| Sl No | Description | Qty | Unit | SMK ENTERPRISES L1 | G. Suresh L2 |
|---|---|---|---|---|---|
| 1.00Removing the burst DI pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipeline with sound pipe including jointing and cost of refilling the pipeline with water for retesting the pipe line etc complete. (including cost of sound pipe and jointing materials and earth work) and as directed by the Corporation Officers. | |||||
| 1.01 | 100mm dia DI Pipes | 18 | RM | 1,820 ₹32,760 | 1,900 ₹34,200 |
| 1.02 | 150mm dia DI Pipes | 18 | RM | 2,850 ₹51,300 | 3,000 ₹54,000 |
| 1.03 | 200mm dia DI Pipes | 18 | RM | 3,900 ₹70,200 | 4,000 ₹72,000 |
| 1.04 | 250mm dia DI Pipes | 12 | RM | 5,295 ₹63,540 | 5,300 ₹63,600 |
| 1.05 | 350mm dia DI Pipes | 12 | RM | 7,610 ₹91,320 | 7,700 ₹92,400 |
| 1.06 | 400mm dia DI Pipes | 10 | RM | 9,640 ₹96,400 | 9,700 ₹97,000 |
| 2.00Maintenance and repairs the existing CI Sluice valve in various places for Municpal limit including cost of earth work excavation, gland rope with necessary bolts and nuts fixing including cost and conveyance of all materials and labour charges etc., complete as directed by the departmental officers | |||||
| 2.01 | 100mm dia CI Sluice Valve | 5 | Nos | 1,700 ₹8,500 | 1,800 ₹9,000 |
| 2.02 | 150mm dia CI Sluice Valve | 5 | Nos | 2,400 ₹12,000 | 2,500 ₹12,500 |
Tender Value
₹10 L
EMD Value
₹10,000
Closing Date
24 Sept 2025, 3:00 pmClosed
The Commissioner, Tambaram Corporation
1, Muthuranga Mudali St, West Tambaram, Tambaram, Chennai, Tamil Nadu 600045
Annual Maintenance and Repairs to water supply works DI Pipe line bursts and alied works at Ward No. 5,6,7 in Tambaram City Municipal Corporation Zone No.1
2025_DMA_603089_3
2515/2025/E1/Z1
Open Tender
Maintenance Works
Zone No.01
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹10,000
31 Dec 2025
12 Sept 2025
24 Sept 2025
12 Sept 2025
24 Sept 2025
12 Sept 2025
Amount
Removing the burst DI pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipeline with sound pipe including jointing and cost of refilling the pipeline with water for retesting the pipe line etc complete. (including cost of sound pipe and jointing materials and earth work) and as directed by the Corporation Officers.
100mm dia DI Pipes
150mm dia DI Pipes
200mm dia DI Pipes
250mm dia DI Pipes
350mm dia DI Pipes
400mm dia DI Pipes
Maintenance and repairs the existing CI Sluice valve in various places for Municpal limit including cost of earth work excavation, gland rope with necessary bolts and nuts fixing including cost and conveyance of all materials and labour charges etc., complete as directed by the departmental officers
100mm dia CI Sluice Valve
150mm dia CI Sluice Valve
200mm dia CI Sluice Valve
250mm dia CI Sluice Valve
350mm dia CI Sluice Valve
400mm dia CI Sluice Vale
Replacement of Underground Utilities (AC Pipe) damaged during Earthwork excavation for pipe laying works including cost of additional earthwork excavation in all soil strata, including BT/CC road cutting , removal of slushy soil and replacing the pipeline with sound DI s/s pipe, including supply and delivery of DI s/s pipes, D/S collars, jointing materials and required specials, cutting, conveying , laying, jointing and cost of refilling for the additional earthwork etc complete and as directed by the TWAD board officers.
200mm Dia
250mm Dia
300mm Dia
Providing water supply house service connection in BT(or) CC Roads from distribution main into houses up to 6M length ie, supply and fixing of following pipe and required materials including cost and conveyance of all materials to work site, all labour charges, incidental charges, road cutting charges, refilling the trench with excavated earth and compacting as directed by the departmental officers.etc complete as per standard specifications. i) PVC pipe 15mm dia or PE 80 PN 16 Blue or White pipe as per ISO183 IS make ISI Quality as per ISO 4427 – 6Rm ii) 20 mm size PVC Ferrule -1No iii) suitable PVC Saddle piece (or) MS saddle -1 No iv) 20 mm stop cock – 1No