Loading…
Loading…
Tender Value
Refer Docs
Closing Date
27 Aug 2026, 3:00 pm4d left
SEKAR HIRUDHAYAM
TECHNIP ENERGIES INDIA LIMITED, CHENNAI
SUPPLY OF ASSET PERFORMANCE MANAGEMENT SYSTEM (APMS) FOR NUMALIGARH REFINERY EXPANSION PROJECT
2026_NRL_913590_1
TP/082176C/NRL/PQ/151
Open Tender
Electrical Goods/Equipment
Supply
240 days
NUMALIGARH
Please refer tender Documents
8 documents required · 8 mandatory
₹0
Exempted
ONLINE
27 Aug 2026
18 Jun 2026
28 Aug 2026
18 Jun 2026
27 Aug 2026
14 Jul 2026
25 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Design, engineering, manufacturing, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturer's works & packing, training to owner engineers, supervision of installation, transportation to site of the items listed in Part-I of MR, including supply of all mandatory spares, commissioning spares & special tools and tackles, first fill of consumables, erection material & documentation as specified in the Specification & documentation as per job specification, system architecture etc. and other codes and standards attached or referred in Material Requisition. MR Ref:TP-1ZZZA-EL-RFQ-0016_D1 | |||||
| 1.01 | CENTRAL CONTROL AND SUPERVISORY SYSTEM
DESIGN, ENGINEERING, SUPPLY, TESTING, SITE INTEGRATION, PRE-COMMISSIONING & COMMISSIONING ACTIVITES,SUPPLY OF SPECIAL TOOLS AND TACKLES (AS PER MANUFACTURER RECOMMENDATION FOR APMS),SUPPLY OF PRE-COMMISSIONING,COMMISSIONING AND START-UP SPARES (AS PER MANUFACTURER'S RECOMENDATION FOR APMS), FACTORY ACCEPTANCE TESTING (FAT) AND SITE ACCEPTANCE TEST (SAT) AS PER MR: TP-1ZZZA-EL-RFQ-0016.
Commodity Code: 166100 | 1 | LOT | - | - |
| 1.02 | MANDATORY / CAPITAL SPARE PARTS
Supply of Mandatory spares as per Spare parts - Special tools and consumables philosophy Annexure-4 “TP-1ZZZA-PQ-PRC-0005” for Asset Performance Management System | 1 | LOT | 100 | ₹100 |
| 1.03 | Training to 2 Nos. of Owner personnel at OEM’s factory for 10 days for the entire Package
Note:The quoted charges shall include travel, Boarding, Lodging, local transport, medical, all insurance including third party, income tax, all taxes & all other incidental charges. However, the actual man days consumed shall be considered for payment. | 10 | Per Diem | 53 | ₹530 |
| 1.04 | Training to 10 Nos. of Owner personnel at NREP Site for 10 days for the entire Package
Note:The quoted charges shall include travel, Boarding, Lodging, local transport, medical, all insurance including third party, income tax, all taxes & all other incidental charges. However, the actual man days consumed shall be considered for payment. | 10 | Per Diem | 10 | ₹100 |
| 1.05 | Supervision services for Installation of the entire package from OEM for 5 days
Note:The quoted charges shall include all travel, boarding, lodging, local transport, medical, all insurance including third party, income tax, all taxes & all other incidental charges. The actual man days consumed shall be considered for payment. | 5 | Per Diem | - | - |
| 1.06 | Bidder shall provide Per Diem rate for supply of Commissioning / Support Engineer from OEM who shall be stationed at NREP Site for the duration of 1 month from the date of commissioning & handover for the entire package
Note:The quoted charges shall include travel, Boarding, Lodging, local transport, medical, all insurance including third party, income tax, all taxes & all other incidental charges. However, the actual man days consumed shall be considered for payment. | 30 | Per Diem | 11 | ₹330 |
| 1.07 | Third Party Inspection (TPI) Charges
Note:Third Party Inspection Agency (TPIA) shall be engaged by Bidder from OWNER approved list of TPIA Agencies and charges related to TPIA shall be included by Bidder. | 1 | Lumpsum | 10 | ₹10 |
| 1.08 | Additional Warranty period of “24 months after commissioning or 36 months after dispatch whichever is earlier” over and above the standard warranty period. | 1 | Lumpsum | 22 | ₹22 |
| 1.09 | Supply of AC UPS SYSTEM (SS10), 115V,100% Parallel Redundant UPS with Common Bypass.
115V,50Hz, 20kVA, 1Ph, 0.8pf, AC UPS system consisting of 2x100% parallel redundant configuration with common bypass, including Condition monitoring as detailed in the specification TP-1ZZZA-EL-SPE-0017 & Cell booster, as per typical SLD & as per requisition documents and shall include testing after erection, pre-commissioning & commissioning.
Tag No:1U64-SS10-UPS-501 | 1 | EA | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
ATC_BID_DOCUMENT_ANNEXURES.xls
Tender Documents • 2.39 MB
Part_II_Technical_Bid_Documents.pdf
Tender Documents • 21.90 MB
Part_I_Commercial_Bid_Documents.pdf
Tender Documents • 34.37 MB
BOQ_960105.xls
BOQ • 0.34 MB
CORRIGENDUM_04_COMMERCIAL.pdf
PDF • 0.13 MB
151_SUPPLY_OF_APMS_Pre_Bid_Queries_Responses_04.pdf
PDF • 0.08 MB
CORRIGENDUM_03_COMMERCIAL.pdf
PDF • 0.13 MB
151_SUPPLY_OF_APMS_Pre_Bid_Queries_Responses_03.pdf
PDF • 0.15 MB
CORRIGENDUM_02_COMMERCIAL.pdf
PDF • 0.13 MB
151_SUPPLY_OF_APMS_Pre_Bid_Queries_Responses-2.pdf
PDF • 0.10 MB
151_Pre_Bid_Meeting_MOM.pdf
PDF • 0.10 MB
151_SUPPLY_OF_APMS_Pre_Bid_Queries_Responses.pdf
PDF • 0.22 MB
ADDENDUM_01_COMMERCIAL_APMS.pdf
PDF • 0.31 MB
CORRIGENDUM_01_COMMERCIAL.pdf
PDF • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].