Loading…
Loading…
Tender Value
₹1.6 Cr
EMD Value
₹3.3 L
Closing Date
2 Jun 2026, 1:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
15 conditions · 4 needing a document upload
Clause Regarding GST: (a) All the Bidders/tenderers should ensure that they are GST Compliant and their quoted tax Structure are as per GST LAW.(b) Tenderer Should Furnish their GSTIN numbers representing the States in Which they are registered GST, along with address of Registered Office.(c)The Contract is under GST Act and rules as applicable time to time.
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. Annual Contractual Turnover Data for the Previous 3/4 Years should be submitted as per Annexure-IX.(AnnexureVIB of Tender Documents)
37 conditions · 10 needing a document upload
Check List: The tenderer(s) would fill up the check list, as per Annexure-XXIII to ensure that they are submitting the complete tender offer.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Provision of Air-conditioning system at SM/Indoor, SS Chamber, Booking,PRS & parcel Office at stations over TSK Division.
LV-T-14-TSK-940
LV-T-14-TSK-940
Open
Works - General
8 Months
Tinsukia, Assam
₹0
₹3.3 L
2 Jun 2026
12 May 2026
19 May 2026
29 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,62,66,544 | ||
| — | 187.00 | — | — | ||
| Supply, fitting, fixing of Inverter Split Air Conditioner 1.5 Ton , BEE 5 Star Rated , ISEER: Not less than 5.0, Cooling Capcity: Not Less than 4800 Watts ,Compressor: Rotary, Refrigerant: R32/R290/R410A,5-in -1 supper convertible cooling option, 100% copper tube of condenser coil, operating on 230V AC 50Hz, provided with HD filter and Antivirus protection including required copper connecting pipe & bracket for fixing of outdoor unit on wall. | — | — | — | 82,80,547 | |
| — | 187.00 | — | — | ||
| Supply, fitting, fixing, testing & commissioning of wiring materials for casing capping type wiring for AC point from main/sub-main board to the points by 6 mm sq single core multi-strand FRLHS copper cable through double lock PVC casing capping 25 mm dia including MCB Protected Power Unit 25 A ,modular type having Socket, push Starter and 1.0 mm.sq. unsheathed copper cable in green colour for earth continuity wire. | — | — | — | 3,38,470 | |
| — | 2000.00 | — | — | ||
| Supply, laying of PVC Pipe 20 mm dia(Medium Gauge) with all required accessories. | — | — | — | 87,000 | |
| — | 650.00 | — | — | ||
| Supply, laying of UPVC pipe 20 mmdia Schedule 40 for AC Outlet Pipeline with required Bends, Coupler etc as per direction of Engineer Incharge at Site. | — | — | — | 2,41,800 | |
| — | 4500.00 | — | — | ||
| Supply, laying,connection, testing and commissioning of cable size 16 mm.sq. 4 core ,LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured cable having Aluminium Strip, Glavanised Wire Solid Aluminum Conductor, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. For laying of above cable digging of trench and excavation of earth/concrete to depth 0.75 Mtrs. and breadth 0.5 Mtrs. below the ground level and a layer of sand of 0.075 Mtrs. thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of sand of 0.075 Mtrs. thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. The cable route markers should be provided along the route of cables to indicate their presence so that damage/accident are Not caused by inadvertent digging. As per PCEE DRWG:PCEE/ELG/DRG/2024/2 Dated:04.10.2024 | — | — | — | 25,42,500 | |
| — | 2500.00 | — | — | ||
| Supply, laying,connection, testing and commissioning of cable size 16 mm.sq. 2 core ,LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured cable having Aluminium Strip, Glavanised Wire Solid Aluminum Conductor, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. For laying of above cable digging of trench and excavation of earth/concrete to depth 0.75 Mtrs. and breadth 0.5 Mtrs. below the ground level and a layer of sand of 0.075 Mtrs. thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of sand of 0.075 Mtrs. thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. The cable route markers should be provided along the route of cables to indicate their presence so that damage/accident are Not caused by inadvertent digging. As per PCEE DRWG:PCEE/ELG/DRG/2024/2 Dated:04.10.2024 | — | — | — | 10,67,500 | |
| — | 60.00 | — | — | ||
| Supply, fitting, fixing of Bus Bar Chamber 3 phase and Neutral (4P) with Copper Busbar 100 Amps, 8 way .The busbar chamber to be fabricated using sheet steel (CRCA) of 1.6mm thickness and epoxy powder coated to give superior & lasting finish. The bus bar sections to be made of ETP grade copper & dull tin plated and the bus bar supports are made of DMC (Dough moulding compound). The neutral bus bar to be fully rated. The Bus Bar Chamber should conform to IS:8623/IEC 60439 (Panel sub assemblies) IS: 2147/IEC60529 (Degree for protection) | — | — | — | 10,13,700 | |
| — | 90.00 | — | — | ||
| Supply , fitting fixing of SPN MCB DB Double Door 8 Way, IP 45 with (i) MCB DP 63 A C series-1 No, (ii)MCB DP 32A C series-3 Nos,(iii) MCB SP 10 A C series-2 No | — | — | — | 6,88,500 | |
| — | 2992.00 | — | — | ||
| Supply,Laying ,testing & commissioning of 10 mm.sq. Single Core HRFR PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volt Conforming to IS 694 | — | — | — | 6,31,312 | |
| — | 60.00 | — | — | ||
| Erection of earth by 50 mm dia 3 Mtrs. long (3.6 mm thickness) GI pipe , 6 SWG GI wire,GI nuts, bolts including masonry materials for earthing pit, salt, charcoal etc. and construction of earth pit covered with RCC cover slab 12.7 mm thickness and watering pipe per Drawing No PCEE/ELG/DRG/2024/1 Dtd 30.09.2024 | — | — | — | 2,48,580 | |
| — | 187.00 | — | — | ||
| Supply, fitting, Fixing of Hydrualically regulated Door Closer, tubular Type(Type B) Universal Closer for both clockwise and Anti-Clock wise for Door Weight 36 KG to 60 KG | — | — | — | 3,36,600 | |
| — | 500.00 | — | — | ||
| Supply of copper tube pipe line 1/2"+1/4" copper tube with insulation sleeve with 4core copper cable 1.5 sq.mm suitable for AC units upto 1.5Ton Capacity. | — | — | — | 3,48,500 | |
| — | 30.00 | — | — | ||
| Supply installation of AC Voltage Stablizer 4KVA, Voltage Input Range 110/130-290V AC. equipped with an intelligent high and low voltage cut-off feature Low Voltage Cut -Off at 110VAC, High Voltage Cut Off at 290V AC ,Maximum Load 3.2KW, Digital Display for Voltage, Toroidal Coil | — | — | — | 1,61,970 | |
| — | 187.00 | — | — | ||
| Supply of MCB Protected Power Unit Having DP MCB 25A 10KA BC C series-1 No., 25A Heavy Duty Socket, push starterEnclosed in 6 Module PVC Box and Cover Plate | — | — | — | 2,79,565 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AnexxuresSectionVIINew.pdf
ATTACHMENT
GCCACS11.pdf
ATTACHMENT
TenderDocumentTSK-940_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .