Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC 364 4 FIRDAUS SHABANA MARKET NEW SABZI MANDI JK COLONY ROAD KANPUR 07 | KANPUR NAGAR | UTTAR PRADESH | 208001 | L1 | Accepted-AOC Found reasonable for acceptance | |
| 2 | L2₹17.5 L+₹1.8 L (11.5%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹17.5 L+₹1.8 L (11.7%)Rejected-Finance | L3 | Rejected-Finance L1 being accepted |
Tender Value
₹18.8 L
EMD Value
₹37,600
Closing Date
29 Oct 2024, 6:00 pmClosed
GE (P) Navy Mandovi
GE (P) Navy Mandovi Military Engineer Services INS Mandovi
As per tender documents
2024_MES_677195_1
8554/E8 GE (P) NAVY MANDOVI
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Mandovi
As per tender documents
7 documents required · 7 mandatory
₹500
GE (P) Navy Mandovi
₹37,600
Yes
30 Nov 2024
28 Sept 2024
31 Oct 2024
28 Sept 2024
29 Oct 2024
14 Oct 2024
30 Sept 2024 - 12 Oct 2024
Amount
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc to match existing surface complete all as specified and directed.
Taking down DB, main switch, sheet metal enclosure etc complete all as specified and directed.
Taking down submain wiring complete all as specified and directed.
M & L for point wiring complete with 1.5 Sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor confirming to IS-694, Part II, ISI marked, drawn through and including medium grade PVC conduit of size not less than 25mm dia, ISI marked with all accessories, concealed in wall/ ceiling, pressed steel terminal boxes firmly fixed with pipe /wall including concealed GI sheet metal box (rust protected), suitable modular frame with cover fixed with chromium plated brass screws for fixing switches, sockets, regulators etc., and including providing 1.5 sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor in green colour as earth continuity conductor connected to common earth dolly for the following complete all as specified and directed. Note: Quoted rate shall be deemed to be inclusive of cutting chasis in wall/ floor/ ceiling and making good disturbed surface with PCC work and paint etc.
One light point controlled by one switch
One light point controlled by two two-way switches
One ceiling/ exhaust fan point controlled by one switch
One switch socket combination 5 Amp on same board with other switches
One switch socket combination 5 Amp on independent board
One bell point controlled by one bell push
M & L for point wiring complete with 2.5 Sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor confirming to IS-694, Part II, ISI marked, drawn through and including medium grade PVC conduit of size not less than 25mm dia, ISI marked with all accessories, concealed in wall/ ceiling, pressed steel terminal boxes firmly fixed with pipe /wall including concealed GI sheet metal box (rust protected), suitable modular frame with cover fixed with chromium plated brass screws for fixing switches, sockets, regulators etc., and including providing 2.5 sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor in green colour as earth continuity conductor connected to common earth dolly for one 15 Amps switch socket combination on independent board complete all as specified and directed. Note: Quoted rate shall be deemed to be inclusive of cutting chasis in wall/ floor/ ceiling and making good disturbed surface with PCC work and paint etc.
S & F in repairs modular switch 1 way 6A, 1 module, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs modular switch 2 way 6A, 1 module, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs modular switch 1 way 16A, 1 module, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs call bell, buzzer/ ding dong, for 240V 50Hz AC supply complete all as specified and directed.
S & F in repairs modular bell push 6A, 1 module complete all as specified and directed.
S & F in repairs modular socket 6A, 3 pin 2 module, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs modular socket 15A, 3/5 pin, 2 module, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs modular fan regulator, eletronic step type, 120 watt, 2 module, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs LED tube light fitting 1 X 20 watt, 220V AC, integrated integral sleek extruded polycarbonate LED channel with white acrylic cover alongwith LED batten, including connecting with three core flexible copper conductor cable of suitable size from ceiling rose to fitting duly mounted on PVC block with steel screw & sleeves complete all as specified and directed.
S & F in repairs LED tube light fitting 1 X 10 watt, 220V AC integrated integral sleek extruded polycarbonate LED channel with white acrylic cover alongwith LED batten, including connecting with three core flexible copper conductor cable of suitable size from ceiling rose to fitting duly mounted on PVC block with steel screw & sleeves complete all as specified and directed.
S & F in repairs square/round shaped LED light fitting, 15 watt, 220 volts AC, recessed type with high efficiency PMMA diffuser for fixing in false ceiling, soft glare free, with drivers including connecting with three core flexible copper conductor cable of suitable size to existing supply complete all as specified and directed.
M & L for preparation of old painted surfaces of ceiling fan and spray painting one coat of synthetic enamel paint, marking MES number on body of the fan, including taking down, refixing, connecting and testing complete all as specified and directed.
S & F in repairs ceiling rose, 2 to 3 terminal, surface bakelite, 65X50 mm, complete all as specified and directed.
S & F in repairs MCB SP 6 to 32 Amps, 'C' series, suitable for 230 volts 50 Hz AC supply complete all as specified and directed.
S & F in repairs MCB SPN 32 Amps, 'C' series, suitable for 230 volts 50 Hz AC supply complete all as specified and directed.
S & F sheet metal enclosure for MCB's (D.B), double door, SPN 8 way with IP-42 protection, suitable for 230 volts 50 Hz AC supply including concealing suitably in wall complete all as specified and directed.
S & F sheet metal enclosure for MCB's (D.B), double door, SPN 4 way with IP-42 protection, suitable for 230 volts 50 Hz AC supply including concealing suitably in wall complete all as specified and directed.
S & F sheet metal enclosure for MCB's (D.B), double door, vertical type, TPN 4 way, with IP-42 protection, suitable for 415 volts 50 Hz AC supply including concealing suitably in wall complete all as specified and directed.
S & F in repairs MCB TP 63 Amps, 'C' series, suitable for 415 volts 50 Hz AC supply complete all as specified and directed.
S & F in repairs MCB TPN, 4-pole, 63 Amps, 'C' series, suitable for 415 volts 50 Hz AC supply complete all as specified and directed.
S & F MCCB distribution board (DB), vertical, double door, TPN 6 way, with suitable rated bus bar including MCCB, 125 Amps, 4 pole 16 kA alongwith connections including concealing suitably in wall complete all as specified and directed.
S & F in repairs MCCB 3 pole 125 Amps, 415 Volts for 3 phase 50 Hz, 16 kA breaking capacity, Ics=Icu= 100% with thermal, magnetic and microprocessor adjustable type, complete all as specified and directed.
S & F in repairs exhaust fan, 300 mm sweep single phase 230/240 volt AC supply 50 HZ, metal body, complete with louvers and shutters of aluminium and iron, fixed with suitable MS Bracket, nuts, bolts and fixing arrangement, including making/ resizing holes and PCC work as per site requirement and depositing old unsv fan in MES store complete all as specified and directed.
S & F in repairs exhaust fan, 250 mm sweep single phase 230/240 volt AC supply 50 HZ, made of sturdy engineered plastic complete with louvers and shutters, fixed with suitable MS Bracket, nuts, bolts and fixing arrangement, including making/ resizing holes and PCC work as per site requirement and depositing old unsv fan in MES store complete all as specified and directed.
M & L for providing submain wiring with two runs of 6 sqmm single core multistranded PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 6 sqmm single core PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including rigid PVC conduit of suitable dia concealed in wall/ceiling with all accessories such as tees, elbows, junction boxes, reducers etc as required, connecting to existing main switch board/ distribution board and testing on completion and making good disturbed surfaces and painting to match with existing surface complete all as specified and directed. Note: Two runs of 6 Sqmm cable, one run of 6 Sqmm earth wire and one run of PVC conduit shall be measured as unit length.
M & L for providing submain wiring with two runs of 4 sqmm single core multistranded PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 4 sqmm single core PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including rigid PVC conduit of suitable dia concealed in wall/ceiling with all accessories such as tees, elbows, junction boxes, reducers etc as required, connecting to existing main switch board/ distribution board and testing on completion and making good disturbed surfaces and painting to match with existing surface complete all as specified and directed. Note: Two runs of 4 Sqmm cable, one run of 4 Sqmm earth wire and one run of PVC conduit shall be measured as unit length.
M & L for providing submain wiring with four runs of 10 sqmm single core multistranded PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 10 sqmm single core PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including rigid PVC conduit of suitable dia concealed in wall/ceiling with all accessories such as tees, elbows, junction boxes, reducers etc as required, connecting to existing main switch board/ distribution board and testing on completion and making good disturbed surfaces and painting to match with existing surface complete all as specified and directed. Note: Four runs of 10 Sqmm cable, one run of 10 Sqmm earth wire and one run of PVC conduit shall be measured as unit length..
S & F sheet metal enclosure earth plug and socket, single pole and neutral with two pin including one single pole MCB 20 Amps 240 Volts complete all as specified and directed.
S & F LED building light fitting, 45 watts for 230 V 50 Hz AC supply, with electronic driver and all accessories internally prewired, and connecting with existing feeder/ junction box/ ceiling rose including provn of 1.5 sqmm 3 core copper multistranded conductor cable through and suitable fixing arrangement to fix on the wall metal/aluminium body with bolts, nuts and washers complete all as specified and directed.
Taking down split AC indoor unit including pumping down and locking refrigerant, disconnecting voltage stabilizer and all electrical & refrigerant connections, keeping in safe custody without damaging indoor unit body and refixing in same location after completion of entire electrical work including reconnecting all connections and testing complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground, earth pit not less than 2.25 m below ground level, with top edge of plate not less than 1.5 m below ground level, connected to 4mm dia GI earth wire by means of bolts, nuts, check nuts and washers of galvanised steel including neccessary earthwork and excavation in any strata, PCC chamber in PCC 1:3:6 type C2, 20 mm dia light grade GI pipe for protection of earth strip and GI wire, chamber cover etc all as per electrical plate No. 3 of SSR Part-I including connections with earth testing point and taking down old earthing complete all as specified and directed. Note: On testing after completion if the desired earth resistance is not obtained, earthing shall be redone at no extra cost.
INDIAN AIR CONDITIONING SERVICES (BID ID -3143095)
N VENKATESWARLU (BID ID -3152579)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .