformer oil after dehyderation and filteration in transformer. (f) Reassembeling the transformer complete with all existing serviceable parts, and new parts as ordered. (g) Reinstall the Transformer at site in position as directed after repair connecting HV, LV electrical connections, earthing connections and testing to entire satisfaction on load. Note- (a) Payment shall be made on actual weight basis i.e. actual weight of finished coil before varnishing and bakinge. (b) Renewal of adequate size Nut, bolts & washers of transformer top cover shall deemed to be included in UNIT RATE QUOATED
M & L for rewinding HT coil of 11/0.433 KV Transformer any capacity using proper size DPC copper wire and insulation material,heating coils in heat chamber after rewinding including taking out carefully burnt unserviceable copper winding of coils complete all as specified and directed.
M & L for rewinding LT coil of 11/0.433 KV Transformer any capacity using proper size DPC copper wire and insulation material,heating coils in heat chamber after rewinding including taking out carefully burnt unserviceable copper winding of coils complete all as specified and directed.
Dehydration and filtration of existing transformer oil of transformers capacity ranging from 100 KVA to 1500 KVA ( 1/0.433 KV ) on site at different locations without disturbing the power supply system with filtration machine and heating system in order to achieve Di-electri strength of oil 40 KV minimum 2.5 mm gap complete all as specified and as directed. Note : (a) Testing of transformer HT switch gear oil before & after dehydration shall be carried out as directed (b) The unit of payment under this term shall be per liter of oil meant for all process to the entire completion of jobs
Supply and filling up of Transformer oil conforming to as per IS:335-1993 in topping up/renewal up to desired level of transformer oil capacity complete all as specified and directed. ( Note : Dielectric strength of oil should not be less than 50 KV complete all as specified and directed.
Supply and renewing silica gel in crystal form of breather assembly of transformer capacity upto 1500 KVA at installed site complete all as specified and directed.
Repair / servicing to transformer at site of capacity 100 to 500 KVA installed on plinth/pole mounted structure by opening top cover & renewing unserviceable spares/components of transformer ,without lifting core assembly reassembling after repair & testing complete all as specified and directed
Supply only ceramic Bush insulator on LT side as per existing size,shape and specification for capacity 100 to 500 KVA ,11/0.433 KV transformer complete all as specified and directed
Supply only ceramic Bush insulator on HT side as per existing size,shape and specification for capacity 100 to 500 KVA ,11/0.433 KV transformer complete all as specified and directed
Supply only cork sheet gasket ( set of four) for ceramic bushing on LT side as per existing size,shape and specification for capacity 100 to 500 KVA ,11/0.433 KV transformer complete all as specified and directed
Supply only top cover gasket as per suitable size,shape and specification for capacity 100 to 500 KVA ,11/0.433 KV transformer complete all as specified and directed
Supply only transparent breather assembly as per suitable size,shape and specification for capacity 100 to 500 KVA ,11/0.433 KV transformer complete all as specified and directed
M & L for preparing old painted surfaces by scrapping and removing old paints, rust etc from steel tubular poles ( above the planting depth and PCC coping of 11.0 Metre length pole ) and Mild Steel cross arms,cable protection pipe,brackets etc and applying one coat of synthetic enamel paint alternate yellow & black strips painting( 5 nos each strip 300 mm wide) and remaining portion of pole and cross arms,cable protection pipe,brackets etc treated with one coats of Aluminium paint incl writing pole no with white paint on black back ground complete all as specified and as directed
M & L for 2 Pole structure preparing old painted surfaces by scrapping and removing old paints, rust etc from steel tubular poles ( above the planting depth and PCC coping of 11.0 Metre length pole ) and Mild Steel cross arms,cable protection pipe,brackets etc and applying one coat of synthetic enamel paint alternate yellow & black strips painting (5 nos each strip 300 mm wide) and remaining portion of pole and cross arms,cable protection pipe,brackets etc treated with one coats of Aluminium paint incl writing pole no with white paint on black back ground complete all as specified and as directed
M & L for 4 Pole structure preparing old painted surfaces by scrapping and removing old paints, rust etc from steel tubular poles ( above the planting depth and PCC coping of 11.0 Metre length pole ) and Mild Steel cross arms,cable protection pipe,brackets etc and applying one coat of synthetic enamel paint alternate yellow & black strips painting (5 nos each strip 300 mm wide) and remaining portion of pole and cross arms,cable protection pipe,brackets etc treated with one coats of Aluminium paint incl writing pole no with white paint on black back ground complete all as specified and as directed
Calibration and testing of combined inverse time over current earth fault and instantaneous relay for checking and cleaning and ensure physical healthliness with visual check for healthy tripping of over currect and earth fault setting tripping timer ratio setting instantaneous time setting etc as per installed capacity of transformers with artificial current injenction on primary & secondary with current injection machine complete all as specified and directed.
Dismantling of mechanism system of defecitive 11 KV VCBs/ OCBs, renewal the unserviceable items such as closing/triping coil, spring charging motor etc including overhauling the same after necessary cleaning with CTC, and providing silicon grease to the all moving parts including adjustment of all springs etc and made 100% serviceability complete all as specified and directed. (NOTE :- Spring charging motor shall be measured and paid separately).
Supply only spring charging motor of 230 volts 0.25 HP, 8000 RPM of 11 KV VCB's type VE -12, 30/110 volts complete all as specified and directed.
Supply & fixing in renewal of Current transformer (CT) of 11 KV , single phase indoor type, CT ratio 150/5 Amp , burden 15 VA ,Class 0.5 complete all as specified and as directed.
Supply and fixing in renewal of 3 phase over current and earth fault (IDMT) relay installed on existing panel or separate enclosure, with connecting, internal control wiring , testing complete all as specified and directed ( MAKE :- L&T Model No- MC61A or equivalent model as specified make as approved by AGE(I) )
Supply and fixing in renewal of electronic auxiliary relay type AR111X2 voltage 30 V DC for 33 KV panel ( Make - Model no PC : AR 08138 of EASUN or equivalent model as specified make as approved by AGE(I)
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
M & L for preparation of old painted steel or iron surfaces of transformers of 100 to 500 KVA ,11/0.433 KV capacity transformer by scrapping with steel wire brush /scrapper emery paper etc and applying one coat of synthetic enameled smoke grey/exising colour( painting shall be done by spray machine) including writing of SM No , MES No at prominent place/location of transformer with black synthetic enamel paint in white back ground complete all as specified and directed.
Trimming of tree branches girth not exceeding 50 mm around OH electric lines and cleaning up to 3.00 mtr from the OH electric lines and removing trimmed branches from sites and stacking as ordered complete all as specified and as directed (NOTE : span length approx 45 mtr )
Supply, installation, testing and commissioning in renewal of HT out door type feeder pillar box (factory made and CPRI Type Tested ) , floor mounted, cubical enclosed type, made out from 3.15 mm thick CRCA sheet, of size 1.5x1.2x1.0 m with two part front operated hinged doors, canopy type roof, weather and vermin proof, one closed HT bus bar chamber having 3 phase copper bus bar of size 40 x 5 mm, 15 KA short circuit rating for one second, one GI earth bus fixed out side the bus bar chamber, two nos cable gland suitable for 95 sqmm to 120 sqmm 3.0 core HT XLPE cable with and including HT danger notice board on both sides, frame made out of ISA 50 mm x 50 mm x 6mm with cable entry & exit through socket at bottom (Fixed with cable glands and gasket) for maintaining specific bending radius of cable including providing two coats of powder coated paint to out side surface and two coats of synthetic enamel paint over a coat of red oxide primer to inside surface and necessary foundation/platform of the HT Feeder pillar box with PCC (1:2:4) type B1 (using 20 mm grade stone aggregate). complete all as specified and as directed
M/S VIDIT ENTERPRISES
M/S S P CONSTRUCTION
R.S ENGINEERING TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .