| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 CrAccepted-AOC | ₹37.8 Cr Quoted ₹37.5 Cr | L1 | Accepted-AOC As per AOC |
| 2 | L2₹38.5 CrRejected-Finance | ₹38.5 Cr | L2 | Rejected-Finance Highest Rate Quoted |
| 3 | L2₹38.9 CrRejected-Finance HARSH ANAND YEVALEKAR MALA COLLEGE ROAD NASHIK 422005 | NASHIK | NASHIK | MAHARASHTRA | 422005 | ₹38.9 Cr | L2 | Rejected-Finance Highest Rate Quoted |
| 4 | Rejected-Technical | - | - | Rejected-Technical Due to technically disqualified |
Tender Value
Refer Docs
EMD Value
₹19 L
Closing Date
19 Jul 2021, 2:00 pmClosed
Addl. Chief Executive Officer
Zilla Parishad Aurangabad
Construction of Zilla Parishad Administrative Building Aurangabad (Civil Works including Dismentling Old Buildings, Electrical Works, Fire Fighting etc)
2021_AURAN_698035_1
ZPA/Works/AB/2021
Open Tender
Civil Works - Buildings
900 days
Aurangabad
As per Tender Details
3 documents required · 3 mandatory
₹3,540
₹19 L
Addl. CEO Office
29 Sept 2021
24 Jun 2021
20 Jul 2021
24 Jun 2021
19 Jul 2021
13 Jul 2021
24 Jun 2021 - 12 Jul 2021
12 Jul 2021
Amount
PART A - WORK PORTION
1) DISMENTALING
Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete. As directed by Engineer incharge. S.S.R No.46.14 I.No.1532, Page No.283
Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. As directed by Engineer incharge. S.S.R No.46.29 I.No.1545, Page No.284
Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete..INo. As directed by Engineer in charge. SSR No.38.26 I.No.1159, Page No.226
Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. As directed by Engineer incharge. S.S.R No.46.15 I.No.1533, Page No.283
Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete.INo. As directed by Engineer in charge. SSR No.46.16 I.No.1534, Page No.284
Removing wooden or A.C. partition including frame work and stack-ing the materials as with all leads, lifts etc. complete..INo. As directed by Engineer in charge. SSR No.46.17 I.No.1535, Page No.284
Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc complete.INo. As directed by Engineer in charge. SSR No.46.40 I.No.1556, Page No.285
Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete.INo. As directed by Engineer in charge. SSR No.46.41 I.No.1557, Page No.285
Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc.As directed by Engineer incharge. S.S.R No.46.09 I.No.1527, Page No.283
Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete INo. As directed by Engineer in charge. SSR No.46.19 I.No.1537, Page No.284
Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. As directed by Engineer incharge. S.S.R No.46.12 I.No.1530, Page No.283
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 500 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means INo. Bd.A.1 Page No.259 SSR No.21.02 I.No.714, Page No.148
Dismentaling
Ground Floor
Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc. As directed by Engineer incharge. S.S.R No.46.11 I.No.1529, Page No.283
2) ADMIN BUILDING - MAIN
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means. Spec.No.: Bd.A.2 Page Number 259 SSR I.No.21.04, Sr.No.716 P.No.148
Ground Floor
Conveying materials obtained from road cutting including all lifts, for a lead of over 12km. inclusive from the site of excavation to the site of deposition as directed. Spec. No. MORTH 305 SSR I.No. 2.25, Sr.No. 98 P.No.28
Ground Floor
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Spec. No. Bd.A.11 Page Number 263. SSR I.No. 21.37, Sr.No. 744, P.No. 152
Ground Floor
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No. As directed by Engineer in charge. SSR I.No. 21.40, Sr.No. 747, P.No. 152
Ground Floor
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. Spec. No. d.C.8 Page Number 278. SSR I.No.23.04, Sr.No.812, P.No.167
Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. Bd.E.1 Page No. 287.SSR I.No.24.01, Sr.No.820, P.No.169
Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Sepc. No. Bd.E.4 Page Number 289 and B-7, Page Number38, Page No. 38 .SSR I.No. 24.10, Sr.No. 824, P.170
Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for plain or molded sills, cornice, jambs, block in course, or architraves of required size and shapes including steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided,finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer etc. complete, With fine aggregate (Crushed sand VSI Grade) Sepc. No. Bd.E. 5/Page Number 290/I.S. 456 (2000). SSR I.No. 24.15, Sr.No. 827, P.171
First Floor
Second Floor
Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Spec No. : Bd.E. 3/ Page No.288/ I.S. 456 (2000).SSR I.No.24.16, Sr.No.828, P.No.171
Ground Floor
Terrace Floor
roviding and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No.Bd.F.3 Page No. 298 and B.7, Page No.38. SSR I.No.25.13, Sr.No.830 P.No.172
Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. : Bd.F.5 Page No. 300 and B.7, Page.No. 38.SSR I.No.25.33, Sr.No.835, P.No.174
Ground Floor
First Floor
Second Floor
Third Floor
Terrace Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. Bd.F.6 Page No. 300 and B.7, Page No.38.SSR I.No.25.52, Sr.No.840, P.No.175
Ground Floor
First Floor
Second Floor
Third Floor
Terrace Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec No.Bd.F.8 Page No. 302 and B.7, Page No.38. SSR I.No.25.72, Sr.No.845 P.No.176
Ground Floor
First Floor
Second Floor
Third Floor
Terrace Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap /granite / gneiss/ quartzite metal for R.C.C. arches with skew backs as per detailed design and drawings or as directed including steel centering, plywood/steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement, including cover block). Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed) With fine aggregate (Crushed sand VSI Grade) Spec.No. Bd. F. 15 Page Number 306 /I.S. 456 (2003) SSR I.No.26.30, Sr.No.861, P.No.181
Fifth Floor
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). Spec.No. Bd.F.9 Page No. 303 and B.7, Page No.38.SSR I.No.26.07, Sr.No.850, P.No.178
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite / quartzite / gneiss metal for R.C.C. canopy as per detailed designs and drawings including steel centering, formwork, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing etc. complete (excluding reinforcement). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. Bd.F.8 Page No. 303 and B.7, Page No.38 SSR I.No.26.11, Sr.No.852 P.No.178
Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. Bd.F.11 Page No. 304 and B.7, Page No. 38.SSR I.No.26.19, Sr.No.854, P.No.179
Ground Floor
First Floor
Second Floor
Third Floor
Terrace Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec.No.Bd. F. 13 Page No. 305 / I.S. 456 (2000..SSR I.No.26.26, Sr.No.857, P.No.180
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.Spec.No. Bd.F.17, Page No. 306. SSR I.No.26.33, Sr.No.864, P.No.182
Ground Floor
First Floor
Second Floor
Third Floor
Terrace Floor
Providing expansion joints in R.C.C. framed structure (interior column) with plain premoulded filler 25 mm thick including fixing T.W. battens on both faces and finishing as directed etc. Complete. Spec.No. Bd.K.1 Page Number 359. SSR I.No.30.01, Sr.No.919, P.No.195
Ground Floor
First Floor
Second Floor
Third Floor
Providing expansion joints in R.C.C. framed structure (exterior Columns) with plain premoulded filler 25 mm thick and 3 mm thick alluminium plate, hold fast, fixing T.W. battens on internal face, finishing etc. complete as directed. Spec.No. Bd.K.1 Page Number 359. SSR I.No.30.02, Sr.No.920, P.No.195
Ground Floor
First Floor
Second Floor
Third Floor
Providing expansion joints in R.C.C. framed structure (at floor level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bitumen poured filler and fixing T.W. battens on rear faces etc. complete as directed. Spec.No. Bd.K.1 Page Number 359. SSR I.No.30.03, Sr.No.921, P.No.195
Ground Floor
First Floor
Second Floor
Third Floor
Providing expansion joints in R.C.C. framed structure (at terrace level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bituminous poured filler, fixing lead, flashing on upper side and T.W. battens on inner face finishing etc. Complete as directed. Spec.No. Bd.K.1 Page Number 359. SSR I.No.30.04, Sr.No.922, P.No.195
Third Floor
Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.Spec. No. As director by engineer in charge and BDG- 2 and 5. SSR I.No.27.12, Sr.No.892 P.No.190
Ground Floor
Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Spec. No. As director by engineer incharge and BDG- 2 and 5. SSR I.No.27.13, Sr.No.893 P.No.190
Ground Floor
First Floor
Second Floor
Third Floor
Terrace Floor
Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete.Spec. No. Bd. G.7 Page 316. SSR I.No.27.14, Sr.No.894 P.No.190
Ground Floor
First Floor
Second Floor
Third Floor
Providing & laying water proof treatment of terrace slab with B.B. Coba in all position with an average thickness of 150mm consisting specialised materials as per the manufactures specifications and covering 10 years guarantee on court fee stamp paper including all lead, lift, etc. complete.Spec. No. : As directed by Engineer in charge. SSR I.No.48.18, Sr.No.1609, P.No.298 (SSR 2020-21 GREEN BUILDING)
Second Floor
Third Floor
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.Spec.No.: As directed, by the Engineer in charge. SSR I.No.31.05, Sr.No.934 P.No.197
First Floor
Second Floor
Third Floor
Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively, VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer's specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc, washing with water all complete.The contractor shall give guarantee for the performance of SRI and also the durabitity of coating, all complete as per direction of Engineer - in- incharge.as per direction of Engineer - in- incharge. Spec. No. : As directed by Engineer in charge. SSR I.No.48.19, Sr.No.1610 P.No.299 (SSR 2020-21 GREEN BUILDING)
Second Floor
Third Floor
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete ) Spec. No. : Bd.J.2 Page Number 355. SSR I.No.31.12, Sr.No.941, P.No.198
Ground Floor
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) Spec. No. : Bd.J.2 Page Number 355. SSR I.No.31.13, Sr.No.942, P.No.199
Ground Floor
Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge) Spec. No. : As directed by Engineer-incharge SSR I.No.51.192, Sr.No.2020, P.No.396
Ground Floor
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.Spec. No. : Bd. L.2 Page Number 368. SSR I.No.32.03, Sr.No.950, P.No.201
Ground Floor
First Floor
Second Floor
Third Floor
Terrace Floor
Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete Spec. No. : Bd.L.4 Page No. 368. SSR I.No.32.06, Sr.No.953, P.No.201
Ground Floor
Providing and applying plaster / wall punning with plaster of paris ( with plaster of paris material of Ambuja / Mor Chap or equivalent make ) in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. A Spec. No. : Bd.L.4 Page No. 203. SSR I.No.32.30, Sr.No.974,
Ground Floor
First Floor
Second Floor
Third Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.Spec.No.: Bd.L. 7 Page No. 369.SSR I.No.32.11, Sr.No.956 P.No.201
Ground Floor
First Floor
Second Floor
Third Floor
Terrace Floor
Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete. Spec.No.: As directed by Engineer in charge. SSR I.No.32.32, Sr.No.976 P.No.203
Ground Floor
First Floor
Second Floor
Third Floor
Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. Spec. No. : As directed by Engineer in charge. SSR I.No.32.21, Sr.No.965, P.No.202
Ground Floor
Providing patti/ band 75mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete.Spec. No. Bd.L. Page No. SSR Sr.No.967 / I.No.32.23, P.No.202
Ground Floor
First Floor
Second Floor
Third Floor
Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete.Spec. No. As directed by Engineer in charge. SSR I.No.32.24, Sr.No.968, P.No.202
Ground Floor
First Floor
Second Floor
Third Floor
Providing patti/ band 150mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3\ line and level including neat finishing scaffolding curing etc. complete.Spec. No. : As directed by Engineer in charge. SSR I.No.32.25, Sr.No.969, P.No.202
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete.Spec No.: As directed by Engineer in charge. SSR I.No.32.26, Sr.No.970, P.No.202
Ground Floor
First Floor
Second Floor
Third Floor
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.Spec No.: As directed by Engineer in charge. SSR I.No.32.34, Sr.No.978, P.No.203
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing false ceiling with eco-friendly light-weight calcium silicate tiles of spintone surface texture aerolite make or equivalent of size 595mm x 595mm having 15mm thick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600x600mm made from hot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, main T runner of size 42mmx14mm between main tee 600mm center-tocenter and secondary cross T of size 33x14x0.43mm thick of length 600mm long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200mmx600mm resting on periphery wall Profile wall section 19mm (7+7) x 19mmx0.40thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6mm dia and 50mm long dash fastener, 4mm dia G.I. adjustable rods with powder- coated/good quality G.I. level adjustment clips of 35x35x0.8mm spaced @1200, center-to- center along main T all complete at all heights as per the specifications, drawings and as per SSR I.No.38.40, Sr.No.1173, P.No.229
Ground Floor
First Floor
Second Floor
Third Floor
Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete.Spec. No. As directed by Engineer in charge. SSR I.No.32.37, Sr.No.980, P.No.204
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness, and confirming to IS 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Spec. No. Bd. M-12 page Number 388. SSR I.No.33.61, Sr.No.1040 P.No.212
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying vitrified stone effect finish tiles having size 590 to 605 mm x 590 to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including required position laid on a bed of 1:4 cement mortarincluding neat cement float, filling joints, curign and cleaning etc. complete. Spec. No. Bd.M.12 Page No. 385. SSR I.No.33.47, Sr.No.1027 P.No.210
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 mm thickness of having a strength of 400 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. (using 100% crushed sand). Spec. No. : Bd.M. SSR I.No.33.54, Sr.No.1034, P.No.211
Ground Floor
Providing and laying ceramic tiles of having size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. Spec. No. : Bd.M.13 Page No. 386.SSR I.No.33.25, Sr.No.1005 P.No.207
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.Spec. No. :Bd. M-12 page No. 385.DSR Item I.No.33.67, Sr.No.1044, P.No. 212
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Spec. No. Bd.M.3 Page No.380.SSR I.No.33.06, Sr.No.986 P.No.205
Ground Floor
First Floor
Second Floor
Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Flooring Spec. No. As directed by Engineer in charge. SSR I.No.33.28, Sr.No.1008 P.No.208
Ground Floor
First Floor
Second Floor
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.Spec No.:As directed by Engineer in charge. SSR I.No.33.18, Sr.No.998, P.207
Ground Floor
Providing, laying and fixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 mm thick bayer colour pigmented as per IS ..1237 - 1980 having compressive strength more than 500 Kilogram/sq.cm reaffirmed in 2006 ,having wert transvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm ,skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300 in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring. Spec. No. Bd.M. 3 B/Page Number 380. SSR I.No.33.76, Sr.No.1014 P.No.208
Ground Floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Spec. No. Bd.M. 3 B/Page Number 380. SSR I.No.33.34, Sr.No.1014 P.No.208
Ground Floor
First Floor
Second Floor
Third Floor
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. Spec. No. As directed by Engineer in charge. SSR I.No.33.56, Sr.No.1038 P.No.211
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Spec No.:Bd. M.22 B/Page Number 390. SSR I.No.33.35, Sr.No.1015, P.208
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete. One side polish Spec No.: Bd.M.35 B/Page Number393. SSR I.No.33.37, Sr.No.1018, P.209
Ground Floor
First Floor
Second Floor
Third Floor
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Spec. No. : As directed by Engineer in charge. SSR I.No.35.21, Sr.No.1083 P.No.216
Ground Floor
First Floor
Second Floor
Third Floor
Providing and applying plastic emulsion paint of approved quality, colour and shade to new surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete.Spec. No. : Bd.P.6 Page No. 414 and Preapproval of Superintending Engineer. SSR I.No.36.14, Sr.No.1102 P.No.219
Ground Floor
First Floor
Second Floor
Third Floor
Providing and applying 2 coats of 100% Pure acrylic low VOC and APEO & HCHO free water based paint of approved colour that belongs to class 1 flame spread resistance of approved make Paint should provide durable and long lasting silk finish with a high crack tolerance of upto 1mm. Paint should have an oustanding washability with high resistance to wide range of bacteria and fungus. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC Primer. The work activity should cover all aspects of applying paints from surface preparation as directed by Engineer in charge. Spec. No. : As directed by Engineer in charge. SSR I.No.48.11, Sr.No.1602, P.No.297 (SSR 2020-21 GREEN BUILDING)
Ground Floor
First Floor
Second Floor
Third Floor
Providing and applying 2 Coats of 100% Pure acrylic water based paint with special heat reflectance property to withstand the harsh climate for period of atleast 10 years of approved make. Paint system should provide durable and long lasting finish with DFT of min 90 microns and should protect against concrete carbonation with R value of minimum 600 and equivalent concrete layer thickness value of min 150 cm. Paint should have breathability property and should be able to cover hairline cracks in the surface upto 0.5mm The paint has to be applied on a coat of high quality acrylic copolymer based alkali resistant primer with excellent penetrating properties including cleaning, with all leads and lifts at all levels etc complete, as directed by Engineer in charge.Spec. No. : As directed by Engineer in charge. SSR I.No.48.12, Sr.No.1603, P.No.297 (SSR 2020-21 GREEN BUILDING)
Ground Floor
First Floor
Second Floor
Third Floor
Terrace Floor
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Spec. No. : As directed by Engineer in charge. SSR I.No.50.79, Sr.No.1788, P.No.335
Ground Floor
First Floor
Second Floor
Third Floor
Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete.Spec. No. Bd.0.5 Page No. 405..SSR I.No.35.07, Sr.No.1070 P.No.215
Ground Floor
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. Spec.No.As directed by Engineer in charge. SSR I.No.39.01, Sr.No.1186 P.No.205
Ground Floor
Second Floor
Third Floor
Providing and fixing Country teak wood Four leaf paneled shutters, 35 mm thick style and rail and 25 mm thick panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete Spec.No. As directed by Engineer in charge. SSR I.No.39.96, Sr.No.1284 P.No.252
Ground Floor
Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete. Spec.No. BD-T-11 and 12 Page Number 482-83. SSR I.No.39.08, Sr.No.1193 P.No.205
Second Floor
Third Floor
Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.Spec. No. BD-T-34 Page No. 499. SSR I.No.39.09, Sr.No.1194 P.No.236
Ground Floor
First Floor
Second Floor
Third Floor
Terrace Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete.Spec. No. : As directed by Engineer in charge. SSR I.No.39.68, Sr.No.1257 P.No.248
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing fiber glass reinforced polyster door shutter 35 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete. Spec. No. : As directed by Engineer in charge. SSR I.No.39.59, Sr.No.1249 P.No.247
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/Running metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/Running metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising with box. Spec. No. : As directed by Engineer in charge..SSR I.No.39.37, Sr.No.1222 P.No.240
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight o.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box Spec. No. : As directed by Engineer in charge. SSR I.No.39.41, Sr.No.1226 P.No.242
Ground Floor
First Floor
Second Floor
Third Floor
Sliding Window- 3 Track (2 Glass shutter + 1 flymesh) of approved make with DGU, providing and fixing of Sliding Window- 3 Track (2 Glass shutter + 1 flymesh ). For details refer to Specifications. As directed by Engineer in charge. Spec. No. : As directed by Engineer in charge. SSR I.No.39.43, Sr.No.1228 P.No.243
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete.Spec. No. As directed by Engineer-In- Charge. SSR I.No.33.68, Sr.No.1045 P.No.212
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 100 mm .Spec. No. As directed by Engineer in harge. SSR I.No.39.56, Sr.No.1246 P.No.246
Terrace Floor
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear) Spec.No.BD-T-55 Page Number 510 SSR I.No.39.25, Sr.No.1210 P.No.238
Ground Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.Spec. No. : Bd.U. 1 Page No. 537. SSR I.No.40.01, Sr.No.1285 P.No.253
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting, necessary welding, grinding , finishing, buffing to stainless steel pipe etc. complete Spec No.:As directed by Engineer Incharge.SSR I.No.40.07, Sr.No.1291 P.No.253
Ground Floor
First Floor
Second Floor
Third Floor
Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 mm and of DIA: 32MM and thickness 1.5mm of the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of IZE-600MM (H) X 600MM (D) and 32MM DIA. and thickness mm of the approved brand and make. 27c) Straight grab bar (2 NOS) Providing S.STEEL 304 GRAB RAIL (600 MM),32MM DIA. and thickness 1.5mm of the approved brand and make. Spec No.:As directed by Engineer Incharge.SSR I.No.51.89, Sr.No.1900 P.No.363
Ground Floor
First Floor
Second Floor
Third Floor
Providing and Fixing 32 mm thick One piece single moulded puff ABSTRONE BUTADYNE STYRINE (ABS) Door shutter for internal use including toilets made up of outer ABS sheet of 1.2 mm thick having puff insulation of 35 to 40 Kilogram/Cubic Metredensity and 10 mm dia.for steel bars 2 Nos., wooden block etc. complete Spec No.:As directed by Engineer Incharge.SSR I.No.39.80, Sr.No.1269, P.No.250
Third Floor
Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm centerto-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/Square Metre) Spec No.:As directed by Engineer Incharge.SSR I.No.38.34, Sr.No.1167 P.No.227
Third Floor
Providing and fixing shutter to wall cupboard made from 19 mm thick Teak particle board with approved coloured laminated face 1.5 mm thick bonded with phenol formaldehyde synthetic resin B.W.P. grade including lipping beading iron oxidised fixtures and fastening and oil primer coat etc. complete. (Excluding cupboard frame).Spec No.:As directed by Engineer in charge. SSR I.No.37.21, Sr.No.1128, P.222
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.SSR I.No.48.27, Sr.No.1618, P.No.300 (SSR 2020-21 GREEN BUILDING)
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing 25mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [Without chamber]. Spec. No. :Bd.V.7 Page No. 554.SSR I.No.41.28, Sr.No.1323, P.no.258
Ground Floor
Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete.Spec. No.: Bd.V. 8 Page No. 554..SSR I.No.41.40, Sr.No.1328, P.No.258
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing 20 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. Bd.V.8 Page No.554..SSR I.No.41.41, Sr.No.1329, P.No.258
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete Bd.V.9 Page No.555.SSR I.No.41.43, Sr.No.1331 P.No.259
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing push cock (Self closing tap) symet type of 15 mm dia. Including necessary socket, testing etc. complete.Spec No.:As directed by Engineer in charge. SSR I.No.41.54, Sr.No.1342, P.No.259
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing coloured glazed earthenware Wash Hand Basin of 63 cm x 45 cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Spec. No. Bd.V.30 Page Number 565. SSR I.No.41.74, Sr.No.1359 P.No.261
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195mm size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. as directed by Engineer in charge. SSR I.No.48.35, Sr.No.1626, P.No.301 (SSR 2020-21 GREEN BUILDING)
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Spec. No. : Bd.V. 38 Page No. 531. SSR I.No.42.02, Sr.No.1367 P.No.263
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying 100 mm dia salt glazed stoneware pipe including fittings such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete.Spec. No.:Bd.V. 39 Page No. 573. SSR I.No.42.03, Sr.No.1368,P.No.263
Ground Floor
Providing and laying for 150 mm dia salt glazed stoneware pipe including fittings Such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete.Spec. No. :Bd.V. 39 Page No. 573..SSR I.No.42.04, Sr.No.1369, P.No.263
Ground Floor
Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.Spec. No. :Bd.V.41, Page No. 573.SSR I.No.42.07, Sr.No.1372 P.No.263
Ground Floor
Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No. :Bd.V.41, Page No. 573.SSR I.No.42.09, Sr.No.1377 P.No.263
Ground Floor
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete.Spec. No. : Bd.V. 43 Page No. 574. SSR I.No.42.12, Sr.No.1377, P.No.264
Ground Floor
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete.Spec. No. :Bd.V.43, Page No. 574..SSR I.No.42.13, Sr.No.1378, P.No.264
Ground Floor
Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cm including 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with R.C.C. Cover medium duty 140 Kilogram. etc complete Spec. No. Bd.V. 44 Page No. 5745. SSR I.No.42.15, Sr.No.1380, P.No.264
Ground Floor
Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.Spec No.:As directed by Engineer in charge.. SSR I.No.42.20, Sr.No.1385, P.No.264
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete.Spec. No. : As directed by Engineer in charge. SSR I.No.42.31, Sr.No.1396, P.No.266
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing white glazed earthenware sink 600mm x 200mm x 450mm including all connection of the G.I. supply and P.V.C. waste pipes up to the outside face of the wall, cold water chromium plated screw down bib tap, rolled steel or C.I. brackets, rubber plug with chain and stop tap complete. Spec No.:As directed by Engineer in charge. SSR I.No.41.75, Sr.No.1360, P.No.262
Third Floor
Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.42.78, Sr.No.1443, P.No.271
Ground Floor
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.42.79, Sr.No.1444, P.No.271
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.42.82, Sr.No.1447, P.No.271
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.42.83, Sr.No.1448, P.No.271
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing C.P. sink cock with raised J" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete." Spec No.:As directed by Engineer in charge. SSR I.No.42.84, Sr.No.1449, P.No.271
Ground Floor
First Floor
Second Floor
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.42.36, Sr.No.1401, P.No.266
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirement etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.42.37, Sr.No.1402, P.No.266
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. Supply pipe including necessary bend and socket complete. Spec No.:As directed by Engineer in charge. SSR I.No.41.51, Sr.No.1339, P.No.259
Ground Floor
First Floor
Second Floor
Third Floor
Providing and Fixing half turn 25 mm dia gun metal flushing cock including all accessories etc. complete.Spec No.:As directed by Engineer in charge. SSR I.No.42.32, Sr.No.1397, P.No.266
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing Orissa Pan of size 580x445x260 mm with approved make flush valve including trap, C.I. soil and vent pipe upto outside face of wall including 100mm dia. C.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge. Spec No. As directed by Engineer in charge. SSR I.No.48.38, Sr.No.1629, P.No.301 (SSR 2019-20 GREEN BUILDING)
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing white european type wall-hung pan, of size 350mm x 355mm x 570 mm concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.48.41, Sr.No.1632, P.No.301 (SSR 2019-20 GREEN BUILDING)
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall. Spec No.:As directed by Engineer in charge. SSR I.No.41.60, Sr.No.1348, P.No.260
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete Spec. No.: As directed by Engineer in charge.SSR I.No.42.51, Sr.No.1416, P.No.268
Ground Floor
First Floor
Second Floor
Third Floor
Ground Floor
Ground Floor
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres Spec. No. As directed by Engineer in charge. SSR I.No.42.54, Sr.No.1419, P.No.268
Third Floor
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.55, Sr.No.1420, P.No.268
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.56, Sr.No.1421, P.No.268
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.57, Sr.No.1422, P.No.269
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.58, Sr.No.1423, P.No 269
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge .SSR I.No.42.59, Sr.No.1424, P.No.269
Ground Floor
First Floor
Second Floor
Third Floor
roviding and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge .SSR I.No.42.60, Sr.No.1425, P.No.269
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating, bend, connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) Spec. No. BD.V 32 A page 551 and as directed by Engineer in charge. SSR I.No.43.18, Sr.No.1471 P.No.275
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Spec No. As directed by Engineer Incharge. SSR I.No.42.85, Sr.No.1450, P.No.272
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying in walls/ceilings/floors 15 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 1.25 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No. Bd.V.5 Page No. 551..SSR I.No.43.01, Sr.No.1454, P.No.273
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying in walls/ceilings/floors 20 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 1.63 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No. Bd.V.5 Page No. 551..SSR I.No.43.02, Sr.No.1455, P.No.273
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying in walls/ceilings/floors 25 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 2.49 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No. Bd.V.5 Page No. 551. SSR I.No.43.03, Sr.No.1456, P.No.273
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying in walls/ceilings/floors 32 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 3.20 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No. Bd.V.5 Page No.551. SSR I.No.43.04, Sr.No.1457, P.No.273
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying in trenches 15 mm dia.heavy grade having embossed as ISI Mark galvanised iron pipes of 1.48 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No. :Bd. V. 5 Page No. 551..SSR I.No.43.09, Sr.No.1462, P.No.274
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying in trenches 20 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 1.93 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No. :Bd. V. 5 Page No.551. SSR I.No.43.10, Sr.No.1463, P.No.274
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying in trenches 25 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 3.01 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No. :Bd. V. 5 Page No. 551..SSR I.No.43.11, Sr.No.1464, P.No.274
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying in trenches 32 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 3.89 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No. :Bd. V. 5 Page No. 551..SSR I.No.43.12, Sr.No.1465, P.No.274
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying in trenches 15 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.61, Sr.No.1426, P.No.269
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying in trenches 20 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.62, Sr.No.1427, P.No.269
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying in trenches 25 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.63, Sr.No.1428, P.No.269
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying in trenches 32 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.64, Sr.No.1429, P.No.269
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying in trenches 40mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.65, Sr.No.1430, P.No.270
Ground Floor
First Floor
Second Floor
Third Floor
Providing and laying in trenches 50mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.66, Sr.No.1431, P.No.270
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete Spec No.:As directed by Engineer in charge. SSR I.No.43.25, Sr.No.1478, P.No.276
Ground Floor
First Floor
Second Floor
Third Floor
Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providingT.W.gutties etc. complete Spec. No.: As directed by Engineer in charge .SSR I.No.43.26, Sr.No.1479, P.No.277
Ground Floor
First Floor
Second Floor
Third Floor
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.Spec. No. As directed by Engineer in Charge. SSR I.No.21.22, Sr.No.730, P.No.150
Ground Floor
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper. Spec. No. As directed by Engineer in harge. SSR I.No.21.23, Sr.No.731 P.No.150
Ground Floor
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. Spec. No. As directed by Engineer in harge. SSR I.No.21.24, Sr.No.732 P.No.150
Ground Floor
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper. Spec. No. As directed by Engineer in harge. SSR I.No.21.25, Sr.No.733 P.No.151
Ground Floor
Providing and fixing 90 cm x 60 cm Granite plate engraving 10 cm. height letter, figures including painting the lefters/figures with approved colour and shade complete Spec. No. Bd.W.7 Page No.586. SSR I.No.44.12, Sr.No.1507, P.No.281
Ground Floor
Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate) Spec. No. As directed by Engineer in charge. SSR I.No.51.235, Sr.No.2035, P.No.403
First Floor
Second Floor
Third Floor
Providing and fixing in position U.P.V.C.(Unplasticized Poly Vinyl Chloride) having multichambered outer frame section (73 x 50)mm with an outer wall thickness of 2mm & steel reinforcement, multi-chambered slider frame (73x 60) mm with steel reinforcement, multichambered slider sash (46x 82) mm with steel reinforcement designed to give optimum strength, 5 mm thick toughened double glass with 12 mm spacer of good quality including alluminium track, Inter-locking profile, coextruded beadings, EPDM gaskets,silicon sealent,sliding handle, fixtures and fastenings (couplings, hinges) including with all required screws and nuts with all necessary U.P.V.C. sections as per the detailed drawing and as directed by Engineer-In-Charge etc. complete. Spec. No. As directed by Engineer in charge. SSR I.No.48.22, Sr.No.1633, P.No.299
First Floor
Second Floor
Third Floor
Supplying, drilling/cleaning hole and fixing of HILTI Torque Controlled Expansion Anchor HST3, of sizes ranging from M8 to M24. The Anchor should be third party tested, possess ETA approval and should be pre-assembled with a galvanized bolt as per EN ISO 4042: 1999, ingenious expansion sleeve M10 and M16 (galvanized) and M8, M12, M20, M24 Stainless Steel (EN ISO 4042: 1999), a nut of Strength Class 8 (EN ISO 20898-2:2012) and a galvanized washer (EN ISO 4042:1999). The anchor should be approved for use in Cracked Concrete. Anchor must be tested and approved as per Seismic C1 and C2 Category of TR045. ETA to have Fire Resistance values for up to 120 mins as per EOTA TR 020 and FM Approval (use in Pipe Hangers). Anchor shall be fixed at right embedment depth as per embedment mark and activated using Hilti AT Tool Module to ensure adequate torque as per manufacture’s torque tolerance published in ETA and same shall be documented and submitted to Project Manager at the time of inspection. Design of Anchor should be done as per ETAG 001 Annex C and TR045 using PROFIS Software as per actual load data and site conditions as provided by structural consultant and the report to be submitted to the project manager and design engineer for approval. Scanning before drilling to be done with Hilti PS Scanning tool to avoid rebar hits. stud anchor HST3 SS M24x200 30 Spec. No. Bd.C.2 Page No. 275. SSR I.No.53.35, Sr.No.3135, P.No.450
Third Floor
Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. Spec. No. Bd.V.46, Page Number 576. SSR I.No.42.19, Sr.No.1384, P.No.264
Ground Floor
RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge. Spec. No. Bd.V.46, Page Number 576. SSR I.No.48.46, Sr.No.1637, P.No.302
Ground Floor
Boring/drilling bore well of 300mm dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level. SSR I.No.48.48, Sr.No.1639, P.Bo.266
Ground Floor
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well-casing pipe of 150mm dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer in charge. SSR I.No.48.49, Sr.No.1640, P.Bo.266
Ground Floor
Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mm Outlet pipe size rigid PVC:-80mm Gas outlet rigid PVC with Valve: 20mm Bacteria immobilization PVC mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below. Spec. No. BDW. SSR I.No.51.112, Sr.No.1923, P.No.370 c) Up to 25 user size (1.5mx1.0mx1.0m), Capacity of biodgester:-1500 liters, Area of top, bottom and side walls:- 8 sq.m, Area of partition walls: 2 sq.m, Total weight of frp: - 82.80 Kilogram, Bacteria inoculums quantity: - 600 liters, Minimum thickness of side walls / top and bottom: 5mm, Number of inside partitions: - 3, Minimum thickness of partition wall: 3mm Spec. No. As directed by Engineer in Charge. SSR I.No.51.112, Sr.No.1926, P.No.370
Ground Floor
Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mm Outlet pipe size rigid PVC:-80mm Gas outlet rigid PVC with Valve: 20mm Bacteria immobilization PVC mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below. Spec. No. BDW. SSR I.No.51.112, Sr.No.1923, P.No.370 d) Up to 40 user size (2.0mx1.0mx1.0m), Capacity of biodgester:-2000 liters, Area of top, bottom and side walls: - 10 sq.m, Area of partition walls: 3 sq.m, Total weight of frp: - 106.20 Kilogram, Bacteria inoculums quantity: - 600 liters, Minimum thickness of side walls / top and bottom: 5mm, Number of inside partitions: - 3, Minimum thickness of partition wall: 3mm Spec. No. As directed by Engineer in Charge. SSR I.No.51.112, Sr.No.1927, P.No.370
Ground Floor
Ground Floor
3) FURNITURE WORK
Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work) SSR I.No.51.19 Sr.No.1824 page No.344
Ground Floor
First Floor
Second Floor
Third Floor
Pedestal Unit @ 420Lx450Dx650HT Providing & Fixing of PEDESTAL @ 420Lx450Dx650HT :- To be made out of Complete Membrane consist of three Drawers as per drawing.. As directed by Engineer-incharge SSR I.No.51.22 Sr.No.1827 page No.344
Ground Floor
First Floor
Second Floor
Third Floor
Credestal @ 1200Lx450Lx650HT Providing & Fixing of LOW HEIGHT CREDESTAL @ 1200L X 450D X 650H :- To be made out of Membrane Finish ( 2 Openable Shutter & 3 Drawer Pedestal in between )as per drawing. As directed by Engineer-incharge SSR I.No.51.23 Sr.No.1828 page No.344
Ground Floor
First Floor
Second Floor
Third Floor
3 DRAWER PEDESTAL UNIT @ 392L x 450D x 680Ht. mm. 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board. As directed by Engineer-incharge SSR I.No.51.34 Sr.No.1839 page No.348
Ground Floor
First Floor
Second Floor
Third Floor
Low Height Openable Storage @ 900Lx450x750HT Providing and fixing Openable Steel Storage of 900 x 450 x 750Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns. with 25 mm. thk additional Top on top of storage as as per drawing As directed by Engineer-incharge SSR I.No.51.35 Sr.No.1840 page No.348
Ground Floor
First Floor
Second Floor
Third Floor
Executive Table @ 2250Lx2100Dx750HT including Low Height Credestal @ 1200Lx450Dx650HT Providing & Fixing of Table @ 2250Lx2100Dx750HT TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band. INCLUDING CREDESTAL @ 1200L X 450D X 650H :- To be made out of Membrane Finish ( 2 Openable Shutter & 3 Drawer Pedestal in between ) as per drawing. SSR I.No.51.24 Sr.No.1829 Page No.345
Ground Floor
First Floor
Second Floor
Third Floor
Conference Table @ 3600Lx1400Dx750HT Providing & Fixing of Main Table @ 3600Lx1400Dx750HT - made up of 18+18mm Thick MDF top with PVC Membrane finish and waterfall edge profile. Aluminium Anodizied finish beeding of 4mm thich is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in PVC Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from inside for the provision of passing electrical and Data wiring. , MODESTY PANEL:- to be made of 18 mm thick Prelaminated particle board with PVC edge band Access Flap:- For Wire manager 2 Nos. SSR I.No.51.31 Sr.No.1836 Page No.347
Ground Floor
First Floor
Second Floor
Third Floor
Book Case with Glass Shutter@ 825Lx300Dx1650HT Providing & Fixing of Book Case with Glass Shutter @ 825Lx300Dx1650HT:- To be made out of complete body & in 0.7mm thick CRCA & Shutter in 1.2mm thick CRCA with glass pannel in Powder coating finish as per drawing. SSR I.No.51.39 Sr.No.1844 Page No.349
Ground Floor
First Floor
Second Floor
Third Floor
Providing & Arrangemnt of High Back, Synchronized Mechanism with Multiple Locking, Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery SSR.I.No.51.40 Sr.No.1845 Page No.349
Ground Floor
First Floor
Second Floor
Third Floor
Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. SSR I.No.51.41 Sr.No.1846 Page No.349
Ground Floor
First Floor
Second Floor
Third Floor
Providing & Arrangemnt of MId Back, Normal Syncro Mechanism,Fixed Armrest , Gaslift for Seat height adjustment, Standard 5prong/Nylon Base with Leather Upholstery SSR I.No.51.42 Sr.No.1847 Page No.349
Ground Floor
First Floor
Second Floor
Third Floor
Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. SSR I.No.51.44 Sr.No.1849 Page No 349
Ground Floor
First Floor
Second Floor
Third Floor
Alluminium foldable ladder for store Providing & Fixing Foldable Alluminum Ladder 1500 mm. Ht. SSR I.No.51.52 Sr.No.1863 Page No.355
Ground Floor
First Floor
Second Floor
Third Floor
Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (cms) Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (kgs): 66 (Kg) Seating Capacity: Five Seat SSR I.No.51.53 Sr.No 1864 Page No.355
Ground Floor
First Floor
Secon Floor
Third Floor
Free Standing Table @ 1200Lx600Dx750HT Providing and fixing Table of Size 1200 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, SSR.INo.51.28 Sr.No.1833 page No.346
Ground Floor
First Floor
Second Floor
Third Floor
12 Seater Reading Table for Library @ 3600Lx1200Dx750HT Providing and Fixing 12 Seater Reading Table for Liberary @ 3600Lx1200Dx750HT Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Gable Ends : made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine. SSR.INo.51.33 Sr.No.1838 page No.348
Second Floor
Tea Table 900mm X 750mm X 450mm for m.s. ante chamber Providing And Fixing Of Tea Table 900mm X 750mm X 450mm With 12mm Thick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18mm Thick Waterproofing Ply. The Outer Laces To Be Finished With High Quality 4 Mm Thik Veneer Or 1 Mm Thik Mica Etc. SSR.INo.51.54 Sr.No.1865 page No.355
Ground Floor
First Floor
Second Floor
Third Floor
Providing & Fixing in position, 12mm wp Ply wood & 1.5mm laminate panels above the fabricated frame on one side , as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour,finishing etc complete.As directed by Engineer-incharge SSR I.No.51.15 Sr.No.1820 Page No.343
Ground Floor
First Floor
Second Floor
Third Floor
ELECTRIFICATION , LIFT & FIRE FIGHTING
EXTERNAL ELECTRICAL WORK
Supplying , erecting & terminating 3 x 95 sq. mm. aluminium 11 kV(UE), XLPE armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification no. CBHT
Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable upto 95 sq. mm. with necessary material as per specification no. CB-JT/HT
Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable upto 95 sq. mm. with necessary material as per specification no. CB-JT/HT
Supplying & laying (including excavation)25 cm dia RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for covering provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).
Supplying & erecting cast iron cable indicator plate buried along with route of cable for PVC / XLPE armoured cable as per specification No. CB-CIP
Supplying, erecting, testing, commissioning 11 KV HT metering cubical (compact type) approved by MSEDCL/licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle and channel, painted with powder coating / epoxy paint of required shade copper bus bar size 25x6 mm electronic security lock and heavyduty mechanical lock, with counter meter for measuring no of times the opening of doors, top side cover (CT,PT cover) interlock with meter doors, epoxy coated 3 nos CT having required ratio between 75/5 A to 100/5 A, VA10,class0.2S, 11000/V3/110/V3 VA 50, class 0.2 epoxy terminal block suitable for provided trivector meter, and provision for incoming and outgoing cables etc. complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation
Supplying and erecting extendable / non-extendable outdoor type 11 kV 630A, load break isolator switch with fuses of required rating on provided MS channels / trench / foundation as per specification no SW-HTS / LBS
Providing Cement concrete foundation for pump in 1:2:4 with required size and length of foundation bolts and nuts (cost with wooden box is included). (Here plinth for Metering Cubical, LBS and DG set)
Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 315 kVA, oil immersed and naturally cooled outdoor type, copper wound transformer, delta /star connected additional neutral brought out on load side, temperature rise should not exceed 40 o C by thermometer in oil and 45 C by the resistance in winding at full load rating, with HV tapping (with off load tap changer) off load + 5 to -10 in steps of 2.5%, with standard accessories complete with test certificate with losses below 1860 Watts at 50% load, 5300 Watts at 100% load as per IS:1180 - 2014 energy efficiency level II with necessary permissions of Electrical Inspector, as per specification no SS- TR
Providing transformer plinth 1.5 x 1.5 x 1.5 m in size with necessary excavation in ground at the bottom with 150 mm. thick M-10 PCC at the bottom and top and 250 mm. thick burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 60mm Hard broken aggregate, external surface duly plastered 15 mm thick including watering etc. complete.
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in C C foundation and painted as per specification No SS-AS/FSG
Supplying and erecting 50 x 50 x 6 mm. angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in C.C. foundation of 15 x 15 x 40cm complete duly painted with one coat of red oxide and two coats aluminum paint.
Supplying and erecting double leaf hinged door each 1500mm in width x 1850 mm in height using B class ,GI pipe with angle iron supports, chain link wiremesh (jali) complete supported on channel iron, erected in foundation, and painted as per specification no SS-AS/DLD
Providing and spreding stone metal 25 mm size for 100mm depth above the ground level
Providing earthing with Galvanised cast iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials,testing & recording the results as per specification No. EA-EP ( Metering Unit - 9 Nos, Transformer Body & Neutral - 4 Nos, LBS - 2 Nos)
Supplying and erecting G.I. strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joint required. as per specification No (EA-EP).
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification No EA-EP.
Providing round bottom fire bucket of 9 liters capacirty as per IS :2546 made out of 24SWG GI sheet with extra handle at bottom duly painted white inside and red outside with FIRE mark on provided stand wall hook
provoding floor mounting stand for keeping 4 nos of FIRE buckets 1500mm in length,900mm in height frame made out of 30x30x4mm angle iron with cross supports for legs,welded with 4 hooks & duly painted with red lead & 2 coats of silver paint
Supplying and fixing PVC Synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 & CPRI tested having 2.5 mm thickness upto 11 kV
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. Capacity Cartridge type conf. To IS 2878 Complete erected with necessary clamp made front 50x6 mm. M. S. flat with nut & bolts grouted in wall complete
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated.
Providing pair of duly tested rubber handgloves as per IS 340715 suitable for working on 22KV supply
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal use, scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes)
Supplying, erecting and commissioning of diesel generating setwith alternator of 320 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standardaccessories, self excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722- 2001 with voltage regulation +/- 5 %. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising of meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level upto 75 dB at 1.0 m, provided with first filling of oil, diesel etc. and obtaining necessary approval from Electrical Inspector as per specification no. GENDG
Providing earthing with Galvanised cast iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials,testing & recording the results as per specification No. EA-EP ( DG set Body & Neutral - 2 Nos each)
Supplying and erecting G.I. strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joint required. as per specification No (EA-EP).
Supplying, erecting, testing and commissioning of Microprocessor based AMF panel suitable for diesel generating set of above 320 kVA upto 400 kVA capacity Single/Three phase, 230/415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
Providing & erecting 8 m high (clear height) galvanised OCTAGONAL pole with foundation bolts having bottom of 135 mm A/F, top 70 mm A/F on provided foundation as per specification No.OH-PL/OPL
Providing and erecting Galvanised 1000mm double arm sword type bracket with FRP dome and Ball as per specification No. OH-PL/PBKT
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
Supplying & erecting pipe type earthing with 40mm.dia.Gl.pipe or 20mm dia.Gl.Rod complete with all materials as per specification no. EA-EP
Supplying & erecting G.I.Earth wire of high purity of different sizes used for earthing or any other purposes on wall with G.I.necessary clamps as fixed on wall/cable/conduit with screws in an approved manner
Providingcement concrete for foundation or for concrete filling in 1:3:6 ratio with 20 to 25 mm. stone metal duly plastered with necessary curing for pole muffing or any other purposes.
Supplying and erecting triple pole and neutral distribution board (TPNDB) with doorsurface/flush mounted SP MCB’s of 12 WAYS on iron/ G.I. frame/wooden board as per horizontal busbar typespecification No. SWSWR/MCBDB
Supplying, erecting & markingFPMCB 6A to 32A in provided distribution board as per specification No. SW-SWR/MCB
Supplying & erecting & marking SPMCB 6A to 32A B series ( for light) in provided distribution board . As per specification no. SW-SWR/MCB ( In DB - 12 Nos..)
Supplying & erecting & marking SPMCB 0.5A to 5A B series ( for light) in provided distribution board . As per specification no. SW-SWR/MCB
Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (From LT Panel to Street Lighting Panel)
Supplying, erecting & terminating XLPE armoured cable 4 core 4 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL ( From Street Lighting Panel to Poles)
Supplying and erecting LED street light fitting suitable for above75W - 90W lamp, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No. FGODF/FLS2
Supplying & laying(including excavation) 25 cms. dia RCC hume pipe with coupling collar of standard thickness at required depth upto 90cms. below road/ground surface, for enclosing provided cable and necesary back filling with light ramming to make the road/ground surface as it was.(Except bitumen carpet).
Making the trench in hard murum/Tar road of suitable width and depth as per IS for laying provided LT cable of 25 sqmm & above and covered with half round hume pipe complete as per specification no. CW-EXN-CTR
Supplying and erecting gate/garden light fitting with 300mm dia.glass bowl suitable for upto 12W LED Lamp on provided pipe as per specification No. FG-ODF/GLT
Providing & erecting 3 m high (clear height) galvanised OCTAGONAL pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification No. OH-PL/OPL
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design complete (for 3 to 5m octagonal / conical GI pole).
Supplying & erecting integral post top lantern fixtures (light house type)suitable upto LED 18 W Lamp consisting of combination of spun aluminium canopy & clear acrylic top cover, cast aluminium pole cap on provided pole/ bracket as per specification no. FG-ODF/PTL (NEW)
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP ( Building - 8 No, MCBDBS - 8 No(2 for each floor), Lightning Arrestor - 4 NoLift-2 per lift.)
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA ( For Machines - 2 Nos., UPS - 2 Nos( for UPS)
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in anapproved manner with joints required. as per specification No(EA-EP).
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification No EA-EP ( For Panel, DBs, Building Earthing etc.)
Supplying & erecting G.I.Earth wire of high purity of different sizes used for earthing or any other purposes on wall with G.I.necessary clamps as fixed on wall/cable/conduit with screws in an approved manner ( From DBs to Earth bus and other small electrical appliances etc)
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos.copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation in an approved manner
Supplying & erecting Centrifugal Water Pump (Monoblock), 415 V, Three Phase 50 Cycles A.C. Supply of 3.75 KW/ 5 HP with discharge 2/4.1 Liters per second (LPS) for head of 36/52 m and 50 mm suction/ 40 mm delivery pipe on provided C.C. foundation as per specification No. WP-CG
Supplying & erecting mains with 4x10 Sq.mm.and Earth Wire 6 Sq.mm FR PVC Copper Wire, in HMS rigid PVC conduit 32mm dia, as per specification No: WG-MA/PC, para no. 1.4.1
Supplying and erecting D.O.L. Starter 400V. 3 Phase, 50 Cycles with no volt coil and overload element with necessary materials and connected to supply Upto 7.5 H.P. (Similar to L & T make MK-1 DOL Model)
INTERNAL ELECTRIFICATION
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A upto 630A MCCB complete.
Supplying and erecting terminal spreaders for use on MCCB incoming and outgoing terminals for 4 pole above 400A upto 630A MCCB complete. (Set of 8)
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 630A complete as per specification no. CP-BB
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying & erecting LED type indicating pilot lamp with LED colours Red / Yellow / Green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colours Blue, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Providing & erecting LT currect transformer with bar primary 50/5 to 1000/5 Ratio with 15 VA burden erected in provided crsa box duly secured with insulating material connected to the meter with test certificate.
Supplying and erecting H.C. pattern porcelain fuse bridges with base & HC type fuse links 250V 16A approved make erected on polished wooden block.
Supplying & erecting fuse bridges with base H.C. type fuse links 250/500V 63A erected on polished wooden block. .
Supplying and erecting Iron, sheet metal work consisting of CRCA Sheets, Various sections of iron, Plates, Chequered Plates, Rods, Bars, MS pipes, etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority (Panel Foundation)
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A upto 630A MCCB complete.
Supplying and erecting terminal spreaders for use on MCCB incoming and outgoing terminals for 4 pole above 400A upto 630A MCCB complete. (Set of 8)
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 630A complete as per specification no. CP-BB
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying & erecting LED type indicating pilot lamp with LED colours Red / Yellow / Green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colours Blue, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Providing & erecting LT currect transformer with bar primary 50/5 to 1000/5 Ratio with 15 VA burden erected in provided crsa box duly secured with insulating material connected to the meter with test certificate.
Supplying and erecting H.C. pattern porcelain fuse bridges with base & HC type fuse links 250V 16A approved make erected on polished wooden block.
Supplying & erecting fuse bridges with base H.C. type fuse links 250/500V 63A erected on polished wooden block. .
Supplying and erecting Iron, sheet metal work consisting of CRCA Sheets, Various sections of iron, Plates, Chequered Plates, Rods, Bars, MS pipes, etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority (Panel Foundation)
Providing & erecting 3 Pole MCCB of 315/400 A, 415V capacity with short circuit rating 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB(for APFC)
Providing & erecting 4 Pole MCCB of 600/630 A, 415V capacity with short circuit rating 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB(reqd 500A)
Providing & erecting 4 Pole MCCB of 315/400A, 415V capacity with short circuit rating 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB of 200A, 415V capacity with short circuit rating 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB of 250A, 415V capacity with short circuit rating 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB upto 100A, 415V capacity with S.C. rating 25 kA (Ics=100% of Icu), thermal setting with provided leads on iron frame/wooden board as per specification No. SW-SWR/MCCB
Supplying and erecting150 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP / APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification no CP-ED/APFC
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted for 3 pole MCCB as incomer SP (24 poles) / TP MCBs8 ways (24 poles) on iron/ GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB(4 -GF/FF/SF/TF FLOOR PANELS. 1-UPS DB)
Providing & erecting 4 Pole MCCB of 250A, 415V capacity with short circuit rating 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB (FOR FLOOR PANELS,(FOR UPS DB)
Providing & erecting 4 Pole MCCB of 200A, 415V capacity with short circuit rating 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB (FOR FLOOR PANELS,(FOR UPS DB)
Supplying, erecting & marking TPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB(FOR VRF ODU)
Supplying and erecting triple pole and neutral distribution board (TPNDB) with doorsurface/flush mounted SP MCB’s of 24 WAYS on iron/ G.I. frame/wooden board as per horizontal busbar typespecification No. SWSWR/MCBDB(2 UPS+2 RAW+2 LTG=10/FLOOR,1 UTILITY)
Supplying, fixing and commissioning 4 pole RCBO ( (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 32/40A as per specification no SW-RCCB/RCBO
Supplying, fixing and commissioning 4 pole RCBO ( (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 63A as per specification no SW-RCCB/RCBO
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification No. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification No. SW-SWR/MCB For use of 4pole MCCB in place of 3pole MCCB add 20% in overall rate of 3 pole MCCB. ( 20% Added in 3 pole MCCB rates)
Supplying, erecting & terminating XLPE armoured cable 3½ core 185 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (transformer 2R each of 70M & D.G2R each of 40M )
Supplying, erecting & terminating XLPE armoured cable 3½ core 95 sq. mm. aluminium conductor with continuous 8.35sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 70 sq. mm. aluminium conductor with continuous 8.35sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU (15 M PER DB FM FLOOR PANEL)
Providing & erecting Hot dipped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 500 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Supplying & laying HMS PVC conduit 25 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No.WG-MA/CC
Point wiring for light/fan/bell points consealed type in min 20mm PVC conduit with 1.5 sqmm FRLS grade copper wires with modular type switch and required accesssories as per specification no. WG-PW/SW
Supplying & erecting modular type electronic dimmer 1000W 2 module ISI marked approved make duly erected on provided plate & box with wiring connections complete
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner.
Point wiring for two way light points consealed type in min 20mm PVC conduit with 1.5 sqmm FRLS grade copper wires with modular type switch and required accesssories as per specification no. WG-PW/SW
Wiring for plug on board with Switch socket concealed type and copper wiring, earthing and with modular accessories as per specification No: WG-PW/CW
Point wiring for independent plug, concealed type in min 20mm PVC conduit with 1.5 sq.mm FRLSgrade copper wires with moduler type switch and socket and required accessaries as per specification No WG-PW/SW (20 added for lift)
Supplying & Erecting modular type 3 pin 6/16A multi socket with safety shutters combined unit ISI marked approved make duly erected on provided plate & box with wiring connections complete ( for AC44)
Supplying and erecting modular type switch 16A ISI mark approved make duly erected on provided plate and box with wiring connections complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner.
Supplying and fixing tool-less Information Outlet (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner. ( For 20A S/S Outlet)
Supplying & erecting mains with 2x2.5 sq.mm.and earth wire 1.5 sq.mm FRLS PVC copper wire, in rigid PVC conduit min.20mm dia, as per specification No: WG-MA/PC, para no. 1.4.1 (Lighting Mains Consealed Type)
Supplying & erecting mains with 2x4 sq.mm.and earth wire 2.5 sq.mm FRLS PVC copper wire in rigid PVC conduit min.20mm dia,as per specification No: WG-MA/PC, para no. 1.4.1 (Raw Power3550,UPS2350,AC1100)
Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22/E-27 base.
Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting LED square / circular 13 to 15W down lighter having pressure die-cast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting LED square / circular 16 to 20W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying & erecting corridor/passage light fitting (2feet)including LED9W tube comprises of extruded channel in plastic silver grey colour and with same plastic end cap on provided pvc block/wooden board
Supplying & erecting LED 18W tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated HF electronic driver complete.
Supplying and erecting square shaped CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) 600x600mm suitable for 36 W-40W with provision for plane front frame with translucent cover fixed to the housing complete
Supplying and erecting ding dong/ electronic musical type call bell with heavy duty coil suitable to operate on 230V AC supply erected on polished double wooden block /sunmica block of suitable size
Supplying and erecting five star rated energy saving Ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.
Supplying and erecting split type variable speed Inverter technology room Air conditioning unit 1 TR 5 capacity having ISEER minimum 4.5,suitable to operate on 250V, 50 cycles, A.C. supply having 1 No of air handling unit hi-wall mounting type complete with Refrigerants R410 A /R32 and COPPER CONDENSOR at position as per specification no. AP-AC/SAC
Supplying and erecting split type variable speed Inverter technology room Air conditioning unit 1.5 TR 5 capacity having ISEER minimum 4.5,suitable to operate on 250V, 50 cycles, A.C. supply having 1 No of air handling unit hi-wall mounting type complete with Refrigerants R410 A /R32 and COPPER CONDENSOR at position as per specification no. AP-AC/SAC
Supplying and erecting split type variable speed Inverter technology room Air conditioning unit 2 TR 5 capacity having ISEER minimum 4.5,suitable to operate on 250V, 50 cycles, A.C. supply having 1 No of air handling unit hi-wall mounting type complete with Refrigerants R410 A /R32 and COPPER CONDENSOR at position as per specification no. AP-AC/SAC
Supplying and erecting split type variable speed Inverter technology room Air conditioning unit 2.5 TR 5 capacity having ISEER minimum 4.5,suitable to operate on 250V, 50 cycles, A.C. supply having 1 No of air handling unit hi-wall mounting type complete with Refrigerants R410 A /R32 and COPPER CONDENSOR at position as per specification no. AP-AC/SAC
Supplying, installing caaxial copper cable low voltage grade RG-6 as per specification No. WG-TW
Supplying and fixing Rack mounted type 12 Ports, Light guide unloaded Interconnect Unit with adapter Panel for termination of Optical fibre cables on wall/ provided U Rack complete as per specification no. WG-NAS/ LIU(Supplying and erecting GIGA LAN Switch Make Cisco 8 port)
Supplying and fixing Rack mounted type 12 Ports, Light guide unloaded Interconnect Unit with adapter Panel for termination of Optical fibre cables on wall/ provided U Rack complete as per specification no. WG-NAS/ LIU(Supplying and erecting GIGA LAN Switch Make Cisco 24 port-13 required))
Supplying and erecting 12U wall mount Rack for LAN switches
Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 24 extensions suitable upto 96 extensions complete. Add 72 Extention We Need A Cord of 16 Extention 8 4 Cord of 8 ExtentionRate of 16 Cord = 31576 X 4 = 126304 - Rate of 4 Cord = 17089 X 1 = 17089 - Total rate = 197124.00
Supplying, erecting & commissioning MDF box 300x300as per specification No. WG-TW
Supplying, erecting & commissioning MDF box 60x60as per specification No. WG-TW
Supplying, erecting & commissioning Junction box suitable for 10 pairs as per specification No. WG-TW
Supplying, erecting & commissioning Junction box suitable for 20 pairs as per specification No. WG-TW
Supplying, installing, testing & commissioning approved type Push button telephone instrument desk top/wall mount unit as per specification in approved manner
Supplying, fixing, and configuring 8-ports 10/100/1000Mbps Unmanaged Gigabit PoE Switch
Supplying, Installing, HDMI cable low voltage grade as per specifications having 5 m,tr cord length with male/female 19 pin HDMI connectorsas per requirement complete
Supplying, Installing, VGA cable to be laid in provided conduits and terminating as per specifications having 15 mtr cord length with male/female VGAconnectorsas per requirement complete
Supplying & installing UTP networking Cat-6 cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC
Supplying & installing FR grade pvc armourerd multimodeoptical fibre cable with 6 fibres with core dia 50/125 microm(OM3) suitable for 1gbps ethernet distance at 850nm wavelength on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/NC
Supplying & erecting telephone cable 2 pair with 0.5 mm dia. laid in provided PVC casing / conduit as per specification No. WG-TW
Supplying & erecting telephone cable 5 pair with 0.5 mm dia. laid in provided PVC casing / conduit as per specification No. WG-TW
Supplying & erecting telephone cable 20 pair with 0.5 mm dia. laid in provided PVC casing / conduit as per specification No. WG-TW
Supplying & erecting telephone cable 20 pair with 0.5 mm dia. laid in provided PVC casing / conduit as per specification No. WG-TW
Supplying & erecting telephone cable 50 pair with 0.5 mm dia. laid in provided PVC casing / conduit as per specification No. WG-TW
Supplying & erecting telephone cable 100 pair with 0.5 mm dia. laid in provided PVC casing / conduit as per specification No. WG-TW
Supplying, erecting, testing and commissioning amplifier 120 W for Public address system suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply as per specification No. FF-PA/AFR(seminar,VC ROOM)
Supplying, erecting, testing and commissioning microphone as per specification No. FF-PA/MIC
Supplying & erecting, Table stand for microphone. Complete
Supplying erecting, testing to 2 core shielded Microphone cable as per specification No. FF-PA/MCC
Supplying erecting, testing and commissioning of 1.5 speaker wire complete
Supplying ,erecting ,testing and commissioning sound columnn 15 W complete as per specification no FF PA/SOC
Supplying and erecting on line UPS pure sine wave of 10 KVA capacity complete with standard features along with necessary SMF batteries for 30 mins backup as per COUNSOULL NEOWATT
SITC of Electric Traction Passenger Lift with• Rated capacity :- 4 Passenger/272Kg• Floors :- G+1 floor (2Stops/2 Landings)• Travel :- 3 to 4.2 mtrs• Location of Lift Machine:- MR/MRL• Rated speed :- 1.0mps VS• Doors type :- COPO/TOPO Doors with frame having clear opening of 800 mm wide x 2000mm high made from SS 304 grade sheet of 1.5mm, thick in hairline finish for car and all landing doors with SS door architraves/frames• Lift car enclosure made from SS 304 grade sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc.• COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with/without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor• Clear Car size of 1100mm wide x 1140mm deep x 2000mm high • LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings • Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor / control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powdercoating with IP54 Protection class• ARD complete with necessary SMF VRLA batteries• Fireman controller having fireman switch at fire Landing,• CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 60 days with 18" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.• Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG,
electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength• Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessarysteel work• Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT.• Lift shaft available having clear size of 1800mm wide x 2700mm deep, 2000mm Pit depth, 1800mm overhead.General :- Job Inclueds Entire Procedure of Obtaining all necessary creation permissions & "License to work the lift from electrical inspectors (Lifts) with submission to the engineer in charge.Warranty :- Job covers three years on site warranty for all the lift parts with FCAMC as per the Maintenance schedule
For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrowsindicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete( 2 FLOORS PER LIFT)
For Lift travelling above First floor & up to Sixth floor For use of 4pole MCCB in place of 3pole MCCB add 20% in overall rate of 3 pole MCCB. ( 20% Added in 3 pole MCCB rates)
Supplying, erecting CRCA sheeet metal one way enclosures suitable forDP MCB/TP MCB/FP MCB erected on angle iron /GI frame complete (FOR UPS I/C,O/G,8 for lift))
Supplying, fixing and commissioning 4 pole RCBO ( (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 32/40A as per specification no SW-RCCB/RCBO
Supplying, fixing and commissioning 2 pole RCBO ( (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 6/10/16/20/25A as per specification no SW-RCCB/RCBO
Supplying, erecting & terminating XPLE armoured cable 4 core 10 sq. mm. COPPER conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU(LIFT)
Supplying, erecting & terminating XPLE armoured cable2 core 4 sq. mm. COPPER conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU (LIFT)
Supplying, erecting annealed bare. COPPER wire with of high purity of different sizes used for earthing on wall with necessary copper clamps, fixed on wall/ trusses/pole with screws in an approved
Point wiring for light/fan/bell points consealed type in min 20mm PVC conduit with 1.5 sqmm FRLS grade copper wires with modular type switch and required accesssories as per specification no. WG-PW/SW
Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22/E-27 base. (20 for lift)
Supplying and bulkhead fitting suitable for upto12W LED fixed on wall as per specificationFG-IDF/BHF(FOR LIFT)
FIRE FIGHTING & ALARM
13-1-3 Supplying, installing, testing and commissioning with perfect aligning, proper levelling of fire service main single stage pump, of 2400 LPM at 76 m head centrifugal type, 75 HP (55 kW) 3 phase, 415 volt, 50Hz or of suitable HP complete as per specification no. FF-MFP/SSC ( Item No 13-1-3)
13-3-2 Supplying, installing, testing and commissioning with perfect aligning, proper levelling of jockey pump of 240 LPM at 105 m head 20 HP (15 kW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/JP
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of booster pump of 900 LPM at 40 m Head, 12.5 HP (10 KW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/BP ( Item No 13-4-4)
Supplying and installing air vessel of 300 mm dia 1.5m in height M.S. tank installed inside pump house / on terrace complete as per specification no. FF-FFA/ACT item no. 13.7.12
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 100 mm dia with necessary fittings complete as per specification no. FFPP item no. 13.5.6
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 75/80 mm dia with necessary fittings complete as per specification no. FF-PP item no. 13.5.5
Supplying and erecting cast iron double flange NRV of size 100 mm dia complete as per specification no. FF-VL/NRV item no. 13.6.20
Supplying & erecting cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. FF-VL/BFV item no. 13.6.16
Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FFFFA/PG item no. 13.7.14
Supplying and installing pressure switch with 12/15 mm diaisolation valve, G.I. nipple, elbow, etc complete as perspecification no. FF-FFA/PS item no 13-7-15
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV item no. 13.7.13
Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV item no. 13.6.30
Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL item no. 13.7.4
Supplying & erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ item no. 13.7.8
Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) fitted with necessary accessories complete as per specification no. FF-FFA/HV item no. 13.7.2
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour. item no. 13.7.20
Supplying and erecting fire brigade header of 150 mm dia, forsupplying water in fire tank complete as per specification no. FFFA/FBC item no 13-7-10
Supplying and erecting fire brigade header (Siamese connection) of 150 mm dia for supplying water to wet riser system complete as per specification no. FF-FFA/SMC
Supplying and erecting D.C.P. type fire extinguisher 6 kg capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets conforming to IS 2171-1985/ IS 15683 and complete erected with necessary clamps made from 50x6 mm M.S. flat with nuts & bolts grouted in wall complete. ITEM NO. 10.2.32
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall. ITEM NO. 10.2.36
Providing Round bottom FIRE Bucket of 9 Litrescapacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete.
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Supplying, installing, testing and commissioning 2 Zone, local signal control panel (LCP) with standard accessories complete as per specification no. FF-FAAS/LCP Item No 13-8-13
Supplying, installing, testing and commissioning manual call point (Pill box) with break glass push button in metal enclosure complete as per specification no. FF-FAAS/MCP Item No 13-8-5
Supplying, installing, testing and commissioning hooters with CRCAenclosure complete as per specification no. FF-FAAS/HTR Item No 13-8-6
Supplying, installing, testing and commissioning remote response indicators complete as per specification no. FF-FAAS/RRI Item no 13-8-7
Supplying, installing, testing and commissioning FR, XLPEarmoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CBLT/CU Item No 13-8-9
Supplying, installing, testing and commissioning optical type smoke detector complete on box as per specification no. FFFAS/SD item no 13-8-2
Supplying, installing, testing and commissioning four wireconventionally single ended reflected type beam smoke detector with 8" receiver . The range of smoke detector is max 325 feet. Item no 13-8-4
Supplying, installing, testing and commissioning of 2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories complete as per specification no. FF-FAAS/FACP item no 13-8-12
Supplying, erecting, testing and commissioning of 15 mm (½") dia. NBCM Body chrome finished quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR Item No 13-10-1
Supplying, erecting, testing and commissioning vane type water flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines of 100 mm dia having following features 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4) Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes Item No 13-10-3
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 100 mm dia with necessary fittings complete as per specification no. FFPP item no. 13.5.6
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 75/80 mm dia with necessary fittings complete as per specification no. FF-PP item no. 13.5.5
Supplying and erecting G.I. pipe above ground of ‘C’ class ERWof size 65 mm dia with necessary fittings complete as perspecification no. FF-PP item no 13.5.4
Supplying and erecting G.I. pipe above ground of ‘C’ class ERWof size 50 mm dia with necessary fittings complete as perspecification no. FF-PP item no 13.5.3
Supplying and erecting G.I. pipe above ground of ‘C’ class ERWof size 25 mm dia with necessary fittings complete as perspecification no. FF-PP item no 13.5.2
Supplying and erecting G.I. pipe above ground of ‘C’ class ERWof size 20 mm dia with necessary fittings complete as perspecification no. FF-PP item no 13.5.1
Supplying and erecting cast iron double flange NRV of size 100 mm dia complete as per specification no. FF-VL/NRV item no. 13.6.20
Supplying & erecting cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. FF-VL/BFV item no. 13.6.16
Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FFFFA/PG item no. 13.7.14
Supplying and installing pressure switch with 12/15 mm diaisolation valve, G.I. nipple, elbow, etc complete as perspecification no. FF-FFA/PS item no 13-7-15
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV item no. 13.7.13
Ellora Construction Pvt Ltd
N K Construction
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf