Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8,474.55Admitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹14,512.06+₹6,037.51 (71.2%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹1.8 L+₹1.7 L (1987.1%)Admitted-Finance B 188 19 JAI TAIWAN COLONY 1ST TONK ROAD JAIPUR 18 | JAIPUR | JAIPUR | RAJASTHAN | L3 | Admitted-Finance | |
| 4 | Not Admitted-Fee/PreQual/Technical MADAN GIR NEW DELHI | - | Not Admitted-Fee/PreQual/Technical No EMD or Fee received | |
| 5 | Rejected-Technical 8 CHANDIVALI STUDIO ROAD ANDHERI EAST MUMBAI MAHARASHTRA 400072 | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | - | Rejected-Technical Technically Rejected |
| Sl No | Description | Qty | Unit | S.R. Enterprises L3 | Medicure Pharma L2 | Electrotech Govind L1 |
|---|---|---|---|---|---|---|
| 1.00 | HIV Elisa Method Test Kit – HIV Test Kit (Elisa Method) 4th Generation, if 4th generation kits is not available then only 3rd generation kits will be accepted. | 1 | 1500 x 96 Tests Kits | 14,400 ₹15,120 | 1,280 ₹1,344 Lowest | 1,782 ₹1,871.1 |
| 2.00 | HCV Elisa Method Test Kit – HCV Test Kit (Elisa Method) 4th Generation, if 4th generation kits is not available then only 3rd generation kits will be accepted. | 1 | 1000 x 96 Tests Kits | 90,000 ₹94,500 | 1,550 ₹1,627.5 Lowest | 1,650 ₹1,732.5 |
| 3.00 | HCV Rapid Method Test Kit – (4th Generation)
1. Long expiry of at least one year
2. Pack Size – 1 x 100 Tests
3. Test should be packed in moisture barrier pouch along with desiccant/silica pouches.
4. Flow rate complete within 15-30 mints
5. Kit should have buffer, conjugate and other accessories etc., required for running the tests.
6. Company should ISO certified. | 1 | 3500 x 100 Tests Kits | 566.4 ₹594.72 Lowest | 5,850 ₹6,142.5 | 2,460 ₹2,583 |
| 4.00 | HbsAg Elisa Method Test Kit – HbsAg Test Kit (Elisa Method) 4th Generation, if 4th generation kits is not available then only 3rd generation kits will be accepted. | 1 | 2000 x 96 Tests Kits | 13,500 ₹14,175 | 2,970 ₹3,118.5 | 990 ₹1,039.5 Lowest |
| 5.00 | HbsAg Rapid Method Test Kit –
1. Long expiry of at least one year
2. Pack Size – 1 x 50 Tests
3. Test should be packed moisture barrier pouch along with desiccant/silica pouches.
4. Flow rate – Test should be complete within 5- 10 mints
5. Kit should have all the accessories necessary for running the kit
6. The company should be ISO Certified | 1 | 8100 x 50 Tests Kits | - | 666 ₹699.3 | 338 ₹354.9 Lowest |
| 6.00 | Anti – A (Monoclonal) 10 ml (Anti Sera should be transparent with more than one year shelf life at 2-6oC, it should give +++ agglutination at 1:256 dilution in 3-4 seconds, with A positive cells). Reagents do not show a reaction with crypt antigen. | 1 | 4500 vials of 10 ml each | 7,395 ₹7,764.75 | 58.5 ₹61.43 Lowest | 63 ₹66.15 |
| 7.00 | Anti – B (Monoclonal) 10 ml (Anti Sera should be transparent with more than one year shelf life at 2-6oC, it should give +++ agglutination at 1:256 dilution in 3-4 seconds, with A positive cells). Reagents do not show a reaction with crypt antigen. | 1 | 4500 vials of 10 ml each | 7,012 ₹7,362.6 | 58.5 ₹61.43 Lowest | 63 ₹66.15 |
| 8.00 | Anti – D (Monoclonal) 10 ml (Anti Sera should be transparent with more than one year shelf life at 2-6oC, it should give +++ agglutination at 1:128 dilution in 10-20 seconds, with A positive cells). Reagents do not show a reaction with crypt antigen. | 1 | 4500 vials of 10 ml each | 8,021 ₹8,422.05 | 130 ₹136.5 Lowest | 135 ₹141.75 |
| 9.00 | A1 Lectin – 5 ml (Antisera should be transparent with 2 years shelf life at 2-6oC, it should give agglutination at titer 1:132 with A1 cells and 1:16 with A, B Cells avidity 15-20 second. No agglutination with A2 cells and O cells) | 1 | 100 Vials of 5 ml each | 1,970 ₹2,068.5 | 298 ₹312.9 | 205 ₹215.25 Lowest |
| 10.00 | Anti H – 5 ml (Antisera should be transparent with 2 years shelf life at 2-6oC, it should give reaction with O cell at titer 1:16 with avidity of 15-20 seconds, with A1 cell at titer of 1:8 and no reaction with Oh cells) | 1 | 100 Vials of 5 ml each | - | 298 ₹312.9 | 205 ₹215.25 Lowest |
Tender Value
₹4 Cr
EMD Value
₹4 L
Closing Date
1 Dec 2020, 5:00 pmClosed
Medical Superintendent, SMS Hospital, Jaipur
SMS Hospital, Jaipur
Blood Bank Reagents, Kits and Anti Sera
2020_SMSMC_205186_1
3209_05.11.2020
Open Tender
Miscellaneous Goods
Item Wise
730 days
SMS Hospital
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Medical Superintendent, SMS Hospital, Jaipur
₹4 L
Yes
31 Mar 2021
6 Nov 2020
2 Dec 2020
6 Nov 2020
1 Dec 2020
7 Nov 2020
HIV Elisa Method Test Kit – HIV Test Kit (Elisa Method) 4th Generation, if 4th generation kits is not available then only 3rd generation kits will be accepted.
HCV Elisa Method Test Kit – HCV Test Kit (Elisa Method) 4th Generation, if 4th generation kits is not available then only 3rd generation kits will be accepted.
HCV Rapid Method Test Kit – (4th Generation) 1. Long expiry of at least one year 2. Pack Size – 1 x 100 Tests 3. Test should be packed in moisture barrier pouch along with desiccant/silica pouches. 4. Flow rate complete within 15-30 mints 5. Kit should have buffer, conjugate and other accessories etc., required for running the tests. 6. Company should ISO certified.
HbsAg Elisa Method Test Kit – HbsAg Test Kit (Elisa Method) 4th Generation, if 4th generation kits is not available then only 3rd generation kits will be accepted.
HbsAg Rapid Method Test Kit – 1. Long expiry of at least one year 2. Pack Size – 1 x 50 Tests 3. Test should be packed moisture barrier pouch along with desiccant/silica pouches. 4. Flow rate – Test should be complete within 5- 10 mints 5. Kit should have all the accessories necessary for running the kit 6. The company should be ISO Certified
Anti – A (Monoclonal) 10 ml (Anti Sera should be transparent with more than one year shelf life at 2-6oC, it should give +++ agglutination at 1:256 dilution in 3-4 seconds, with A positive cells). Reagents do not show a reaction with crypt antigen.
Anti – B (Monoclonal) 10 ml (Anti Sera should be transparent with more than one year shelf life at 2-6oC, it should give +++ agglutination at 1:256 dilution in 3-4 seconds, with A positive cells). Reagents do not show a reaction with crypt antigen.
Anti – D (Monoclonal) 10 ml (Anti Sera should be transparent with more than one year shelf life at 2-6oC, it should give +++ agglutination at 1:128 dilution in 10-20 seconds, with A positive cells). Reagents do not show a reaction with crypt antigen.
A1 Lectin – 5 ml (Antisera should be transparent with 2 years shelf life at 2-6oC, it should give agglutination at titer 1:132 with A1 cells and 1:16 with A, B Cells avidity 15-20 second. No agglutination with A2 cells and O cells)
Anti H – 5 ml (Antisera should be transparent with 2 years shelf life at 2-6oC, it should give reaction with O cell at titer 1:16 with avidity of 15-20 seconds, with A1 cell at titer of 1:8 and no reaction with Oh cells)
Anti – AB (Monoclonal) – 10 ml Antisera should be transparent with more than 2 years shelf life at 2-6oC, it should give agglutination with A1 cell at titre >256 with avidity 3-4 seconds with B Cell at titre >256 with avidity 3-4 sec and with A2 cell at titre >128 with avidity 5-6.5
AHG (Anti Human Globulin) – 10 ml monospecific (Antisera should be transparent with 2 years shelf life at 2-6oC, minimum requirement for quality product of AHG, Anti IgG 1:64). There should be agglutination with O positive sensitized cells and no agglutination with O Positive unsensitized cells. There should be no prozone phenomenon.
22% Bovine Serum Albumin (Monoclonal) – 10 ml (Antisera should be transparent with more than 2 years shelf life at 2-6oC)
Medicure Pharma
S.R. Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.23 MB
3209TenderDocuments.pdf
Tender Documents • 17.69 MB
BOQ_366052.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .