Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹32.6 L
EMD Value
₹65,500
Closing Date
27 Aug 2024, 2:00 pmClosed
Executive Engineer, Electric Division Kathua
Office of the XEN, Electric Division Kathua
Providing 3 Phase 4 Wire Electricity connection to the newly constructed Plastic Management Unit in respect of Sub Division Kathua, Ramkot and Billawar of Electric Division Kathua on Turnkey Basis
2024_PDD_255413_1
KED/63 of 2024-25 Dated 05.08.2024
Open Tender
Electrical Works
Turn-key
45 days
Kathua Mandli Ramkot
Please refer tender documents
4 documents required · 4 mandatory
₹1,000
Executive Engineer, Electric Division Kathua
₹65,500
Yes
Office of the XEN, Electric Division Kathua
29 Oct 2024
5 Aug 2024
29 Aug 2024
5 Aug 2024
27 Aug 2024
5 Aug 2024
5 Aug 2024 - 13 Aug 2024
13 Aug 2024
Amount
Creation of 100KVA Sub Station for providing of non functional Plastic Waste Management Unit Kathua in respect of JPDCL Electric Sub Division Kathua of Electric Division Kathua on Turnkey Basis (Location shall be identified by the Sub Division)
100KVA, 11/0.433-0.250KV;50Hz, AI wound Distribution Transformer of latest Energy Efficiency Level-2 (new), ISI 180 Part-I, 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4mtrs, suitable cable of ratings (Aluminium Wound upto 200KVA, Copper Wound for 250KVA or Higher KVA ratings).
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11KV Horn Gap Fuse Set 3 Phase 200A
185mm² (2 Ckt) Cable,1.1KV Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole(PCC WL-300Kg))
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedege connectors /PG clamps
Danger plate with clamps
GI Barbed wire for anti climbing
3 Ph 4 Wire Trivector meter with CT
Cement bottoming 1:2:4 mix as per REC standards .5 Cum/pole
Sundary items like Aluminium Lugs, Jumpers, binding tape
Erection of HT line on 9 Mtrs. PCC poles with ACSR Weasel Conductor for providing of non functional Plastic Waste Management Unit Kathua in respect of JPDCL Electric Sub Division Kathua of Electric Division Kathua on Turnkey Basis (Location shall be identified by the Sub Division)
9 Mtr. Long Pole(PCC WL-300Kg))
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel x-arm includingclaps and braces
30 mm² ACSR Weasel Conductor
PG Clamps for ACSR weasel conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamp
Anti Climbing Devices with clamps
Earthing complete by GI Pipe 40mm dia or GI Rod 20mm, 2.5Mtrs long through GI Strip
Stone Pad (300mm x 300mm x 75mm)
Aluminium Jointing Sleeves
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Erection of LT line on 8 Mtrs. PCC poles with ACSR Weasel Conductor 47Mtr span on 3Phase 4 wire for providing of non functional Plastic Waste Management Unit Kathua in respect of JPDCL Electric Sub Division Kathua of Electric Division Kathua on Turnkey Basis (Location shall be identified by the Sub Division)
8 Mtr. Long pole (WL-3200KG)
GI U-Clamp for Shackle insulators
Shackle insulator 16 KN
30 mm² ACSR Weasel Conductor
Galvanized Nuts and Bolts
Danger plates with clamps
Anti Climbing Device with Clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Stone Pad (300mm x 300mm x 75mm)
Aluminium Jointing Sleeves
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Creation of 100KVA Sub Station for providing of non functional Plastic Waste Management Unit Mandli in respect of JPDCL Electric Sub Division Ramkot of Electric Division Kathua on Turnkey Basis (Location shall be identified by the Sub Division)
100 KVA, 11/0.433-0.250KV; 50HZ AI wound distribution transformer of latest energy efficiency level-2 (new), ISI 180 part-I, 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4mtrs, suitable cable of ratings (Aluminium Wound upto 200KVA, Copper wound for 250KVA or Higher KVA ratings)
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185 mm² (2Ckt) Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole(ST 410 SP33)
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedege connectors /PG clamps
Danger plate with clamps
GI Barbed wire for anti climbing
3 Ph 4 Wire Trivector meter with CT
Cement bottoming 1:2:4 mix as per REC standards .5 Cum/pole
Painting of poles Red Oxide
Painting of poles Aluminum Paint
Sundary items like Aluminium Lugs, Jumpers, binding tape
Erection of HT line on 9 Mtrs. ST Poles with ACSR Weasel Conductor for providing of non functional Plastic Waste Management Unit Mandli in respect of JPDCL Electric Sub Division Ramkot of Electric Division Kathua on Turnkey Basis (Location shall be identified by the Sub Division)
9 Mtr. Long Pole(ST-410 SP33)
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel x-arm includingclaps and braces
30 mm² ACSR Weasel Conductor
PG Clamps for ACSR weasel conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamp
Anti Climbing Devices with clamps
Red oxide paint
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standard 0.5 CUM per pole
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Aluminium Jointing Sleeves
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Erection of LT line on 8 Mtrs. ST Poles with ACSR Weasel Conductor on 3Phase 4 wire for providing of non functional Plastic Waste Management Unit Mandli in respect of JPDCL Electric Sub Division Ramkot of Electric Division Kathua on Turnkey Basis (Location shall be identified by the Sub Division)
8 Mtr. Long pole (ST 410 SP15)
GI U-Clamp for Shackle insulators
Shackle insulator 16 KN
30 mm² ACSR Weasel Conductor
Galvanized Nuts and Bolts
Danger plates with clamps
Anti Climbing Device with Clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Red oxide paint
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standard 0.5 CUM per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Aluminium Jointing Sleeves
Creation of 100KVA Sub Station for providing of non functional Plastic Waste Management Unit Billawar in respect of JPDCL Electric Sub Division Billawar of Electric Division Kathua on Turnkey Basis (Location shall be identified by the Sub Division)
100 KVA, 11/0.433-0.250KV; 50HZ AI wound distribution transformer of latest energy efficiency level-2 (new), ISI 180 part-I, 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4mtrs, suitable cable of ratings (Aluminium Wound upto 200KVA, Copper wound for 250KVA or Higher KVA ratings)
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185 mm² (2Ckt) Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole(ST 410 SP33)
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedege connectors /PG clamps
Danger plate with clamps
GI Barbed wire for anti climbing
3 Ph 4 Wire Trivector meter with CT
Cement bottoming 1:2:4 mix as per REC standards .5 Cum/pole
Painting of poles Red Oxide
Painting of poles Aluminum Paint
Sundary items like Aluminium Lugs, Jumpers, binding tape
Erection of HT line on 9 Mtrs. ST Poles with ACSR Weasel Conductor for providing of non functional Plastic Waste Management Unit Billawar in respect of JPDCL Electric Sub Division Billawar of Electric Division Kathua on Turnkey Basis (Location shall be identified by the Sub Division)
9 Mtr. Long Pole(ST-410 SP33)
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel x-arm includingclaps and braces
30 mm² ACSR Weasel Conductor
PG Clamps for ACSR weasel conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamp
Anti Climbing Devices with clamps
Red oxide paint
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standard 0.5 CUM per pole
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Aluminium Jointing Sleeves
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Erection of LT line on 8 Mtrs. ST Poles with ACSR Weasel Conductor on 3Phase 4 wire for providing of non functional Plastic Waste Management Unit Billawar in respect of JPDCL Electric Sub Division Billawar of Electric Division Kathua on Turnkey Basis (Location shall be identified by the Sub Division)
8 Mtr. Long pole (ST 410 SP15)
GI U-Clamp for Shackle insulators
Shackle insulator 16 KN
30 mm² ACSR Weasel Conductor
Galvanized Nuts and Bolts
Danger plates with clamps
Anti Climbing Device with Clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Red oxide paint
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standard 0.5 CUM per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Aluminium Jointing Sleeves
I.CON ELECTRICALS
COUNTRY CONSTRUCTION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .