Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC 640 MAIN ROAD BABINA CANTT JHANSI UP 284401 | JHANSI | JHANSI | UP | 284401 | L1 | Accepted-AOC Being a L1 bidder | |
| 2 | L2₹38.9 L+₹497 (0.01%)Rejected-Finance D12 GROTH CENTRE COLONY BIJAULI JHANSI U P | JHANSI | UTTAR PRADESH | 284001 | L2 | Rejected-Finance Other than
lowest
bidder | |
| 3 | L3₹39.9 L+₹1.1 L (2.72%)Rejected-Finance 1010 NANDANPURA BABINA CANTT DIST JHANSI 284401 | BABINA CANTT | JHANSI | UTTAR PRADESH | 284401 | L3 | Rejected-Finance Other than
lowest
bidder |
Tender Value
₹43.7 L
EMD Value
₹87,500
Closing Date
3 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BABINA
GE BABINA CANTT 284401
SPECIAL REPAIR TO BLGD NO T-25 , T-21 AND CERTAIN MINOR WORKS AT AGE B/R-II AND AGE E/M UNDER GE BABINA
2022_MES_566593_1
GE/BAB/TOKEN/60 OF 2022-2023
Open Tender
Civil Works
Item Rate
180 days
GE BABINA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE BABINA
₹87,500
Yes
6 Apr 2023
1 Dec 2022
5 Jan 2023
1 Dec 2022
3 Jan 2023
15 Dec 2022
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Demolition of cement concrete (unreinforced )in ground floor and paving n,exc 15cm thickness below or above ground level)complete all as specified and as directed
Demolition of cement concrete (unreinforced) in any description and in any position not other wise specifically provided for complete all as specified and as directed.
Demolition of Brickwork of stone/boulder masonry, build in lime mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles etc complete all as specified and as directed.
M&L brick work with fly ash bricks (FASB) conforming to IS 12894, of strength M-10 straight or curved on plan exc 6m mean radious built cement mortar 1:4 complete (on parapet wall) all as specified and as directed.
Taking down cement plaster on brick or stone walls etc incl racking out joints hacking for key and scrabbing down with water etc complete all as specified and as directed.
Taking down 15 mm bore steel tubing and connection including cleaning and refixing or removal to store etc complete all as specified and as directed.
Taking down 20 mm bore steel tubing and connection including cleaning and refixing or removal to store etc complete all as specified and as directed.
S&F 15 mm bore galvanised mild steel tubing of medium grade with all fittings & fixed complete to walls & ceiling or laid in trenches/floors etc complete all as specified and as directed.
S&F 20 mm bore galvanised mild steel tubing of medium grade with all fittings & fixed complete to walls & ceiling or laid in trenches/floors etc complete all as specified and as directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) not exe 1.5 Sqm each etc complete all as specified and as directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) nexc 1.5 Sqm and n exc 4 sqm each etc complete all as specified and as directed.
Dismantling/demolition of existing water tanks of steel /PVC/RCC of capacity exceeding 250 liters but not exceeding 500 litres complete all as specified and as directed.
M & L for preparing surfaces of wall by complete removal of existing treament and applying two coat of oil emulsion distemper on walls complete all as specified and as directed.
M & L for complete removal of existing treament and applying two coat of cement base paint over a coat of alkali resistant priming paint on external surfaces of wall complete all as specified and as directed.
M&L for renderig 15mm thick in cement mortar 1:6 on fair faces of of brick or concrete surface of wall rendering is to be finished even and smooth without using extra cement complete all as specified and as directed.
M & L for preparation of new plastered surface and applying two coat of oil bound distemper on walls including chalk whitening on plastered surfaces ,preparatory to distempering complete all as specified and as directed.
M & L for preparation of new plastered surface and applying two coat of cement base paint over a coat of alkali resistant priming paint on external surface etc complete all as specified and as directed.
M&L for coloured joint free ceramic tiles 7 to 8 mm thick (square / rectengular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to floor, over and including 15mm thick screed bed or bedding layer in cementy mortar 1:4,etc complete all as specified and as directed.
M&L 25 mm thick cement concrete 1:2:4, type B-0, (using 12.5mm garded aggregate) as in sub base/floor complete all as specified and as directed.
M&L for glazed coloured ceramic tiles 300 x 600 x 7 mm thick for work on vertical surface such as skirting, dado, set & jointed in cement slurry and pointed in white or coloured cement to match the existing wall surfaces, over and incl 10mm thick rendering in cement mortar 1:4 etc complete all as specified and as directed.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls including taking down old PVC/CI/Concrete pipes complete all as specified and as directed.
S&F PVC (SWR) bends 110mm radius complete all as specified and as directed.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints laid in trenches including taking down old PVC/CI/Concrete pipes complete all as specified and as directed.
S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls including taking down old PVC/CI/Concrete pipes complete all as specified and as directed.
S&F PVC (SWR) bends any 75mm radius complete all as specified and as directed.
S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints laid in trenches including taking down old PVC/CI/Concrete pipes complete all as specified and as directed.
S&F 75mm bore CI floor trap complete all as specified and as directed.
S&F PVC (SWR) vent cowl 100mm bore complete all as specified and as directed.
S&F 100mm bore CI Nahani trap complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck in side with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail,paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement all as directed and specified by Engineer-in-Charge.
S & F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube etc complete all as specified and as directed.
S&F but hinges extruded aluminium alloy with galvanised mild steel hing pin, anodised and fixed, type C-21 100 mm size in toilet with PVC doors etc complete all as specified and as directed.
S&F aluminium anodised barrel tower bolts of extruded section and fixed fixed 200 mm long etc complete all as specified and as directed.
S&F aluminum handles cast type anodized 150 mm size etc complete all as specified and as directed.
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy complete all as specified and as directed.
M&L two coat synthetic enamel paint over one coat of red oxide primer on new steel surface of any description not otherwise described over 10 cm width or girth etc complete all as specified and as directed.
M&L preparation of old painted steel surfaces and applying one coat synthetic enamel paint on old steel surface of any description not otherwise described over 10 cm width or girth etc complete all as specified and as directed.
M&L for 75mm thick cement concrete 1:3:6 type C-2, (using 40mm graded aggregate) as in plinth protection /path finished even and smooth without using extra cement complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 , (using 20mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
S & F 500 litre capacity of rotational moulded polyethylene water storage tank multilayered construction, ISI marked of make specified (cylindrical vertical with closed top) hoisted and fixed in position including S & F 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings complete all as specified in SSR Part-I complete all as specified and as directed.
S & F in repair 20mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
S&F in repair 20 mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. .(Minimum weight 15mm-142gms/ 20mm-210 gms./25mm-455gms/ 40mm etc complete all as specified and as directed.
S&F in repairs vitreous china squatting pan 'ORISSA PATTERN ' size 580mm x 440mm 'white with integral foot rest (excluding flushing cistern and flush pipe ) with 'P' or 'S' trap, front or back inlet including connection to trap and to flushing pipe anti syphonage pipe etc complete all as specified and as directed
S & F Vitreous China Ware Wash hand basin white, flat back, size 450 x 300 mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand and waste pipe complete all as specified and as directed.
S&F in repairs 10 ltr capacity PVC low level flushing cistern white, ISI marked make as specified with inlet, float valve and handle including breacket with 32mm dia PVC pipe 600mm long complete all as specified and directed
S&F PVC connection 15mm dia with Brass nuts of length 450mm etc complete all as specified and as directed.
S&F in repair 15 mm bore angle stop cock long thread fancy type chromium plated cast copper alloy, screwed down high pressure with crutch or butter fly handle screwed both and for iron pipe or for union and fixed etc complete all as specified and as directed.
S&F in repair 15 mm bore bib taps long body chromium plated fancy type, cast copper alloy with crutch or butter fly handle screwed down screwed for iron pipe or for unions and fixed 15 mm bore etc complete all as specified and as directed.
Preparation of Old wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and as directed.
S & F 15mm bire pillar taps, Cast Copper alloy, with capstan heads, chromium plated, fency type screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
S&F towel rail 450mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 170 gms) complete all as specified and as directed.
S&F Soap dish chromium plated any type , fixed to plugs with chromium plated brass screwes complete all as specified and as directed.
Dismantling structural steel work of any description including doors, gates etc complete all as specified and as directed.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed.
S&F painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.Fe-290 Gde E-165 complete all as specified and as directed.
Dismentling ceiling boards (fibre, pulp, insulation, etc.) or nsulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
S&F of anodised aluminium snap grid frame work for false ceiling all as specified and hangers 4mm dia GI wire fixed to roof slab/ truss all as specified and as directed
S&F 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and as directed.
M&L second class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at joints, supplied and fixed complete all as specified and as directed.
S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides etc complete all as specified and as directed.
M&L for two coats of synthetic enamel paint over one coat of pink primer on new wooden surface of any description not otherwise described over 10 cm width or girth etc complete all as specified and as directed.
M&L RCC 1:2:4 type B1,(20mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc all as specified and directed as per Enger-in-charge.
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L Mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick on flat surfaces complete all as specified and as directed.
S&F sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed.
S & F factory made 30 mm thick IInd class HW glazed & skeleton shutters open rebated and prepared to receive glass gauge etc. (without sash bars) edges of framing plain chamfered or rounded fitted with cut & mitered beads for security glass/gauge etc. size of members of shutter as specified in SSR Pt I sec 8 Cl 8.20 (a), divided into squares with plain chamfered rounded, mitered and rebated sash bars etc complete all as specified and as directed.
S&F galvanized mild steel wire cloth 0.56 mm nominal dia of wire and avg width of aperture 1.18 mm fixed with tinned tacks or galvanized wire staples etc complete all as specified and as directed.
Dismantling timber scantling , framed /un framed work of 40 sq. cm and over in section in any position complete all as specified and as directed.
S&F mild steel work as in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade ST-240 with and including one shop coat of zinc chrominium primer paint complete all as specified and as directed.
S and F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts complete all as specified and as directed.
S and F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, including ancher nut, bolt & washer of any size as required etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by engineer in charge.
M&L Brick work with old size sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and as directed.
M and L for toothing and bonding with cement mortar (1:6) for openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and as directed.
M&L non skid ceramic colour tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm set and jointed in neat cement slurry and pointed in colour cement to match as in floor including 15 thick cement mortar screed bed 1:4 complete all as specified and as directed
M and L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M and L for Screed bed or bedding layer or mortar 15mm thick for laying floor finishes with CM (1:6) complete all as specified and as directed.
Taking down old existing unserviceable HDPE water storage tank and of capacity n exc 500 ltrs etc complete all as specified and as directed.
S&F in repair 15 mm bore stop valve (angle cock) cast copper alloy fancy type chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union and fixed complete all as specified and as directed.
S&F in repair 15mm bore bib taps, cast copper alloy, fancy type, chromium plated, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S & F in repair of Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) in repair including Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
S&F in repair vitreous china wash hand basin, white flat back, size 550mmx400mm fixed on and including cast iron cantilever brackets, 32mm dia brass waste coupling and including fixing of tap, waste fitting and union complete all as specified and as directed . Note: pillar tap shall be measured as supply only under respective items complete all as specified and as directed.
Supply only15mm dia pillar taps cast copper alloy with capstan heads, cromium plated screwed down high pressure with or without lettered Hot or Cold with long screw shanks abd fly -nuts screwed for iron pipe and fixed complete all as specified and as directed.
S&F PVC floor trap size 75mm dia out let with grating including connection to waste pipe with cement jointing complete all as specified and directed
S&F PVC (SWR) junction single, (single T) equal or unequal 110 mm bore complete all as specified and as directed.
S&F PVC (SWR) vent cowl 110 mm complete all as specified and as directed.
S and F of Grating doom 100 mm dia of PTMT (Minimum weight 25 gms) complete all as specified and as directed.
S and F of Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40 gms) complete all as specified and as directed.
S and F of Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms) complete all as specified and as directed.
M & L applying 1mm thick putty complete all as specified and as directed.
S&F Powder coated aluminium window/ventilator glazed shutter with glazing bar, single panel etc complete fixed type with section having weight n less than 0.55 Kg/RM and glazing with 5 mm thick figured glass including jointing cleats, glazing clips, suitable rubber packing, powder coated aluminium anodised snap beading, screws etc complete all as specified and directed. Note- The cost of tinted glass shall deemed to be included in unit rate.
S&F anodised aluminium grill DECO GRILL fabricated out of flat aluminium section of size 8 mm x 5 mm thick made to shape as directed (Design first got approved from the GE in writing before ordering for bulk fabrication) and fixed on aluminium window frame (refer item above) with suitable arrangement as per site requirements etc complete and as directed. Note : Cost of items required for fixing grill to window frame deemed to be included in unit rate quoted by the renderer.
S&F Door closer hydraulically regulated, designation No.1 universal type, suitable for door shutters up to 700 mm in width and of weight not more than 35 kg and fixed complete all as specified and as directed.
S&F, 150mm floor door stopper aluminium alloy body complete all as specified and directed.
S&F Vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed.
Taking down carefully unserviceable aluminium point wiring (light, fan, socket or power) complete with fitting such as switches, ceiling roses, lamp holders, sockets, fan regulators, wooden terminal box plastic laminated sheet cover from TW battens including TW batten or drawing from existing conduit removing including TW batten all as specified and as directed by Engr-in-Charge.
Taking down carefully existing wooden board , Main switch, MCB DB boxes with MCBs, sheet metal boxes, cut out, etc of any size any capacity from boards complete all as specified and as directed.
Taking down carefully sub main wiring / service connection twin core from wall / LT pole of any size of Aluminum with wooden batten and or through rigid conduit including GI wire and making good the disturbed surfaces of walls, roofs, floors etc complete all as specified and as directed.
M & L for concealed point wiring for one light point controlled by one switch complete with PVC insulated and unsheathed flame retardant low smoke ( FRLS ) cable of 1.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 19 mm dia, clip, with MS terminal boxes (not less than 1.0 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including common earth dolly with 3 mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete including cutting necessary chases on wall / ceiling surfaces for drawing of conduit & cables as required and making good disturbed surfaces of walls with CM 1:3:6 and matching with the existing surfaces including colour washing all as specified and as directed .
Description same as per item No 105 above but one fan point controlled by one switch & regulator.
Description same as per item No 105 above but One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
Description same as per item No 105 above but One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
Description all as per item No 105 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed flame retardant low smoke ( FRLS ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed.
S&F switch piano flush button type 5 Amp single pole one way complete all as specified and as directed.
S&F socket outlet 2in1, 3 pin, 5 Amp flush type complete all as specified and as directed.
S&F switch piano flush button type 15 Amp single pole one way complete all as specified and as directed.
S&F socket outlet 2in1, 3 pin, 5 Amp and 15 Amp flush type complete all as specified and as directed.
S & F delux Fan Regulator electronic rotary, step type 240 Volt 50 Hz, complete all as specified as directed.
S & F Lamp holder,PVC/Urea type with back plate suitable for batten fittings complete all as specified as directed
S&F LED security/street light fittings1x35W LED 5700K energy saving and envoiremental frendly long life versatile pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 luminaire with high power LED as light siurce and electronic driver suitable for pole dia 40mm including 40mm dia light grade tube bracket, bend to shape 1.80m long with two numbers clamp of size 50mmx6mm with nuts, bolts, washers etc including connection with 1.5Sqmm two single core PVC insulated and PVC sheathed cable stranded copper conductor upto ceiling rose and fixing on wall /pole complete as ditrected by Engineer in Charge. Make: Bajaj Cat Part No BRLEP20WLEDWH or equivalent make as specified in Appendix B to particular specification.
S & F 9W/10W LED retrofit lamp B-22 holder base with polycorbonate body and aluminium heat sink complete all as specified as directed. Make C&S Cat No LTHPLEDLAMP7W/B22 or equivalent make as specified in Appndx 'B' to PS .
S&F ceiling rose,surface bakelite 63 x50mm three terminals complete all as specified and as directed.
Removing excavated soil to a distance n exc 50 mtrs and depositing where directed at a level n exc 1.5m above starting point complete all as specifief and as directed.
S&F sheet metal enclosure with two pin socket, chain plug cover with one MCB SP of 20/32 Amp capacity with alignment 10KA 'B' series complete all as specified and as directed.
S&F in replacement of 36W LED of size 2feetx2feet 6500K rescessed mounting luminaire glare free suitable for armstrong/grid ceiling in MS/CRCA housing with high brightness LEDs incl wiring upto and terminating into existing ceiling rose complete all as specified and as directed.
M&L for sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLS, 1100 Volts grade cable drawn into conduit (Existing / new) including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete all as specified and as directed Note:- (a) Two runs of 6 sqmm cable and one run of 6 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) New conduit and conduit accossories shall be measured separately.
M&L for sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 4 sqmm FRLS, 1100 Volts grade cable drawn into conduit (Existing / new) including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 4 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete all as specified and as directed Note:- (a) Two runs of 4 sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) New conduit and conduit accossories shall be measured separately.
Supply and fixing light fitting energy saving new generation 10W LED IP65 bulkhead luminaire with opal diffuser including electrically connecting using flexible cord 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm. Make: Havells cat. part. No LHEOAOP7UZ6W010 or equivalent make as mentioned in appendix B to PS..
S & F MCCB 4 pole, 415V, AC, breaking capacity 16KA with fixed terminal and fixed magnetic setting of capacity 100Amps, 'C' series etc complete all as specified and as directed
S & F regid non-metallic PVC conduit not less than 20 dia (external) ISI marked (on surface) incl of all accessories and all fittings such as Tees,bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers,lock nuts, saddles, pipe hook etc complete all as specified and as directed
S&F TPN DB-DPX 125 MCCB DBs 4 way single door with provision for DPX 125 MCCB and as incomer and SP/TP MCBs as out going no of modules DPX 125+12,complete all as specified and as directed.
S&F sheet metal enclosure double door concealed suitable for distribution boards when MCBs to be used having 100 Amp rated bus bar 8 ways 240 V complete all as specified and as directed .
S&F MCB single pole and neutral 40 Amp/63 Amp 240 V ,10KA , 'C' series, connected with copper lugs complete all as specified and as directed
S&F MCB single pole 6 to 32Amps 240 V,10KA, 'C' series, connected with copper lugs complete all as specified and as directed.
Supply and fixing in repair 22W LED 6000k Decorative ultra slim linear LED fitting fixture with extruded polycarbonate ,environmental friendly ,energy efficentinterated driver and 22watts lamp fitted including wiring upto and terminal into ceiling rose complete all as specified and directed by Engr-in- Charge.
Supply and fixing exhaust fan AC single phase 230/240V of size 300mm sweep, 1400RPM with louvers complete including with all arrangement of making holes on wall, making good and finishing of disturbed surfaces, matching with the existing surfaces, necessary fixing arrangement such as fastener bolt, nuts, washers etc of appropriate size complete all as specified and directed.
Supply and laying XLPE insulated, armoured heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 16 X 4 sq. mm complete all as specified and directed.
Supply and laying dry clean sand free from sharp materials, unscreened filling in trenches around under ground cables for cushioning complete all as specified and directed.
Supplying and laying precast concrete cable cover class LV type -I flat size 250x150x40 mm laid parpendicular to the axis of cable in trenches etc complete as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1,5 mtrs in depth for laying of pipe/cable including getting out in any type of soil complete all as specified and directed.
Returning, filling in including spreading, leveling , watering and well ramming, in layers not exceeding 25 cm each layer of any kind of soil complete all as specified and as directed.
S&F Ceiling fan copper wound, 1200mm sweep, BEE star rating,AC single phase 230 V including all arrangement like hook,pipe of suitable size all as specified and directed.
Supply, fixing, testing and commissioning split type air conditioner with copper tubing, single phase AC 230 Volt, 1.5 ton capacity with a minimum 5 star (BEE) rating including necessary initial gas charging as required, fixing arrangement for outdoor and indoor unit and PCC (1:2:4) mounting platform of required dimensions for outdoor compressor unit, copper tubing of suitable size with insulation of the required length, PVC pipe 15mm dia, medium grade fixed to wall surface for condensed water outlet, electric connection with PVC insulated unsheathed aluminum conductor twin core cable of size 10 Sqmm from electric pole/panel complete all as specified and directed at site.
Supply, fixing, testing and commissioning split type air conditioner with copper tubing, single phase AC 230 Volt, 2 ton capacity with a minimum 5 star (BEE) rating including necessary initial gas charging as required, fixing arrangement for outdoor and indoor unit and PCC (1:2:4) mounting platform of required dimensions for outdoor compressor unit, copper tubing of suitable size with insulation to the required length, PVC pipe 15mm dia, medium grade fixed to wall surface for condensed water outlet, electric connection with PVC insulated unsheathed aluminum conductor twin core cable of size 10 Sqmm from electric pole/panel complete all as specified and directed at site.
Supply fixing, connecting and testing, automatic voltage stabilizer, wall mounted type, single phase, naturally air cooled, indoor type designed for input variation between 170 to 250 Volt and out put voltage stabilized at 230 Volts with accuracy of (+) 2.5% and capacity 5 KVA complete all as specified.
S&F MCB protected power unit include MCB SP 16A ot 25A, 220V 50Hz complete all as specified and directed Make : Havells/ Indoasian/ L&T
M&L galvanised iron pipe of 50 mm dia, light grade ISI marked, complete with fittings laid in trenches/ fixed with poles etc as protection to cables complete as ditrected by Engineer in Charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick weithing not less than 17.5 Kg buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 2009 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
FTH Traders
M/S M S Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .