Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 CrAccepted-AOC | ₹6.9 Cr Quoted ₹6.6 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | Rejected-Technical | - | - | Rejected-Technical As per Technical Evaluation Report |
Tender Value
₹5.9 Cr
EMD Value
₹5.9 L
Closing Date
10 Aug 2022, 3:00 pmClosed
Managing Director
Maharashtra State Agricultural Marketing Board, Plot No. R-7, Marketyard, Gultekadi, Pune 411 037
CW-1 c - Upgradation and Expansion of Existing Facilities at Nashik Division - Savda
2022_CMTAD_811600_1
MSAMB/ENGG/ADB/MAGNET/CW-1(c)
Open Tender
Civil Works - Others
Item Rate
365 days
Sawada District Jalgaon
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
Yes
₹5.9 L
Yes
MSAMB, Head office, Pune
13 Apr 2023
24 Jun 2022
10 Aug 2022
24 Jun 2022
10 Aug 2022
8 Jul 2022
24 Jun 2022 - 1 Jul 2022
4 Jul 2022
Export Facility Center, Savda, Taluka Raver, District Jalgaon
PART A : Work Portion
Civil Work
Clearing grass and removal of rubbish up to a distance of 50 metre outside the periphery of the area S.S.R.2021-22 Item No. 2.07 .
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.5 m.) by Mechanical Means. S.S.R.2021-22 Item No. 21.02
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.50 m) by Mechanical Means.. S.S.R.2021-22 Item No. 21.06
Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5 m to 3.0 m) by Mechanical Means. S.S.R.2021-22 Item No. 21.12
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. S.S.R.2021-22 Item No. 21.22
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. S.S.R.2021-22 Item No. 21.24
Filling in plinth and floors with contractors soil. Sand or murum materials in 15 cm to 20 cm layers including watering & compaction complete. S.S.R.2021-22 Item No. 21.37
Providing soling using 80mm size trap metal in 15 cm. layer including filling voids with crushed sand /grit ramming, watering complete. S.S.R.2021-22 Item No. 21.40
Providing and laying Cast in situ/ Ready Mix cement concrete M-15 of trap/ granite/ quartzite/ gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed). With fine aggregate (Crushed sand V.S.I. Grade). S.S.R.2021-22 Item No. 24.16
First Floor
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-15 of trap/ granite/ quartzite/ gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, plywood/ steel formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand V.S.I. Grade). S.S.R.2021-22 Item No. 24.08
Providing and laying in situ/ Ready Mix cement concrete M-25 of trap/ granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). S.S.R.2021-22 Item No. 25.13
Providing and laying cast in situ/ Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). S.S.R.2021-22 Item No. 25.33
First Floor
Second Floor
Providing and laying Cast in situ/ Ready Mix cement concrete M-25 of trap/ granite/quartzite/ gneiss metal for R.C.C. Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). S.S.R.2021-22 Item No. 25.52
First Floor
Second Floor
Providing and laying Cast in situ/ Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). S.S.R.2021-22 Item No. 26.07
First Floor
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). S.S.R.2021-22 Item No. 25.72
First Floor
Second Floor
Providing and fixing in position TMT FE -500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. S.S.R.2021-22 Item No. 26.33
First Floor
Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. S.S.R.2021-22 Item No. 39.09
First Floor
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm. with lock plate of 3.15 mm. thickness reinforced with 35 x 35 x 5 mm. angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm. and 3.15 mm. respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm. minimum size and shape with square bar, suspension shaft of minimum 32 mm. diameter, hood cover of M.S. sheet not less than 0.9 mm. thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 6248-1979) (Without mechanical gear). S.S.R.2021-22 Item No. 39.24
Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm. at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm. at weight 1.070 kg/Rmt. Top and side track section 92 x 31.75 x 1.30 mm. at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm. at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm. at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm. thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. complete with powder coating with box. S.S.R.2021-22 Item No. 39.43
First Floor
Providing and fixing mild steel grill work for windows, ventilators 20 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. S.S.R.2021-22 Item No. 40.01
First Floor
Providing fly ash brick masonary with conventional / I.S. type fly ash bricks in cement mortar 1:6 in foundation and plinth including bailing out water manually, striking joints, racking out joints, watering and scaffolding complete. S.S.R.2021-22 Item No. 27.12
Providing fly ash brick masonary with conventional / I.S. type fly ash brick in cement mortar 1:6 for superstructure including striking joints, racking out joints, watering and scaffolding complete. S.S.R.2021-22 Item No. 27.13
First Floor
Second Floor
Providing and laying Polished Kota stone flooring with Hand-Cut Polished Kota Stones 25 mm. to 30 mm. thick and required width in plain/ diamond pattern on bed of 1:6 cement mortar including cement float, filling joints with neat cement slurry, curing, cleaning and Mirror Polishing etc. complete. Note- Water absorption for Kota stone should not exceed 0.05%.( Item to be used with prior permission of Superintending Engineer ) S.S.R.2021-22 Item No. 33.75
First Floor
Providing sills of Granite 20 mm. to 25 mm. thick, on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing, rounding edges and cleaning complete. S.S.R.2021-22 Item No. 33.22
First Floor
Providing and laying polished machine cut machine polished Kotah stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning complete. S.S.R.2021-22 Item No. 33.18
First Floor
Providing internal cement plaster 12 mm. thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. S.S.R.2021-22 Item No. 32.03
First Floor
Second Foor
Providing internal cement plaster 6 mm. thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. S.S.R.2021-22 Item No. 32.02
First Floor
Second Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm. thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm. thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. S.S.R.2021-22 Item No. 32.11
First Floor
Second Floor
Providing and applying priming coat over concrete/Masonry/Asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, greese, dirt and other foreign matter and sand papering as required etc. complete. S.S.R.2021-22 Item No. 35.21
First Floor
Second Floor
Providing and applying plastic emulsion paint of approved quality, colour and shade to old/ new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat) complete. S.S.R.2021-22 Item No. 36.12
First Floor
Second Floor
Providing and applying two coats of exterior acraylic emulsion paint conforming to corresponding I.S.of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary and watering the surface for two days etc. complete. S.S.R.2021-22 Item No. 35.25
First Floor
Second Floor
Providing and applying two coats of synthetic enamel paint of approved colour to new/ old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. S.S.R.2021-22 Item No. 35.07
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 sqm /kg with two coats using Dr. Fixit or alike of chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. S.S.R.2021-22 Item No. 31.09
First Floor
Providing and laying Cast in situ/ Ready Mix cement concrete in M-25 of trap / quartzite /granite /gneiss metal for R.C.C. Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ). S.S.R.2021-22 Item No. 26.26
First Floor
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/bolted/welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete.
First Floor
Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) S.S.R.2021-22 Item No. 38.34
First Floor
Providing and fixing fibre glass reinforced polyster door shutter 30 mm. thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc. complete. S.S.R.2021-22 Item No. 39.58
First Floor
Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work) S.S.R.2021-22 Item No. 51.19
First Floor
Providing and fixing in position powder coated aluminium louvered windows/ ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. S.S.R.2021-22 Item No. 39.68
First Floor
Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter/ two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking joints and watering etc. complete. S.S.R.2021-22 Item No. 27.14
First Floor
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm. x 30 cm. and conforming to I.S.15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. S.S.R.2021-22 Item No. 33.67
First Floor
Providing and laying ceramic tiles having size 30 cm. x 30 cm. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. S.S.R.2021-22 Item No. 33.25
First Floor
Providing and fixing in position Gypsum board false ceiling with 12.5 milimetre thick Gypsum boards, screwed/ fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 milimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. S.S.R.2021-22 Item No. 38.51
First Floor
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. S.S.R.2021-22 Item No. 31.05
First Floor
Providing and fixing on walls /ceiling /floor 40 milimetre diameter CPVC pipe with necessary fittings, remaking good the demolished portion.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. S.S.R.2021-22 Item No. 42.59
First Floor
Providing and fixing on walls /ceiling /floor 15 milimetre diameter CPVC pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. S.S.R.2021-22 Item No. 42.55
First Floor
Providing and fixing 15 mm diameter screw down bib/stop tap of brass including necessary socket union nut complete. S.S.R.2021-22 Item No. 41.40
First Floor
Providing and fixing screw down for 40 mm diameter wheeled stop tap of brass including necessary sockets/union nut complete. S.S.R.2021-22 Item No. 41.47
First Floor
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/union nut etc. complete. S.S.R.2021-22 Item No. 42.83
First Floor
Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall, 100 mm diameter G.I. plug bend inlet pipe all fittings, cutting and making good walls, floors etc. complete. S.S.R.2021-22 Item No. 42.86
First Floor
Providing & fixing 15 mm diameter PVC Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc. complete. S.S.R.2021-22 Item No. 43.39
First Floor
Providing and fixing coloured glazed earthenware Wash Hand Basin of 55 cm x 40 cm including cold water piller tap/cold and hot water piller tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. S.S.R.2021-22 Item No. 41.66
First Floor
Providing and fixing 10centimetre cast iron Nahani Trap includingcast iron grating ,bend and piece of cast iron pipe upto the outside face of the wall complete. S.S.R.2021-22 Item No. 41.80
First Floor
Providing and fixing 15 cm x 10 m salt glazed stoneware gully trap in cement concrete 1:4:8 out side the building including cast iron grating in the sink, connecting glazed stonewre pipe brick masonry chamber with cast iron lid and cast iron grating for the gully trap. S.S.R.2021-22 Item No. 42.02
First Floor
Providing & constructing Brick Masonry Inspection Chamber 60 cm x 45 cm with R.C.C. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, Brick Masonry, plastering from inside and airtight 75 mm thick R.C.C. cover medium duty 100 kilogram etc. complete. S.S.R.2021-22 Item No. 42.16
First Floor
Providing, laying & fixing P.V.C. pipe of 110 mm. diameter with fittings such as bends, tees, reducers, clamps etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. S.S.R.2021-22 Item No. 42.28
First Floor
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity between 1000 to 20000 liters. S.S.R.2021-22 Item No. 42.54
First Floor
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.5 m) by Mechanical Means. S.S.R.2021-22 Item No. 21.10
Providing and laying in situ cement concrete M-20 with tremix treatment for 100 mm. thickness for flooring with groove cutting of 4 mm. wide and 20 mm. deep with necessary refilling with bitumen etc. complete. S.S.R.2021-22 Item No. 33.30
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 sqm /kg with two coats using Dr. Fixit or alike of chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. S.S.R.2021-22 Item No. 31.09
Providing fine cement finish 1.5 mm. thick over green plaster surface including scaffolding curing etc. complete.
Providing and fixing self supporting steel roofing system (Proflex) for a Godown or alike made up of structural grade steel sheet of 912 milimetre width ( tolerance + / - 2 milimetre ), moulded at site using mechanical press dies to the desired curve and shape to form 605 milimetre wide interlocking panels . The interlocking panels shall be pressed to close the seam forming water tight joints for a span of 21.30 metre having arch rise as 4.26 metre, arch length 25.13 metre.The base material made up of imported galvalume steel complying to ASTM A792 having base metal thickness of 1.00 milimetre ( tolerace + / - 0.02 milimetre ) with alloy coating AZ 150 and paint coating of regular modified polyster, top coat 25 micron and bottom coat 12 micron as per approved colour, including fixing hangers, clamps etc.as may be necessary of Proflex standard, including fixing sky light of 2 milimetre thick polycarbonate sheet of size 2 feet x 14 feet and turbo ventilator of 24 inch diametre to be installed at every 30 feet along the length of roof including finishing, testing and cleaning etc. complete. S.S.R.2021-22 Item No. 38.42
Dismantling the R.C.C. work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed. S.S.R.2021-22 Item No. 46.29
Removing doors and windows with frames and stacking the materials as directed with all leads, lifts, complete. S.S.R.2021-22 Item No. 46.15
Removing ventilators and small windows with frame and stacking the materials with all leads lifts, complete. S.S.R.2021-22 Item No. 46.16
Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts, complete. S.S.R.2021-22 Item No. 46.19
Removing Water Closet Pan including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed concrete around pan removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials out side etc. complete. S.S.R.2021-22 Item No. 46.41
Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to I.S. 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc. complete. S.S.R.2021-22 Item No. 33.61
Providing and laying vitrified matt finish tiles for Skirting having size 590 mm. to 605 mm. x to 605 mm. of 8 to 10 mm thickness and confirming I.S. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. S.S.R.2021-22 Item No. 33.43
Providing and laying Cast in situ/ Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade) S.S.R.2021-22 Item No. 26.19.
Providing and fixing black kadappa stone as shelves 25 mm. thick machine polished, extending the polish upto 20 cm. width on lowerside, rounding corners, laying in position jointing with bedding cement mortar 1:4 proportion curing etc. complete. S.S.R.2021-22 Item No. 33.23
Providing earth work in embankment with approved materials obtained from other sources upto lead of 50 metre including all lifts, laying in layers of 20 centimetre to 30 centimetre thickness breaking clods, dressing to the required lines, curves, grades and section, watering and compaction with vibratory roller with V-Sat attachment to achieve not less than 97% of standard proctor density etc. complete (Material obtained from Other sources). S.S.R.2021-22 Item No. 2.28
Providing and errecting chain link fencing 1.6 metre height with galvanised iron chain link of size 50 x 50 milimetre 8 guage thick and fixed 75 milimetre above Ground level on vertical Mild Steel Angle of 40x40x6 milimetre size including excavating pits for foundation and embeded in cement concrete block of 1:4:8 mix of size 450x450x670 milimetre at 1.75 metre center to center with iron bar 16 milimetre diameter as hold fast including welding link with angle frame at 30 cm. c/c nuts and bolts and horizontal Mild Steel Angles at top and bottom of 25x25x5 metre size and vertical Mild Steel flat 35 x 5 metre and 25 x 5 metre horizontal including cross support of 40x40x6 metre Angles both sides at every corner or bends embeded in concrete blocks of 1:4:8 of size 450x450x670 milimetre including 3 coats of oil painting etc. complete. S.S.R.2021-22 Item No. 46.39
Providing and laying Weep Holes of 100 mm diameter AC/ PVC pipes as per drawing for abutment returns, return walls etc. Complete. S.S.R.2021-22 Item No. 17.37
Carting of excavated earth from site up to 2 km distance as directed by Architect S.S.R.2021-22 Item No. 2.28
Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5 to 3.0 m.) by Mechanical Means. S.S.R.2021-22 Item No. 21.08
Filling in plinth and floors with approved excavated material in 15cm.to 20cm. layers including watering and compacting etc. complete. Spec. No Bd.A.10 Page No. 262 (S. S. R. I. No. 21.36 & P. No. 191)
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversibleDrum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) ) Spec. No. Bd. E. 1 Page No287, (S. S. R. I. No. 24.01 & P. No. 226)
Providing Internal Cement Plaster 12mm Thick In Single Coat In Cement Mortar 1:4 Without Neeru Finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complet. Spec. No. Bd.L. 2 Page No. 368 (S. S. R. I. No. 32.04 & Page No. 268)
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete. Spec. No. Bd.V.43 Page No.574. (S. S. R. I. No. 42.17 & Page No. 353 )
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. Spec. No. Bd.C.2 Page No. 275 , (S. S. R. I. No. 23.01 & Page No. 223 )
Providing and laying concrete pipes of I.S. NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.. Spec. No. Bd.V.41, Page No. 573 (S. S. R. I. No. 42.07 & Page No. 351)
RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge (S. S. R. I. No. 48.46 & Page No. 405)
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (S. S. R. I. No. 42.85 & Page No. 355)
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (S. S. R. I. No. 42.87 & Page No. 355)
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5"diax25m deep bore well at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrappe d around with netlon mesh including 300mm thick side filling around out side of RCC rings (annular space)with 40 mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fineaggregate (naturalsand/crushedsandVSIgradefinelywashed etc.) including netlon mesh between each gravel /fineaggregate (naturalsand/crushedsandVSIgradefinelywashed etc.) medialayer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement forinlet & outlet pipe excavation & back filling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage,scaffolding,transportation,taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing ,technical specification and direction of the Engineer in charge.
Boring/drilling bore well of 300mm dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well-casing pipe of 150mm dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer in charge. (S. S. R. I. No. 48.49 & Page No. )
Excavation for foundation in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 m. beyond the building area and stacking or spreading as directed, preparing the bed for the foundation and necessary back filling, ramming, watering, including shoring and strutting as necessary complete. Lift 1.5 M to 3.0 M depth
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand V
Providing and applying washable oil bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces (excluding the primer coat) complete.
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. (S.S.R.2018-19 Item No 32.26 additional spec no. As directed by Engineer in Charge:
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
Providing and laying chequered tiles ofapproved qualityof size 30cmx30cm, confirming to corresponding I.S.forflooring in required position laid on a bed of1:4 cement mortar including cement float,filling joint with cement slurry cleaning curing etc. compl
Providing and laying vitrified mirror/glossy finish tile s having size 590mmto605mmx590mm to 605mm of 8to10mm thickness and confirming to IS.15622-2006 (groupBla) of approved make,shade and pattern fordadoandskirting inrequired position fixed in 1:4 cemen
Providing and fixing green marble of 18 to 20 mm thick for doorframe/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etc. complete.
Providing and Fixing 30MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size19x19mm for styles and15x15mm for the top and bottom rails, M.S frames hall have acoatofmetelprimer of approved make and manufacture. M.S frame shall be covered withheatmouledPVC'C'channelmadefrom 5mm (+/0.25)thick prelaminated sheet of density 600kg/cbm, ofsize30mm thickness 70mm widthout of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side for mingstiles;and 5mm thick,95 mm wide PVCsheet out of which 75mm shall be faltand 20mm shall be tapered in 45 on the inner side to form top and bottom railand 115mm wide PVC sheet out of which 75mm shall be faltand 20mm shall be tapered on both sides toform lockrail.Top, bottom and lockrailshall be provide deithersideofthepanel.Anadditional5mm(+/0.25)thickPVCstripof20mmwidthistobestuckonthebottomsideofthe'c'channelprelaminatedpanelingof5mm(+/0.25)thickPVCsheettobefittedinsidetheM.S.framewelded/sealedtothestylesandrailswith5mm(+/0.25)x30mmPVCsheetbeadingoneithersideandjoinedtogetherwithsolventcementadhesiveetc,10mmthickness(5mm(+/0.25)x2nos)20mmwidecrossPVCsheetasgapinsertfortherailandbottomrail.Doortobefixedtoframeswith3nosM.S.powdercoatedbuthingesofsize100mmx25MMx2mmusing32mmlongsteelscrewsdrilledsuitabletopassthroughboththewallsoftheM.Stube.Otherhardwaresshouldbefixedwith19x6mmsizesteelscrewsincludingfixturefasting.Complete as per direction of engineer in charge.
Providing and fixing 450mmx550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top, 40mm diameter and 1.5mm thick vertical supports spacedat 1.5 mcenter to center and 8mm thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding ,finishing,buffing to stainless steelpipeetc. complete
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets / union nut etc. complete. Spec. No. As Directed By Engineer In Charge.
Providing and fixing on Walls / Ceiling / Floor 25 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge
Providing and fixing on Walls / Ceiling / Floor 32 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge
Providing and fixing on Walls / Ceiling / Floor 50 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge.
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge.
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete chanels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75 kg with lid and frame fixed in cement concrete
Executive's Table @ 1800Lx900Dx750HT Providing & Fixing of Table @1800Lx900Dx750HT-TOP & GABLE END to be made of Membrane finish with softwater fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawing P. No.301 Item No. 51.21
Providing & Arrangemnt of High Back Chair tilt mechanism with multilocking, high density cusion on seat composite leather with metallic silver finish base and arms with P.U. castors gaslift for height adjustment., P. No.305 Item No. 51.41
Providing & Arrangemnt of Mid Back chair, ECOCTS Mechanism, Fixed Armrest, Gaslift for Seat height adjustment, Standard 5-prongP/Nylon Base with Fabric Upholstery., P. No.305 Item No. 51.43
Providing & Fixing Curviliner Workstation @1500/1500Lx600/600Dx750HT, Curvilinear Table Top @1500/1500Lx600/600D:-TOP to be made of 25mm thick Prelaminated particle board with PVC edge band, GABLEEND tobe made of 25mm thick Prelaminated particle board with PVC edgeband, KEYBOARD TRAY (WITH OUT MOUSE TRAY):-Metal Powder Coated-Black Color, CPU TROLLEY:- Metal Powder Coated-Black Color, along with 3 DRAWER PEDESTAL UNIT having overall size 392Lx450Dx680Ht.mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18mm prelaminated particle board. P. No.303 Item No. 51.30
Free Standing Table @ 1500Lx600Dx750HT Providing and fixing Table of Size 1500x600x750mm. Top:made from 25mm Prelaminated Particle board. All edges are covered by 2mm. Thk. PVC edge bands glued by hotmelt glue applied by auto edge banding machine. Legs: C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel: Made from 18mm both side prelaminated particle boards. All edges are covered by 0.8mm PVC edge bands glued by hotmelt glue applied by auto edge banding machine. KEYBOARD TRAY (WITH OUT MOUSE TRAY):-Metal Powder Coated-Black Color,CPU TROLLEY:- Metal Powder Coated-Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392Lx450Dx680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, P. No.302 Item No. 51.26
Conference Table @ 1800 x 900 x 750 mm Ht. Providing & Fixing of MainTable @1800Lx900Dx750HT- made up of 18+18mm Thick MDF top with PVC Membrane finish and water fall edge profile. Aluminium Anodizied finish beeding of 4mm thick is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in PVC Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from in side for the provision of passing electrical and Datawiring., MODESTY PANEL:- to be made of 18mm thick Prelaminated particle board with PVC edge band. Access Flap:- For Wire manager 1 Nos. P. No.304 Item No. 51.32
Medium Height Steel Storage @ 750Lx450Dx1200HT Providing and fixing Openable Steel Storage of 750x450x1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns. with 25 mm. thk. as per drawing. P. No.304 Item No. 51.36
Garden soils :- Supplying one side fresh garden soil well sieved 90% to pass through IS sieve of 10 mm size free from stone rubbish like dried grass root & other such materials the soil should be fresh from quarry. The colour of the soil generally be red. The soil will be measured by measuring box. (Item include Royalty charges. Corporation types transporting loading Unloading etc. complete. Horticulture DSR 1/2
Suplying & laying well quality of manuar required for small, large tress including mixing with soil , watering, transportation at site etc. completed Horticulture DSR 2/2
Saplings of flowering/shadytrces Gulmohar, Raintree, Peltophorum etc (one year old) Horticulture DSR 8/3
Saplings of Small & medium Ornamental flowering plants , Thuja,Cupresus plants ornamental Ficus, Mussanda etc. Horticulture DSR 9/3
Rose Plant :- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the fresh garden soil in minor in 3:1 proportion to a required height of 0.3 meter mixing the soil & minor levelling, watering on previous night. Planting 40 to 50 cm height healthy plant of required rose verity mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. Horticulture DSR 9/5
Mogra Plant/Creepers/Climbers:- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 15 cm. & ramming height of 15 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year old) healthy plant as per specification mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. Horticulture DSR 10/6
Planting large flowering/shady trees:- Digging pit with size 0.9 x 0.9 x 0.9 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 30 cm. & ramming height of 60 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year old) healthy trees sapling as per specification mainaining till well established by watering weeding, sturring of soil replacing of casualities etc. complete. Horticulture DSR 12/6
Planting small & medium size ornamental flowering plant:-Digging pit with size 0.6 x 0.6 x 0.6 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit with fresh garden soil & farm yard minor upto a height of 0.6 meter in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year or two year old) healthy plant sapling as per specification mainaining till well established by watering, weeding, sturring of soil replacing of casualities etc. complete. Horticulture DSR 11/6
Preparing instant Lawn :- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a height of 20 cm. mixing soil & minor throughly well levelling with required slope light watering on previous night, rolling on surface. Fixed readymade lawn truf rolls or slab of reqired verity as directed. ramming on it for proper fixing & mainaining till well establish by watering, weeding, clipping or moving etc. complete. Horticulture DSR 3/4
Preparing Edging or border:- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a required height of 20 cm. mixing , levelling , watering the same planting suitable verity of edging plants & rooted cutting at distance of 15 cm. between plants to plants and row to row watering & maintaining till well grown to te stage of prunning Horticulture DSR 4/4
Preparing Shrubbery:- Excavating the ground to a required depth of 30 cm. removing & conveying unwanted stuff to a required distance as directed. Providing and filling fresh garden required distance as directed. Providing and filling fresh garden soil and manure in excavated area in 3:1 proportion to a required height of 30 cm. Mixing , levelling , watering on previous night. Planting well rooted shrubs 0.5 mtrs. apart as directed and maintaining till well established by watering, weeding, strring replacing of casualties etc. complete. Horticulture DSR 8/5
Dustbin 240 Litre Blue WB-240 Dimensions : 725 x 580 x 1075 mm ( 107x72x58cm ) Heavy Duty Sunproof Waste Garbage Bins Wheeled Bins Easy to maintain & Use Envirnoment Friendly Long Lasting Capacity : 240 Litre (Non SSR)
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means, S. S. R. I. No. 21.14 & P. No. 188
Disposing of dismantling materials of R.C.C. stone/ brick masonry / derbies, excavated material etc from work site beyond the 5 km Spec. No.:As directed by Engineer in charge etc. complete. (Beed District D.S.R, Page No. 125, Sr. No. 486)
Providing and fixing in position,Double shuttered aluminium extruded powder coated openable door of specified size with aluminium doorframe of powder coated section101.60x44.75m,3.18mmthik and shutter comprising of powder coated section having bottom and lock railofsize150mmx44.5mmx3.00mmthicktoprails47.62x44.45mmx.00mmthick,verticalstyle47.62x44.45mm,3.00mmthickandforshutterplainglasspanes5mmthickfortoppanelsand12mmthickbothsidelaminatedphenolbondedparticleboardpanelsforbottopanelsetc.,I.S.I.mark,heavyduty,Hydraulicfloorspringof150kgcapacity,havingheavydutyconcealedlock,necessarybeading,glazingclips,PVCgaskets,250mmlengthaluminiumtowerbolts,150mmdia.padhandle,etc.asperdetaileddesignanddrawingorasdirectedbyengineerinchargeincludingallmaterials,labours,and equipment etc.complete
Providing and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 – 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutter
Medium Height Partition @ 1800/1200HTTILEBASEDPARTITIONSYSTEM:-TilebasedAluminumpartitionsystemof1800/1200mmht.madeof60mmthkaluminumframeshavingtwoseparateracewaysforlayingelectrical&computerwiring.Thewiremanagementshallbethroughtotheracewaytobefittedatbottomofpartitionandotherimmediatelybelowofworktopwithhookontyperacewaycoverforeasyaccessofwires.FramestobejoinedbyaluminumconnectorswithM6x16pan-headmachinscrewandwasherwithaluminumpostcover.Postcoverofsnaponfashiontobeconnectedonaluminumconnectors.Allvisiblealuminiumtobeinanodizedfinish.Thetop/exposedsidesoftheframeandpostsshouldbecoveredwithhorizontal/VerticaltrimandcapsmadeofAluminuminanodizedfinishinordertoenhanceitslook.UppertilesofpartitiontobeinSoftBoardorMarkertileof9mm.thk.,andprelaminatedparticalboardlowertilesinlaminatefinishof9mm.thk.on both the sides.
Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht.Providing and fixing Multiple Compartment Lockers @1140Lx457Dx1830mm. Ht.with12 Compartments ,Completebody & shutter made of CRCA Sheet with powder coated finish as per approved color.
Inspection kit
Providing &Arrangemnt of MIdBack,Normal Syncro Mechanism,FixedArmrest,Gas lift for Seat height adjustment,Standard5-prong/Nylon Base with Leather Upholstery
Foot operated sink units with sope dispensor single person use Size: 400x380x845mm + 2% Material: SS 304 Bowl Shape: Round Feature: Without Faucet No. of holes: One Thkness: Minimum 1.0 mm Splash Back Height: 45 mm + 10% Surface Treatment: Brushed Sink Style: Single Bowl Finish: Mirror Polished
Hand Sanitizer Dispensor (Automatic/Hands Free) -Easy touchless operation with on and off button -Chrome and black with clear liquid chamber that stores up to 16.5 ounces of liquid content including soap or hand sanitizer -Amount of liquid dispensed can be adjusted -Touchless dispenser should sit on the countertop or mount to the wall -AA batteries operated for operating touchless dispenser
Hand dryer -Material: ABS Plastic -Power: 2200 watts -Water Splash Proof: IP X 1 -Voltage: 220 V -Frequency: 50Hz-60Hz -Air Speed: 16M/S -7-12s fast drying hands
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal use, scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes). 10-2-27
Providing printed instruction chart
Provided pair of duly tested rubber hand gloves as per IS :340715 suitable for working on 22kV supply. 10-2-23
Inspection Tables with tubelights - M.O.C.: S.S. 304 - Length X Width: 1.2m X 0.76m x 0.76m - Support Str.: S.S. 304 -Thickness: minimum 2 mm; -Buffing: Mirror Finish - LED Tubelight 22 W to be fitted with SS structure -No. of legs: 6 made of 30 x 30 x 1.6 mm square tubes with rubber packing.
Laboratory Equipments for pack house: A. EQUIPMENTS 1. Illuminated magnifier (Magnoscope) 20 X 2No* (Indian make) 2. Stereo binocular microscope with cold light source with 3MP camera 1No (Indian Make) 3. Inspection Table clear white top (steel make 2.5’X6’) 2 No* 4. Desktop Computer with internet 1No 5. Printer (24 Pin dot matrix) 1No 6. UPS for computer with sufficient power back up 1No B. INSPECTION KIT 1. Kit bag 1No.; 2. Knife (pointed) 2 No.; 3. Magnifier glass- 20 X with provision of light 2No.; 4. Camel brush 2No.; 5. Scissor 2No.; B146+B15. Torch with cell 2No.; 7. Forceps 2No.; 8. Marker pen- (Red & Black) 2No.; 9. Pencil &Sharpener 2No.; 10. Stapler With pin 1No.; 11. Cello tape- 1No.; 12. Rexene sheet- 1No.; 13. Marking slip- 50 No.; 14. Specimen vials - 20 No.; 15. Poly bags- 20No.; 16. Needle- 1No.; 17. Calculator- 1No.; 18. Hand Gloves- 30 pairs; 19. White enameled Tray (solid type) 4 Nos; 20. Apron 30 No.
Weigh Balance (digital), 150 kg; ISI Marked Electronic Weighing Scale (Platform Scale) 1. Capacity: 150 kg 2. Accuracy: 20 g 3. Platter Size: 550 mm x 650 mm (Tolerance+/- 10 %), stainless steel made. 4. The body of the scale should be sturdy. 5. The Weighing Scale should have adequate Body Base Dimensions to maintain secure balance at the time of weighing. The Electronic weighing Scale (Platform Scale) should incorporate following features for user-friendly convenience: 1. Display: LED display with 5 digit, Size: Minimum height 14 mm 2. TARE function 3. The scale should have LED indications for A.C. On, Nett/Gross Weight, Zero, Battery, Battery Low. 4. The scale should have Memory Accumulation feature. 5. The Scale should have inbuilt rechargeable battery back up for minimum of 8 hrs. 6. Display Intensity should be adjustable, through keyboard, while operating on Battery for longer Battery back up. Make: Essae / Avery / Equivalent
Weigh Balance (digital), 60 kg; ISI Marked Electronic Weighing Scale (Platform Scale) 1. Capacity: 60 kg 2. Accuracy: 2 g 3. Platter Size: 360 mm x 276 mm (Tolerance+/- 10 %), stainless steel made. 4. The body of the scale should be sturdy. 5. The Weighing Scale should have adequate Body Base Dimensions to maintain secure balance at the time of weighing. The Electronic weighing Scale (Platform Scale) should incorporate following features for user-friendly convenience: 1. Display: LED display with 5 digit, Size: Minimum height 14 mm 2. TARE function 3. The scale should have LED indications for A.C. On, Nett/Gross Weight, Zero, Battery, Battery Low. 4. The scale should have Memory Accumulation feature. 5. The Scale should have inbuilt rechargeable battery back up for minimum of 8 hrs. 6. Display Intensity should be adjustable, through keyboard, while operating on Battery for longer Battery back up. Make: Essae / Avery / Equivalent
Weigh Balance (digital), 6 kg; ISI Marked Electronic Weighing Scale (Table Top) 1. Capacity: 6 kg 2. Accuracy: 1 g 3. Platter Size: 205 mm x 250 mm (Tolerance+/- 10 %), stainless steel made. 4. The body of the scale should be sturdy. 5. The Weighing Scale should have adequate Body Base Dimensions to maintain secure balance at the time of weighing. The Electronic weighing Scale (Table-Top) should incorporate following features for user-friendly convenience: 1. Display: LED display with 5 digit, Size: Minimum height 14 mm 2. TARE function 3. The scale should have LED indications for A.C. On, Nett/Gross Weight, Zero, Battery, Battery Low. 4. The scale should have Memory Accumulation feature. 5. The Scale should have inbuilt rechargeable battery back up for minimum of 8 hrs. 6. Display Intensity should be adjustable, through keyboard, while operating on Battery for longer Battery back up. Make: Essae / Avery / Equivalent
Covid-19 Health and safety: Providing and making necessary arrangements of various essential materials and items of recommended quality and make as per guidelines of the health department required for prevention of COVID-19 pandemic in consideration of health and safety management of man power at construction site 1. Hand Sanitizer.: 50 liters 2. Disinfectant. : 30 Liters 3. Sodium Hypochlorite. : 30 KG 4. Fogging machine and Liquid for sanitization.: 1 Number 5. 3 Ply Face Mask of good quality. : 500 Numbers 6. Surgical / Latex Gloves of good quality.: 200 Pairs 7. Rubber Gloves of good quality.: 100 Pairs 8. Empty Spray Bottles 100 ml (Plastic).: 20 Numbers 9. Empty Spray Bottles 1000 ml (Plastic).: 5 Numbers 10. PPE kits. : 10 Numbers 10. Temperature Guns. : 3 Numbers 11. Face shield : 30 Numbers
Electromechanical work
PART-1: THERMAL INSULATION WORK
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-80 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-100 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-60 mm thick PIR panels, Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside.
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-100 mm thick PIR panels, Density: 40 ±2kg /m3 , 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside. Additional PIR filled hat section of minimum 50 mm thicnkess beyond any metal member of the support should be considered if only metal 'T' is being considered for ceiling panel support.
INSULATED FLOOR Supply and Erection as per General Technical Specifications Floor 100 mm XPS , min 30 kg/cu.m density. Rate for floor insulation to include supply and erection of all ancilliaries including polythene vapour barrier & two ply tarfelt as per specifications and bituminous primer, bitumin / bituminous cold compound for proper adhesion to surfaces.
Supply & Fixing of 6~9 mm thick EPDM / Nitrile rubber on RCC slab / brick walls with suitable CPRX compound adhesive over which the insulated panels shall be fixed tightly with Nylon / FRP / Steel reinforced Nylon bolts.The bolt heads on the panels shall be covered with hat runners filled with PUF insulation as per standard practice.
Supply & fixing of of Al foil min. 50 micron on RCC slab / brick walls with suitable CPRX compound adhesive / bitumen
Ancillary Materials and Services - Flashings for Internal and external wall-ceiling joints and wall-wall joints as applicable or as may be required for doors or other openings. The layout showing the chamber dimensions and height is enclosed for ready reference. The flashings should be atleast 50mm x 50 mm or larger sizes with adequate overlap over any given panel-panel joint (Precoated G.S. Sheet, minimum 0.5 mm thick)
Ancillary Materials and Services - Silicon / Polyeurathene sealant for sealing the gaps between panels and the external / internal face of the insulation panels and any other location as may be deemed suitable for proper insulation panel erection system as applicable.
Ancillary Materials and Services - PUF/PIR chemical, adhesives,/ tapes / plastic caps etc reqd for onsite application, as may be necessary for a complete and foolproof insulation job.
Ancillary Materials and Services -SITC of Pressure relief ports suitable for mounting on insulated panels of various thicknesses (60 mm to 100 mm) with internal heaters for room temperatures ranging from 25 deg C to (-) 10 deg C. (Fermond Soupape 2220 -Valve /Equivalent)- 1 no for each cold storage chamber.
Ancillary Materials and Services - Making & finishing of cut outs for doors, pipes, cables, pressure ports etc as per requirement at site. Finishing would include filling with PUF/PIR & PUF/PIR foam of required density and covering with pre - coated G.I.sheet from both side of the panels to give aesthetically neat joint acceptable to Consultants / Owners. This should also include any additional Silicon sealent or any other material as required.
Precooling Chamber1,2, Staging cold room 1,2 Manual Sliding type 1500 mm x 2600 mm ht x 100 mm thick PIR , manual type Providing & fixing of Insulated sliding doors (suitable for fitting on panel structure) of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manual single leaf sliding with 0.6 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame. The door leaf shall have 0.5 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel wall to be included in the cost. The sliding mechanism should be sturdy and smooth in operation complete with rail, runners, sill on the bottom etc. Rail shall be made of heavy duty aluminium alloy / SS with 45º drop & with polyethylene roller / special grade nylon arrangement runner system. The rail shall be provided with canopy / cover of 1.2 mm thick PCGI / Extruded Aluminium of required thickness. The doors shall have easily replaceable EPDM gaskets to ensure perfect hermetic sealing .
For Paaasage Area Insulated Doors -Swing type with double shutter 2000 mm x 2600 mm ht x 60 mm thick PIR Providing & fixing of Insulated doors (suitable for fitting on panel /brick wall structure) mounting of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manually operated double leaf swing type with 1.25 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame.Any other material for door frame may be considered on case to case basis. The door leaf shall have 0.6 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 42 ± 2 Kg/m3 (insulation thicknesses as mentioned).Viewing window on each door leaf shall be provided. The rate shall include all minor accessories not specifically mentioned in the technical specification, but essential for the completeness of the work.
DOCK DOOR & SHELTER Dock door shall be vertically moving with motorized movement. The shutter shall have PUF core with aluminum external / internal facing with white paint (RAL9003E/Eqvt). The vertical moving track shall be U shaped made of 2.5 mm G.S. Sheets. Full perimeters doors seal with PUF verticals, Vinyl lintel seal & rubber seal of bottom shall be provided. acceptable makes: Gandhi Automation/ Metaflex/Infraca/eqvt (a) Dock door motorised type (b) Dock door motorized complete with control control button, manual lock release & cabling. DOCK DOOR: Type:motorised type Door opening Size : 2400 width x 2700 mm height Insulation : 40 mm PUF Door Movement : upwards, then curving into the ceiling Facing : External : Aluminium painted white Internal : Paint for higher impactability Operator : Normal Viewing Window: 1 no DOCK SHELTER : Retractable type suitable for heavy duty operations for door opening size as above. Dock seal to have adjustable top vertical member so as to adjust for container height variations
DOCK LEVELER Designed for Hydraulic operation as per General technical specification ,Acceptable makes: Gandhi Automation/ Metaflex/Infraca/eqvt Size : 2000mm width and 2500mm deep, lift height min 300 mm from centre level, upwards & downwards., main cylinders-2 nos, All controls, control panels, controllers, power and control cabling etc as required for full operation to be included
SITC of strip curtains made of 3 mm thick transparent PVC sheet strips with 40 / 50 mm overlapping and supporting clamps. The strips shall have free swinging motion. The strip material shall be suitable for the specified low temperature application to ensure that it remains soft even at the lowest operating temperature
Precooling Chamber 1,2, Staging cold room 1,2 Suitable for Clear opening Size: 1500mm X 2600mm ht
For Passage Area Suitable for Clear opening Size: 2000mm X 2600mm ht
For Ante-Room Area Suitable for Clear opening size: 2000 mm x 2100 mm ht
PART-3: Refrigeration System for Pre-cooling chamber, Staging cold rooms, ante-room and Dock Area
AIR COOLED CONDENSING UNITS For Pre-Cooling chamber 1,2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For Pre-Cooling chamber 1,2 ( 2 nos for each ACU): Capacity: 26 KW DesignTemperature: (-)4 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included There shall be provision to run each condensing unit separately especially in cases where product qty is low. Related controls (PLC if needed), cabling, control panel, etc shall be included in the cost. This shoud be possible in Automode as well as manual mode.
AIR COOLED CONDENSING UNITS For staging cold room 1,2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For staging cold room 1,2 Capacity: 13 KW DesignTemperature: (-)4 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included
AIR COOLED CONDENSING UNITS For Passage Area (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R513A / R450A or other approved HFO, Air cooled condenser, Liquid receiver, Base frame for mounting, H.P. / L.P. cut outs and pressure gauges etc. Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For Dock Area Capacity: 12.5 KW DesignTemperature: 10 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included
AIR COOLING UNITS - Air Cooling Units for Pre-cooling chamber 1,2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Twin coil type,Type of Refrigerant feed: HFO - DX Capacity - kW: 51, Evap. Temp. & TD ‘C’: (-)4 °C / 4 °C Coil / Fin MOC: Cu / Al, Fin spacing -mm: 6 mm Fin type: Plate, Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 52500, External sp. Wg, mm: 25 No of Fans/Unit: 3/4, Fan Motor -kW each: To be Mentioned Air throw -m: 8 m, Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: off cycle (provision to be kept for adding electrical defrost at later stage) Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well. Product Covering Flap - Suitable product covering flap made of PVC sheet / EQVT sturdy material to be mounted on the unit above the fan(s) to ensure proper air flow through the produce. There shall be suitable reinforcement inside the flap as well as at the ends for supporting the Flap. Costing for the same also shall be included. It must be noted that this scheme is considered as a part of a combined pre-cooling system which will have an airtight plenum created between the wall panel and the area around the ACU as defined above. So while the insulated panel will be billed as per the the insulation panel rates, the cutting for the panel, the flashings, etc as needed for the pre-cooling unit arrangement should be considered while quoting the cost of panels.
AIR COOLING UNITS - Air Cooling Units for Staging cold room 1,2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Single coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 13 Evap. Temp. & TD ‘C’: (-)4 °C / 4 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 6 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 15000 External sp. Wg, mm: 5 No of Fans/Unit: 2/3 Fan Motor -kW each: To be Mentioned Air throw -m: 8 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: Electrical Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.
AIR COOLING UNITS - Air Cooling Units for For Dock Area (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Single coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 12.5 Evap. Temp. & TD ‘C’: 10 °C / 10 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 4 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 6600 External sp. Wg, mm: 7 No of Fans/Unit: 2/3 Fan Motor -kW each: To be Mentioned Air throw -m: 20 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: offcycle Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level to be considered in the costing as well.
Refrigeration Piping, Fittings & Valves (General details as per PART – II- REFRIGERATION SYSTEM of GTS) The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same. The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation. Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.
Suction line insulation (General details as per PART – II- REFRIGERATION SYSTEM of GTS) Suction line insulation with EPDM/ XLPE/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC+weatherproof coating/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulton protection. Thickness - 25mm Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support. This is essentially ensuring that the insulation compression at the support is at the minimum.
Drain piping with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation
Controls and Instruments (a) Thermostatic expansion valves for each ACUs (b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature indicator (minus 20 to 50 deg. C range), for A.C. units to be placed outside the each cold rooms in ante-room area. (e) Digital RH indicator (0 to 100 % range) for A.C. units to be placed outside the each cold rooms in ante-room area. Only for pre-cooling ,staging cold room ACUs
First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant.
Painting of equipment/piping / piping supports etc. as per standard colour codes with initial coat of red oxide primer and two coats of synthetic enamel paint .
Humidification system for pre-cooling chambers complete with Industrial type Ultrasonic Humidifier, U-PVC water piping from the tanks to humidifier unit, fitting ,valves, atomizer nozzles (if requird), solenoid valves with strainers and humidistats etc. as may be required to maintain the relative humidity in the design range for Pre-Cooling Chambers. Also consider heavy duty PVC piping for air delivery into the cooling area for a release of humidified air into the main air stream, at atleast 1 m distance from the partition panel Humidifier Capacity: 12 Lit/hr.
Miscellaneous Items a) Vibration isolators for condensing units, supporting rods / Frame for A.C. Units with insulation, steel structure for mouting condensing units etc. as may be required b) Minor structural openings in walls / panels etc for piping, cabling etc. and finishing. c) 2000 lit water tank along with water pump as necessary for lifting water to the tank or lifting water from the tank depending on tank location ,UPVC piping, fittings,valves etc as may be required for condenser inlet air-precooling system. Condenser air pre-cooling system shall have automatic operation with water line sonenoid valves for each individual condensing unit and there shall be an interlock with the conensing unit start/stop as well as the ambiend air temperature wherein the air precooling system starts only after the ambient air temperature crosses 33 deg C and switches off when ambient goes beloe 33 deg C.
Charges for Installation, Testing and Commissioning Installation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
PART-4:Electrification work
Supply, Installation, Testing & Commissioning of earthing station using pipe in pipe earthing electrode with complete system as per specs. Including boring, civil work, chamber etc. Earthing shall be carried out as described in IS-3043-1960 code. Pipe in pipe earthing electrode system shall be as per enclosed technical specifications. The entire earthing system should be executed as per system supplier’s instructions. The Earthing Chamber with all the necessary material required for earthing shall be in Contractors scope. Testing of the Earthing system shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. 2 meters Length Earthing Electrode
Same as above but electrode length shall be 3 mts.
Supply & Installation of 32 x 6 mm Galvanized Iron earthing strip & Conductor shall be of High Conductivity. All Necessary Accessories required for installation of Earthing Strips such as Porcelain Insulators, Clamps, Saddles, Hardware, etc will be included in the rate. The Earthing strips connections shall be used as per the provided earthing schedule.
Same as above with Earthing strip of 25 x 3 mm Copper.
Supply & Installation of 6" dia RCC half round pipe for covering HT/LT cables. Rate shall be inclusive of excavation, back filling and civil work for chambers.
Supply & Installation of 6" dia RCC round pipe for HT/LT XLPE cables laid for Road Crossing. Rate shall be inclusive of excavation, back filling and civil work for chambers.
Supply & Installation of 146/150MM dia round HDPE Pipe for LT cables. Rate shall be inclusive of excavation, back filling and civil work for chambers.
Supply & Installation of 50MM dia round HDPE Pipe for LT cables. Rate shall be inclusive of excavation, back filling and civil work for chambers.
Liaisoning Work with Electricity board & Electrical inspector or any other government authority for change of sanction & Contract load as per new requirement of electrical load. Job involves preparation of necessary documents with drawings, as required for load application, submission of document files with necessary officials / departments, follow-up with all concerned departments for getting required load sanctioned. Obtaining work completion report from Electrical inspector & board officials. Client (Owner) will make all official payments as per the requirement of Electricity board.
Supply & Installation of printed Danger Board/instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Supplying and erecting wall hook 225mm projection for keeping fire buckets made out of 15 mm dia. M.S. Rod grouted in wall to a depth of minimum 15cms complete.
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 & CPRI tested having 2 mm thickness upto 3.3 kV
Supplying and erecting D.C.P. type fire extinguisher 6 kg capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets conforming to IS 2171-1985/ IS 15683 and complete erected with necessary clamps made from 50x6 mm M.S. flat with nuts & bolts grouted in wall complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
Supply, Installation, Testing & Commissioning of 3.5 C x 300 sq.mm, 1.1 KV grade, Stranded aluminium conductor, XLPE insulated, armoured, PVC outer sheathed cables conforming to IS:7098 ( Part-I ). The rates shall be inclusive of laying of cable in provided Trench/Pipe/Cable Tray. Termination of cables using double compression gland, crimping type lugs, etc. Each termination shall include supply of all necessary components, accessories, including double compression cable gland, cable lugs (crimping type) and consumables to make a complete termination in such a way that no live parts of the terminal and connecting lugs are exposed. While making termination, all other protection arrangement shall also be ensured. The cable tagging with proper ferrules shall be supplied & installed by the Contractor as part of cable termination work. Testing of the cables shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. Before Commissioning of cables Contractor need to check for physical damages & proper connection of all the terminals.
Same as above but with 3.5 C x 185 sq. mm. Stranded Aluminium Conductor.
Same as above but with 3.5 C x 50 sq. mm. Stranded Aluminium Conductor.
Same as above but with 4.0 C x 6 sq. mm. Copper multi stranded.
Same as above but with 4.0 C x 4 sq. mm. Copper multi stranded.
Same as above but with 3.0 C x 6 sq. mm. Copper multi stranded.
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.
Same as above but with 2.0 C x 2.5 sq. mm. Copper multi stranded.
Supply & Installation of 4.0 C x 6 sq. mm 1.1 KV grade, Multi Stranded Copper conductor, PVC insulated, PVC outer sheathed cables conforming to IS:694 (1990). The rates shall be inclusive of laying of cable in provided Trench/Pipe/Conduit/Cable Tray. Testing of the cables shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. Before Commissioning of cables Contractor need to check for physical damages & proper connection of all the terminals.
Same as above but with 4.0 C x 4.0 sq. mm. Copper multi stranded.
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.
Termination of 4.0 C x 6 sq. mm, LT copper flexible cables using PVC cable gland of IP65, crimping type Copper lugs, etc. Each termination shall include supply of all necessary components, accessories, including PVC cable gland, cable lugs (crimping type) and consumables to make a complete termination in such a way that no live parts of the terminal and connecting lugs are exposed. While making termination, all other protection arrangement shall also be ensured. The cable tagging with proper ferrules shall be supplied & installed by the Contractor as part of cable termination work.
Same as above but with 4.0 C x 4.0 sq. mm. Copper multi stranded.
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.
Supply & Installation of 300 x 75 mm, Perforated type cable trays made out of 16 G CRCA sheet & Hot Dipped galvanized, with support at every 1.5 mt. interval using M.S. angle of size 40x40x5 mm Or Using Suspension GI rods. M.S. Support shall be painted with two coats of red oxide primer & two coats of silver paint. All necessary accessories required for installation of cable trays such as Cable Tray Supports, Clamps, Flat Strips, Joints, Hardware, etc shall be included in Installation rate.
Same as above but of size 200 x 75 mm.
Supply & Installation of 300 x 20 mm, cable tray cover made out of 18 G CRCA sheet & Hot Dipped galvanized, with all necessary accessories required for installation of cable tray covers such as Clamps, Flat Strips, Joints, Hardware, etc shall be included in Installation rate.
Same as above but of size 200 x 40/50 mm.
Supply, Installation, Testing & Commissioning of conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on 5 meters height, The Lightning protection includes the Lightning counter comprising of digital display in an IP 67 enclosure with the minimum sensitivity of 1500A & maximum capacity of 220 KA counter & it should be tested as per IS/IEC, The Job also includes supporting mast using Galvanized Iron pipe of 3 meter length plus 2 meter pipe of FRP complete with base plate, Guy rope wires, Insulator, Clamps, Fasteners, Fan Hooks, hardware, etc.
Supply, Installation, Testing & Commissioning of Primary light point wiring with 1.5 sq.mm. PVC insulated FRLS multistranded copper conductor wires, through PVC conduit concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch, with concealed/surface box, modular surface plate, ceiling rose/holder etc.
Supply, Installation, Testing & Commissioning of Secondary light point wiring with 1.5 sq.mm. PVC insulated FRLS multistranded copper conductor wires, through PVC conduit concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch, with concealed/surface box, modular surface plate, ceiling rose/holder etc.
Same as above but control shall be two way.
Supply, Installation, Testing & Commissioning of fan point wiring with 1.5 sq.mm. PVC insulated copper conductor FRLS wires, through PVC conduit, concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch & step type electronic fan regulator with concealed/surface box, modular surface plate etc.
Same as above but on lighting switch board ( Half Pt.).
Supply, Installation, Testing & Commissioning of 6 Amp. socket point wiring with 2x1.5+1x1.0 sq.mm.PVC insulated copper conductor FRLS wires, through PVC conduit, concealed or surface mounted on the ceiling/wall, with modular type 6 Amp. switch & 5 pin socket, concealed/surface box, modular surface plate etc.
Supply, Installation, Testing & Commissioning of 6 A sockets with modular type switches, concealed/surface box, modular surface plate etc., without any wiring & conduit ( wiring & conduit will be measured in mains ).
Supply, Installation, Testing & Commissioning of 6/16 A socket point wiring with 2x2.5+1x1.5 sq.mm.PVC insulated copper conductor FRLS wires, through PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type 16 Amp. switch & 6/16 A socket, concealed/surface box, modular surface plate etc.
Supply, Installation, Testing & Commissioning of 6/16 A socket point with modular type switches, concealed/surface box, modular surface plate etc., without any wiring & conduit (wiring & conduit will be measured in mains ).
Supply, Installation, Testing & Commissioning of Bell point wiring with 1.5 sq.mm, Bell push button, Bell buzzer all modular typr, PVC insulated copper conductor FRLS wires, through PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type bell push and reset type bell with indicator.
Supply, Installation, Testing & Commissioning of telephone point wiring with 2 pair telephone wire, through provided PVC conduit, concealed/surface mounted on the ceiling/wall with modular type RJ11 telephone socket, concealed/surface box, modular surface box etc. ( Telephone wire & PVC conduit will be measured separately ).
Supply, Installation, Testing & Commissioning of TV point wiring with RG 6 co-axial cable, through provided PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type TV socket, concealed/ surface box, modular surface plate etc. (RG 6 cable & PVC conduit will be measured separately ).
Supply, Installation, Testing & Commissioning of data outlet sockets with CAT 6 UTP cable, through provided PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type RJ 45 data outlet socket, concealed/surface box, modular surface plate and connection at both ends. ( CAT 6 UTP cable & PVC conduit will be measured separately ).
Supply & Installation of 25mm medium duty PVC conduit with standard accessories and to be used for concealed / surface mounted on the ceiling/wall.
Same as above but with 32 mm
Supply & Installation of 25 mm wire reinforced type flexible PVC conduit with PVC glands on both sides to be used for flexible copper wires / cables.
Same as above but with 32 mm
Supply, Installation, Testing & Commissioning of mains / sub-main wiring using FRLS type wires of 2x2.5 sq.mm. + 1x1.5 sq.mm. PVC insulated, multistranded copper conductor through existing PVC conduit. ( Measurement of conduit & wires shall be separate ).
Same as above but with 2x4.0 sq.mm. + 1x2.5 sq.mm.
Same as above but with 6.0 sq.mm
Same as above but with 4.0 sq.mm
Same as above but with 2.5 sq.mm
Supply, Installation, Testing & Commissioning of telephone wires of 2 pair with 0.5 mm dia. through existing PVC conduit.
Supply, Installation, Testing & Commissioning of Jelly filled armoured telephone cable of 10 pair with 0.5mm dia liad through existing HDPE pipes
Supply & Installation of 10 pair krone type telephone junction box.
Supply, Installation, Testing & Commissioning of Co-axial cable low voltage grade RG-11 through existing PVC conduit.
Supply, Installation, Testing & Commissioning of CAT 6 UTP data cable through existing PVC conduit.
Supply & Installation of 100x50 mm PVC plastic trunking with flexible cover, base joint, aluminium clip on partition, end caps, internal angle, clips etc.
Supply & Installation of 'B' grade GI pipe down rod duly painted for fan complete erected with PVC three core flexible cable of 1 sqmm copper PVC wire.
Supply, Installation, Testing & Commissioning of 4 way VTPN MCB DB with double door, comprising of following: Incoming : 63 A 4 pole MCB 10 KA 1 No. Outgoing : 32 A 3 pole MCB. 10 KA. 3 Nos. 16 A 1 pole MCB. 10 KA. 3 Nos.
Supply, Installation, Testing & Commissioning of 6 way PPI MCB DB with double door, comprising of following: Incoming : 25 A 4 pole MCB 10 KA 1 No. 25 A DP RCCB 30 mA Hpi type. 3 Nos. Outgoing : 10 A 1 pole MCB. 10 KA. 12 Nos.
Supply, Installation, Testing & Commissioning of 4 way PPI MCB DB with double door, comprising of following: Incoming : 25 A 4 pole MCB 10 KA 1 No. 25 A DP RCCB 30 mA Hpi type. 3 Nos. Outgoing : 10 A 1 pole MCB. 10 KA. 6 Nos.
Supply, installation, testing & commissioning of 8 way SPN MCB DB with double door, comprising of following: Incoming : 25 A DP RCBO 30 mA Hpi type. 1 No. Outgoing : 10 A 1 pole 10 KA MCB. 4 Nos.
Supply, installation, testing & commissioning of 8 way SPN MCB DB with double door, comprising of 25/32 A FP MCB 10 KA 2 Nos.
Supply, Installation, Testing & Commissioning of MCB & socket boxes of IP 65 annd having 16 Amp. DP MCB 10 KA with 16 Amp. 1 Ph. 3 pin Socket & 32 Amp. FP MCB 10 KA with 32 Amp. 3 Ph. 4 wire with E socket. PVC Box shall be combine for both the sockets.
Supply, Installation, Testing & Commissioning of MCB & socket boxes of IP 65 and having 16 Amp. DP MCB 10 KA with 16 Amp. 1 Ph. 3 pin Socket & 16 Amp. FP MCB 10 KA with 16 Amp. 3 Ph. 4 wire with E socket. PVC Box shall be combine for both the sockets.
Supply, Installation, Testing & Commissioning of 6 to 32 A DP MCB with MS box.
Supply, Installation, Testing & Commissioning of IP 65, PVC Junction box with 4way connectors & earthing terminal inside.
Supply, Installation, Testing & Commissioning of IP 65, PVC Junction box with 2way connectors & earthing terminal inside.
Supply, Installation, Testing & Commissioning of 20 Watt LED Capsule type IP 65 protection, suitable for surface mounting. System Efficacy >90, Colour Temp 6500K, CRI Value minimum 80, Operating Temperature is 0 Deg. Driver having voltage range of 120 - 300 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >=2.5 KV, inbuilt over voltage & under voltage protection. Complete with mounting bracket suitable for Surface mounting, wiring etc.
Supply, Installation, Testing & Commissioning of 15W LED Recess mounted Round Downlighter, 6500K, IP20, System Efficacy >90, CRI Value minimum 80, Driver having voltage range of 140 - 280 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >=2.5 KV, inbuilt over voltage & under voltage protection.
Supply, Installation, Testing & Commissioning of 6W LED Surface mounted Round Downlighter, 6500K, IP20, System Efficacy >90, CRI Value minimum 80, Driver having voltage range of 140 - 280 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >=2.5 KV, inbuilt over voltage & under voltage protection.
Supply, Installation, Testing & Commissioning of 7 watt (Colour Temp 5700/6000K)direct fitting LED bulbs.
Supply, Installation, Testing & Commissioning of wall mounted 70 watt LED Street Light, IP65 protection, luminaire with ADC housing & clear cover, Wall mounting bracket and accessory suitable for outdoor installation. System Efficacy >100, Colour Temp 6500K, CRI Value minimum 80, Driver having voltage range of 110 - 290 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >= 4 KV, inbuilt over voltage & under voltage protection. Mounting height of the fitting will be around 9.0 meters.
Supply, Installation, Testing & Commissioning of Integral LED post top 40 watt fitting, complete with wiring etc.
Supply, Installation, Testing & Commissioning of 1200 mm sweep 5 star rated ceiling fan with double bearing complete with wiring etc.
Supply, Installation, Testing & Commissioning of 225 mm sweep fresh air cum exhaust fan with bird screen.- cfm for ventilation fans is 425 (±10%)
Supply, Installation, Testing & Commissioning of 375/380 mm sweep heavy duty exhaust fan with bird screen.- cfm for ventilation fans is 1470 (±10%)
Supply, Installation, Testing & Commissioning of 450 mm sweep heavy duty exhaust fan with bird screen.- cfm for ventilation fans is 2650 (±10%)
Supply, Installation, Testing & Commissioning of audio, visual alarm system for cold storage rooms. Job involves solid state Annunciator with hooter & enclosure, installed in occupied area, stay-put type push button station in each cold rooms / pre cooling rooms, cabling from cold rooms / pre cooling rooms to Annunciator. Job involves following items. 4 points Annunciator - 1 No Stay-put type push buttons. - 4 Nos. 2Cx0.75 sq. mm.Copper Flexible multi stranded cable. - 150 Mtrs Medium duty PVC conduit of 25 mm size with standard accessories. - 100 Mtrs
PART-5: Miscellaneous Items
Pallets Dimensions: 1000mm X 1200mm X 150 mm approx. ht Colour: as approved by client Pallet type: four side fork opening Weight carrying capacity: 1500 Kg Suitable to use with all kind of material handling equipments including hand pallet trucks etc. Working Temperature range: (-) 25 deg C to (+) 10 deg C heavy duty type, Top Deck : Perforated MOC Shall be food grade plastic/HDPE and shall have excellent impact strength and high compression resistance. Acceptable makes: Nilkamal/Supreme / Eqvt
Hydraulically Operated Hand Pallet Truck Type : Hydraulically operated Hand Pallet Truck Manufacturer : Godrej / Toyota / Linde / Jungheinrich / Nilkamal / Josts / Eqvt. Model No. : to be mentioned Load Capacity in kgs: 1500 kg Fork Length in mm (Suitable for liifting pallet of size of 1000 mm X1200 mm X154 mm ) Wheel MOC : Nylon / Polyurethane Suitable for heavy duty operation and long life,
Overhauling of Machineries for 1 precooling chamber, 4 cold rooms ,ante-room , transformer, DG sets, HT/LT/APFC panels and other electrical system, dock,grading sorting line and overall any activity not mentioned but needed to carry out utilizing the equipment in effective manner. It is recommended that bidder shall visit the site and get the idea of quantom of work before quoting.
The details of the exisiting machinery is as follows, • PRE-COOLING CHAMBER:1 no, CDU (2 nos), Air Handling Unit 43 kW capacity, water pump: 1 x 3 Kw, 1 no • Cold Storage 1,2,3,4: CDU: air cooled condensing unit 1 no for each room., Air Cooling Unit: 13.5 KW each unit • Ante-room: Air cooled condesing nuit and indoor unit 1 nos • Evaporative air cooling units: Qty-2 nos • Air curtains, QTY: 13 Nos. • Grading Sorting Lines • Transformer: 200 KVA • DG set: 200 KVA • 11 KV Outdoor type MCCB panel • Main PCC panel • APFC panel:microcontroller based. • Lighting fixtures: internal as well as external street lighting of different wattage
Scope of Work for Refrigeration System: • Checking of operational log readings recorded by operators during the previous month.& Discussion operational problems, if any, with maintenance/operation staff. • Checking the actual performance of the machines and Checking & correcting the set parameters, if required. • Carrying out minor repairs. Replace minor parts ,if required. • Making recommendations to client for smooth & trouble free operation of the machines. • Cleaning & combing of ACU’s fins, suction filters, driers, pump ,strainers etc. •ACU fan & motor- routine & preventive maintenance • To check oil level in the compressor, if less then oil to be charged in to the compressor. • Check liquid sight glass to determine the shortage of refrigerant if any / to check moisture contained in the system. Top up if required. • Inspect system for visible signs of leaks. If found, attend the leaks. If any brazing work involved should be carried out by the contractor at his cost • Inspect & adjust, if required, all safety controls. • carrying out calibration of gauges, temperature , RH sensors etc, wherever caliberation time frame has exceeded • Inspect the condition of refrigerant and drain pipe insulation (drain pipe insulation wherever applicable).To be replaced if found not in good condition. • Condenser inlet air pre-cooling system - to be cleaned, pump repaired (if required), pipig cleaned and other routine and preventive maintenance.
Scope of Work for Insulated Sandwich Panels: • Insulated Panel Structure: Filling of silicon sealant as & where required to stop air leakages if any. • Floor Insulation – checking for gaps created between civil floor and wall insulation and sealing the same with silicon sealant / PUF filling depending on the size of the gap, if created during regular wear and tear or minor damage. • PUF foaming in case condensation due to leakage etc found. Scope of Work for Insulated Doors, Strip and Air curtains, Dock shelters: • Cleaning and oiling of rollers of doors • Gasket checking for leakage. Alignment of gasket if leakage is observed. • Replacement of gasket if gasket is damaged or found in improper condition. • P.V.C. strip Curtains: Replacement of PVC strips if any. • Air Curtains – check the overall condition. Replacement of blower/full unit, if required. • Dock shelter- check for any damage, leackage etc. appropriate action to be taken to so as to make them fully funcational. • Dock leveller: cleaning, lubricating the parts with proper lubracants, All necessary components are adjusted properly to make sure equipment works smoothly and consistently.check fluid level in hydraulic cylinders, top-up/ replace the fluid as may be necessary.
Scope of work for Electrical System: • Transformer: oil condition checking, leakages to be attended, testing of oil for various parameters as per standard practice, Filtration or replacement / top up of oil as per condition of oil, Insulation resistance of the transformer should be checked, Bushings should be cleaned and inspected for any cracks, checking of any loose connections of the terminations of HV & LV side, breather examination. Dehydration of Silica gel if necessary. Explosion-vent diaphragm examination. Conservator to be cleaned from inside. Cleanliness in the Substation yard with all nets, vines, shrubs removed. • DG set: Routine & preventive maintenance of DG sets with AMF panels including maintenance of controlling/protective accessories, battery check. Replace/charge as required. DG set general servicing as per manufacturers recommendation. replacement of filters etc. as required. •HT / LT panels: Check for loose connection of all terminals in the panels, Clean gently the dust by air pressure in side the panels, Check the mounting of CTs for its position, ensure that does not make contact with body, Check for loose connections for all power / neutral cable connections, Check for all the fuses, Check for loose connections of all power cables & control cables of panel, Check for loose connections of cables of meters / contractors, Check the outgoing & incoming phase, neutral connection of circuit breaker, Check the thermal trip of circuit breaker, Check mountings of circuit breaker & tightness of power cables. If anything mentioned above found not normal, same shall be rectified • APFC panel: Cleaning should done by using blower. Microcontroller not working condition to be replaced. Current of each capacitor should be measured and recorded once in month to know healthiness of each capacitor bank. Current should be measured by using clamp tester. If the value of current is less than 50% of the rated value. Capacitor should be replaced with new one. Connections should be checked for any loose connections. • Routine, preventive maintenance of Lighting & Power Distribution Systems. • Routine, preventive maintenance of HT, LT cables & Wirings. • Earth resistance measurement of all the Earth electrodes • Checking, fitting cleaning and fault rectification of the lighting fixtures
Scope of Work for Conveyor Line: • Motor - checking of alignment of motors • Bearing at various locations to be checked and oiled / greased wherever necessary • Lubrication to be carried out for all the rollers as necessary to avoid any squeaking noises. • Belt alignment • Pulley conditon checking • Heaters operation check and routine & preventive maintenance for dryer and hot water treatment units. • Washer Unit: water spray nozzels, brushes etc checking and routine maintenance. • Electronic weight sizer: routine & preventive maintenance. • Electrical control panel: routine & preventive maintenance. • Painting of parts wherever necessary to prevent parts from being rusted. Overall the grading sorting machineries are to be cleaned and made ready for use considering that they may be used for export oriented purpose. Parts that are coming in contact with the product during operation should be ensured to be of allowable SS or other food grade material. If any part like motor etc. needs replacement, then the cost of the motor / major part would be borne by the end-user / MSAMB / user but the installation and commissioning of the part shall have to be done as part of this contract and the labour costs and minor accessories for the same to be considered. For this, a site visit for seeing the condition of the equipment is extremely critical.
Evaporative air cooling units: • Remove the filer pads and clean them thoroughly with a pressurized water jet • Water Sump cleaning • Water pump routine & preventive maintenance • Fan and Belts- check condition, preventive and routine maintenace • Air leaks in ducting and Water Leaks- check and attend if any • Electircal & contro System- checking, preventive and routine maintenace
Training Hall Electrical Works
Projector for Training Hall
Supplying, installing, testing & comissioning of PROJECTOR - 3LCD, Brightness 5000 lumens , Contrast 5000:1 Resolution 1920 x 1200, Lamp Life 8000 Eco / 5000 Normal, , Full HD
Supplying, installing, testing & comissioning of HDMI cable Platinum 20/15 mtr 4K compability
MOT. SCREEN - Motorised imported screen (100" diagonal) with black border and tubular motor driving device with less noise and smooth fuctioning. Actual viewing area shall be 60" H X 80" W. (Imported High Contrast Silver Fabric 4k Full HD)
Supplying, installing, testing & comissioning of MOT. LIFT -Motorised projector Lift with Heavy duty, all metal construction with rack and tubular motor, mechanism should have quiet operation. The lift shall close at max 14 inches , including the projectorand shall be able to move down unto 42 inches for projection.
Audio/ Sound system for Training Hall
Supplying, installing, testing & comissioning of Wall mounting speakers with power of 30 watts, size-6.9", sensitivity upto 93db, frequency rate 60 Hz – 18kHz (-10 dB). White colour complete with wiring and required acessories etc
Supplying, installing, testing & comissioning of Premium In-Wall Two-Way Loudspeaker with 6-1/2" (165 mm) Woofer. Polymer-Coated Aluminum-Cone Woofer With Pure Butyl Rubber Surround, Low-Diffraction Swivel Aimable Titanium Tweeter. High-Slope Crossover Network, Paintable, 98 mm ( 3-7/8 in) Depth (For Wallboard Plus Stud). 88 dB Sensitivity, 100 Watts (50W RMS/200W Peak), 38 Hz to 20 kHz Frequency Response. ( Subwoofer 02no.) (1Pair) complete with wiring and required acessories etc
Supplying, installing, testing & comissioning of Multi Channel amplifier with 8 channels of 50W each Channels may be bridged in pairs for combined power, Terminals for remote control of channel levels/muting, Balanced line-level inputs on plug-in barrier strips, complete with wiring and required acessories etc
Supplying, installing, testing & comissioning of Lapel or Hand Microphone complete with wiring and required acessories etc
Supplying, installing, testing & comissioning of Table embedded microphones with high sensitivity guarantees a constant output level even from long distance sources. These microphones are designed for applications such as tele/video conferencing or recording. Frequency response -60 - 20,000 Hz Impedance 200 ohms complete with wiring and required acessories etc
Supplying, installing, testing & comissioning of A combination of 2 relays and 1 I/O to be used for each of the above switch, to activate/deactivate a microphone and to enable " look at me" feature complete with wiring and required acessories etc
Supplying, installing, testing & comissioning of Digital Sound processor with tele hybrid. NEXIA TC is a digital signal processor with 8 wide-band AEC mic/line inputs, 2 standard mic/line inputs, 4 mic/line outputs, and a telephone interface.(No need to have additional audio conf. unit) complete with wiring and required acessories etc
Video Conference system for Training Hall
Supplying, installing, testing & comissioning of Video Conference -R ealPresence Group 500-720p: Group 500 HD codec, EagleEyeIV-12x camera, mic array, univ. remote, NTSC/PAL. Cables: 2 HDMI 1.8m, 1 CAT 5E LAN 3.6m, 1 HDCI analog 3m, Power: UK-Type G, BS 1363. Maintenance Contract Required complete with wiring and required acessories etc
Supplying, installing, testing & comissioning of Partner Premier (Group Series) -Polycom Advantage, 3 Year, RealPresence Group 500-720p: Group 500 HD codec, EagleEyeIV-12x camera complete with wiring and required acessories etc
Supplying, installing, testing & comissioning of Group Series Multipoint License - 6-way on Group 500 or 8-way on Group 700. Both support 4-way HD continuous presence. NOTE- CALA and China include Maintenance in price. ROW require purchase of separate service Product ID complete with wiring and required acessories etc
Supplying, installing, testing & comissioning of Display 42" Full HD 1080 with Inbuild Wi-Fi & 3 HDMI Port / 2 HDMI Port complete with wiring and required acessories etc
Point wiring for light/fan/bell concealed type in min 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm. (2+1E) FR grade copper wires, moduler type switch, earthing and required accessaries as per specification No: WG-PW/CW 1.9.9
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete. 1.8.10
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete. 1.8.11
Supplying and erecting modular type electronic step regulator for fan two module ISI mark approved make duly erected on provided plate and box with wiring connections complete. Note: Add Rs 57/- provision of additional two modules for box and double plate 1.8.23
Supplying and erecting regular/ standard model Ceiling fan of 1400mm. sweep complete erected in position as per specifcation no. FGFN/CF 2.12.3
Supplying and erecting Exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specifcation no. FG-FN/EXF 2.12.18
Supplying and erecting Exhaust fan heavy duty 230 V A.C. 50 cycles 375/380 mm. 1400 RPM complete erected in position as perspecifcation no. FG-FN/EXF 2.12.17
Supplying and erecting LED square / circular 16 to 20W downlighter having pressure diecast aluminimum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. 2.1.5
Supplying and erecting LED square / circular 13 to 15W downlighter having pressure diecast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. 2.1.4
Supplying and erecting Ding Dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size 2.4.13
Supplying and erecting LED Street light fitting suitable for 60w lamp, including lamp, with PF > 0.95 class IP 65 and above Housing of pressure die cast alluminium alloy and heat sink extruded alluminium complete per specification No . FG-ODF/FLS2. 2-5-5
Supplying and erecting street light Wall bracket made from 40 mm.dia ‘B’class G.I. pipe 1.2 m in total length complete as per specificationno. FG-BKT/WB 2.9.4
Supplying, installing, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 2 TR capacity having ISEER minimum 3.50 to maximum 3.99 suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete with Refrigerants R410 A/R32 and copper condenser at position. specification no. AP-AC/SAC 3.2.6
Supplying & erecting original 1.25 mm CRCA sheet metal enclosures with 20A. 2 pin plug & earth socket and 20A. 3 pin plug top with 20A/30A single pole MCB complete erected on angle iron/ G.I. frame.. 5.4.20
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification No. SWSWR/ MCB 5.3.2
Supplying, erecting & marking TPMCB 6A to 32A in provided distribution board as per specification No. SW-SWR/MCB 5.3.14
Supplying and erecting Bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A complete as per specification no. CP-BB 6.2.1
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .