Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 107 265 BRAHAMA NAGAR KANPUR UP 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | Admitted-Finance |
| 3 | Admitted-Finance 11A SECTOR G INDUSTRIAL AREA GOVINDPURA BHOPAL BHOPAL MADHYA PRADESH 462023 | BHOPAL | MADHYA PRADESH | 462023 | Admitted-Finance |
| 4 | Admitted-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹34.4 L
EMD Value
₹68,815
Closing Date
30 Sept 2020, 6:00 pmClosed
AGM (Engg.-Elect.)-III, AAI, DABH Airport, Indore.
Old Terminal Building DABH Airport, Indore.
Relocation of Perimeter Street Light Fittings Including Cabling at DABH Airport Indore 2020-2021
2020_AAI_58342_1
AAI/ID/ENGG(E)/ENIT-3/2020-21
Open Tender
Electrical Works
Works
90 days
AAI DABH Airport Indore.
Please refer Tender documents.
11 documents required · 11 mandatory
₹1,180
Airport Authority of India.
₹68,815
19 Oct 2020
23 Sept 2020
8 Oct 2020
24 Sept 2020
30 Sept 2020
24 Sept 2020
24 Sept 2020 - 29 Sept 2020
Amount
Supply of XLPE insulated & PVC sheathed armoured aluminium conductor under ground cable of 1.1KV grade conforming to I.S : 7098 (Part-I ) with upto date ammendments as per approved list of AAI. a) 4C x 16 sqmm
Supply of 80mm dia 'B' class GI Pole of, bottom welded with 300X300X3mm thick MS Sheet , including sockets, reducers , pipe threading/ welding , etc. complete as required as per site requirement for the following Height Pole . a) 1.8Mtr ( Vertical Height Excluding Arm)
Supply of cross arm of suitable shape/ L shape of 50mm dia GI pipe not less than 0.5 mtr with required angle, including sockets, reducers , pipe threading/ welding , etc. complete as required as per site requirement for fitting at the upper part of the 80mm dia GI pole of height 1.8 meter height.
Supply of high efficency and low power consumption LED luminaire giving minimum 110 lumens/watt and powder not exceeding 36 Watt with power coated pressure die-cast aluminium housing with toughened glass /polycabonate cover and manufacturer name to be embossed on the luminaire having minimum IP 65 protection , weatherproof gasket and control gear compartments, integral electronic driver with THD < 10%, PFequal to .95 or more,luminaire shall have a life class of not less than 50,000 burning hours @L70, CRI minimum 70 suitable for mounting on existing bracket arm of 50 mm outer dia. compatible for luminaire.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. Mm
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required a) 4 x 16sqmm
Installation of the following GI street light poles with 1:2:4 Cement concrete to the required depth of size 400 mmx400mmx500 mm as per special conditions(1:cement :2coarse sand:4graded stone aggregate 20mm nominal size)and necessary base concrete of 1:5:10 for 100mm thickness below the pole (1cement :5 fine sand : 10graded stone aggregate 40mm nominal size) suitable finishing on surface above the ground level, including painting and numbering etc complete as required. a) UPTO 3 Mtr POLE
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry/exit including bending the pipe to the required shape complete as required a)40 mm dia ( Medium Class)
Installation ,testing and commissioning of LED fitting on existing pole with 2 x 1.5 sqmm PVC insulated copper conductor cable from cable looping box to fitting etc as required. b) For pole upto 2Mtr
Providing and fixing of SMC box of size 225mm x295 mmx 122 mm on existing tubular pole with suitable 2nos. clamps of 5mm thickness including providing and fixing 1 no. 6 amp SP MCB and 1 no. 4 pole connector along with necessary connections etc as required.(Make hensel ; Cat no.KF3500G) or equivalent approved make.
Relocation of perimeter pole from existing location to new location (approx 2 mtr back).Job includes excavation of existing pole from ground, relocating and fixing the existing pole to the new location etc as required and making good the same as per site conditions.
Messers Rajesh Gawde
N L Neema
Techno Electricals
Manish Electricals
RVD INFRA SOLUTION PVT.LTD.
Awasthi Electric Works
ENERGYGREEN TECHNOPOWER PVT LTD
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .