Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.0 CrAccepted-AOC NA | ₹1.0 Cr | L-1 | Accepted-AOC Being lowest and reasonable. |
| 2 | L-2₹1.1 CrRejected-Finance | ₹1.1 Cr | L-2 | Rejected-Finance Not being lowest bidder. |
| 3 | L-3₹1.1 CrRejected-Finance H NO 17036 9 STREET NO 5 A AGGARWAL COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹1.1 Cr | L-3 | Rejected-Finance Not being lowest bidder. |
| 4 | L-4₹1.2 CrRejected-Finance MCB Z 2 13519 ST NO 4 GREEN AVENUE BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹1.2 Cr | L-4 | Rejected-Finance Not being lowest bidder. |
| 5 | L-5₹1.2 CrRejected-Finance PLOT NO D 25 INDUSTRIAL GROWTH CENTRE MANSA ROAD BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹1.2 Cr | L-5 | Rejected-Finance Not being lowest bidder. |
| Sl No | Description | Qty | Unit | M/s MITTAL CONSTRUCTIONS L3 | M/s PANKAJ KUMAR L9 | M/s Kataria Construction Company L6 | P K BANSAL CONTRACTOR L1 | ANNPOORNA ENGINEERS & BUILDERS L8 | SHARDA ENTERPRIES L7 | N.G BUILDERS L4 | M/S VERMA BUILDERS & DEVELOPERS L5 | RINKU BROTHERS L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fixing in replacement 15mm bore bib tap, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-charge. | 48 | Each | 800 ₹38,400 | 900 ₹43,200 | 650 ₹31,200 | 800 ₹38,400 | 750 ₹36,000 | 750 ₹36,000 | 650 ₹31,200 | 600 ₹28,800 | 700 ₹33,600 |
| 2.00 | Supply & fixing in replacement 15mm bore chromium plated, Stop valves, cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge. | 120 | Each | 650 ₹78,000 | 650 ₹78,000 | 550 ₹66,000 | 700 ₹84,000 | 550 ₹66,000 | 750 ₹90,000 | 600 ₹72,000 | 700 ₹84,000 | 550 ₹66,000 |
| 3.00 | Supply & fixing in replacement 15mm bore chromium plated, Concealed type Stop valves, cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge. | 24 | Each | 1,200 ₹28,800 | 1,000 ₹24,000 | 600 ₹14,400 | 1,000 ₹24,000 | 800 ₹19,200 | 950 ₹22,800 | 800 ₹19,200 | 1,000 ₹24,000 | 800 ₹19,200 |
| 4.00 | Supply & fixing Gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 20mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note: Labour element of taking down old unservicable Gun metal globe or valve is included under serial item no.34 .00 of Schedule 'A' BoQ here-in-after and nothing shall be extra paid on this account under this item. | 24 | Each | 750 ₹18,000 | 450 ₹10,800 | 600 ₹14,400 | 400 ₹9,600 | 500 ₹12,000 | 850 ₹20,400 | 700 ₹16,800 | 600 ₹14,400 | 500 ₹12,000 |
| 4.01 | Supply and Fixing Ball valve high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore (minimum weight 20mm-210 gram) complete all as specified and as directed by Engineer-in- charge.
Note: Labour element of taking down old unservicable Ball valve is included under serial item no.34 .00 of Schedule 'A' BoQ here-in-after and nothing shall be extra paid on this account under this item. | 24 | Each | 300 ₹7,200 | 450 ₹10,800 | 500 ₹12,000 | 250 ₹6,000 | 300 ₹7,200 | 350 ₹8,400 | 350 ₹8,400 | 350 ₹8,400 | 200 ₹4,800 |
| 5.00 | Supply and Fixing in replacement 15mm bore, brass Chromium Plated central hole basin mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and as directed by Engineer-in- charge. | 24 | Each | 3,000 ₹72,000 | 1,800 ₹43,200 | 2,000 ₹48,000 | 2,500 ₹60,000 | 4,000 ₹96,000 | 4,500 ₹1.1 L | 3,000 ₹72,000 | 2,500 ₹60,000 | 2,800 ₹67,200 |
| 6.00 | Supply and Fixing in replacement 15mm bore Brass Chromium Plated sink mixer for mixing hot & cold water screwed down for iron pipe and fixed regular swinging spout (wall mounted model) with connecting legs & wall flanges complete all as specified and as directed by Engineer-in- charge. | 24 | Each | 3,000 ₹72,000 | 3,500 ₹84,000 | 2,000 ₹48,000 | 2,500 ₹60,000 | 3,200 ₹76,800 | 4,500 ₹1.1 L | 3,000 ₹72,000 | 2,500 ₹60,000 | 3,200 ₹76,800 |
| 7.00 | Supply and Fixing High flow, Single lever diverter with brass concealed body, size 46mm, cartridge with butlon assembly , cartridge sleeve including chrome plated finishes exposed parts kit consisting of operating lever and wall flange with O- rings for 15mm bore pipe complete all as specified and as directed by Engineer-in- charge. | 24 | Each | 9,000 ₹2.2 L | 3,500 ₹84,000 | 7,500 ₹1.8 L | 1,000 ₹24,000 | 3,800 ₹91,200 | 5,500 ₹1.3 L | 6,000 ₹1.4 L | 3,500 ₹84,000 | 4,500 ₹1.1 L |
| 8.00 | Supply and fixing in replacement brass chromium plated shower rose 125 mm size, with swivel joints, including fixing to steel pipe or union, complete all as specified and as directed by Engineer-in-charge. | 24 | Each | 1,200 ₹28,800 | 400 ₹9,600 | 750 ₹18,000 | 300 ₹7,200 | 600 ₹14,400 | 350 ₹8,400 | 400 ₹9,600 | 300 ₹7,200 | 500 ₹12,000 |
| 9.00 | Supply & fixing in replacement PVC waste pipe of 32/40mm dia with socket suitable for connection to Waste fittings , and of length minimum 75 cm complete all as specified and directed by Engineer-in-charge. | 48 | Each | 80 ₹3,840 | 60 ₹2,880 | 70 ₹3,360 | 40 ₹1,920 | 120 ₹5,760 | 100 ₹4,800 | 60 ₹2,880 | 75 ₹3,600 | 50 ₹2,400 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
11 Oct 2025, 6:00 pmClosed
CWE Bathinda
HQ CWE Bathinda Bathinda Mil Stn
SPECIAL REPAIR TO MD ACCN NO. P-25 AND P-27 (12 x QTRS EACH ) AT RWA RANJIT ENCLAVE AGAINST JOB NO. 81SA/BTD/SR(BLDG)-02/2025-2026 UNDER GE (SOUTH) BATHINDA AT BATHINDA MIL STN
2025_MES_729722_1
CWE BTD/TOKEN-21/2025-26
Open Tender
Civil Works
300 days
Bathinda Mil Stn
As per NIT
7 documents required · 7 mandatory
₹1,000
GE (S) Bathinda
₹2.2 L
HQ CWE Bathinda
6 Jan 2026
6 Sept 2025
13 Oct 2025
6 Sept 2025
11 Oct 2025
4 Oct 2025
16 Sept 2025
Amount
Supply and fixing in replacement 15mm bore bib tap, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-charge.
Supply & fixing in replacement 15mm bore chromium plated, Stop valves, cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement 15mm bore chromium plated, Concealed type Stop valves, cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fixing Gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 20mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note: Labour element of taking down old unservicable Gun metal globe or valve is included under serial item no.34 .00 of Schedule 'A' BoQ here-in-after and nothing shall be extra paid on this account under this item.
Supply and Fixing Ball valve high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore (minimum weight 20mm-210 gram) complete all as specified and as directed by Engineer-in- charge. Note: Labour element of taking down old unservicable Ball valve is included under serial item no.34 .00 of Schedule 'A' BoQ here-in-after and nothing shall be extra paid on this account under this item.
Supply and Fixing in replacement 15mm bore, brass Chromium Plated central hole basin mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing in replacement 15mm bore Brass Chromium Plated sink mixer for mixing hot & cold water screwed down for iron pipe and fixed regular swinging spout (wall mounted model) with connecting legs & wall flanges complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing High flow, Single lever diverter with brass concealed body, size 46mm, cartridge with butlon assembly , cartridge sleeve including chrome plated finishes exposed parts kit consisting of operating lever and wall flange with O- rings for 15mm bore pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in replacement brass chromium plated shower rose 125 mm size, with swivel joints, including fixing to steel pipe or union, complete all as specified and as directed by Engineer-in-charge.
Supply & fixing in replacement PVC waste pipe of 32/40mm dia with socket suitable for connection to Waste fittings , and of length minimum 75 cm complete all as specified and directed by Engineer-in-charge.
Supply & fixing in replacement 450 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
Supply and Fixing in replacement vitreous china wash down water closet pan (pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe, etc. complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement Vitreous china wash hand basin, white, flat back, size 450mm x 300 mm including cast iron cantilever bracket with and including 32 mm dia brass waste coupling and with and including fixing of waste fitting and union complete all as specified and as directed by Engineer-in-charge.
Supply and fixing sink with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x460mm bowl size 410mm x330mm x160mm complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 32/40mm dia, waste fittings for stainless steel sink(sink coupling), brass chromium plated . with long screwed shanks and flynuts, flange end bedded in red lead cement complete all as specified and directed.
Supply and fixing Stainless steel plate rack made with Stainless Steel strip of 1mm thinck of size 900mm x 600mm x 250mm , fixed on wall etc. complete all as specified and as directed by Engineer-in-charge.
Material and Labour for Cutting holes in brick walls built in cement mortar (not exceeding half brick) for inserting hold fast and making good dismantled portion in CM 1:3 or Cement concrete 1 : 2 : 4 , type B1 as required , depth of embedded portion exceeding half brick walls and not exceeding one brick of hold fast or lugs measured from the face of the jamb into walls complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing in replacement PVC valveless, syphonic action type, flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle including brackets including 32 mm dia flush pipe of polyethylene of low or high density of PVC complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in replacement Chromium Plated stainless steel grating (with or without waste hole), 125mm size, complete all as specified and directed Supply and fixing.
Supply and fixing in replacement stainless steel curtain rod 25mm dia, wall thickness of pipe not less than 16 guage and grade SS 304, including brackets and pair of decorated end knobs (finials), stop roller etc. as per site requirement, fixed to wall with fixing accessories,complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement of brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing in replacement 110 mm bore of pipe PVC (SWR) type B pipes single socket ring fit in any length with clamps as shown in BTD Drg No. 916 sheet 1/4 to 4/4 of stays to wall at a distance of 100-120mm away from walls complete all as specified and as directed by Engineer-in- charge. compete all as specified and as directed by Engineer - in-charge.
Supply and Fixing in replacement 110 mm bore of pipe PVC (SWR) type B pipes single socket ring fit in any length with clamps as shown in BTD Drg No. 916 sheet 1/4 to 4/4 laid in trenches complete all as specified and as directed by Engineer-in- charge. including
Supply and Fixing inreplacement 75 mm bore of pipe PVC (SWR) type B pipes single socket ring fit in any length with clamps as shown in BTD Drg No. 916 sheet 1/4 to 4/4 of stays to wall at a distance of 100-120mm away from walls complete all as specified and as directed by Engineer-in- charge. compete all as specified and as directed by Engineer - in-charge.
Supply and Fixing in replacement 75mm bore of pipe PVC (SWR) type B pipes single socket ring fit in any length with clamps as shown in BTD Drg No. 916 sheet 1/4 to 4/4 laid in trenches complete all as specified and as directed by Engineer-in- charge. including
Supply and Fixing in replacement 110mm bore, PVC SWR Type-B Bends (any radius), with oval access door complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing in replacement 75mm bore, PVC SWR Type-B Bends (any radius), with oval access door complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing in replacement 110mm bore PVC (SWR) Type-B branch piece, double (double Y) equal or unequal with oval access doors complete all as specified and as directed by Engineer - in-charge.
Supply and Fixing in replacement 75mm bore PVC (SWR) Type-B branch piece, double (double Y) equal or unequal with oval access doors complete all as specified and as directed by Engineer - in-charge.
Supply and Fixing in replacement 110mm bore PVC (SWR) Type B WC connector with lip ring/bent type fit WC outlet complete all as specified and directed by by Engineer-in- charge.
Supply and Fixing in replacement 110mm bore PVC (SWR) Type B Vent Cowl complete all as specified and directed by Engineer-in- charge.
Supply and Fixing in replacement 110mm dia PVC SWR Type-B, floor trap with grating incluing jointing to waste pipe fixed in cement concrete 1:2:4 type B1, using 20mm graded stone aggregates complete complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing 20 mm bore CPVC pipe SDR 11and plain CPVC SDR 11 fitting with and including all fitting and fixed to walls & ceilings or laid in floors, including taking down unservicable existing GI tubing of 20mm bore and fittings complete complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing 25 mm bore CPVC pipe SDR 11and plain CPVC SDR 11 fitting with and including all fitting and fixed to walls & ceilings or laid in floors, including taking down unservicable existing GI tubing of 25mm bore and fittings complete complete all as specified and as directed by Engineer-in-charge.
Supply & fixing in replacement Rotational Moulded Polyethylene water storage tank ISI Marked of capacity 500 litres (cylindrical vertical, with closed top), hoisted and fixed in position including making inlet and out let connection complete all as specified and as directed by Engineer-in-charge. (Note :- Ball valve and gate valve shall be measured & paid separately under appropriate items of Schedule 'A' BoQ.)
Material and Labour Mild Steel framed work of Gde Fe-410-0 or Fe-310-0 as in doors chowkats (single or double) of angles or other section with gusset plates, rails, braces, bands straps, hold fast grill, sink brackets, cooler stand etc, complete and including necessary welding for fixing flat iron for fixing hooks and hinges complete all as specified and directed by Engineer-in-Charge.
Supply & fixing Mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified & directed by Engineer-in-charge.
Material and Labour for Welding in repair not exceeding 6mm thickness of metal and not exceeding 2.50 cm in length complete all as specified and as directed by Engineer-in- charge.
Supply & fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Door Frame / Chowkhat of Size 45mm x 70 mm comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) fabricated with miter joints after applying PVC Solvant cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg /cum and screw withdrawl strength of 2200 N (face ) & 1100 N (Edge) minimum Compressive strength of 58 N /sqmm modulus of elasticity 900 N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retaident and fixed in position with and including MS hold Fast lugs / SS Dash Fastner of required dia and length with and including Supply & fixing (03 Nos Per Frame ) 100 mm long SS Butt Hinges with and making good with plastering/rendering etc. around the finished opening of the distrubed surface with Cement Mortar 1:4 complete all as specified and as directed by Engineer-in- charge.
Supply & fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Door Frame / Chowkhat with double rebate of Size 65mm x 100 mm comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) fabricated with miter joints after applying PVC Solvant cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg /cum and screw withdrawl strength of 2200 N (face ) & 1100 N (Edge) minimum Compressive strength of 58 N /sqmm modulus of elasticity 900 N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retaident and fixed in position with and including MS hold Fast lugs / SS Dash Fastner of required dia and length with and including Supply & fixing (03 Nos Per Frame ) 100 mm long SS Butt Hinges with and making good with plastering/rendering etc. around the finished opening of the distrubed surface with Cement Mortar 1:4 complete all as specified and as directed by Engineer-in- charge.
Supply & Fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Door Frame / Chowkhat with double rebate of Size 65mm x 125 mm comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) fabricated with miter joints after applying PVC Solvant cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg /cum and screw withdrawl strength of 2200 N (face ) & 1100 N (Edge) minimum Compressive strength of 58 N /sqmm modulus of elasticity 900 N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retaident and fixed in position with and including MS hold Fast lugs / SS Dash Fastner of required dia and length with and including Supply and Fixing (03 Nos Per Frame ) 100 mm long SS Butt Hinges with and making good with plastering/rendering etc. around the finished opening of the distrubed surface with Cement Mortar 1:4 complete all as specified and as directed by Engineer-in- charge.
Supply & Fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Plain flush door shutter size of 30 mm thick comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) having minimum density of 650 kg /cum and screw withdrawl strength of 1800 N (face ) & 900 N (Edge) minimum Compressive strength of 50 N /sqmm modulus of elasticity 850N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retardant and with and including Supply & Fixing of 02 Nos (per Leaf) Stainless Steel 150mm long Tower Bolt conforming to IS 15833-2009 with and including S&F of 02 Nos. (per Leaf) Stainless Steel 150mm long handle conforming to IS 208-2020 and 300mm Stainless Steel sliding door bolt 12mm dia with and including a minimum of 6 carriage bolts and nuts four on bolt plate and two on stapple plate and fixed conforming to IS 15834-2008 complete all specified and directed by Engineer -in-charge.
Supply & Fixing Factory Made 30mm thick Solid WPC ( Wood polymer Composite ) Wiremesh Door Shutter of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension rade ), calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cum , having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter for fixing Mosquito mesh and XTN aluminium mesh together on panel area of door except stiles and rails to be panelled with and including mesh with self tapping round headed scresws at required distance, screws and edges covered with feathered pvc edge beading all around of mesh and fixing stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws with and including 03 Nos door Stainless steel butt hings 100mm long with Stainlessd steel screws for each , 02 Nos stainless steel barrel tower bolts of extrude section, 150mm long (ISI marked) conforming to IS 15833-2009, 2 Nos stainless steel handles, 125 mm long, (ISI marked) conforming to IS 208-2020 , 01 No. of helical door spring of 300 mm length complete all as specified and as directed by Engineer-in-charge. Note: 1. Material test certificate of all the items and authentication should be compulsory provided by the manufacturing company 2. The rate of 03 Nos door Stainless steel butt hings 100mm long with Stainlessd steel screws for each , 02 Nos stainless steel barrel tower bolts of extrude section, 150mm long (ISI marked), 2 Nos stainless steel handles, 125 mm long, (ISI marked) , 01no. of helical door spring of 300 mm length is inclusive in this item and nothing shall be paid extra on this item..3 The rate of Mosquito mesh and XTN aluminium mesh is included in this item and nothing shall be paid extra on this account.
Supply and fixing Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed as in cupboards etc to catch support shutters of best quality all as directed by Engineer-in- charge.
Supply and fixing in replacement Magic eye for flush/panelled door shutter etc complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing in replacement Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws 100mm long size complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 4.00 mm thick, sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 4.0 mm thick Figured glass pin head type and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed
Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 18mm thick HDHMR board UV coating, exterior grade as approved by GE, with and including acrylic high gloss sheet of minimum 1.00mm thick over HDHMR board, anti fungal, moisture resistance, anti borer, as per IS 14587 for frame and shutter for kitchen cabinets / Cupboards (such as side wall, shutter, partition back side of etc. of cupboard and cabinets). complete all as specified and directed by Engg-in-charge.
Supply & fixing stainless steel cabinet / drawers handle having a length of 250mm and shape complete all as specified and directed.
Supply & fixing in replacement of Partial overlay / fully overlay hydraulic self closing concealed hinges having size 103mm x 64mm finish of nickel/silver as approved by GE complete all as specified and directed by Engg-in-charge.
Supply & fixing Stainless Steel continuous (piano) hinges 30mm width of flap, mild steel bright finish or electrogalvanised complete all as specified and directed by Engineer-in-charge.
Material and Labour 2nd Hard Wood plain fillets, square, rectangular or triangular in section, wrought, secured with nails/brads or secured with screws, sectional exceeding 3.00 Sqcm and not exceeding 6.00 sqcm complete all as specified and as directed by Engineer-in- charge.
Taking down chowkhats or frames with shutters of PVC door , wooden door shutter, wooden window shutter , Mild steel window and Mild steel ventilators (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed by Engineer-in- charge.
Taking down chowkhats or frames with shutters of PVC door ,wooden door shutter, wooden window shutter , Mild steel window and Mild steel ventilators (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 Sqm each complete all as specified and as directed by Engineer-in- charge.
Supply and fixing of factory made uPVC white colour Three track Slider Window including glass & mesh of area exceeding 1.00 Sqm and not exceeding 2.00 sqm each window made of extruded profiles of high impact modified grade manufactured from Tropicalized Blend with TiO2 and required additives, colorfast & being able to withsatand a weather resistance test of 16000 hrs on weathering apparatus, resistant to chemicals, and be fungal and vermin proof. The uPVC profile should be classed as self extinguishing to prevent support or enchancement of accidental fires. Extruded profile duly reiniforced with minimum 120 gsm zinc coated GI of 1.5mm to 2.5mm thickness to meet the wind load requirement on sash/mulilion and fitted in continuous length in closed chamber of required length (shape and size according to uPVC profile design). The internal drainage shall be isolated from chambers into which reinforcement can be placed or through which frame fixing passes. Drainage shall be either through the base or alternatively to the face, concealed by face drainage caps. uPVC systems must be fabricated with fusion welded corners and uPVC extruded glazing beads of appropriate dimensions with EPDM/TPE Gaskets. All hardware fitted must be of stainless steel, multipoint espag, plastic packers, plastic caps & necessary stainless steel screws, except handles to be of Zinc/Al alloy casted with powder coated, GI fasteners 100mm x 8mm size for fixing frame to wall. Outer frame of windows 118mm x 50mm , sash 45mm x 60mm consisting of multi chambered frame, sash 7 mullion/transom (wherever required), The sizes of the sections indicated are minimum and no additional cost shall be claimed for use of higher sections due to design considerations. The wall thickness of the profile shall be minimum 2.0 ± 0.2mm. The sheet glass shall be toughened of thickness 5mm. The wire mesh shall be of stainless steel stainless 0.36mm nominal dia of wire and average width of aperature 1.40 mm. After fixing the frame the gap between the frame and adjacent finished wall shall apply Silicon sealant to make joint, water proof of approved quality. There would be a conditional warranty of minimum 10 years on profile & 02 years on hardware from the date of completion. The uPVC system must be installed by profile manufacturer or their authorised agents only complete all as specified and as directed by Engineer-in- charge. (Note :- The rate of 5mm thick toughened glass for glazing and stainless steel wire mesh cloth 0.36mm nominal dia of wire and average width of aperature 1.40 mm is included in this item and nothing shall be paid extra on this account. Net opening will be measured for payment purpose.)
Material and Labour for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint ove with and incuding one coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-charge.
Material and Labour for preparation of old painted steel surfaces of any description not otherwise described over 10 cm width & girth by applying one coat of synthetic enamel paint of approved tint complete all as specified and directed by Engineer-in-charge.
Roughning of surfaces of old concrete floor by picking sweeping clean and washing down with water to remove dust etc.complete all as specified and as directed by Engineer-in-Charge
Material and Labour for Non Skid coloured ceramic tiles 7.0mm to 8.0mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm and not exceeding 0.18 Sqm, in floors etc including 10 mm thick bedding layer using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in white or coloured epoxy grout to match the shade of tile including necessary cutting as per site requirement complete all as specified and as directed by Engineer-in-charge.
Material and labour for 25mm thick cement concrete 1:2:4, Type-B-1 , using 20 mm graded stone aggregates as in floors, sub-floors etc. and finishing surfaces of concrete topping even and fair (without using extra cement), and finishing surfaces of concrete in sub-floors, sub-bases, etc. even and rough to receive the topping layer complete all as specified and directed by Engineer-in-Charge.
Material and Labour for Non Skid coloured ceramic tiles 7.0mm to 8.0mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm and not exceeding 0.38 Sqm, in floors including 10 mm thick bedding layer using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in white or coloured epoxy grout to match the shade of tile including necessary cutting as per site requirement complete all as specified and as directed by Engineer-in-charge.
Material and Labour for Non Skid coloured ceramic tiles 7.0mm to 8.0mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm and not exceeding 0.38 Sqm, in vertical surfaces as in skirting including 10 mm thick bedding layer using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in white or coloured epoxy grout to match the shade of tile including necessary cutting as per site requirement complete all as specified and as directed by Engineer-in-charge.
Material and Labour for glazed ceramic coloured tiles 7.5 mm to 8.5mm thick 450mm x 300mm size in verticle surface including 10mm thick backing coat using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement etc complete all as specified and as directed by Engineer-in-charge.
Material and labour Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and for concealed conduit wiring,water tubing etc, and making good cutting exceeding 10 cm but not exceeding 20 cm girth,for Brick walls all as specified and directed by Engineer in charge
Material and labour for machine cut kota stone slab 18mm-20mm thick as in flooring , laid over with and including 20mm thick cement screed bed in Cement Mortar in 1:6 , laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge.
Material and labour for machine cut kota stone slab 18mm -20mm thick as in vertical surfaces such as in riser of steps , skirting/ Dado and pillar laid over with and including 10mm thick rendering in Cement Mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete reinforced of any discription and in any position, including reinforcement cut as required to facilitate and including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge. Note:The weight of scrap iron for schedule of credit shall be ascertain by BOO as ordered by GE.The copy of BOO duly countersinged by GE shall be enclosed with final Bill.
Demolition of cement concrete un- reinforced of any description and in any position not otherwise specifically provided for and including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for RCC Nominal Mix (1:2:4) type B-1 (using 20 mm graded stone aggregate) for slabs supported on walls, shelves, beams and columns, lintels, fins, facia and spiral staircase etc and the like, complete all as specified and as directed by Engineer-in- charge. Notes: Reinforcement shall be measured and paid seperately under appropriate item of Schedule 'A' BoQ.
Material and labour for mild steel TMT bars 10mm dia and over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia including making of rungs, handles etc complete all as specified and as directed by Engineer-in-charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Material and labour for formwork to soffits of suspended slabs such as roof slab, floor slabs, landings and similar work not exc 200 mm thick (horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge.
Demolition of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description complete all as specified and as directed by Engineer-in-charge.
Material and Labour Brick work with sub class ‘B’ burnt clay old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed by Engineer-in- charge.
Material and labour Brick work with sub class 'B' old size burnt clay bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-charge.
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material & Labour for PCC 1:3:6 type C2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC 1:5:10 , type E-2 , using 40 mm graded stone aggregate as in foundations, filling and mass concrete and sunken floors complete all as specified and as directed by Engineer-in-charge.
Material and labour for Waterproofing treatment to sunken floor using acrylic based multipurpose polymer. The treatment shall be carried out as per manufactures specification. The treatment shall be include of the following elements also: 1. Surface preparation of substrate by removing all traces of contaminates, loose and friable particles, cement laitance oils and grease, water repellent coatings etc 2. Injection grouting using cementitious grout if required. The payment for injection grouting shall be made separately etc 3. Repair to the substrate, filling of blow holes/voids and surface leveling using appropriate products specified by the manufacture. 4. All intersections of horizontal and vertical surface should be profiled with a mortar fillet of minimum 25mm x 25mm. 5. The moisture content of the substrate shall be checked before application of first coat at water proof coating at the rate of 200 g/m2 followed brush topping at 450g/m2 per mm. The second coat shall be reinforced with glass fabric between the first and second coat. 6. The treatment shall be protected by application of polymer modified cement mortar of thickness 10mm applied at the rate of 50g per mm. 7. Tech specification : Tensile adhesion strength 0.5N/Sqmm (as bonding slurry).
Supply only Liquid water proofing compound complete all as per manufacturer's instructions.
Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, et complete all as specified and as directed by Engineer-in-charge.
Material and Labour for preparing new plastered surfaces of ceilings and applying three coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and directed by Engineer-in- Charge.
Material and Labour for preparing existing treated surfaces of ceilings including cornices and applying one coat of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by Engineer-in-Charge.
Complete removal of existing treatment of any type/description from walls/RCC surfaces/ceiling/chajjas/roof projections etc with mechanical means/grinder complete all as specified and directed by Engineer-in- Charge.
Material and Labour for applying acrylic wall care putty on internal surfaces and external surfaces of walls/ceilings/soffits (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and leveling of surfaces in two or more layers) by using ready made acrylic wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed by Engineer-in- Charge. Make of acrylic wall care Putty : AS described in LIST OF MAKES/MANUFACTURERS under Appendix 'B' here-in-after. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order. (ii)The make of acrylic wall care putty shall be as per the recommendation of manufacturer of paint.
Material and Labour for prepration of surfaces with and including applying 02 coats of Interior Acrylic Emulsion Paint (shade as approved by GE ) , @ 10.00 Sq.m / litre / 2.00 coats by using roller to internal wall surfaces over with and including one coat of Interior Acrylic Emulsion Primer @ 10.00 Sq.m / litre / 1.00 coat by using roller as recommended for under coat by manufacturer of Interior Acrylic Emulsion by using the brands of Interior Acrylic Emulsion Paint and Interior Acrylic Emulsion Primer as described in LIST OF MAKES/MANUFACTURERS under Appendix 'B' here-in-after complete all as specified and directed by Engineer-in- Charge.
Material and Labour for prepration of surfaces with and including applying 02 coats of Exterior Acrylic Emulsion Paint (shade as approved by GE) with highlighter of any approved shade, @ 5.00 Sq.m / litre / 2.00 coats by using roller to External walls/ RCC surfaces / Soffits of Chajjas / Roof projections / Cantilevers / Balcony etc surfaces over with and including one coat of Exterior Acrylic Emulsion Primer @ 11.00 Sq.m / litre / 1.00 coat by using roller as recommended for under coat by manufacturer of Exterior Acrylic Emulsion by using the brands of Exterior Acrylic Emulsion Paint and Exterior Acrylic Emulsion Primer as described in LIST OF MAKES/MANUFACTURERS under Appendix 'B' here-in-after complete all as specified and directed by Engineer-in- Charge.
Material and Labour for prepration of surfaces with and including applying 02 coats of Exterior Acrylic Emulsion Paint (shade as approved by GE) with highlighter of any approved shade, @ 10.00 Sq.m / litre / 2.00 coats by using roller to External walls/ RCC surfaces / Soffits of Chajjas / Roof projections / Cantilevers / Balcony etc surfaces over with and including one coat of Exterior Acrylic Emulsion Primer @ 10.00 Sq.m / litre / 1.00 coat by using roller as recommended for under coat by manufacturer of Exterior Acrylic Emulsion by using the brands of Exterior Acrylic Emulsion Paint and Exterior Acrylic Emulsion Primer as described in LIST OF MAKES/MANUFACTURERS under Appendix 'B' here-in-after complete all as specified and directed by Engineer-in- Charge.
Material and labour for PCC 1:4:8 , Type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and Labour for machine pressed precast interlocking paver block 60 mm thick with grey cement and no pigment, factory made, any shape and size, conforming to IS 15658-2006, made out of M-35 grade concrete laid over and including 25 mm thick layer of sand cushioning complete all as specified and as directed by Engineer-in- charge. Note: The rate of 25mm thick layer of sand cushioning is included in this item and nothing shall be paid extra on this account.
Dismantling stone slabs and tiles (laid dry or laid dry and pointed ) of any description or thickness in floors, aprons etc. complete all as specified and directed by Engineer-in-charge.
Material and labour for granite (of any type) work 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including Material and labour for 15 mm thick screed in cement mortar (1:4) and finish the surface rough to receive the tile complete all as specified and as directed by Engineer-in-Charge. Note:- Sample of granite for Shade and type shall be approved by GE before procurement.
Dismantling of brick tiles or terracing tiles single layer on roof , disposal of retrieved material and stacking properly as directed by Engineer-in- charge.
Demolition of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof disposal off rubbish upto a distance not exceedomg 500.00mtr where directed ) complete all as specified and directed by Engineer-in- charge.
Material and labour for cement slurry @ 1.2 kg /sqm spreading with bristle brush with and including rendering 15 mm (average thickness) in cement mortar 1:3 finished even and fair mixing with Liquid water proof compound 200ml per 50 kg cement bag on roof surface complete all as specified and as directed by Engineer-in-Charge. Note:- Liquid water proofing comound shall be measured and paid seperately as supply only in appropriate item of schedule 'A' BoQ.
Material and Labour for Water proofing tratment to existing roof / terrace (material of water proof treatment as approved by GE) Single component, acrylic based, flexible, micro fibre reinforced waterproofing and heat reflective coating system. the treatment shall be carried out as per the manufacturers instructions and shall include the followings: (a) Preparation of substrate and cleaning it off all loose and triable by mechanical means (b) Open the cracks lines to form , V grooves with cutter/hammer/chisel up to 5-10mm and filling with crack filler and PU sealant. (c) application of primer coat @ 0.2 to 0.3 kg/ sqm followed by the first coat @ 0.75kg/ Sqm. (d) The second coat shall be applied @ 0.75 kg / Sqm and reinforced with fabric re-inforcement between the first and second coat. (e) The top coat of primer shall be applied after the second coat dries off @ 0.05-0.08 Kg per Sqm. (f) The material shall adhere to following specification. TECHNICAL SPECIFICATION OF MATERIAL Tensile Strength 1.5 MPa ASTM D412 Elongation at Break > 200% ASTM D412 Adhesion in Peel > 1.5 MPa (on concrete substrate) EN 1542 Crack Bridging Ability Passes upto 3.2mm Width ASTM C1305 Permeability to Water Vapour Passes IS 2645 Water Vapour Transimission ~ 23 g/m²/24hr ASTM E96 Water Absorption < 10% ( by Mass) ASTM D570 Microbiological Resistance No Algae & Fungal Growth ASTM D5590 Solar Reflectance Index 102 ASTM E1980. Note : Complete material shall be approved by GE and procured in bulk and kept in lock and key. Note : The installation company should be trained and authorized by Manufacturer & installation to be carried out as per manufacturers approved method statement. All auxiliary & accessories involved during application should be supplied by single manufacturer as a part of system. Any component used which is not manufactured by the particular manufacturer can only be used with official approval from manufacturer in consultation with GE.
Material and Labour for Making benching with PCC 1:2:4 type- B0, using 12.5mm graded stone aggregates using with Liquid Water Proof compound as per manufacturer's instruction along side wall adjoining to roof in concave shape complete all as specified and directed. Note : Liquid Water proofing compound shall be measured and paid separetly as supply only under appropriate item of Schedule 'A' BoQ.
Material and labour for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour 75mm thick PCC 1: 3: 6 type C-2 ( using 40mm graded stone aggregate ) in plinth protection, including finishing the surface even and smooth without using extra cement.complete all as specified and dircted by Engineer-in-charge.
Demolition and breaking up drain pipes SGSW,AC or reinforced concrete pipe up to and incl 150 mm bore pipes all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter depth for foundation etc or for shafts , wells, cesspits, manholes , septic tank, for laying of cables , laying of pipes not exceeding 10 Sqm on plan and not exc 1.5 meter depth and getting out in soft/loose soil etc complete all as specified and as directed by Engineer-in- charge.
Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
Supply ,laying and testing DWCPE (SN 8) drain pipes 150 mm nominal dia as per IS-16098 (Part-II), laid in trenches on bed including all accessories/ fittings/ jointed ring, jointing and testing complete all as specified and as directed by Engineer-in- charge. Note:- Excavation , earth work, bedding and pedestal / anchorage if required shall be measured and paid separately under appropriate item of BOQ/ Sch 'A'
Material and labour for PCC (1:3:6) type C-2 using 40 mm graded stone aggregates as in concrete bed of drain pipes of 150 mm bore, laid to required slope including packing under and haunching against the sides of pipes after they are laid and tested including form work complete all as specified and as directed by Engineer-in-charge. Note :- (i) Thickness of concrete bed below the barrel of pipe shall be 10 cm. (ii) Width of concrete bed shall be outer diameter of drain pipes (not of sockets / collar) plus 30cm.
Material and Labour for providing and injecting along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and as directed by Engineer-in-Charge.
Material & Labour for ATT At points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and as directed by the Engineer-in-Charge.
Material & Labour for ATT Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Cutting into existing manholes for connecting new drains for internal diameter of pipe 150mm bore, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing peg set/coat hooks (set of 4/5) of Stainless steel, complete all as specified and as directed by Engineer-in- charge.
Taking down carefully copper /aluminium point wiring (light, fan, socket , bell point, power point ) complete including fitting such as hylam , sheet switches, socket out lets , fan regulators , bell push switch , Electronic bell , Batten holder , ceiling rose, , sunken box, except concealed conduit etc. complete all as specified and directed by Engineer-in-charge. Notes: (i) The weight of aluminium scrap ,copper scrap and iron scrap (sunken box) shall be ascertain by BOO as ordered by GE and accordingly shall be considered in schedule of credit.The copy of BOO duly countersinged by GE shall be enclosed with final Bill. (ii) The rate of cutting chases (as required) and making good surfaces to match with adjoining surface shall be measured and paid seperately under serial item nos.117.00,118.00, 119.00,120.00,121.00 & 122.00 of BoQ.
Material and Labour for Concealed point wiring for modular type fittings using approved colour coding as per IS (Red, Black and Green for single phase circuits), with two single core 2.5 Sqmm nominal cross sectional area single core PVC insulated, unsheathed 'multi stranded' FRLSH copper cable, 1100 volts grade,ISI Marked with multi stranded copper conductor drawn through with and including non-metallic, rigid non mettalic PVC conduit (medium grade) 20mm bore surface on wall / ceiling with and including one single core 2.5 sqmm PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable ISI Marked as continuous earth continuity conductor (green in colour) including modular metal flush box concealied with front & modular cover plate with frame suitable matching colour of required module for mounting or housing modular switches 5Amp/ 6Amp , modular socket outlets 5 Amp / 6Amp, modular fan regulators, etc. including blanking plates & all other fixing accessories for one light/fan point controlled by one 5/6 Amps modular switch and including cutting chases (as required) and making good surfaces to match with adjoining surface complete all as specified and as directed by Engineer-in- charge Note for serial item no.117.00,118.00,119.00,120.00,121.00 & 122.00 : The quoted unit rate is deemed to be inclusive of cost of metal flush boxes, modular white cover plates, modular frame plates and flush fixed with cement mortar 1:4 etc.However modular switches 5Amp/ 6Amp , modular sockets out let 5Amp/ 6Amp , modular switches 15Amp/ 16Amp , modular sockets out let 15Amp/ 16Amp and modular bell push switch 5Amp/ 6Amp shall be measured and paid seperately under respective items of Schedule'A' BoQ. (ii) The rate of cutting chases (as required) and making good surfaces to match with adjoining surface is included in this item and nothing shall be paid extra on this account.
All as per item No 117.00 here- in -before but for one 3/5 Pin, modular Socket outlet 5 Amp, on same board complete all as specified and as directed by Engineer-in- charge.
All as per item No 117.00 here- in -before but for one 3/5 Pin, modular Socket outlet 5 Amp, on independent board complete all as specified and as directed by Engineer-in- charge.
All as per item No 117.00 here- in -before but for one 6 Pin, 6/16 Amp modular Socket outlet on independent board complete all as specified and as directed by Engineer-in- charge.
All as item No 117.00 here -in- before but for One light point controlled by Two way switch completed all as specified and directed by Engineer-in-chrage.
Material and Labour for Concealed point wiring for modular type fittings using approved colour coding as per IS (Red, Black and Green for single phase circuits), with two single core 1.5 Sqmm nominal cross sectional area single core PVC insulated, unsheathed 'multi stranded' FRLSH copper cable, 1100 volts grade,ISI Marked with multi stranded copper conductor drawn through with and including non-metallic, rigid non mettalic PVC conduit (medium grade) 20mm bore surface on wall / ceiling with and including one single core 1.5 sqmm PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable ISI Marked as continuous earth continuity conductor (green in colour) including modular metal flush box concealied with front & modular cover plate with frame suitable matching colour of required module for mounting or housing modular bell push switch etc. including blanking plates & all other fixing accessories for One bell / buzzer point controlled by one modular bell push switch and including cutting chases (as required) and making good surfaces to match with adjoining surface complete all as specified and as directed by Engineer-in- charge
Supply & Fixing Modular switch one way 6A, 1 module, complete all as specified and as directed by Engineer-in-charge. Note: .(i) Labour element for taking down old unservicable material is included in serial item no.116.00 of BoQ here-in -before and nothing shall be extra paid on this account.
Supply & Fixing Modular switch two way 6A, 1 module, complete all as specified and as directed by Engineer-in-charge. Note: .(i) Labour element for taking down old unservicable material is included in serial item no.116.00 of BoQ here-in -before and nothing shall be extra paid on this account.
Supply and fixing Modular Socket Outlet , Multipurpose,3/5 Pin, 6 Amp , 2 Module , ISI Marked complete all as specified and directed by Engineer-in-charge. Note: .(i) Labour element for taking down old unservicable material is included in serial item no.116.00 of BoQ here-in -before and nothing shall be extra paid on this account.
Supply and fixing Modular Socket Outlet , Multipurpose,2 in 1,6 Pin, 6/16 Amp , 2 Module , ISI Marked complete all as specified and directed by Engineer-in-charge. Note: (i) Labour element for taking down old unservicable material is included in serial item no.116.00 of BoQ here-in -before and nothing shall be extra paid on this account.
Supply and fixing Modular Switch one way 16 Amp 240 Volt, AC ,1 Module , ISI Marked complete all as specified and directed by Engineer-in-charge. Note: (i) Labour element for taking down old unservicable material is included in serial item no.116.00 of BoQ here-in -before and nothing shall be extra paid on this account.
Supply and fixing Modular Bell push Switch 6A 1 module , ISI Marked complete all as specified and directed by Engineer-in-charge. Note: (i) Labour element for taking down old unservicable material is included in serial item no.116.00 of BoQ here-in -before and nothing shall be extra paid on this account.
Supply and fixing Electronic Bell, ding dong type 230 Volt AC supply, complete all as specified and directed by Engineer-in-charge. Note: (i) Labour element for taking down old unservicable material is included in serial item no.116.00 of BoQ here-in -before and nothing shall be extra paid on this account.
Supply and fixing Modular Fan step regulator ( 0-05 Step) , 120W - 2 module complete all as specified and directed by Engineer-in-charge. Note: (i) Labour element for taking down old unservicable material is included in serial item no.116.00 of BoQ here-in -before and nothing shall be extra paid on this account.
Supply & fixing Batten holder polycarbonate cased body (B22 base), top line series, with back plate with and including LED Bulb 5 Watt B22 Base 100Lm/W,6000K complete all as specified and as directed directed by Engineer-in- charge. Notes: (a) Labour element for taking down old unservicable material is included in serial item no.116.00 of BoQ here-in -before and nothing shall be extra paid on this account. (b) Contractor has to furnish a replacement warranty of 02 years for LED Bulb complete including lamps from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :- (i) Manufacturing defects. (ii) Failure due to mechanical and electrical impact.
Supply & fixing ceiling rose surface type polycarbonate isolated body two to three terminal , Top line series 20x50mm, 6 amps three terminal complete all as specified and as directed by Engineer-in- charge. Note: (i) Labour element for taking down old unservicable material is included in serial item no.116.00 of BoQ here-in -before and nothing shall be extra paid on this account.
Supply and Fixing in replacement wall mounted LED batten fitting 1 x 20 watt, 6000K, min 100 Lumen per watt, 4 feet complete with decorative ultra slim, square profile linear LED lighting fixture with extruded polycarbonate, enviroment friendly, energy efficient complete as per manufacturer's instructions with and including connection with flexible twin core copper cable of size 23/.00076 from ceiling rose to fitting complete all as specified and as directed by Engineer-in- charge. Notes: (a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including lamps from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :- (i) Manufacturing defects. (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include to fix LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. (d) The rate of electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector is included in this item and nothing shall be paid extra on this account.
Supply and fixing in replacement Batten fitting square profile type LED mirror light fiting 9/10 watt, 6000K, polycarbonate body and all other accessories fitting arrangements all other accessories fitting arrangements complete all as per manufacturer's instructions with and including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector complete all as specified and as directed by Engineer-in-Charge. Notes: (a) Contractor has to furnish a replacement warranty of 02 years for miror LED Light fittings complete including lamps from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :- (i) Manufacturing defects. (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the miror LED Light fittings. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include to fix miror LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. (d) Old unservicable retrieved material shall be deposited in the store yard of AGE E/M GE (North) Bathinda by the contractor his own arrangements and nothing shall be paid extra on this account. (e) The rate of electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector is included in this item and nothing shall be paid extra on this account.
Supply & Fixing in replacement Building Security LED Light of 35 watt , IP 66 , luminaire with high power with toughened glass complete as per manufacturer's instructions with and including bracket made out with 40mm bore Galvanised Iron Light grade pipe 1.20 mtr length bent to shape with 02 sets of MS clamps made out of minimum 3 mm MS flat iron with suitable bolt ,nuts and washers complete and fixing to wall / column with and including electrical connection with 1.5 mtr long twin core round copper conductor cable of suitable size and testing complete all as specified and directed by Engineer-in-charge. Notes: (a) The rate of bracket made out with 40mm bore Galvanised Iron Light grade pipe 1.20 mtr length bent to shape with 02 sets of MS clamps made out of minimum 3 mm MS flat iron with suitable bolt and nuts and electrical connection with 1.5 mtr long twin core round copper conductor cable of suitable size is included in this item and nothing shall be paid extra on this account. (b) Contractor has to furnish a replacement warranty of 02 years for Security LED Light fittings complete including lamps and SPD from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :- (i) Manufacturing defects. (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include to fix Security LED Light fittings walls/building which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account.
Material and Labour in replacement for Sub main wiring concealed PVC conduit with two single core of size 6.00 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked drawn in and including non metallic rigid PVC conduit medium quality of size 25 mm dia conforming to 3537 Part-I ISI marked including one single core of size 6.00 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked as in contineous earth conductor cable connected to earth dolly complete all as directed. (Colour code phase-Red, Neutral-black and Earth as Green) complete all as specified and as directed by Engineer-in- charge. .Notes:-(a) Cost of PVC conduit , conduit accessories and earth wire included in sub main wiring. (b) Three single core 6.00 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked including non metallic rigid PVC conduit of size 25 mm dia ISI Marked shall be measured as one length.
Supply and Fixing in replacement Sheet metal enclousers made out of CRCA mild steel sheet not less than 1.2mm thick,, IP-54 protection, flush mounted for metal door, powder coated DB TPN 4 way, 415 V AC with 200 Amps rated copper bus bar, Double door, dust and vermin proof suitable for incorporation of Incoming MCB and outgoing MCB SP/TP and earth & neutral bus bar etc complete all as specified and as directed by Engineer-in- charge.Note: MCB/ Isolators shall be measured and paid seperately under appropriate item of BOQ.
Supply and fixing in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated copper bus bar) SPN, 12 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing MCB ‘C’ curve suitable for 230 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA , ISI Marked complete all as specified and as directed by Engineer-in-charge. Note: (i) Labour element for taking down old unservicable material is included in serial item no.137.00 & 138.00 of BoQ here-in -before of BoQ here-in -before whereas applicable nothing shall be extra paid on this account.
Supply and Fixing MCB SPN 20 Amp to 32 Amps, 10 KA, ‘C’ Curve, 230 V AC,50 Hz , ISI Marked including necessary attachment complete all as specified and as directed by Engineer-in- charge. Note: (i) Labour element for taking down old unservicable material is included in serial item no.137.00 & 138.00 of BoQ here-in -before of BoQ here-in -before whereas applicable nothing shall be extra paid on this account.
Supply and fixing RCBO for Earth Leakage , Overload & short circuit protection 415 Volt , 63 A , AC Type , 10KA, Four Pole, 30mA ISI Marked complete all as specified and as directed by Engineer-in-charge. Note: (i) Labour element for taking down old unservicable material is included in serial item no.137.00 & 138.00 of BoQ here-in -before of BoQ here-in -before whereas applicable nothing shall be extra paid on this account.
Material and Labour in replacement for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia medium grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note:- (i) Earth continuity of GI wire 4 mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Taking down ceilling fan and deposit in the safe custody / store yard of AGE E/M of GE (South) Bathinda complete all as specified and directed by Engineer-in- Charge,
Hanging of ceiling fan and connecting up with and including provision of suitable copper cable from ceiling rose or connector to fan complete all as specified and directed by Engineer-in- Charge,
Dismantling and taking down of existing energy meter and refixing the same complete all as specified and directed by Engineer-in- Charge,
Dismantling and taking down existing Geyser and deposit in the safe custody / store yard of AGE E/M of GE (South) Bathinda and refixing the same after carring out repair work/ rewiring I Accn )complete all as specified and directed by Engineer-in- Charge,
Note :1. The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender from total amount of Schedule 'A'/BOQ
RINKU BROTHERS (BID ID -3448740)
M/s MITTAL CONSTRUCTIONS (BID ID -3447936)
N.G BUILDERS (BID ID -3448758)
M/S VERMA BUILDERS & DEVELOPERS (BID ID -3443700)
M/s Kataria Construction Company (BID ID -3448178)
SHARDA ENTERPRIES (BID ID -3448497)
ANNPOORNA ENGINEERS & BUILDERS (BID ID -3448792)
M/s PANKAJ KUMAR (BID ID -3447957)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid