| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC | L1 | Accepted-AOC aoc | |
| 2 | L2₹18.0 L+₹7,692 (0.43%)Rejected-Finance 5 21 SADAR BAZAR SAUGOR MP 470001 | SAUGOR | SAGAR | MP | 470001 | L2 | Rejected-Finance 2nd lowest bid | |
| 3 | L3₹18.5 L+₹57,812 (3.23%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest bid | |
| 4 | L4₹18.5 L+₹58,505 (3.27%)Rejected-Finance | L4 | Rejected-Finance 4th lowest bid |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
16 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SAUGOR
GE SAUGOR
REPAIR, MAINT OF CERTAIN BR WORKS OF MD ACCN OF HAWK HILL UNDER GE SAUGOR
2022_MES_524312_1
GE/SGR/TOK-18 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
SAUGOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER SAUGOR
₹40,000
Yes
22 Jun 2022
20 May 2022
18 Jun 2022
20 May 2022
16 Jun 2022
4 Jun 2022
60 days
Amount
Taking down cement plaster on brick or stone walls including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and directed
Demolition of RCC in precast cover slab any thicknes (reinforced) complete all as specified and directed
Dismantling of floor, hearth or wall tiles / terrazo including cement mortar bedding (but not backing),removal servicable tiles to store and rubbish off the premises complete all as specified and directed
Demolition of cement concrete in ground floors and pavings not exc 15cm below or above ground floor complete all as specified and directed.
Taking down chowkhats or frames with shutters (w/o taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and directed
Taking down chowkats or frames with shutters (w/o taking of shutters from the frame) exc 1.5 but not exc 4 Sqm each complete all as specified and directed.
Taking down shutters of any description not exc 1sqm each complete all as specified and directed
Taking down shutters of any description exc 1sqm but not exc 2sqm each complete all as specified and directed
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion & making good disturbed ground embedded in concrete, brick work, masonry, etc., complete all as specified and directed
M&L for PCC 1:2:4, type B2 (using 40 mm graded stone aggregates) as in foundations, filling and mass-concretecomplete all as specified and directed
M&L for brickwork with subclass 'B' bricks, straright or corved on plan exc 6m mean radius built in cement mortar 1:6 including demolition of brick work or rubbled stone masonry including all qoins arches , pillars etc built in cement mortar complete all as specified and directed.
M&L for cutting chases, pinning in, in brick wall making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring etc. and making good, in cement mortor 1:3 cutting not exceeding 10cm girth complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia, and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and directed.
M&L for mild steel TMT bars 6mm to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and directed..
M&L for precast reinforced cement concrete type B1 (1:2:4) using 20 mm graded aggregate set in CM(1:4) in landings,kitchen platform, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed. .
M&L for non Skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles laid over and including 15mm thick screed bed or beding layer in cement mortar in CM(1:6) complete all as specified and directed.
M&L for coloured anti skid ceremic tiles 7 to 8 mm thick area of each tiles exc. 0.11 sqm and not exc. 0.18 sqm (400 x 400 mm joint free (rectified) ) as in floor set & jointed in neat cement slurry and pointed in white /coloured cement to match tiles laid over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
All as per Srl item No. 17 above but in dado / skirting laid over and including 10 mm thick rendering in CM (1:4) -ditto-
M&L for coloured non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles laid over and including 15mm thick screed in CM(1:6) complete all as specified and directed.
All as per Srl item No. 19 above but in dado / skirting laid over and including 10 mm thick rendering in CM (1:4) -ditto-
M&L for glazed ceramic tiles of size 600mmx 300mm x 7mm thick,(joint free (rectified)) coloured, on vertical surfaces such as skirting/dado etc, set and jointed in neat cement slurry and pointed in white/ coloured cement to match tiles laid over and including 15 mm thick rendering in CM 1:4 complete all as specified and directed. .
M&L for 16mm to 18mm thick Granite of any shade ( table rubbed and polished ) in steps, jambs, pillars, windowcills, cooking plateforms and like in cement mortor 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match shade of the slabs complete all as specified and directed
M&L for rounding/ chamferring to edges of stone slabss one edge , such as in steps , cooking plateform and other similar situations complete all as specified and directed
M&L for machine pressed precast concrete interlocking paver block glossy finished chemically treated any shape and size confirming to IS-15658-2006 size of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 30mm to 50mm stone dust cushioning including demolition of stone sett paving of any description or thickness laid, bedded and pointed in any mortar complete all as specified and directed..
M&L for 25 mm thick PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in sub base of floor to receive tiles or Kota stone complete all as specified and directed
M&L for plain cement concrete type C-2, 1:3:6 (using 20 mm graded stone aggregates) as in sub base complete all as specified and directed
M&L for plain cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregates) as in foundation filling and mass concrete all as specified and directed
M&L for rendering 20 mm thick cement plaster in cement mortar 1:6 on stone masonary / other than fair finished surfaces of brick wall finishing the surfaces even and smooth without using extra cement complete all as specified and directed
M & L for rendering 15mm thick cement plaster on wall in cement mortar 1:6 on brick wall / concrete surfaces of finishing the surfaces even and smooth without using extra cement complete all as specified and directed
M&L for rendering 15mm thick on stone masonry surfaces or surface other than fair face of brickwork in CM (1:4) including water proofing compound @ 2% by wt of cement complete all as specified and directed. Note:-WPC shall be measured and paid separately
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:3) in ceiling complete all as specified and directed
M&L for cement concrete 1:2:4, type B0 ( using 12.5 mm graded stone aggregates ) as in coping , apex stone , bed plate , kerbs including weathering , slightly rounded or chamferred angles and throating and incl. necessary form work complete all as specified and directed
M&L for preparing the new plastered surfaces and applying three coats of white wash on walls complete all as specified and directed
M&L for applying three coats of white wash on new ceiling surface including preparation of surface complete all as specified and directed.
M&L for applying two coats of Acrylic Distemper , white or tinted on new wall surface including preparation of surface complete all as specified and directed
M&L for applying two coats of Acrylic Distemper, white or tinted on old wall surface including preparation of surface complete all as specified and directed.
M&L for applying two coats of exterior emulsion anti fungal paint (ACE or equivalent make as approved by GE) on newly platered surface of walls incl preparation of surfaces with one coat of primer complete all as specified and directed
M&L for second class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed
M&L for second class hard-wood clean sawn straight scantling area exc. 13 & not exc. 25 sqcm each for fixing to existing chowkats with nails complete all as specified and directed
S&F 105 mm X 60 mm size pressed steel frames for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including one shop coat of red oxide primer including cutting holes and making good in P:C:C 1.2.4 type B-1 using 20 mm graded stone aggregate and M&L PCC 1:3:6 type C-0 using 12.5 mm graded store aggregate for filling in pressed steel frame complete all as specified and as directed
ALL as per Srl item No 40 above but size 125mm x60mm -ditto-
S&F steel window with side hung shutters with glazing bars devetailed or welded, fixed on and including pressed steel frame of size 80mm x 40mm x 1.25mm thick CRCA profile section with box type hinges, steel handle, steel peg stay etc and M&L PCC 1:3:6 type C-0 using 12.5 mm graded store aggregate for filling in pressed steel frame complete all as specified and directed.
S&F steel window with side hung shutters without glazing bars and fixed to steel frame complete all as specified and directed
S&F fixed type ventilators aluminium powder coated of frame size 50.80X 25.40mm,1.5 mm thick half portion will be fixed with 4mm thick frosted glass and half portion will be fixed with louvers with 4mm thick frosted glass with rubber gasket and aluminium beading ,aluminium grill with fixing arrangement (wt. of grill not less then 2.50 kg/sqm),aluminium wire mess 0.45 mm dia to be fixed over louvers portion only including necessary cutting holes on wall and fixing arrangements complete all as directed by Engr-in- Charge (Al. section thickness 1.50 mm }
S&F aluminium windows sliding type three track powder coated consisting of frame bottom with gutter of size min 92.34 X 39 mm,sideand top of size min 92.34X29.70, shutters vertical 39X20 mm,shutter top &bottom of size min 20X39 mm ,shutter interlock min size 39X20 mm with rollers and conceled locking arrangements with 4 mm thick tinted glass with rubber gasket,brush and aluminium beading , ,aluminium grill with fixing arrangement (wt. of grill not less then 2.50 kg/sqm),aluminium wire mess 0.45 mm dia etc including necessary cutting holes on wall and floor and confirming to IS complete all as directed by Engr-in- Charge (Al. section thickness 1.50 mm }
S&F 35 mm thick flush shutters, solid core construction, with block board core and plywood facepanels, commercial type on both sides, complete all as specified and directed(with double or single shutter complete all as specified and directed
S&F second class hardwood factory made glazed and skeleton shutters 35 mm thick open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chemfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, cla-use 8.24 (a); for doors supplied and fitted to chowkats complete all as specified and directed.
S&F solid PVC door frame of size 50mmX47mm made out of 5mm single side prelam PVC sheet used instead of plain colour PVC sheet (edges will be painted to match with prelam sheet) reinforced with MS square tube complete all as specified and directed
S&F factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6mm raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm prelam PVC sheet on back face complete all as specified and directed
S&F galvanised mild steel wire cloth, 0.46 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F in repairs galvanised mild steel wire cloth, 0.46 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F second class hardwood beads, straight (any size) for glazed or gauzed joinery, renewed, including mitres etc and removing old beads complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
M&L for preparation of new wooden surfaces of any description not exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed
S&F mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200 mm complete all as specified and directed
S&F Aluminium handles 150mm size, cast type, anodised complete all as specified and directed
S&F Mild steel pressed handles,150mm oval type, stove enamelled black complete all as specified and directed
S&F Aluminium, anodised, barrel tower bolts 150mm long of extruded section complete all as specified and directed
S&F mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, length of bolt 300 mm complete all as specified and directed
S&F Butt hinges of 100 mm size, Medium weight, cold rolled mild steel and fixed complete all as specified and directed.
S&F 100mm Butt hinges, extruded aluminium aloy with galvanised mild steel hinge pin, anodised and fixed complete all as specified and directed
S&F door stopper of aluminium alloy body and tongue 150 mm long , anodised fixed in door with screws complete all as specified and directed
S&F 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed
M&L for cutting holes in brick walls in cement mortar or cement lime mortar and stone wall built in lime mortar for inserting holdfasts in exc. One brick but not exc. two brick wall and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
S&F framed work such as grills gratings, sunshed cover fixed with nut bolts incl,cutting drilling holes etc., with ends of bars shouldered and/ or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed baluster, walk ways, railings, framedwork or water tanks and similar work conforming to Fe 290 Gde E 165 complete all as specified and directed.
Hacking out old broken glass (any tickness, size,quality or description) from wooden / steel framesglazed with oil putty or fixed with beads complete all as specified and directed.
S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and directed.
S&F 3 mm thick figured glass, pin head type and glazing with oil putty in squares not exc 0.5 sqm in each pane complete all as specified and directed.
S&F in repairs 110mm bore PVC(SWR) pipes single soketed in any length with rubber ring jointed fixed to wall or in trenches including mild steel clamps complete all as specified and directed
S&F in repairs PVC (SWR) bends 110 mm dia complete all as specified and directed
S&F in repairs PVC (SWR) 110 mm dia junction, single(single 'T') equal or unequal complete all as specified and directed .
S&F in repair PVC(SWR) vent cowl of 110mm dia complete all as specified and directed
S&F in repairs PVC (SWR) pipes 75mm bore single socketed, in any length with solvent joints laid in trenches or fixed to walls with mild steel clamps complete all as specified and directed.
S&F in repairs PVC (SWR) bends 75mm dia complete all as specified and directed.
S&F in repair PVC(SWR) vent cowl of 75mm dia complete all as specified and directed
S & F in repairs for 75 mm dia PVC ( SWR) floor trap with grating including jointing with solvant complete all as specified and directed
S&F in repairs 25 mm dia aluminium powder coated droppery rod including brackets complete all as specified and directed.
S&F GI tubing 15 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors including taking down 15 mm dia GI tubing and connections complete all as specified and directed
Taking down and refixing 15mm bore GI tubing and connection in new or old position ( wall, floor, wall etc ) complete all as specified and directed
S&F GI tubing 20 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors including taking down 20mm dia GI tubing and connections complete all as specified and directed
Taking down and refixing 20mm bore GI tubing and connection in new or old position ( wall, floor, wall etc ) complete all as specified and directed
Cutting existing steel tubing for alterations or additions (Each cut measured) 15 /20 mm bore pipe complete all as specified and directed
Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector) 15 /20 mm bore pipe complete all as specified and directed
S&F in repair PVC float valve assembly including assessories with float valve 20mm dia complete all as specified and directed.
S&F in repair soap dish brass chromium plated fixed to wall with brass chromium plated screw and wooden/ plastic plug complete all as specified and directed
S&F in repair C P bib taps, cast copper alloy fency conceled type with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule of 15 mm bore and fixed complete all as specified and directed.
S&F in repair angular stop valve , 15mm dia, cast copper alloy,CP fancy type with long shank and cup screwd down, high pressure ,screwed both ends for iron pipes or for unions and fixed in pipe complete all as specified and directed
S&F in repair Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe. complete all as specified and directed
S&F in repair pillar taps, fancy type cast copper alloy with capstan heads, chromium plated, screwed down, high pressure with or without lettered “hot” or “cold” with long screwed shanks and fly nut screwed for iron pipe of 15mm bore, fixed in repairs complete all as specified & directed.
S&F in repairs PTMT PVC grating of 100 mm dia complete all as specified and directed
S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed
S&F in repair vitreous China WHB white flat back size 550x400mm including S&F angle iron brackets, C.P pillar tap fency type 01 No 15mm bore, CP waste coupling, 32mm dia and PVC waste pipe 32mm dia and PVC connection 450mm long high pressure complete all as specified & directed.
S&F in repair vitreous China squatting pan 'Orrisa pattern' size 580x440mm white with integral foot rests any pattern including provn of cement concrete bedding and making connection with & including 'P' or 'S' trap complete all as specified and directed.
S&F in repair vitreous China wash down water closet pan (pedestal pattern), white including white seat cover complete all as specified and directed
S&F in repair stainless steel sink, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 495mm x420mm with bowl size 410mm x330mm x160mm complete all as specified and directed
S&F in repair PVC low level flushing cistern of 10 Ltr capacity including flushing pipe bend PVC bend etc. complete all as specified and directed.
S&F in repairs Tolilet paper holder, vitreous China white, box type to walls with CP (CP) brass screws complete all as specified and directed
S&F in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard & railing 60cm long complete all as specified and directed
S&F in replacement rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position of 1000 ltrs capacity three layered wall construction complete all as specified and directed.
S&F in replacement rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position of 500 ltrs capacity three layered wall construction complete all as specified and directed.
M&L for applying two coats of elastomeric-acrylic waterproof protective cum decorative coating on external surface of RCC, concrete panels, plastered surface of wall etc. over a coat of primer including preparation of surfaces all as per manufactures instructions complete all as specified and directed. Make: Dr Fixit (Raincoat) or equivalent make as approved byGE
M&L for repairing and filling cracks up to 5mm width with crack-x paste ready to use crack filler (Make: Dr fixit or equivalant) for internal &external surfaces cracks in wall/ plaster all as per manufacture instruction including preparation of surfaces complete all as specified and directed.
M&L for applying evenly a coat of blown type bitumen 85/25 at the rate of 1.50 kg per square metre over a coat of bitumen primer @ 0.30 to 0.50 kg per Sqm and blinding with clean dry sand @ 0.05 Cum. per sqm over roof surfaces including preparation of old surface complete all as specified and directed.
Treatement for sunken portion is as follows :-
(a) Demolition of lean concrete and other type of filling in sunken portion & cleaned the sunken portion incl vertical wall surface complete as directed. (b) M&L for providing 12 mm dia holes of 40mm deep @200mm c/c at junction of beams and columns as co-ordinal points for inserting/pouring cement slurry by pressure grouting for sunken floors of toilet , includind sealing the holes with CM 1:3, all as specified and as directed by Engineer-in-Charge (c) M&L for water proofing plaster for sunken portion in CM 1:3, 20 mm thick in two coats with water proofing compound at the rate of 2% by weight of cement and finishing the surface even and smooth without using extra cement.(WPC will be measured and paid seperately). (d) M&L for applyin evenly two coats of industrial bitumen 85/25 at the rate of 1.20 Kg/Sqm in each coat over vertical surfaces and floors of sunken floors of toilet including cleaning of surfaces (e) M&L for PCC 1:7:12 type D2 using 40 mm graded stone aggregate as in filling (sunken portion) (f) M&L for PCC 1:2:4 type B0 using 12.50 mm graded stone aggregate, mixed with incl WPC @ 2% by wt. of cement, as sub base, 75mm thick. (g) M&L for plastering in CM 1:4, 15 mm thick with incl water proofing compound at the rate of 2% by weight of cement and finishing the surface even and fair.
Note :- above includes (a) Test again of water tightness by pounding for 72 hours & rectify defects if any till total elimination of defect.(b) The sunken portion shall be tested for leakage / seepage / dampness by pounding with water for 72 hours. In case any defect is noticed the portion shall be grouted with cement slurry mixed with suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage / seepage / dampness is eliminated (c) Horizontal flat area to be measered.
M&L for PCC ( 1: 2: 4) type B-0 (using 12.5mm graded stone aggregates) on roof top as a leveling course / padding to maintain the slope,finished the surfaces even and smooth without using extra cement complete all as specified and directed
M&L for provn of water proffing roof treatment to RCC roof with approved modified membrane of weighing not less than 3 kg/sqm comprising with following items including taking down of old roof treatment of any description including mud phushka, lime, concrete,tiles , cement plaster, padding upto 30cm depth from roof surfaces etc including cleaning, brushing and watering to joints and grooves and throwing the same to a distance exc 250 mtr and n exc 500 mtr from the roof of height 3 to 9 m height complete all as specified and directed .:-
(a) The surface of roof,parpet and gutters drain mouths etc over which water proofing treatment is to be applied shall be cleaned of all foreign matter such as fungus,mass dust etc by wire brushing and dusting. For cast iron drain outlets a groove shall be cut as specified and directed. (b) 15mm thick rendering in cement mortar 1:4 mixed with and including water proofing compound @ 3% by weight of cement applied over roof slab complete all as specified and directed. Note:-WPC shall be measured and paid separately (c) Oil based Bitumen primer conforming to IS-3384-1986 @ 0.3 kgs per sqm to be applied on prepared surface till the surface is properly impregnated. (d) Applying one coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm (e) Laying of water proofing teratment of weight not less than 3 Kg / sqm APP modified polymeric water proofing membrane composed of 100 micron (+10% ) high density polyethylene sheet ( HMHDPE) as center core, which is standwiched between high quality polymeric bitumen mix having softening , high heat resistance and cold flexible protected on either side with a thin thermo fusible HMHDPE film with side and laps 75 mm and 100 mm as per manufacture instruction etc. (f) Applying one coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm over the membrane (g) Applying aluminium paint in two coat @ 100 gm/sqm in each coat on finished membrane surfaces complete all as specified and directed at site .
M&L for provn of water proffing roof treatment to RCC roof with approved modified membrane of weighing not less than 3 kg/sqm comprising with following items and including taking down of old roof treatment of any description including mud phushka, lime, concrete,tiles , cement plaster, padding upto 30cm depth from roof surfaces etc including cleaning, brushing and watering to joints and grooves and throwing the same to a distance exc 250 mtr and n exc 500 mtr from the roof of height 3 to 9 m height complete all as specified and directed :-
(a) The surface of roof,parpet and gutters drain mouths etc over which water proofing treatment is to be applied shall be cleaned of all foreign matter such as fungus,mass dust etc by wire brushing and dusting. For cast iron drain outlets a groove shall be cut as specified and directed. (b) 15mm thick rendering in cement mortar 1:4 mixed with and including water proofing compound @ 3% by weight of cement applied over roof slab ,complete all as specified and directed. Note:-WPC shall be measured and paid separately (c) Oil based Bitumen primer conforming to IS-3384-1986 @ 0.3 kgs per sqm to be applied on prepared surface till the surface is properly impregnated. (d) Applying one coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm (e) Laying of water proofing teratment of weight not less than 3 Kg / sqm APP modified polymeric water proofing membrane composed of 100 micron (+10% ) high density polyethylene sheet ( HMHDPE) as center core, which is standwiched between high quality polymeric bitumen mix having softening , high heat resistance and cold flexible protected on either side with a thin thermo fusible HMHDPE film with side and laps 75 mm and 100 mm as per manufacture instruction etc. (f) Applying one coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm over the membrane (g) M&L for cement concrete tiles 25cm x 25cm x 22mm thick with grey cement and no pigment, machine pressed; set, jointed and pointed in neat cement slurry in floors, and cut and polished laid over and including 15 mm screed be in CM (1:4)
Supply only integral water proofing compound complete all as specified and directed
Taking down carefully copper/aluminum pt wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs, & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor etc.
M&L for point wiring for the following with 1.5 Sqmm PVC insulated FR, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC Casing -n-caping /conduit of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed :-
For one light point or fan point controlled by one switch
For one Call Bell point controlled by one push button switch
For 5Amp independent socket point controlled by one switch
For one 3 pin ,5 Amp socket point with other switch on the same board
All as per Srl item No.112.00 here in before but for power point wiring using with 2.5 sqmm PVC FR insulated ,unsheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,unsheathed, copper conductor stranded 1100 volt grade cable as continuous earth wire
M&L for concealed point wiring for the following with 1.5 Sqmm PVC-FR insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit, including modular metal flush boxes & modular white cover plate of suitable module with frame as per site requirement all fittings such as tees, bends, elbows, etc. all as per site requirements PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed:-
For one light point or fan point controlled by one switch
For one Call Bell point controlled by one push button switch
For 5Amp independent socket point controlled by one switch
For one 3 pin ,5 Amp socket point with other switch on the same board
All as per Srl item No.114.00 here in before but for power point wiring using with 2.5 sqmm PVC FR insulated ,unsheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,unsheathed, copper conductor stranded 1100 volt grade cable as continuous earth wire
S&F modular switch, one way,6 Amp 230, 1 module complete all as specified and directed .
S&F modular socket 6 Amp-2/3 pin combined 2 module complete all as specified and directed
S&F modular switch, one way,6 A/16 Amp 230, 1 module complete all as specified and directed .
S&F modular socket 6 A/16-2/3 pin combined 2 module complete all as specified and directed .
S&F modular fan step regulator 120 Watt -2 module complete all as specified and directed .
S&F modular bell push 6A one module complete all as specified and directed
S&F switch piano type flush, single pole, one way 5 A 230 Vcomplete all as specified and directed
S&F socket outlet, 5 pin, 5 Amp, flush type, 230 V complete all as specified and directed .
S&F switch piano type flush, single pole, one way 15 A 230 V complete all as specified and directed .
S&F socket outlet 2 in 1,6 pin, 5/15 A, flush piano type 240 V complete all as specified and directed
S&F ceiling rose, surface backlite,three terminal complete all as specified and directed .
S&F lamp holder insulated with back plate suitable for Angle/Batten fitting complete all as specified and directed .
S & F in repair/replacement bell ding dong 230 V, single phase complete all as specified and directed .
S&F electronic double space rotary 5 speed type regulator 120-280 V complete all as specified and directed .
S&F bell push flush type one way 5Amp 240 Volt complete all as specified and directed
M&L for sub main wiring with two single core PVC FR insulated unsheathed stranded copper conductor cable FR, 02 runs of 01 Single core of size 4 sqmm (for main current) drawn in & incl PVC Casing-n-caping of suitable size ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 4 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed
S&F in repairs testing and commissioning of MCB SP 240 volt 6 Amp to 40 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed
S&F in repairs testing and commissioning of MCB SPN 240 volt 16 Amp to 40 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed
S&F in repairs sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 8 way, 240 V with 200 Amps rated bus bar complete all as specified and directed . Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces shall be included in quote rate
S&F in repairs double door metallic sheet metal enclosure for DB double door(IP-42/43) When MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar complete all as specified and directed .Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces shall be included in quoted rate .
S&F in repairs TL fitting 20 watt for surface and wall mounted LED batten with ultra slim polycarbonate LED lighting fixture with high lumen output environmental friendly energy efficient complete all as specified and directed
S&F in repairs/replacement socket outlet multi purpose, 3 pin, 15 Amp & 3 pin 5 amp, combination complete all as specified and directed
pal enterprises
v k builder
M K Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .