Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC LOONPURIA GAON AT ROAD PANITOLA PO PANITOLA 786183 DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | 786183 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹24.9 L+₹32,109 (1.31%)Rejected-Finance | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹25.2 L+₹61,791 (2.51%)Rejected-Finance | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹25.3 L+₹73,045 (2.97%)Rejected-Finance | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹25.9 L+₹1.3 L (5.34%)Rejected-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | L5 | Rejected-Finance Higher bid value |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
26 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
REPAIR/REPLACEMENT OF EXTERNAL WATER SUPPLY SYSTEM ALONGWITH CONNECTED ALLIED SERVICES AT OUT POCKET AREA AND AT DINJAN MIL STN UNDER GE DINJAN
2022_MES_511322_1
C/8397/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMRNT
10 documents required · 10 mandatory
₹500
GE DINJAN
₹44,000
Yes
6 May 2022
2 Mar 2022
28 Mar 2022
2 Mar 2022
26 Mar 2022
15 Mar 2022
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc (for taking out and laying pipe etc) not exceeding 10 Sqm in plan and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, as in soft/loose soil complete all as specified and as directed.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Taking up 200 mm bore cast iron pipes (including all fittings) with spigot and socket end and lead joints including burning out lead joints and recovering lead complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid seperately.
All as per item No 4 here-in-before but size 150 mm bore.
All as per item No 4 here-in-before but size 100 mm bore.
All as per item No 4 here-in-before but size 80 mm bore.
Supply, laying, connection and testing 200 mm bore, ductile iron pressure pipe centrifugally cast (spun) with spigot and socket ends, class K-7 and confirming to IS 8329 - 2000 with push on rubber gasket jointing inside with cement mortar lining and outside zinc coating with finishing layer of black bitumen/blue epoxy coating duly ISI marked in any length laid in trenches complete all as specified and as directed.
All as per item No 8 here-in-before but size 150 mm bore.
All as per item No 8 here-in-before but size 100 mm bore.
All as per item No 8 here-in-before but size 80 mm bore.
S&F for 200mm bore, cast iron sluice valve both end flanged, class PN 1.6 conforming to IS -14846 (raising stem type) with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer and rubber/fiber board gasket including taking up/down old sluice valve complete all as specified and as directed.
S&F for 150mm bore, cast iron sluice valve both end flanged, class PN 1.6 conforming to IS -14846 (raising stem type) with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer and rubber/fiber board gasket including taking up/down old sluice valve complete all as specified and as directed.
S&F for 100mm bore, cast iron sluice valve both end flanged, class PN 1.6 conforming to IS -14846 (raising stem type) with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer and rubber/fiber board gasket including taking up/down old sluice valve complete all as specified and as directed.
S&F for 80mm bore, cast iron sluice valve both end flanged, class PN 1.6 conforming to IS -14846 (raising stem type) with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer and rubber/fiber board gasket including taking up/down old sluice valve complete all as specified and as directed.
S&F for 150mm bore, cast iron butter fly valve both end flanged, class PN 1.6 conforming to relevant IS lever operated including necessary jointing materials like nuts, bolt, washer and rubber/fiber board gasket including taking out existing one complete all as specified and as directed.
S&F for 100mm bore, cast iron butter fly valve both end flanged, class PN 1.6 conforming to relevant IS lever operated including necessary jointing materials like nuts, bolt, washer and rubber/fiber board gasket including taking out existing one complete all as specified and as directed.
S&F for 100 mm bore, cast iron non-return (reflux) valve, flange type with by-pass arrangement suitable for 100 mm dia water mains conforming to IS-5312 Part-I class PN 1.6 including takind down existing one complete all as specified and as directed. Make : Kalpana/Venus/Zoloto/RMCO.
Taking up or down 100 mm bore galvanised steel tubing including connections from trenches/wall/floor/ceiling etc and keeping serviceable pipes in safe custody for re-use at same site or other site complete all as specified and as directed. Note for 19 to 22 : Excavation and earth work shall be measured and paid separately under respective item.
All as per item No 19 here-in-before but size 80 mm bore.
All as per item No 19 here-in-before but size 50 mm bore.
All as per item No 19 here-in-before but size 40/32 mm bore.
Supply, laying, connection and testing, 100mm bore, Steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239(Part -2):2011 and fixtures complete laid in trenches etc complete all as specified and as directed.
Supply, laying, connection and testing, 80mm bore, Steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239(Part -2):2011 and fixtures complete laid in trenches etc complete all as specified and as directed.
Supply, laying, connection and testing, 50mm bore, Steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239(Part -2):2011 and fixtures complete laid in trenches etc complete all as specified and as directed.
Supply, laying, connection and testing, 40mm bore, Steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239(Part -2):2011 and fixtures complete laid in trenches etc complete all as specified and as directed.
Supply, laying, connection and testing, 50mm outer dia 3- layer PP-R Polypropylene random co-polymer pipes SDR 7.4 (PN16) stablised and antimi-crobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid seperately.
Supply, laying, connection and testing, 63mm outer dia 3- layer PP-R Polypropylene random co-polymer pipes SDR 7.4 (PN16) stablised and antimi-crobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid seperately.
Supply, laying, connection and testing, 90mm outer dia 3- layer PP-R Polypropylene random co-polymer pipes SDR 7.4 (PN16) stablised and antimi-crobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid seperately.
Supply, laying, connection and testing, 110mm outer dia 3- layer PP-R Polypropylene random co-polymer pipes SDR 7.4 (PN16) stablised and antimi-crobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid seperately.
M&L for making connection of PP-R distribution branch with PP-R main of size upto 40mm outer dia by providing and fixing tee including cutting and making fusion joint etc. including taking down old pipes fittings complete all as specified and as directed
M&L for making connection of PP-R distribution branch with PP-R main of size 50mm upto 90mm outer dia by providing and fixing tee including cutting and making fusion joint including taking down old pipes fittings etc. complete all as specified and as directed
M&L for making connection of PP-R distribution branch with PP-R main of size 110mm and above outer dia by providing and fixing tee including cutting and making fusion joint etc. including taking down old pipes fitting complete all as specified and as directed.
S&F in repair PP-R gate valves of Size 40 mm outer dia (brass insert) connect to PP-R pipe including taking down old unserviceable valve complete all as specified and as directed.
S&F for PP-R Gate Valves of Size 50 mm outer dia (brass insert) connect to PP-R Pipe including taking down old unserviceable valve complete all as specified and as directed.
S&F in repair, CI venturimeter having size 100 mm including taking down old one complete all as specified and as directed.
M&L for filling gland packing to control water leakage in sluice valve and centrifugal/monoblock pump sets of any capacity any type as and when required complete all as specified and as directed.
M&L for 40 mm dia gate valve cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union including taking down old unserviceable valve complete all as specified and as directed.
M&L for 50 mm dia gate valve cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union including taking down old unserviceable valve complete all as specified and as directed.
S&F for 20 mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and as directed.
Surface dressing not exceeding 15 cm deep as in soft/loose soil and rubishes to a distance not exceeding 50m including spraying pesticides (roundup or equivalent) to control the grass growth complete all as specified and directed.
Demolition of damaged brick masonry valve pit of size 1.50cm x 1.0cm x 1.0 cm (internal dimensions) including concrete work and construction of similar size valve pit with one brick thick wall in cement mortar (1:4) on 100 mm thick PCC (1:4:8) type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover made out of 40x40x6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 230x200x100mm incl provn of hinges welded with angle iron frame and MS cover 3mm thck sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Developing tube well with air compressor of suitable capacity till sand/ mud free water of potable quality to be obtained and to achieve maximum discharging capacity of 30000 GHP complete all as specified and as directed. Note : Compressor with accessories./ drive and Fuel shall be arranged by the constractor and the rates are deemed to be including in quoted rates.
S&F in replacement precast RCC pipeline route indicator duly marked/grouted and painted for 'WATER PIPE WITH DIA' of size 60x25x7.5cm with suitable size of 6mm dia reinforcement 1.0 Kg in each complete all as specified and as directed.
S&F for 4 mm dia PVC Coated chain link fencing of size 120 x 110mm mesh , made up into matressess or cages , lapped , wired and laid in position , incl closing after filling complete all as specified and as directed
M&L for plain cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in coping of poles, padestal/ pipe supports, etc including necessary form work, etc complete all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar (1:4) on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement complete all as specified and as directed.
Burning out existing lead joint in position, including removing old lead and keeping in safe custody for re-use for CI pipe 150 mm bore complete all as specified and as directed.
Burning out existing lead joint in position, including removing old lead and keeping in safe custody for re-use for CI pipe 100 mm bore complete all as specified and as directed.
Burning out existing lead joint in position, including removing old lead and keeping in safe custody for re-use for CI pipe 80 mm bore complete all as specified and as directed.
M&L for run lead joint for cast iron spigot and socket pipes and fittings 150 mm bore with new lead and other jointing materials complete all as specified and as directed.
M&L for run lead joint for cast iron spigot and socket pipes and fittings 100 mm bore with new lead and other jointing materials complete all as specified and as directed.
M&L for run lead joint for cast iron spigot and socket pipes and fittings 80 mm bore with new lead and other jointing materials omplete all as specified and as directed.
Rewinding of startar and rotor of submersibgle motor of 17.5 HP capacity with water proof insulated copper wire as per existing gauge to achieve the specified/required RPM including taking out defective submersible pump set alongwith column pipes from bore well and transporting the defective pump set from site to MES store yard for repair and re-lowering submersible pump set including column pipes with new gaskets/ washers, nuts and bolts in the existing borewell and transportation of serviceable pump set from MES store yard to borewell and install, testing, commissioning the same in existing position and making water supply and electric connection as per existing for smooth running of pump motors complete all as specified and directed by Engr-in-Charge.
S&F in repairs submersible cable of 3 core flat multistranded ( 80/0.40 dia in mm) 10 sqmm PVC insulated complete all as specifed and as directed.
S&F for automatic star delta motor starter of capacity up to 20 HP, relay max. range 17 to 25 Amp, 415 volts, 3 phase, including taking down the old/unserviceable star delta motor starter complete as specified and as directed. Make : Cat No. IHPASDPD* of Havells/L&T/CG.
M/S AUTOMOTIVE WORLD
M/s GANDHESWAR PHUKAN
FREEZCON
R.D.CONSTRUCTION
Bimal Trading Company
M H KHAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .