| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.7 LAccepted-AOC VILL PO KOTA VIA PANAGARH BAZAR DIST BURDWAN WB PIN 713148 | BURDWAN | BURDWAN | WEST BENGAL | 713148 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹98.3 L+₹23.5 L (31.5%)Rejected-Finance 1ST FLOOR SIDHARTH TOWER BALTI KHARKHANA BYELNE S J ROAD ATHGAON GUWAHATI KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | L2 | Rejected-Finance Other than Lowest bidder | |
| 3 | L3₹1.1 Cr+₹35.0 L (46.8%)Rejected-Finance VILL SANDIPUR PO DWARNARY DISTT PURBA MEDINIPUR KOLKATA 7134403 WB | KOLKATA | PURBA MEDINIPUR | WB | 7134403 | L3 | Rejected-Finance Other than Lowest bidder |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
9 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CHIEF ENGINEER COAST GUARD VISAKHAPATNAM
OFFICE OF CHIEF ENGINEER COAST GUARD VISAKHAPATNAM-7
PROVN OF 2 NOS STEEL PONTOON AT COAST GUARD JETTY AT HALDIA
2021_MES_419500_3
CE (CG) /VIZ(HALDIA)/TOKEN 17 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
KOLKATA
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer I CG P Kolkata
₹1 L
Yes
3 Aug 2021
7 May 2021
11 Jun 2021
7 May 2021
9 Jun 2021
28 May 2021
60 days
Amount
Schedule "A" Part – I to Schedule "A" Part – IX: NOTE: Schedule "A" Part – I to Part – VIII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Schedule 'A' Part-I NOTE :- (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 signifies this fact only. (ii) Certain items of the items mentioned in this parts are to be executed in water and liquid mud and also interrupted by the tides the rate quoted by the bidders are deemed to be inclusive this aspect. (iii) Any loss or damage of equipments/plants during mobilization in rivers is deemed to be inclusive in the quoted rate.
Providing the temporary support system to existing foot bridge and removal of existing support, as per sound engineering practice and as directed by Eng-in- Charge.
M&L for boring for bored cast in situ piles in any strata for 0.75 mtr dia piles by DMC (Direct Mud Circulation ) method using bentonite slurry and getting out and disposal of spoil to a distance 50 meters, all as specified and directed. Note: a) The rate shall include mobilization, erection, dismantling and demobilization of equipment for pile boring including all labours and materials. Nothing extra shall be payable for mobilization of equipment separately. b) In case the soil strata at founding level is loose, the same to be brought to the notice of GE for further directions. c) The sample of bored materials shall be collected at regular intervals and preserved without any extra cost. d) The depth of boring shall be approximately 30 mtrs.
M&L for RCC Design Mix Concrete (M-40) as in bored cast in situ piles (0.75 mtr dia) 30.00 metres from cut off level with well graded stone chips of 20 mm nominal size ,design mix following IS 10262, and IS 456 and direction to the Engg-in -Charge completed all as specified and directed. Note: a) Reinforcement shall be measured and paid separately under relevant items. b) Concrete shall be measured up to cutoff level for payment purpose. c) The length of pile shall be approximately 30 mtrs.
M&L for RCC Design Mix Concrete (M-40) as in foundation , pile cap, and mass concrete with well graded stone chips of 20 mm nominal size ,design mix following IS 10262, and IS 456 and direction to the Engg-in -Charge completed all as specified and directed including necessary form work and shuttering. Note: a) Reinforcement shall be measured and paid separately under relevant items. b) Concrete shall be measured up to cutoff level for payment purpose. c) The length of pile shall be approximately 30 mtrs.
Rough finished surfaces of concrete, Formwork to sides of concrete foundations, footings, bases of columns, and raft beams, sides and soffits (if any) of foundations and plinth beams and similar works all as specified and directed.
Supplying and laying Polythene film Sheet 150 mm thick, laid on a coat of bitumen primer (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches, all as specified and directed.
Dismantling of Concrete piles of any description and in any position all as directed by Eng-in-charge.
M & L for PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as directed by Eng-in -charge.
M&L for Centering to brick ,stone concrete block or arches of any shape not exc 6.0 meter mean radius for steel shuttering as directed by Eng-in -charge.
S & F 8 mm MS plate liners along with 12 mm thick annular ring at joint including welding for piles, driving, keeping in position, etc including required machinery, tools and plants etc, all as directed.
Removal of temporary supporting system of existing foot bridge and resting existing foot bridge over newly constructed pile cap as per sound engineering practice and as directed by Eng-in- Charge.
Supply fixing and fabricating Fe -410 (W) gde-250 joist ,channel, angle or tee sections ,fixed independently, without connecting plate as directed by Eng-in- Charge..
M&L for CRS/HRS TMT bars conforming to IS-Fe-500 / 500D of dia 10mm and above as in reinforcement to beams, columns, slabs, piles and pile cap etc and cut to length, bent to shape required including cranking bending spirally for hooping for pile foundation hooking ends & binding with & incl MS steel wire (annealed) not less than 0.9mm dia & securing with clips all as specified and directed.
All as per item No 1.13 above but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders.
M&L for testing of pile in initial load test on land all as specified and directed :-
(a) Constructing test piles 0.75 meter dia and 30 meter long including necessary Concrete in M-40 using PPC, minimum cement content 400Kg/Cum, reinforcement and MS Liner all as specified and directed by G.E.
(b) Conducting initial load test on 0.75 meter dia pile to two and half time designed load through approved firm.
(c) M&L for testing of pile 0.75 meter dia in lateral load test on working piles as per I.S.I Specification through approved firms as specified.
(d ) M&L for testing of pile 0.75 mtr dia in routine vertical load test 1.5 time the working load as per I.S.I Specification through approved firms as specified.
BHARAT TRADING CORPORATION
UNIVERSAL TRADING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .