| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹49.9 L+₹1.3 L (2.64%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹50.3 L+₹1.7 L (3.54%)Rejected-Finance VIVEKA HOME 207 D UDANGUDI ROAD TISAYANVILLAI 627657 TIRUNELVELI | TISAYANVILLAI | TIRUNELVELI | TAMIL NADU | 627657 | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹51.2 L+₹2.6 L (5.42%)Rejected-Finance CHENNAI | L4 | Rejected-Finance L1 being accepted |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
15 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Tirunelveli
GE TIRUNELVELI INS KATTABOMMAN NAVAL BASE POST VIJAYANARAYANAM TIRUNELVELI
GE/TVL/8166
2021_MES_452935_1
GE/TVL/8166
Open Tender
Miscellaneous Works
Item Rate
180 days
Ramnad
As per NIT/ Tender documents
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹90,000
Yes
9 Aug 2021
19 Jun 2021
17 Jul 2021
19 Jun 2021
15 Jul 2021
3 Jul 2021
19 Jun 2021 - 28 Jun 2021
60 days
Amount
SCHEDULE 'A' PART-I [ B/R WORKS]
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth, for foundation/laying cable in Hard/Dense soil and getting out complete all as specified and directed.
Material and Labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation complete all as specified and as directed.
Material and Labour for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in foundation, coping complete all as specified and as directed.(Note:- Form work will be measured & paid separately)
Supply and fix for rolled sections as in main and cross beam, hip and jack rafter purlins where connected to common rafter and running rails and guides for sliding door,fixed with angle cleats or other connecting plates etc conforming to Fe 410-W (Gde-E-250) complete all as specified and directed.
Material and labour for roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410-W (Gde-E-250) complete all as specified and directed.
Supply and fixing galvalume single skin corrugated profiled/ Plain roofing sheet of 0.50mm thickness (Total coated Metal thickness) having tensile strength of 550 MPa, coated with hot dip metallic zinc aluminium alloy coating zincalume AZ-150 or equivalent (as per AS 1397) @ 150 gms/sqm, total on both sides of ZN (45%) & AL (55%), with super polyester colour bond XRW quality paint coat or equivalent as per AS/NZS-2728 (Category 3-4) of approved colour, total coating thickness of 35 microns of a super polyester XRW quality paint system or equivalent comprising of 20 microns (NOM) exterior coat on top surface and 5 microns (NOM) reverse coat on back surface over 5 microns (NOM) primer coat, on both surface, of approved colour shade fixed with GI self tapping fastening bolt/screw as in roof covering/cladding etc as per manufacturers instructions complete all as specified and as directed.
All as per item No.7 above but 0.5mm thick prepainted plain galvalume sheeting as in ridge and gate covering fixed with GI self tapping screw complete all as specified and as directed.
Supply and fix for MS Plates (plain or chequered)channels, square cut or notched (ordinary and counter sunk)forming holes, with riveted, bolted or welded attachment complete all as specified and as directed.
Supply and fix for mild steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-410 or Fe-310 complete all as specified and as directed.
Supply and fix Mild steel screw bolts (machine made) with hexagonal or square heads at one end and each screwed end to be fitted with washers and one hexagonal or square not exceeding 30cm long & dia exc 20mm and n exc 25mm complete all as specified and as directed.
Removing excavated material / soil to a distance exe 250m & n.exc 500m away and depositing where as directed at a level n.exc 1.5m above the starting point, complete all as specified and as directed.
M&L for Preparation of new untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Surface excavation n.exc. 30 cm deep and averaging 15 cm deep and getting out in any type of soil and etc complete all as specified and as directed
Material and labour for 15mm thick rendering in cement mortar 1:4, on fair faces of brick/concrete surfaces finished even and smooth with out using extra cement complete all as specified and as directed.
M&L Preparation of newly plastered surface and applying two coats of cement based paint on walls over a coat of alkali resistant primer complete all as speciifed and as directed.
M&L Formwork with fair finish surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc complete all as speciifed and as directed.
Demolition of cement concrete in ground floor & paving n. exc 15 cm thick (below or above GL) unreinforced complete all as specified and directed.
Material and labour for providing plain cement concrete 1:2:4 type B0, using 12.5mm graded stone aggregate as in flooring/sub base 25mm thick finished even and fair including form work all as specified and as directed.
Material and Labour for Vitrified ceramic coloured tiles double charged/dark shade 10mm thick (square/rectangular) area of each tile exceeding 0.42 Sqm and not exceeding 1.00 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed of 15mm thick in CM 1:6 complete all as specified and as directed.
Material and Labour for vitrified ceramic tiles 10mm thick double charged /dark shade (Square / rectangular) polished, area of each tiles exceeding 0.42 Sqm and not exceeding 1.00 Sqm, as in vertical surface, over and including provision of cement bedding 10 mm thick in CM 1 : 4 set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and as directed
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles all as specified and as ditected.
Material and labour for Brick work with old size subclass 'B' brick straight or curved on plan exc 6m mean radius and built in CM 1:4 complete all as specified and as directed.
Material and labour for preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over two coat of primer over a coat of wall care putty complete all as specified and as directed.
Material and labour for Complete removal of existing treatment including preparation of wall surfaces and applying two coats of oil bound distemper over two coat of primer over a coat of wall care putty complete all as specified and as directed.
Supply and fix powder coated door shuters, aluminum sections weighting 0.55 kg/m including necessary joining cleats, glazing clips, rupper packing anodised aluminum snap beading, screws, anodised aluminum fitting such as suitable handle (2 No) in each door hinges complete all as specified.
Supply and fix powder coated aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
Supply & fix sheet glass 5.5 mm thick ordinary quality and glazing with oil putty or aluminium snap beading in square exceeding 0.5 Sqm in each panel complete all as specified and as directed.
Supply and fixing 12mm thick Prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination fixed with screws to frame work complete all as specified as directed.
Supply & Fixing of Minerals fibre acoustic suspended ceiling system with fine fissured tiles with Silhouette exposed grid, the tile should have humidity restance (RH) of 99%, NRC upto 0.6, light reflectance 88%, thermal conductivity (K) 0.052 to 0.057 w/m, colour white, fire performance class O/class 1 (BS476 part 6&7) in module size of 600 x 600 x 16 mm thick with Bio block coating on the face of the tile, impact resistant and suitable for green buikding application with recycled content of 63%. The tile shall be laid on silhouette profile grid system with 15mm white / black colour and with web height of 38mm and load carrying capacity of minimum 11.68 kg / sqm. Silhouette main runner and cross tees to gave mitred ends and birdsmouth notches to provide mitred cruciform junction. The "T" sections have galvanising of 120 gms/sqm and passed through 500 hrs of salt test, the tile and grid system used together should carry a 15 year warrantee, including dismantling of wall & ceiling boards (fibre, pulp, insulation etc.,) or insulation board / bracets, runners etc any thickness, including cover fillets complete all as specified and directed. Make : Armstrong/saint gobain/Twiga Insulation/Kingston /Aerostone
SCHEDULE 'A' PART-II [ E/M WORKS]
Taking down carefully copper/aluminium point wiring (light, fan, socket and power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc and seperate the serviceable items like fan regulator and light fittings for re-use under respective items and remove unserviceable material out of site and making good disturbed surfaces of walls, floors etc complete all as specified and as directed.
Material and labour for Point wiring complete with FRLS PVC insulated unsheathed cable 1100V grade conforming to IS-694, 1.5 Sqmm (nominal area) multistranded with copper conductor drawn through and including non metallic rigid PVC conduit 20mm dia (ISI marked) and accessories, wall / surface (concealed) on ceiling with sunken type pressed steel / welded terminal boxes made out of 2mm mild steel sheet, 3mm thick laminated sheet cover for mounting of switches, socket outlets, regulators etc., including provision of FRLS PVC insulated unsheathed 1.5 Sqmm FRLS multistranded with copper conductor as earth continuity conductor and connecting to common earth dolly complete all as specified and as directed for the following:-
(a) One light point , controlled by one switch complete
(b) one fan point, controlled by one switch complete
(c)One 3 pin 5 Amps switch socket combination on independent board
(d)One 3 pin 5 Amps switch socket combination on the same board with other switches
All as per Item No. 33, but 4 Sqmm size copper conductor cable FRLS and 4 Sqmm copper earth wire cable FRLS drawn through 20 mm dia PVC conduit including provision of conduit and conduit accessories for One 3/6 pin, 15 Amps Multi purpose switch socket combination on independent board complete all specified and as directed.
M & L for ceiling rose, surface bakelite, 65x50mm, two to three terminals, including taking down unserviceable ceiling rose complete all as specified and as directed by the Engineer-in-Charge
S & F in repair Modular Switch, 1 Way, 6A, 1 Module including taking down of unserviceable item complete all as specified and as directed.
S & F in repair Modular Switch, 1 Way, 16A, 1 Module including taking down of unserviceable item complete all as specified and as directed.
S & F in repair Modular Socket, 6A, 2/3 pin combined, 2 Module including taking down of unserviceable item complete all as specified and as directed.
S & F in repair Modular Socket, 6A / 16A, 2/3 pin combined, 2 Module including taking down of unserviceable item complete all as specified and as directed.
S & F in repair Fan step regulator, 120 W, 2 Module including taking down of unserviceable item complete all as specified and as directed.
S & F in repair Modular White cover plate with frame, 3 Module including taking down of unserviceable item complete all as specified and as directed.
S & F in repair Modular White cover plate with frame, 4 Module including taking down of unserviceable item complete all as specified and as directed.
S & F in repair Modular White cover plate with frame, 8 Module including taking down of unserviceable item complete all as specified and as directed.
S & F in repair Modular Metal flush box, 3 module including taking down of unserviceable item complete all as specified and as directed.
S & F in repair Modular Metal flush box, 4 module including taking down of unserviceable item complete all as specified and as directed.
S & F in repair Modular Metal flush box, 8 module including taking down of unserviceable item complete all as specified and as directed.
Material and labour for Sub main wiring with PVC insulated unsheathed 1100 volts FRLS grade single core multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and including 32mm dia PVC conduit heavy duty ISI marked(IS 9537 Part III) fixed in walls (Concealed) and all accessories along with 1 run of 4 sqmm PVC insulated unsheathed copper conductor single core multi stranded cable 1100V FRLS grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed. Note: 2 runs of 4 sqmm cable along with 1 run of 4 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length.
M & L for single pole and neutral (SPN) sheet metal enclosure with a two pin and earth plug and socket complet with one single pole MCB 240 V, 20 amp including taking down old unserviceable item complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, SPN 8 way DB with Degree of Protection IP 42 , Detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, dismantling from position unserviceable DBs complete for taking into credit all as specified and as directed.
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, VTPN 6 way DB suitable for MCCB Incomer IP 43 , IK 09 ,provided with insulated vertical phase bus-bars ,neutral bar/s with shroud/s ,earth bar/s , sticking saddles ,cement spill protector ,color-coded interconnecting wire set ,cable ties , blanking plates and circuit identification labels. including , Disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and as directed.
Supply and fix MCB SP 5 A to 32 A , B curve, 10 kA including , disconnecting electric connections, dismantling unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix MCB SP 40A , B curve, 10 kA including , disconnecting electric connections, dismantling unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix MCB SPN 40 A , B curve, 10 kA including , disconnecting electric connections, dismantling unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix MCB TP 40A to 63A , B curve, 10 kA including , disconnecting electric connections, dismantling unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size omplete all as specified and as dirceted. Make: Crompton /Philips/ Havells/Bajaj/C&S
Supply and fix ceiling fan 1200mm sweep, minimum 2 years product warranty, with heavy duty double ball bearings with tolerance, hardened carbon steel balls with protective seal lubricated with high quality grease for smooth running, well balanced wider blades made out of aluminium sheet, properly angled and designed for optimum air delivery, glossy and mat finished powder coated paint, high quality finish using latest painting equipments i.e., rust proof, scratch resistance, glossy finish long life durability and connecting to ceiling rose terminals with 1.5sqmm copper flexible cable complete all as specified and as dirceted. Make : Almonard / Crompton Greaves/Orient / USHA Note : Colour of the fan will be decided by Engineer-in-Charge.
Supply and fix MCCB FP 100 A ,415v 50Hz with rupturing capacity 25 kA including , disconnecting electric connections, dismantling unserviceable MCCB for taking into credit complete all as specified and as directed.
Earthing complete with GI earth plate electrode 600 x 600 x 6.0mm buried directly in ground vertically to a depth not less than 2.25 M below GL with top edge of the earth plate not less than 1.5 M below normal GL connected with GI earth wire 4mm dia by means of bolts, nuts check nut and washers of GI and earth wire protected by GI pipe 40mm bore light grade and watering pipe 20mm bore GI pipe medium grade including one test point for testing purpose with funnel and connected to switch/control board upto 7.5m away from earth electrode including earth work, PCC (1:3:6) type C-1 chamber, RCC (1:2:4) type B-1cover slab 50mm thick with 8mm dia TMT bars reinforcement both ways at 140mm C/C, charcoal, salt, water pipe, wire mesh, lugs etc and testing complete all as applicable and as per Plate No. 3 of SSR 2009 and all as specified. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh,40mm dia light grade GI protection pipe for earth strip etc., complete.The rate quoted shall be deemed to include for Earth continuity conductor and GI protection pipe upto 7.5m.
Earthing complete with Copper earth plate electrode of size 600mmX600mm, 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to copper earth strip 20x3mm by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.3 earth strip protected by GI pipe 40mm bore light grade for protection extend of 7.5M as earthing lead and watering pipe 20mm bore GI pipe medium grade connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion including taking down old complete Earthing system all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh,40mm dia light grade GI protection pipe for earth strip etc., complete.The rate quoted shall be deemed to include for Earth continuity conductor and GI protection pipe upto 7.5m.
Supply ,install and testing split Air conditioner of 1.5 TR capacity inverter type 5 Star rating with indoor and outdoor units (copper condenser coil, copper cooling coil and evaporator including required length of copper tubing and cables for connecting indoor and outdoor units ) complete with cordless remote control unit , with inverter rotary compressor with minimum 10 yrs warranty ,complete all as specified and as directed. Make : VOLTAS / BLUESTAR /CARRIER/ O GENERAL/HITACHI. Note : Rate quoted is inclusive of the following:- (i) Drain pipe UPVC with insulation from indoor unit (at any floor) to ground floor level and is to be fixed with necessary clamps complete. (ii) Drilling hole on the brick wall to facilitate routing of Copper pipe, drain pipe and cable from indoor unit to outdoor unit. (iii) Sealing the hole from outside ,after installation, with white cement. (iv) Pressure testing , cooling performance check and product demonstation. (v) 4 core cable of any required length for connecting indoor and outdoor unit. (vi) Material and labour for fixing Remote stand in wall. (vii) Copper pipe, 1/2" dia and 1/4 " dia upto 3.00 Mtr each.
Supply and fixing of GI powder coated brackets , for fixing of split AC's including grouting with suitable size fastners complete all as specified and directed.
Supply and fixing Copper pipe 1/2" dia with foam insulation including connecting complete all as specified and directed.
Supply and fixing Copper pipe 1/4 " dia with foam insulation including connecting complete all as specified and directed.
Supply and fix LT under ground cable 1100 volts grade PVC /XLPE sheathed armoured multistranded heavy duty electric cable with aluminium conductor 3.5 core 95 Sqmm, laid in trenches/ duct / walls including cable gland on both termination where necessary including laying, connecting to various switches in panel board, testing and commissioning etc complete all as specified and directed. NOTE: Earth work excavation shall be measured and paid separately.
Supply and fix LT under ground cable 1100 volts grade PVC /XLPE sheathed armoured multistranded heavy duty electric cable with aluminium conductor 3.5 core 50 Sqmm, laid in trenches/ duct / walls including cable gland on both termination where necessary including laying, connecting to various switches in panel board, testing and commissioning etc complete all as specified and directed. NOTE: Earth work excavation shall be measured and paid separately.
Returning, filling in incl spreading leveling, watering and well ramming in layers n.exc.25cm thick complete all as specified and as directed.
Removing excavated material to a distance n.exc 50m away and depositing where as directed at a level n.exc 1.5m above the starting point, complete all as specified and as directed.
Supply and spread natural river sand in trenches for cushioning and covering to cable complete all as specified and as directed. NOTE: Punned thickness shall be measured and paid.
Supply, lay in trenches burnt Bricks, old size, Sub class "B" for cable protection all as specified and directed.
Supply and fix energy saving LED street light fittings, 35 Watts or nearest higher wattage, with in-built electronic driver, IP 66 class of protection with versatile pressure die-cast aluminium body, toughened glass cover with silicon gaskets and energy efficient LED and connecting up light fitting with copper conductor cable of suitable size from junction box to connector block including all accessories and dismantling of old unserviceable fitting for taking into credit complete all as specified and as directed. Make:Crompton /Philips/Bajaj/ Havells
Supply and fix 32 mm dia light grade GI tube bracket of length 1.5 metre bend to required shape including MS clamp made out of 30 mm x 6 mm MS flat iron and fix on poles/wall with necessary GI bolts, nuts and washers - 2 sets for each fittings complete set all as specified and directed.
Supply and laying GI tubing Light grade of size 40 mm dia bore laid in trenches / on floors / walls/ceiling for protection of UG cable complete all as specified and as directed.
Cutting the existing bituminous road / cement concrete surface to the required width and depth for laying pipe lines and returning filling in, removal of surplus material complete all as specified. Note: PCC for making good the top level to match raod surface shall be measured and paid separately.
Labour only for removing interlocking tiles and refixing after returning filling and laying of cable/ pipeline and compacted earth surface to match with existing adjecent surface level complete all as specified and directed.
Supply and fixing ON Load change over with sheet metal enclosure switch 4 pole- 160 Amps including end terminal connections complete all as specified and directed.
Supply and fixing ON Load change over with sheet metal enclosure switch 4 pole- 250 Amps including end terminal connections complete all as specified and directed.
Supply and laying, in repair of galvanised steel water tubes, medium grade 32mm bore with and including all necessary GI fittings such as bends, elbows, short piece connections, backnuts, caps plugs, unions etc., laid in trenches/wall/ceiling including testing and taking down old complete all as specified and as directed.
Supply and laying, in repair of galvanised steel water tubes, medium grade 25mm bore with and including all necessary GI fittings such as bends, elbows, short piece connections, backnuts, caps plugs, unions etc., laid in trenches/wall/ceiling including testing and taking down old complete all as specified and as directed.
S & F gun metal globe or gate valves with iron wheel head screwed head scrwed both ends for iron pipe and fixed, 32 mm bore, including removing old unserviceable item complete all as specified and as directed by the Engineer-in-Charge
S & F of gun metal gate valve, painted finish, with forged brass spindle and iron wheel head, screwed both ends internally IS-778 marked, Class-2, for iron pipe of size 25mm bore including removing old unserviceable item complete all as specified and directed.
Material and Labour for construction of masonry valve chamber internal size 100cm x 100cm x 100 cm including 150 mm thick PCC (1:4:8) type D2 foundation using 40mm graded stone aggregate, brick work in CM (1:6) plastering internal sufaces completely and external surfaces upto 150 mm belowground level, 15 mm thick in CM (1:4) 100 mm thick (1:3:6) Type C1 coping 40x40x6 mm angle iron with 3 mm thick MS sheet cover complete with handle locking arrangement including painting steel and iron surfaces with two coats of synthetic enamel paint over a coat of zinc primerincluding necessary excavtion earth work in any type of soil complete all as specified and as directed.
Supply and installation, testing,commissioning of water cooler partially stainless steel electric driven single phase having approx storage 80 ltrs and nominal cooling capacity 40 ltrs/hr with complete all as specified and directed by Engineer-in-Charge. Make- Blue star PC 480 OR equivalent make in Voltas / Usha /LG
Supply, fixing, testing and commissioning of refrigerator, electric driven (single phase) with inverter compressor,308 litres capacity complete all specified and as directed. Make- LG/Whirlpool/Samsung/Haier
Supply & fix single pointed air termination aluminium rod 12mm dia, 300 mm long to be fixed on building of not more than four storey high complete all specified and as directed.
Supply & fix aluminium strip 25mm x 3mm complete with saddles and fixing screws for fitting the strip to be fixed on building of not more than four storey high and overhead tank upto 15 m height complete all specified and as directed.
Supply & fix single pointed air termination aluminium rod 12mm dia, 300 mm long to be fixed on overhead tank of height more than 15 m and not exceeding 30 m height complete all specified and as directed.
Supply & fix aluminium strip 25mm x 3mm complete with saddles and fixing screws for fitting the strip to be fixed on overhead tank of height more than 15 m and not exceeding 30 m height complete all specified and as directed.
Supply and fixing of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip complete all as specified and directed.
M & L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
Earthing complete with GI earth plate 600mmX600mm x 6 mm thick buried directly in ground/ earth pit not less than 2.25M below ground level with top edge of the plate not less than 1.5M below ground level connected to GI earth strip 32 x 6 mm by means of bolts, nuts and washers of GI earthing strip protected by GI pipe i.e. light grade 40mm dia all as shown in electric plate No.5 of MES SSR Part I connected to earthing test point, testing complete including necessary earth pit PCC 1: 3: 6 chamber and 50mm thick PCC 1 : 2: 4 chamber cover and with 6mm dia mild steel re-enforcement of 10Cm C/L spacing both ways in lieu of CI cover refilling of soil ncluding taking down old complete Earthing system etc complete all as directed by Engineer-in-Charge. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 40 mm dia watering pipe, wire mesh, 50mm dia light grade GI protection pipe for earth plate etc., complete
M & L for 85 mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate for making good the disturbed road surface after laying of pipe line over returned filled and compacted earth surface to match with existing road level complete all as specified and as directed.
M & L for Prestressed concrete pole 9.0 metres long, 102x172mm at top and 102x279mm at bottom, class 10 including foundation(1:3:6) type C2 and coping(1:2:4) type B1 formwork etc. complete all as specified and directed. Note:- Size of the foundation & coping shall standard size or as directed by Eng-in-charge.
S&F in energy saving LED street light fittings, 70 Watts or nearest higher wattage, with 10 kV Surge protection device ,in-built electronic driver, IP 66 class of protection with versatile pressure die-cast aluminium housing parts, pure polyester powder coated dark gray housing, toughened glass cover with silicon gaskets omplete all as specified and directed.
S & F in replacement pole mounting type FRP cable looping box of size 150mm x 200mm x 100mm with 40 x 6mm flat iron with connector including suitable brass gland, lugs etc and terminal box to be fixed on pole with suitable fixing arrangement complete all as specified and as directed.
Material and labour for Sub main wiring with PVC insulated unsheathed 1100 volts FRLS grade single core multi stranded copper conductor cable 2 runs of 2.5 sqmm drawn through in and including 20mm dia PVC conduit heavy duty ISI marked(IS 9537 Part III) fixed in walls and all accessories along with 1 run of 2.5 sqmm PVC insulated unsheathed copper conductor single core multi stranded cable 1100V FRLS grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed. Note: 2 runs of 2.5 sqmm cable along with 1 run of 2.5 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length.
Supply and fix 40 mm dia light grade GI tube bracket of length 1.5 metre bend to required shape including MS clamp made out of 40 mm x 6 mm MS flat iron and fix on poles/wall with necessary GI bolts, nuts and washers - 2 sets for each fittings complete set all as specified and directed.
Supply, fixing, install, commissioning and testing complete, Online UPS System with minimum 30 min back up 3 Phase, 10 KVA with Output 3 Phase, 415 Volts, 50 Hz, IGBT based pure true online system complete all as specified and directed . Make : Numeric (LEGRAND)/Luminous/Microtek/Uniline/Sakthi electrical controls
Supply and fix 12V, 75 AH SMF Battery complete all as specified and directed . Note : The quoted rate deemed to inclusive of suitable battery open rack, DC Cables, battery MCB and all necessary accessories.
Material and Labour for sub main wiring with single core 1100 V FRLS grade conforming to IS 694 PVC insulated unsheathed cables four run 10 Sq mm multi stranded copper conductor drawn through and including 32 mm dia non metallic PVC rigid conduit and conduit accessories fixed on walls/roof/floors/ceiling etc with an earth wire of one run 10 sqmm copper wire earth continuity conductor etc and making good disturbed surfaces to match existing all as specified and directed. Note : Five runs of 10 sqmm cable and one run of PVC conduit shall be measured as one run.
Material and Labour for sub main wiring with single core 1100 V FRLS grade conforming to IS 694 PVC insulated unsheathed cables two run 10 Sq mm multi stranded copper conductor drawn through and including 25 mm dia non metallic PVC rigid conduit and conduit accessories fixed on walls/roof/floors/ceiling etc with an earth wire of one run 10 sqmm copper wire earth continuity conductor etc and making good disturbed surfaces to match existing all as specified and directed. Note : Three runs of 10 sqmm cable and one run of PVC conduit shall be measured as one run.
Supply ,installation, testing and commissioning of silent 82.5 KVA Diesel Engine driven generating sets(Genset assembled with sound proof canopy), 415 volts, 3 phase, 4 wire, 50Hz, 1500 RPM engine as per IS:10001/10002 and Alternator as per IS: 13364 complete (as per OEM design), standard contorol panel with necessary meter, acoustic sound proof canopy as per MoEF / CPCB norms, fuel tank, battery & leads, residential silencer, AVM pads and mounted on MS fabricated base frame painted in corrosion resistant paint, including all fittings / fixtures as per OEM and first fill of lube oil, complete all as specified in the particular specifications and as per OEM's instructions, complete all as specified and directed.
Item No 108 Cont...... Note:- (a)The rate quoted deemed to including to provide PCC foundation minimum grade shoud 1:2:4 Type B1 ( using 20mm graded aggregate) for installation of DG set ,size and design as per OEM norms fuilfill safty and technical requirement with minimum working space 1mtr around the DG set including earth work, form work , necessary foundation bolt etc as per design for fixing of DG set. (b) The design and drawing of foundation shall be prepared based recommended by OEM and be got approved from Accepting Office before commencement of work and the rate quoted deemed to include for the same. (c) 05 Set of design and drawing to be submitted along with a copy the Accepting officer. (d) The rate quoted deemed to including to provide AMF panel as per OEM suitable for genset 82.5KVA. (e) The rate quoted deemed to including civil works,unloading & positioning of DG set at groun floor, connecting earthing 4 Nos as per OEM instruction.
Supply and fix LT under ground cable 1100 volts grade PVC /XLPE sheathed armoured multistranded heavy duty electric cable with aluminium conductor 3.5 core 70 Sqmm, laid in trenches/ duct / walls including cable gland on both termination where necessary including laying, connecting to various switches in panel board, testing and commissioning etc complete all as specified and directed. NOTE: Earth work excavation,sand cusion, cable protection shall be measured and paid separately.
Supply and fixing manually operated ON Load change over with sheet metal enclosure switch - 100 Amps including end terminal connections complete all as specified and directed.
Supply and fix double compression copper stainless steel gland for fixing armoured cable of size 3½ core 50 sq mm to 70 sq mm complete all as specified and directed.
AnnaiEnterprises
Vinayaga constructions
VVM CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .