GE 872 EWS, C/O 99 APO
REPAIRS TO LT EXTERNAL ELECTRICAL INSTALLATIONS AND REPAIRS/MAINT AND SERVICING OF GENERATOR SETS, LT PANELS AND EARTHING AT LIKABALI MIL STN UNDER GE 872 EWS(8724/E8)
2019_MES_293899_2
C/8724/T-24/E8
Open Tender
Civil Works
Works
243 days
LIKABALI
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹30,000
Yes
23 Jan 2020
7 Dec 2019
27 Dec 2019
7 Dec 2019
26 Dec 2019
16 Dec 2019
7 Dec 2019 - 11 Dec 2019
Amount
Dismantling unserviceable LT Steel Tubular Pole of any description and any size including Demolition Cement Concrete (if required on Ground) and Made Good disturbed Ground, complete all as specified and as directed. NOTE : Unserviceable Pole will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earthwork, Demolition Cement Concrete, etc. will not be Measured and Paid separately.
Dismantling Cross Arms, Mild Steel Channel, Angle Section, Flat Iron, Mild Steel Rod, etc., complete all as specified and as directed.
Taking down unserviceable/rusted GI Earth Wire, Cradles Guards of any size and shape at any Position from LT Electric Poles of any size and capacity, complete all as specified and as directed.
Taking down ACSR Conductor including Line Spacers of OH Electric Lines from LT Electric Poles of any size and capacity, complete all as specified and as directed.
Dismantling Stay Assembly complete of any description, complete all as specified and as directed. NOTE : Unserviceable Stay Assembly will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earth Works, Demolition of Cement Concrete, etc. will not be Measured & Paid separately.
Disconnecting & Taking down/out unserviceable LT Cable of any size and any description from Trenches, Floors, Walls, GI Pipes, etc. incuding Serviceable (if any) Cables, Bricks/Cable Protection Cover, etc. keep in Safe Custody for re-use, complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid under appropriate Items.
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Cable, Electric Pole, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth exc. 1.50 Metre but not exc. 3.00 Metre for Electric Pole, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps along the Route of the Cable Line with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point in Soil, complete all as specified and as directed.
Drilling/Making Hole (Horizontally) under Roads/ Hardstanding, etc. by any means suitable for passing GI Tubing 40mm to 80mm bore (dia), complete all as specified and as directed.
M&L Cutting Existing Road not exc. 1.50 Metre in depth and not exc. 1.50 Metre wide including Making Good the same to match the Original Surface level with Cement Concrete 1:3:6 (40mm graded stone aggregates) after laying of Cables, Well Ramming and leveling in layers, etc., complete all as specified and as directed. NOTE : Cement Concrete will be Measured and Paid separtely under appropriate Item.
M&L Broken Stone Aggregates of size 20mm to 40mm grade, laid surrounding the LT Panels, LT Structures, etc., levelled and hand ramming, complete all as specified and as directed.
M&L Continuous Brick Edging with burnt Clay Bricks of Sub-class 'B' with width Equal to the width of Brick, laid dry on End vertically, complete all as specified and as directed.
M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Copping of Electric Poles, etc., weathering slightly rounded or chamfered angle and throating, finishing all Exposed Faces of Concrete including necessary Formwork, complete all as specified and as directed.
M&L Steel Tubular Swaged Pole Type 410 SP-31 (9.0 Metre long) complete with Mild Steel Base Plate, Finial Taper Plug, Bolts, Nuts & Screws, etc. as specified including One coat Aluminium Paint over One Coat of Red Oxide Zinc Chrome Primer, providing 3 No. Band/ Strap with Paint Black/ Yellow Colour 300mm apart from Plinth Block and numbering of Pole/ Painting embedded portion of Pole with One coat of Bituminous Paint, complete all as specified and as directed. NOTE : Necessary Earth Work & PCC will be Measured and Paid separately under relevent Items.
M&L Cross Arms, Bracings, Supports, Clamps and Back Plates, fabricated from Structural Steel Sections including Nuts, Bolts, Washers, etc., welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated or directed and applying Two coats of Aluminium Paint over a coat of Red Oxide Zinc Chromium Primer after preparation of Surfaces, complete all as specified and as directed.
S&F Insulator Pin type, 100mm height, 65mm dia for 1100 Volt grade, Porcelain, Vitreous, white, brown or green including One Galvanised Mild Steel Spindle Two Galvanised Iron Washer and One Galvanised Iron Nut including Taking down unserviceable Insulator, complete all as specified and as directed.
S&F Insulator Shackle type, Porcelain, Vitreious, white brown or green of size 100mm High & 115mm dia including Galvanised Mild Steel Straps of Section 31x5.0mm, 14mm dia Insulator Bolts, Nuts, Washer, etc. for Working Pressure 1100 Volt grade including Taking down unserviceable Insulator, complete all as specified and as directed.
S&F Insulator Loop type, Small in size, Vitreous Porcelain, white, borwn or green with Overall Dimensions 65x90mm, Clearance of Hole 16mm 1100 Volt grade including Taking down unserviceable Insulator, complete all as specified and as directed.
M&L Galvanised Iron Wire 4.0mm dia (8 SWG) as Continuous Earth Wire, Guards and Cradles (hexagonal/rectangular), etc. and binding with and including GI Binding Wire 1.6mm dia, complete all as specified and as directed.
M&L ACSR Conductor of any size for LT Over Head Line including Stringing Conductor fixed on Poles and binding with Aluminium Binding Wire, etc., complete all as specified and as directed. NOTE : Sizes of Conductor will be as per Site requirement as directed by Engineer-in-Charge.
M&L Restretching, Tightening & Fixing of ACSR Conductor of any size on LT Electric Poles including necessary Aluminium Binding Wire, Connectors, PVC Sleeves for Jumper, etc. complete all as specified and as directed. NOTE :- (a) The above Work includes Cleaning/Tremming of Tree Branches of any dia falling around the ACSR Conductors. (b) One Length shall be measured for complete Span comprising of any numbers of ACSR Conductor(s) & GI Wire(s).
S&F Jumper made out of ACSR Conductor of suitable size and binding with Aluminium Binding Wire, properly on the existing LT OH Line Taking down unserviceable Jumper, complete all as specified and as directed.
S&F PVC Fibre Separator for LT Line 1100 Volt Over Head Conductor 2/3/4-Wire System for Horizontal Spacing of Conductor complete with Nut and Bolts minimum 2 No. to prevent the Lines Touching Each Other on Heavy Winds as a Preventive Arrangement to the Existing System, complete all as specified and as directed.
S&F PVC Fibre Separator for LT Line 1100 Volt Over Head Conductor 5/6-Wire System for Horizontal Spacing of Conductor complete with Nut and Bolts minimum 2 No. to prevent the Lines Touching Each Other on Heavy Winds as a Preventive Arrangement to the Existing System, complete all as specified and as directed.
M&L Stay Assembly complete with all Accessories such as Mild Steel Galvanised Flat Iron Stay Clamp, Galvanised Stay Wire 7/4.0mm stranded, One Insulator Loop type Porcelain Vitreous (white, brown or green) Overall Dimensions 90x140mm and Clearance of Hole 25.5mm, Stay Grips, Mild Steel Galvanised Stay Bow, Thimbles Galvanised steel 14mm dia & 400mm long, 20mm dia Mild Steel Galvanised Stay Rod 1900mm long and Mild Steel Galvanised Stay Plate of size 300x300x6.0mm all as shown in Electrical Plate No. 1 of MES Schedule Part-I, complete all as specified and as directed. NOTE : Necessary Earth Work, Cement Concrete, etc. will be Measured and Paid separately under relevant Items.
S&F Danger Notice Plate of size 25x20 Cm for LT, made of 1.6 mm thick Mild Steel Sheet, Vitreous Enamelled White, Letters, Figures and Conventional Skull & Bones in Signal Red Colour and fixed with Mild Steel Vlamps, Bolts & Nuts of appoved size including Taking down unserviceable GOD, complete all as specified and as directed.
S&F Aluminium Conductor Cable of size 10 Sqmm, 1100 Volt grade, heavy duty, PVC insulated, served with inner sheathing of PVC Tape and overall PVC sheathed in Service Connections suspended by insulating Hangers not more than 1.0 Metre apart including 4.0mm Suspension Wire, One Twin Core Cable, Flat or Circular including Taking down unserviceable Service Connection Cable, complete all as specified and as directed.
M&L Trimming/Cutting of Tree Branches of any girth/size and Clearing of LT OH Lines (any Nos. of ACSR Conductors, Earth Wire, etc.) upto 3.0 Metre distance, Removing Tree Branches from the Sites, complete all as specified and as directed.
M&L Painting LT Pre-stressed Concrete Pole including Cross Arms, Channel, Flat Iron Clamps, etc. with Two coats of Cement Based Paints and Numbering of Code in letter size not less then 50mm in Black Paints and Painting of Pole with Strips 300mm high (5 Nos.) around the Pole with Two different Colour Synthetic Enamelled Paint for Pole 7.5 Metre height above Ground Level, complete all as specified and as directed.
M&L Painting LT Steel Tubular Pole including Cross Arms, Channel, Flat Iron Clamps, etc. with One coat of Aluminium Paints and Numbering of Code in letter size not less then 50mm in Black Paints and Painting of Pole with Strips 300mm high (5 Nos.) around the Pole with Two different Colour Synthetic Enamelled Paint for Pole 7.5 Metre height above Ground Level, complete all as specified and as directed.
M&L XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 10 Sqmm, 2 Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth works, Sand Cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 25 Sqmm, 4 Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth works, Sand Cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 35 Sqmm, 3½ Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth works, Sand Cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 240 Sqmm, 3½ Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth works, Sand Cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.
Taking down unserviceable LT Cable Cross-sectional area 6 Sqmm 2 Core to 16 Sqmm 2 Core, 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as ordered, Relaying/ Re-fixing the Cable after rectification, complete all as specified and as directed. NOTE : Necessary Earth works, Sand Cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.
Taking down unserviceable LT Cable Cross-sectional area 10 Sqmm 4 Core to 25 Sqmm 4 Core, 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as ordered, Relaying/ Re-fixing the Cable after rectification, complete all as specified and as directed. NOTE : Necessary Earth works, Sand Cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.
Taking down unserviceable LT Cable Cross-sectional area 35 Sqmm 3½ Core to 70 Sqmm 3½ Core, 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as ordered, Relaying/ Re-fixing the Cable after rectification, complete all as specified and as directed. NOTE : Necessary Earth works, Sand Cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.
Taking down unserviceable LT Cable Cross-sectional area 120 Sqmm 3½ Core to 185 Sqmm 3½ Core, 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as ordered, Relaying/ Re-fixing the Cable after rectification, complete all as specified and as directed. NOTE : Necessary Earth works, Sand Cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.
Taking down unserviceable LT Cable Cross-sectional area 240 Sqmm 3½ Core to 300 Sqmm 3½ Core, 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as ordered, Relaying/ Re-fixing the Cable after rectification, complete all as specified and as directed. NOTE : Necessary Earth works, Sand Cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
Supply & Laying Unreinforced Pre-cast Concrete Cable Cover of size 250x150x40mm thick, Class LV, Type 1, Flat, Concrete grade M-20 minimum, complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 40mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 50mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 80mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
S&F MCCB 100 Amp 3 Pole, 25 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/out unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 125 Amp 3 Pole, 25 kA, 415 Volt, 50 Hz, SKB-1 including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/out unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 250 Amp 3 Pole, 35 kA, 415 Volt, 50 Hz, DN2-250D including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/out unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 63 Amp 4 Pole, 25 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/out unserviceable MCCB, complete all as specified and as directed,
S&F MCCB 200 Amp 4 Pole, 35 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/out unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 315 Amp 4 Pole, 50 kA, 415 Volt, 50 Hz, SKB-4 including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/out unserviceable MCCB, complete all as specified and as directed.
S&F On Load Change Over Switch (Front Operated) Open Execution, 100 Amp rating, 4 Pole, 415 Volt and connecting up including Taking down/out unserviceable Change Over Switch, complete all as specified and as directed.
M&L Factory made Double Door Sheet Metal Encloser, Totally Enclosed, made out of 16 SWG CRCA Sheet, having Powder coated Weather Proof mounting on 40x40x6.0mm Mild Steel Angle Iron Frame, Out Door type, Front Opening Shutter with proper Locking Arrangements, complete with Fixing Arrangements with Mild Steel Nuts, Bolts for grouting as required at Site including Taking down unserviceable/rusted Sheet Metal Encloser/ Bus-bar, comprising of with the followings :- (a) Copper Bus-bar 4 Strip 200 Amp, 415 Volt - 01 Set (b) Space for fixing MCCB 100 Amp, 4 Pole, 35 kA, 415 Volt - 03 No. (c) Space for fixing MCCB 160 Amp, 4 Pole, 35 kA, 415 Volt - 01 No.
M&L Repairing broken Door, Locking Arrangements, Hinges, etc. of LT Panel/ Feeder Pillar/ Pole Box, Indoor/ Outdoor type of any size, necessary welding, drilling as reqiured, Replacing Door, Locking Arrangements, Hinges, etc. if ordered, complete all as specified and as directed.
M&L Cleaning, Scraping of Exposed Surfaces of LT Panel/ Feeder Pillar /Pole Box, Indoor/ Outdoor Type and applying One coat of Synthetic Enamel Paint (Paint & Shade as approved) with Spray Painting Machine including Writing MES No. and Machine No. with Black Paint, Letters 50mm High and 15mm Wide, complete all as specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
M&L Earthing with Copper Earth Plate Electrode 600x600x3.15mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Copper Earth Strip of size 20x3.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
M&L Repairs/Maint & Servicing of DG Set 30 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed comprising with the following Works:- (a) Replacement of all Filters, Lubricating Oil. (b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connections, Engine Control Wirings. (c) Carry out necessary Tappet Clearance, if required. (d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins. (e) Check functioning of Changing Alternator. (f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required. (g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required. (h) The Governor shall be Checked and Tuned for Proper Functioning. (j) Check for Leaks if any and shall be rectified. (k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues. NOTE : All Spares and Consumable Items such as Distilled Water, Lube Oil, Grease, Filters and Other Spare Parts (Quantitites mentioned here-in-after are Provisional only) are will be Measured & Paid as 'Supply only' under appropriate Items.
Supply only Air Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only AVR (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only Controler Model No. KG934 (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only V Belt (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
M&L Repairs/Maint & Servicing of DG Set 62.5 KVA capacity of MAKE : KIRLOSKAR/ ASHOK LEYLAND, complete all as specified and as directed comprising with the following Works:- (a) Replacement of all Filters, Lubricating Oil. (b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connections, Engine Control Wirings. (c) Carry out necessary Tappet Clearance, if required. (d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins. (e) Check functioning of Changing Alternator. (f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required. (g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required. (h) The Governor shall be Checked and Tuned for Proper Functioning. (j) Check for Leaks if any and shall be rectified. (k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues. NOTE : All Spares and Consumable Items such as Distilled Water, Lube Oil, Grease, Filters and Other Spare Parts (Quantitites mentioned here-in-after are Provisional only) are will be Measured & Paid as 'Supply only' under appropriate Items.
Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only AVR (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Controler Model No. KG934/GC 1202 (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only V Belt (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
M&L Repairs/Maint & Servicing of DG Set 125 KVA capacity of MAKE : KIRLOSKAR/ ASHOK LEYLAND/KIRLOSKAR GREEN, complete all as specified and as directed comprising with the following Works:- (a) Replacement of all Filters, Lubricating Oil. (b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connections, Engine Control Wirings. (c) Carry out necessary Tappet Clearance, if required. (d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins. (e) Check functioning of Changing Alternator. (f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required. (g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required. (h) The Governor shall be Checked and Tuned for Proper Functioning. (j) Check for Leaks if any and shall be rectified. (k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues. NOTE : All Spares and Consumable Items such as Distilled Water, Lube Oil, Grease, Filters and Other Spare Parts (Quantitites mentioned here-in-after are Provisional only) are will be Measured & Paid as 'Supply only' under appropriate Items.
Supply only Air Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 125 KVA capacity, complete all as specified and as directed.
Supply only AVR (as per existing/ as approved) suitable for DG Set 125 KVA capacity, complete all as specified and as directed.
Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 125 KVA capacity, complete all as specified and as directed.
Supply only Controler Model No. KG934 (as per existing/ as approved) suitable for DG Set 125 KVA capacity, complete all as specified and as directed.
Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 125 KVA capacity, complete all as specified and as directed.
Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 125 KVA capacity, complete all as specified and as directed.
Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 125 KVA capacity, complete all as specified and as directed.
Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 125 KVA capacity, complete all as specified and as directed.
Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 125 KVA capacity, complete all as specified and as directed.
Supply only V Belt (as per existing/ as approved) suitable for DG Set 125 KVA capacity, complete all as specified and as directed.
M&L Repairs/Maint & Servicing of DG Set 160 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed comprising with the following Works:- (a) Replacement of all Filters, Lubricating Oil. (b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connections, Engine Control Wirings. (c) Carry out necessary Tappet Clearance, if required. (d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins. (e) Check functioning of Changing Alternator. (f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required. (g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required. (h) The Governor shall be Checked and Tuned for Proper Functioning. (j) Check for Leaks if any and shall be rectified. (k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues. NOTE : All Spares and Consumable Items such as Distilled Water, Lube Oil, Grease, Filters and Other Spare Parts (Quantitites mentioned here-in-after are Provisional only) are will be Measured & Paid as 'Supply only' under appropriate Items.
Supply only Air Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 160 KVA capacity, complete all as specified and as directed.
Supply only AVR (as per existing/ as approved) suitable for DG Set 160 KVA capacity, complete all as specified and as directed.
Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 160 KVA capacity, complete all as specified and as directed.
Supply only Controler Model No. KG934 (as per existing/ as approved) suitable for DG Set 160 KVA capacity, complete all as specified and as directed.
Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 160 KVA capacity, complete all as specified and as directed.
Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 160 KVA capacity, complete all as specified and as directed.
Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 160 KVA capacity, complete all as specified and as directed.
Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 160 KVA capacity, complete all as specified and as directed.
Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 160 KVA capacity, complete all as specified and as directed.
Supply only V Belt (as per existing/ as approved) suitable for DG Set 160 KVA capacity, complete all as specified and as directed.
M&L Asbestos Rope (as per existing/ as approved) including Taking down/out unserviceable Asbestos Rope, complete all as specified and as directed.
M&L Battery Charger 100 AH to 150 AH Capacity, Digital and suitable for charging 12 Volt Battery. providing all Electrical Connection including Taking down/out unserviceable Battery Charger, complete all as specified and as directed. MAKE : POWERTRON, Model No. Pipl-1220bc Digital
M&L Battery Terminal of Copper/Brass (as per existing/ as approved) and connected including Taking down/out unserviceable Battery Terminal, complete all as specified and as directed.
S&F Toggle Switch 3-way, Double Pole (as per existing/ as approved) and connected including Taking down/out unserviceable Toggle Switch, complete all as specified and as directed.
M&L Cleaning of Radiator of any capacity after Opening all Nuts, Bolts, etc. by dismounting, Re-mounting after Cleaning with Chemical and Tightening of Nuts, Bolts, etc. including Straightening of Radiator Fins with suitable Tools, complete all as specified and as directed.
M&L Repairing & Cleaning of Diesel Tank with suitable Materials after disconnecting Fuel Line, Opening of all Nuts, Bolts, etc., Re-fixing the same after satisfactory Repairing including necessary Welding (if required), etc., complete all as specified and as directed.
Supply & Filling Coolant for Radiators as approved), complete all as specified and as directed. MAKE : KIRLOSKAR or as approved by GE
Supply & Filling Engine Oil 20 W/ 40 Grade as approved), complete all as specified and as directed. MAKE : CASTROL CRB Plus or as approved by GE
M/s HALDER ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .