| 1 | L1₹16.1 LAccepted-AOC NEAR OLD INDIAN OIL DEPOT JALANDHAR JAMMU BYE PASS ROAD PATHANKOT 145001 PB | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹19.2 L+₹2.2 L (13.0%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹22.5 L+₹5.6 L (32.7%)Rejected-Finance | L3 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹62,000
Closing Date
31 Aug 2021, 6:00 pmClosed
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
REPAIR TO LT EXT ELECTRIC SUPPLY EXT FIRE FIGHTING CRANES MISC INSTALLATION EXT WATER SUPPLY AT UCHIBASSI UNDER GE SOUTH PATHANKOT
2021_MES_466250_1
GES/PKT/T-17/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹62,000
Yes
30 Sept 2021
7 Aug 2021
2 Sept 2021
7 Aug 2021
31 Aug 2021
16 Aug 2021
Amount
Excavation in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide in any type of soil for laying and taking out of GI/CI pipes, complete all as specified and directed.
Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable, complete all as specified and directed.
Supply and laying sub class 'B' bricks of old size (standard size as per local availability) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Taking down/ Cutting MS pipe line of size 150 mm bore, including all fittings of any type, complete all as specified and directed.
M&L in replacement of M/S pipe line of size 150 mm bore with socket ends, centrifugally cast class medium grade in any length laid in trenches by means of welding (For firefighting installation) in required position as taken down under Srl item 6 above, complete all as specified and directed.
Relaying the MS pipe line of size 150 mm bore after cleaning as taken down under Srl item No 6 above including all fittings complete all as specified and directed.
Taking up and down old/ unserviceable MS tubing with fittings of size 100 mm bore including welding and cutting all as specified and directed by Engr-in-Charge. (earth work will be measured and paid separately).
Relaying the MS pipe line of size 100 mm bore after cleaning as taken down under Srl item No 9 above including necessary welding and all fittings complete all as specified and directed.
M&L in replacement of M/S pipe line of size 100 mm bore with socket ends, centrifugally cast class medium grade in any length laid in trenches by means of welding (For firefighting installation) in required position as taken down under Srl item 9 above, complete all as specified and directed.
Supply & fixing CI fittings up to 150 mm bore such as ( any type, bend/ color/ reducer and angle) tapers any type (straight,bends increasing,decreasing or double socket etc) tail pieces single branch Y junction,double branch cross (all sockets or socket ends spigot). All as required at work site and as directed.
M & L for S&F of CI sluice valve flanged of size 150 mm bore class PN-1.0 ISI marked with stainless steel spindle and iron wheel head complete with rubber gaskets, nuts, bolts washers and packing materials etc all as directed and as per site requirement.
All as per Srl No 13 above but of size 100 MM
All as per Srl No 13 above but of size 80 MM
Supply and fixing of CI non return valve of size 150 mm bore flanged ISI marked including bolts, nuts, washers and rubber gasket etc complete all as directed.
Supply and fix Cast Iron Foot valve including necessary fittings conforming to ISI mark conformed of size 100 mm bore complete all as specified and directed.
All as per Srl No 17 above but of size 150 MM.
M & L for supply and fixing Gun metal gate valve ISI marked with iron wheel head screwed both ends for pipe of size 50 mm.
All as per Srl No 19 above but of size 25 MM.
M & L for attending break down of pipe ling bursting /cracks including excavation in hard/dense soil with the use of earthmoving machinery/labour and taking out old CI/GI/MS defective/misaligned water pipe ling of size 200/150/100/50 mm dia bore carefully after disconnection of Joints to a length up to 6 mtr and create bund with excavate earths and excavated earth and dewatering/bailing out water complete with diesel engine driven pump set and positioning the pipe line after repairs/porocline, complete all as spesified and directed. Note:- (a) M/L for lead joints/spares/CI/GI specials will be measured and paid separately. (b) M/L for CI/GI/MS pipe, special lead joints ect will be measured and paid separately under relevant schedule items.(c) The rate is deemed to include cost for tool and plant and transportation required for attending the repair work.(d) Disconnecting /dismantling/cutting the existing pipe line is included in quoted rate.(e) The rate is inclusive of earth work complete including returinging and refilling in any type of strata complete.(f) The break down shal be attended within 4 hrs of intimation round the clock and time of restoration shall be maximum of 5 hrs. The additional manpower required to complete the work is quoted rate is deemed to be included in the quoted.
Cutting existing CI/MS water main 150 mm bore pipe and firefighting pipeline in position for making branch connection and CI pipeline (Insertion of CI tees bends of different size on connection pieces or for insertion of sluice valve) including excavation & earth work. Note : Cast iron fittings such as tees, bends, collars reducers etc) joints and jointing material for fixing cast iron fittings, sluice valve shall be measured and paid separately.
All as per Srl No 19 above here-in- before but of size 100 mm
M&L joints with rubber gaskets for CI flanged pipe including necessary nut bolts and washers etc for pipe 150 mm bore all as specified.
S&F replacement brass spindle with checknut suitable for sluice valve of size 80 mm bore including replacment of gland packing all as directed.
All as per srl item No. 25 above but of size 100 mm bore.
All as per srl item No. 25 above but of size 150 mm bore.
S&F in replacement unserviceable fire hydrant valve brass 65mm dia ISI mark (One end flanged and drilled holes) fitted with packing materials nut, bolts with washers complete all as specified and directed
S&F rubber mat 1x 2 mtr 19 mm thick laid down in front of LT panel / bus bar complete ISI marked.
Supply and fixing battery heavy duty 12 volt 180 Ah heavy duty with battery leads.
Supply only search light reachargeable heavy duty.
Supply and fixing pvc insulated copper conductor multistandardcable of size 25 sqmm single core.
Repair/Replacement of Centrifugal/Diesel pump set gland packing pump set to arrest lekage of water all as specified and directed by the Engr-in-charge
S&F in non percolated fire chief brand cotton synthetic fibre circular woven jacketed, ruberized fabric reinforced rubber lined (RRL) fire hose, delivery treated against rot with mystox, having 38 Kg/cm2 brust pressure, 22kg/cm2 proof pressure, 14kg/cm2 working pressure bearing IS 636-1988 type A mark & having TAC & MMD approval 63 mm inside dia in 15 mtr length with ISI marked male and female instantaneous coupling with copper binding complete all as specified and directed.
Painting fire hydrants hose boxes as per existing sizes complete including cleaning, scraping of old rusted surface paint inside and outside of panel surface with two coats of synthetic enamel paint and writing of SRL No as per existing size, complete all as specifid and directed.
S&F in replacement of broken glass of fire hydrant panel withnglass size 80cm x 14cm x 5 mm thick end covered type including rubber beading for finish of glass as per sample kept in the office of AGE E/M Unchibassi and, complete all as specifid and directed.
Taking out firefighting motor from the existing foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge including other allied items such as varnish tape, sleeve, greasing etc. of suitable size for 90 to 105 HP capacity of motor and refixing after testing and commisioning complete all as specified and directed
All as per Srl. Item No.37 above but for capacity 20 to 30 HP
S&F hose box made out of 2 mm thick sheet size 100 cm x 45 cm x 60 cm with a provision two fix MS flanged pipe for hanging of hose pipe, MS line to accommodadate hose pipe ,with front double window size 27 cm x 90cm , with glasses size 80 x 14 cm each with rubber beading with locking arrangements, painted red colour and numbered with white paint and opening the valves should be outside and inside the box only hose pipe safety complete all as specified and directed. Note: Hose box should be fitted in PCC/ Brick foundaction of 65cm x 50cm x 15 cm size, complete all as specifid and directed
Servicing,testing, calibaration to the existing AMF panel control of Jockey pump with Centrifugal pump to maintain the auto pressure of 50 PSI to 110 PSI including S& F of small parts below the price of Rs 3000, like power contractor, tripping and starting coil lugs, relay, Aluminium cable up to 50x 3.5 core up to 25 mtrs etc, complete all as specified and directed.
M&L for removing existing 105 HP Centrifugal pump set from base frame after disconnecting suction & delivery lines replacing bearings, repairing and grinding the shaft etc complete and reassembling and fixing back to original position and testing, commissioning etc, complete all as specified and directed. (Notes :- Any minor part up to Rs 2000 if required will be provided by contractor without any extra cost.)
All as per Srl. Item 41 above but for 25 HP Pump Set
M & L for removing existing Fan blade from 105 HP pump set motor and replacing and reassembling and fixing back to original position and testing, commissioning etc all as directed.
All as per Srl. Item 43 above but for 25 HP Pump Set
M&L in replacement of Pump shaft for 105 HP/75 KW capacity pumping set, including sleeves, machining, threading ,making key slot etc. complete all as directed.
M&L in replacement of coupling set with all accessories for Pump Set shaft of the 105 HP/75 KW capacity pumping set ,including machining ,threading, making key slot etc.as directed.
All as per Srl. Item 46 above but for 30 HP/18.5 KW Pump Set
M&L in replacement of CI impeller for 105 HP/75 KW capacity pumping set all as directed.
M&L in replacement of gland coupling brass bush for 105 HP/75 KW pumping set complete all as directed.
All as per Srl. Item 49 above but for 30 HP/18.5 KW Pumpset
M&L in replacement of gland cup including changing gland rope for the pumping set of capacity 105 HP/75 KW all as directed.
Servicing and maintaining pumping installation by tightening the gland of pump ,replacing rubber coupling,bushes and clearing the leakage of sluice valves, NRV's, aircock, pressure guage by tightening gland etc. comprising 2 Nos pump sets of capacity 105 HP/75 KW, 2 Nos, complete all as specified and as directed.
M&L for cleaning of SWT up to 1,00,000 gallons capacity including removal of all deposited scales, dirt and settled sand particles from intake of circulating pipe, cleaning with brushing, sweeping and brooming of inner and outer wall of the tank and washing the complete with bleaching powder soluting and also re-writing date of cleaning and markingall as directed.
Disconnecting the delivery line and providing dummy plate with nut, bolts to avoid water leakages and M&L for taking out vertical turbine pump /submersible pumpset of any make of capacity 20 HP to 35 HP from the tubewell/borewell carefully complete with column pipe for inspecting the condition of column pipe, pumpset & flat submersible cable etc complete all per site requirement complete all as specified and directed. Note:(i) The cost inclusive of necessary T&P of removing vertical turbine/submersible pumpset carefully without any damages to pump, motor, shaft, column pipe and casing. Any damages shall be beared by the Contractor at his own cost. (ii) The rate inclusive of dismanlting of motor of Vertical turbine pump set.(iii) The M/L for repairs to pumpsets/ column pipe/cable if required & measured and paid separately under relevant Schedule.
Lowering vertical turbine pump /submersible pumpset of any make of capacity 20 HP to 35HP inside the tubewell/borewell carefully complete with column pipe and other connected parts and including replacement of nut ,bolts, washers, gasket of suitable size all per site requirement and rec-connection with delivery line with nut ,bolts, washers, gasket of suitable size all as specified and directed. Note:(i) The cost inclusive of necessary T&P of lowering vertical turbine/submersible pumpset carefully without any damages to pump, motor, shaft, column pipe and casing. Any damages shall be beared by the Contractor at his own cost. (ii) The rate inclusive of re-connection of motor of Vertical turbine pump set.
Taking out electric vertical turbine motor of capacity 20 to 35 HP from the existing foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge including other allied items such as varnish tape, sleeve, greasing etc. of suitable size for 20 to 30 HP capacity of motor and refixing after testing and commisioning complete all as specified and directed.
S & F in replacement of thrust bearing all as per exisiting for motor of capacity 20 HP to 35 HP .
S & F in replacement of ball bearing all as per exisiting for pump of capacity 20 HP to 35 HP.
S & F in replacement of ratched plate assembly for vertical turbine pump with suitable coupling with reversible pin, balls, plate & pulley of pump of capacity 20 HP to 35 HP.
S & F in replacement of oil seal of pump of capacity 20 HP to 35 HP
S & F in replacement of oil seal of pump of capacity 37.5 HP to 50 HP
Dismantling rotor shaft of 3 phase electric motor of capacity 20 HP to 35 HP, welding to bearing size of rotor, check nut size of rotor & turning, polishing, threading & grinding etc. upto required size of bearing all as specified and directed.
Turning to bearing size of motor top & bottom covers, providing joinings of new bearing sleeves of CI for bearings no. 7220. 7316,6311,6310 etc. and grinding upto required bearing size all as specified and directed.
Dismantling the bowl assembly of Vertical Turbine Pump any type, capacity and make for carrying out repair and replacement of worn out parts by strip opening of all parts such as impellers, pump shafts, lock collects, bushes, neck rings etc. and machine work such as welding, turning, refacing where required and replacing of defective parts up to and including 11 stages of size 150mm dia for pump capacity of 30 to 50 HP: - Note: - spare parts and their fixing shall be paid separately under the respective items of schedule 'A'
S&F in replacement of pump shaft 30 to 38 mm dia of stainless steel suitable for bowl assembly upto 12 stages including threading, cutting to size all as specified and directed.
S&F in replacement gun metal impellers of suitable size for bowl assembly casing as per site requirement for suction, discharge and intermediate bowls complete all as specified and directed.
S&F in replacement intermediate gun metal bush for bowl assembly of suitable size as per site requirement of make and model as per existing for suction, discharge and intermediate bowls of size 100mm to 150mm complete all as specified and directed.
S&F in replacement cast iron bowl casing of size suitable as per site requirement, any type, make and model as per existing for suction, discharge and intermediate bowls of size 100mm to 150mm dia including studs, nuts, bolts and washers complete all as specified and directed.
S&F in replacement neck ring of bowl casing made out of gun metal/brass for assembly of suitable size as per site requirement, any type, make and model as per existing for suction, discharge and intermediate bowls complete all as specified and directed.
S&F in replacement impeller lock collects for bowl assembly of suitable size as per site requirement any type, make and model as per existing for suction, discharge and intermediate bowls complete all as specified and directed.
S&F in replacement neck ring for impellers made out of gun metal/brass for assembly of suitable size as per site requirement, any type, make and model as per existing for suction, discharge and intermediate bowls complete all as specified and directed.
S&F in replacement rubber bush of bowl assembly of suitable size as per site requirement any type, make and model as per existing for suction, discharge and intermediate bowls complete all as specified and directed.
S&F in replacement studs with nuts, springs, washers complete all as specified and directed.
S&F in replacement spider lock/nut lock complete all as specified and directed.
S & F Mild steel column pipe for vertical turbine pump 150 mm dia, heavy grade and 3 mtr. Long duly threaded on both sides as per site requirement including one mild steel coupling all as specified and directed.
Strip opening of 3 phase AC submersible motor, taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including PVC seal (water proof compound) and thrust bearing as per requirement of existing size and make, re-assembling the motor and testing complete of capacity 20 to 35 HP motor.
Taking out worn out bearing/ bush sleeves from the submersible motor of capacity 20 to 35 HP and providing new stainless steel, turning and polishing of bushes complete including checking of allingment complete in all respect all as specified and directed.
S & F in replacement of thrust bearing plate along with disc of motor of capacity 20 HP to 35 HP
S & F in replacement of oil seal of motor of capacity 20 HP to 35 HP.
Dismantling the submersible pumping set bowl assembly/motor of any make for carrying out repair and replacement of worn out parts by strip opening with all parts such as bowl casing, impellers, pump shaft, bushes neck ring etc.and machine work such as welding, turing, re-facing where required and replacing of parts of pump of 4 to 9 stages, size 150mm, of capacity 20 HP to 40 HP capacity. Note: - Spares parts and their fixing shall be paid separately under the respective item of schedule 'A'
S & F in replacement of pump shaft of stainless steel suitable for submersible pump set up to 9 stages including threading, cutting to required size all as specified and directed.
S & F in replacement of gun metal/Stainless Steel impellers of suitable size for bowl assembly of submersible pumping set as per site requirement for suction, discharge and intermediate bowls complete all as specified and directed.
S & F in replacement of cast iron casing suction/discharge/ intermediate with studs.
S & F in replacement of shaft seal of rubber all as specified.
S & F in replacement neck ring of bowls suction/discharge/ intermediate
S & F inn treplacement of gun metal bush of bowls all as specified
S & F in replacement of rubber bushes of bowls assembly of suitable, make and model as per existing for suction and discharge bowls.
S & F in replacemnt of shaft coupling with key stainless steel of suitable sizes, type, make and model as per existing all as specified and directed.
S & F in replacemnt of stainless steel middle/distance bush of suitable size all as required at site and directed.
S & F in replacemnt of stainless steel impeller key all as specified and directed.
S & F in replacement of studs with nuts all as directed.
Supply and fixing of mild steel column pipe coupling 150 mm dia, heavy duty 3.0 Mtr long threaded or flanged all as specified and directed.
Supply and fixing of mild steel column pipe coupling 125 mm dia, heavy duty 3.0 Mtr long threaded or flanged all as specified and directed.
Supply and fixing of mild steel column pipe coupling 100 mm dia, heavy duty 3.0 Mtr long threaded or flanged all as specified and directed.
Supply and fixing of mild steel column pipe coupling 80 mm dia, heavy duty 3.0 Mtr long threaded or flanged all as specified and directed.
Supply and fixing line shaft bearing retainer of gun metal with rubber bushes for column pipe 150 mm dia all as specified and directed.
Supply and fixing of stainless steel line shaft coupling of size 25 mm to 31 mm dia.
Supply and fixing of stainless steel shaft sleeve of size 25 mm to 31 mm dia.
Cutting and removing worn out threaded portion of mild steel column pipe heavy duty and re threading the same up to specified length to match with socket of size 150 mm dia.
Cutting and removing worn out threaded potion mild stell/stainless steel line shaft of any dia, length and rethreading the same up to specified length to match with existing coupling all as specified and directed.
S & F new bolts,nuts and washers in places of existing worn out/unserviceable bowl bolts.
S & F Mild steel column pipe for submersible pump set, 150 mm dia, 5 mm thick and 3 mtr. Long duly screwed/welded flanged on both sides with bolts & nuts to mild steel flange including rubber joints all as specified and directed.
Dismantling of Vertical Turbine motor 30 to 45 HP including discharge head and top shaft, stuffing box. Replacement of gun metal bushes, filling of gland packing, Replacement of studs of discharge head and top shaft of length up to 10 ft including top nuts and locking nuts.
S&F for submersible cable 16 Sqmm copper 3 core all as specified and directed by Engr-in-charge.
M&L for chlorination treatment with high stable Calcium based granular disinfectant for water treatment, more stable than Chlorine Gas, and stronger than bleachingpowder, and sodium Hypochlorite) packing in 45 kg drum complete all as specified and directed by Engr-in-Charge. Make : Purechlor or equivalent approved make by E-in-C branch
S&F in repair chlorination dosing system booster pump of cap.as per existing system and as as directed.
M&L for rectification of existing defective run lead joints including burning and removing the old defective lead joints and providing new lead joints with all required materials and testing the joints for leakages for the following sizes of CI/DI pipes complete all as directed(Note:Earth work shall be measured separately)
80 mm dia
100 mm dia
Supply and replace sluice valve spindle made out of EN-8 steel with check nut made out of brass/bronze material including replacing perished gland packing, rubber gasket, bolts and nuts suitable for the following sizes of sluice valves all as directed :-
80 mm dia sluice valve
100 mm dia sluice valve
150 mm dia sluice valve
S&F in replacement for Cl sluice valve, non-rising type conforming to IS-14846, sutiable for 80 mm bore pipe consisting of SS spindle as per IS 6603, Cast iron Body, Dome & Wedge as per IS 210, greasy jute type gland packing, fasteners as per IS 1367, Natural rubber gasket, CI manual hand wheel etc complete double end flanged and drilled, of Class PN-1.6 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut ,bolts and washers etc complete all as specified and directed.
All as per above item but 150 mm dia
All as per above item but 100 mm dia
M&L for attending break down of pipe line bursting/cracks including excavation in hard / dense soil with the use of Earthmoving machinery / labour and taking out old CI /GI/MS defective / misaligned water pipe line of size 200/150/100/80 mm dia bore carefully after discon-nection of joints to a length up to 8 mtr and create bund with excavated earth and dewatering / bailing out water complete with diesel engine driven pump set and positioning the pipe line after repairs, returning filling and removal of surplus soil / excavated material with the help of excavator / proclainer all as directed by Engineer-in-Charge. NOTE : (a) M/L for Lead Joints/ spares / CI /GI specials will be measured and paid separately.(b) M/L for CI / GI/MS pipe, Specials, lead joints etc will be measured and paid separately under relevant Schedule Items (c) The rate is deemed to include Cost for tool and plant and transportation required for attending the repair work.(d) Disconnecting / dismantling/ cutting the existingpipe line is included in the quoted rate.(e) The rate is inclusive of earth work complete including returning & refilling in any type of strata complete. (f) The breakdown shall be attended within 4 Hrs of intimation round the clock and time of restoration shall be maximum of 8 Hours. The additional manpower required to complete the job in quoted rate is deemed to be included in the quoted.
Laying/ Refixing only CI/DI/MS pipe line of bore 150mm dia obtained against items No 12 & 13 here-in-before.
Laying/ Refixing only CI/DI/MS pipe line of bore 100mm dia obtained against items No 12 & 13 here-in-before.
Laying / Refixing only CI/DI/MS pipe line of bore 80mm dia obtained against items No 12 & 13 here-in-before.
M&L for MS hardware like MS sheet for valve chamber covers, duct covers, angle iron, bolts/nuts/clamps etc incl dismantling old one. (The rate quoted deemed to be inclusive of CC for coping/grouting of angle iron along with PCC etc complete)
Supply and fix gun metal gate valve with iron wheel head screwed both ends for iron pipe of size including dismantling old one.
15 mm dia bore
20 mm dia bore
25 mm dia bore
40 mm dia bore
50 mm dia bore
Supply and lay in trenches/ on roof/ on wall/ steel water tubing galvanised medium grade with all fittings of following sizes incl dismantling old one:-
15 mm dia bore
20 mm dia bore
25 mm dia bore
40 mm dia bore
50 mm dia bore
Laying/ Refixing only GI tubing including fittings such as bends, elbows sockets, unions etc as required for following dia complete all as specified and directed.
15 mm dia bore
20 mm dia bore
25 mm dia bore
40 mm dia bore
50 mm dia bore
Supply only heavy duty hose pipe suitable for 6 HP sewer DD pumpset of 80 mm Dia with locking arrangements adaptor
Repair to GI pipe lines of size 15 to 25 mm bore dia and repair to leaked joints of pipe line complete including replacement of GI fitting i.e union,nipple & sockets if required including excvation and taking up & down required cutting & threading refixing in position in trenches & all as directed.
All as per Srl Item No.141 above but size 40 to 50 MM bore.
Dismantling of old U/S valve pit of size 120x120x90 Cm ( internal dimensions of the chamber) including and removing the debris at a distance not exceeding 50 Mtr and M/L for brick massonary with cement mortar with 1: 6 , 23 cm and flush pointing externaly work proceeds in the same mortar complete ( using 30% old bricks & 70% New bricks) complete with the following specifications and as directed. Note :-(i) 10mm thick plaster internally in CM 1:6.(ii) Flooring 40mm thick in PCC 1:2:4 type B-1 over 75mm thick hard core of guage not exc 63mm thick. (iii) Angle iron frame 40X40X6mm thick for cover and mild steel 3mm thick cover with locking arrangement,handle and necessary hinges etc, (iv) PCC 1:3:6 type C-2 100mm thick in foundation.(v) Two coat of synthetic enamelled paint to cover internally and externally over a paint of Red Oxide primer.
All as per Srl Item No.143 above but of size 100x100x105 cm
All as per Srl Item No.143 above but of size 90x90x105cm
All as per Srl Item No.143 above but of size 60x60x60 cm
Supply and fixing in repair Rubber gasket joint suitable for 150 mm bore cast iron/ DI pipes all as specified and directed.
Supply and fixing in repair Rubber gasket joint suitable for 80 mm bore cast iron/ DI pipes all as specified and directed.
Material and labour PCC 1:4:8 type -D2 using 40mm graded aggregate in fdn filling and mass complete for pipe line supports or any indicated position all as specified and directed by Engr-in-charge.
Material and labour for cleaning of over head water tank of capacity above 1,00,000 Glns and upto 1,00,000 Glns at 15m to 21 m approx height staging by draining out/bailing out/ pumping out the accumulated water at the bottom and removing the complete silt from the sump and depositing and levelling as directed and cleaning the tank with the bleaching powder slurry and wire brush after scrapping the walls and bottom of the tank completely including flushing out inlet/outlet/washout pipes/ valves complete without disturbing the water supply to the area including painting the details of sump capacity, date of cleaning and due date of cleaning on the sump wall and applying one coat of white wash to entire sump internally complete all as directed by Engineer-in-Charge.
All as per Srl item No.150 above but upto 50000 gallons complete all as specified and directed.
Disconnecting/ Removing existing U/S scale type water level indicator and S&F dial type water level indicator suitable for Over Head Storage tank of height 15 m to 21 m staging complete with central movement plate, counter weight, centre dividing wheels, MS/CRCA enclosure, float and connecting control wire system from tank to indicator etc complete grouted in PCC all as directed including testing and commissioning all as directed. Note for item No 150 to 152: The rate quoted inclusive of all safety equipments, T&P for carrying out the repair/working on OH tanks and insurance to persons deployed for cleaning the over head tank. Any unforseen incidents/accidents due to lack of safety norms shall be beared by the Contractor on " No cost basis" without any extra claim from department.
Dismantling old defective water meters and M & L for CI water meter Woltman type Magnetic Drive Class-B Flanged end of size 100 mm
S&F in repair single phase preventor relay with timer for auto restart option with protection features against single phasing, phase reversal, phase unbalance etc complete with control wiring all as directed.
Supply and fix in replacement of old unsv aviation light with Red LED aviation obstruction light of 20 W,50Hz ,230 V, epoxy yellow painted die-cast aluminium alloy with polycarbonate dome complete all as specified ad as directed.
Dismantling old defective flow meter and Supply , install, testing and commissioning of electromagnetic flow meter of size 40 mm dia bore with approx minimum flow range 1.3 Cum per Hr , maximum flow range 54.20 cum per Hr, hastealloy C-4 electrodes material, CS flange with ANSI 150, PTFE lining , digital display suitable for operation on 100 to 230 V AC 50 HZ supply with output 4 to20 mA DC for measuring water fluid .
Dismantling old defective flow meter and Supply, install, testing and commissioning of electromagnetic flow meter of size 80 mm dia bore with approx minimum flow range 5.4 Cum per Hr , maximum flow range 217.10 cum per Hr, hastealloy C-4 electrodes material, CS flange with ANSI 150, PTFE lining, digital display suitable for operation on 100 to 230 V AC 50 HZ supply with output 4 to20 mA DC for measuring water fluid .
Dismantling old defective flow meter and Supply, install, testing and commissioning of electromagnetic flow meter of size 100 mm dia bore with minimum flow range 8.4 Cum per Hr , maximum flow range 339.20 cum per Hr, hastealloy C-4 electrodes material, CS flange with ANSI 150, PTFE lining , digital display suitable for operation on 100 to 230 V AC 50 HZ supply with output 4 to20 mA DC for measuring water fluid . Make: ABB/ Siemens/ Forbes Marshall/Sai Tech.
Plain cement concrete (1:4:8) type D-2 (Using 40 mm graded crushed stone aggregate) as in foundation for mass concretes or in any indicated positions etc complete all as specified
Plain cement concrete (1:3:6) type C-2 (Using 40 mm graded stone aggregate) as in foundation filling and mass concrete for stay complete all as specified
Plain cement concrete (1:2:4) type B-2 (Using 20 mm graded stone aggregate) for foundation coping complete all as specified
M&L for replacement of existing UNSV schematic diagram with LED laminated display with openable transparent glass covered of main incoming and outgoing elect supply/water supply to various destination and generator supply destination all as directed and specified size of display not less than 1.5x3.0 mtr with all decoration as specified.
M&L for replacement of acrylic sheet diagram of main incoming and outgoing elect supply/water supply to various destination and generator supply destination all as directed and specified size of display not less than 1.0x2.0 mtr with all decoration as specified.
M&L for replacement of acrylic sheet DO and DON'T instructions in Hindi/Punjabi and English launguage for elect supply installations and water supply installatllations all as specified size of display not less than 2.0x1.0 ft with all decoration as specified.
M&L for replacement of acrylic sheet instructions for pump operation in Hindi/ Punjabi all as specified size of display not less than 2.0x1.0 ft with all decoration as specified.
M&L for fire point comprising of the following. (a) CO2 fire extinguisher 4.5 Kg (02 Nos), b) Dry carbon powder (ABC)-05 Kg (02 Nos) ,ceiling Hook,fire beater,sand buckets 9 mtrs capacity-02 Nos ,Showel complete with angle iron stand duly painted with two coats of synthetic enamel paint of approval colour over a coat of red oxide primer incl dismentling old unsv one.
M&L for replacement of electric shock and its management with picture in Hindi/Punjabi all as specified size of display not less than 2.0x1.0 ft with all decoration as specified.
M&L for replacement of Maintenance schedule of Sub stations instructions board on acrylic sheet in Hindi/Punjabi all as specified size of display not less than 3.0x1.5 ft with all decoration as specified.
M&L for replacement of Yearly periodical maint of HT Circuit Breakers on acrylic sheet in Hindi/Punjabi all as specified size of display not less than 3.0x1.5 ft with all decoration as specified.
M&L for replacement of DO's & DON’T's for HT circuit breakers on acrylic sheet in Hindi/Punjabi all as specified size of display not less than 3.0x1.5 ft with all decoration as specified.
M & L for laying stone graded coarse aggregate of size 40 mm for foundation filling at sub station two pole/ four pole complete all as specified and directed by engr-in charge.
M & L for laying stone graded coarse aggregate of size 20 mm for foundation filling at sub station two pole/ four pole complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement existing UNSV tube light fitting with LED 20W inverter batten type fitting 4 feet long aluminium extruded housing,IP-20 ,rated voltage 230 V, 50 hz, charing time 10-12 hours and backup time 04 hours system wattage 20W +/- 10%, system current less than 102 mA, power factor more than 0.95, system lumen efficiency 100lm/watt,CCT 6500K, CRI more than 80, THD less than 30%, driver efficiency more than 85% complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
Supply and fix bldg security light fittings with LED security light fittings 60 watt, IP 65 having pressure die cast aluminium alloy housing, prismatic polycarbonate cover complete including making connection with 3 core copper flexible cable of suitable size including galvanised iron pipe bracket 0.90 mtr long of 25 mm dia and fixing with bldg for fixing of street light fitting all as directed. Note: (i) Driver Efficacy – more than 85% ( constrant current driver).(ii)Driver Type – Potted (iii) THD - < 10% (iv)Led Driver Current – less than 750 mA(v) Efficacy of Led Fixtrue – 100 lm/watt ( minimum) (vi) Efficacy of Led Chip – more than 130 lm/watt( Vii) Surge Protection – 4 KV & above as per IEC standard inbuilt in Driver and External SPD 5KV (vii) Working Humidity - 10% to 90% RH (ix) Led Make – Nichia/Philips Lumiled/ Cree /Osram/ Seoul (x) Life – 50,000 hours at 70% lumens(xi) CRI – more than 70 (xii) Lens – Each Led shall be of High Power ( 1 to 3 watt only) with mandatory modular lens. (xiii) Working Temp – 0 to 50 degree C. (xiv) Heat Sink – Pressure die cast aluminium (xv) Junciton Temp – 100 degree C (xvi) Body of Fitting – Pressue Die Cast with company logo / make engraved or embossed in housing LM 6 Grade.(xvii) Impact code – Min IK05 or more (xviii) LM79 report from Third Party ( instead of company in house lab) NABL /UL accredited lab. (xix) LM80 report from Led Manufacturer.(xx) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixtrue.(xxi) MS Clamp fittings with nut bolts and GI bracket, junction box included in the rate.(xxii) Test certificates to be submitted before commencement of work/ claiming for payment .(xxiii) Warranty certificate for minimum 2 years to be submitted from OEM.
M & L for insulation mat 3.3 KV ISI suitable LT panel complete all as specified and as directed.
M & L for insulation mat 11 KV ISI suitable MRS complete all as specified and as directed.
M & L for flex board outdoor type with acrylic sheet mounted on aluminium framed supports box type of size 3"x2" with duly supported by 40 mm size SS tubing round the box incl stand of hight not less than 1.5 mtrs from the gorund level with LED 2x9watt lighting arrangement complete. Note: PCC will be measured & paid seperately
M&L for GI pipe light grade 50 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection .
M&L for GI pipe light grade 40 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection .
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade 3.5 core PVC sheathed, armoured, electric power cables (heavy duty) with aluminium conductor of the following size including dismantling old one. Note: The rate quoted inclusive of termination at ends with suitable aluminium lugs wherever required.
25 Sqmm 4 core
3.5 core 35 Sqmm
3.5 core 70 Sqmm
M&L for heat shrinkable end termination joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 16 to 50 sq.mm.
All as per Item above herein before but for cable of size 3.5 core 70 to 120 sq.mm.
All as per Item above herein before but for cable of size 3.5 core 150 to 185 sq.mm
Supply & fixing in repairs of MCCBs of following current carrying capacity including necessary connecting terminals to bus bar, nut bolts etc complete all as directed .
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 200-250 A rated
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 160-200 A rated
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 125A to 160 A rated .
M & L for replacement of unsv/broken thermoplastic polycarbonate spring type locks suitable for panel locking (Mi DV 01 with Mi SR 4) complete.
Restretching of ACSR conductor of any size of over head lines LT/HT on poles including binding with insulators, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed. Note: ACSR conductor Required for winding etc to be included in quoted rates.
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5 core 16 to 50 sq.mm.
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5 core 70 to120 sq.mm.
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5 core 150 to185 sq.mm.
Dismantling unserviceable cross arms including clamps, bolts, nuts, washers etc from pole.
Supply, fabricate and fix cross arms any size along with, brackets, clamps, bolts, nuts, washers, bracers etc including drilling holes, cold/hot complete and fixed to pole including one primer coat and one under and finishing coat of paint.
Dismantlin of ACSR conductor of any size, from insulator etc from the structure/over head line all as directed.
M&L replacement of ACSR conductor of any size as ordered by Engr-in-charge including tightening and bindingh with new binding wires to insulators all as directed.
Dismantling insulators any type, size
M&L pin type insulator vitreous, white, brown, or green insulator includig one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65 mm dia for 1100 volts grade.
Repair, maint and making the fully functioning of flameproof electric operated crane of cap 2 Ton to 5 ton after checking long travell motion , cross travel motion , hoisting motion (electrically and mechanically) in presence of user rep and MES rep & rectify any type of defects immediately when found including servicing, greasing, top up gear box oil & carrying out routine maintenance as directed by Engineer in Charge (Note :- (i) any accessories found unserviceable that shall be replaced under respective items of this Sch. (ii) : Labor for lowering, mounting arrangement such as ladder , pulley block, rope system, T&P , any type nut, bolt, washers and other connected mechanism shall be contractor arrangement and rates are deemed to be included in this Job. No extra payment will be made to the contract against lowering/lifting the spare etc at a height of 20' to 30' (iii) Repair/maint of each flame proof EOT crane of capacity 2 to 5 Ton (total 17 Nos) for two times or as per complaint of EOT cranes in a month.
Dismantling the main driving shaft of forward/reverse drive of flameproof EOT crane after unscrewing nuts, bolts, washers including other connected accessories with shaft such as breaking assembly, coupling, bearings rings, gear box lowering down the smaller portion of shaft from up to 30' approximate height for removing and threading, repairing manufacturing cutting teeth keys one Nos bearing housing cabinet and replacement of one Nos tapper bearing welding of foundation rest pad making drills holes in rest pads matching with main foundation of trolly, cleaning, greasing and oiling of all the bearing, bearing housing, gear box etc complete for smooth functioning including providing nut, bolts with locking arrangement & washers of any type/size as site requirement complete including re-assembly with connected accessories after repair including carrying out necessary alignment of all the parts connected with shaft all as specified and directed by Engineer-in-charge (Capacity of crane - 2 to 5 Ton )
Dismantling of micro -up and down drive arrangement of flameproof EOT crane after un-screwing L- key bolts/screws nuts, washers etc which includes gear box of micro drive main box of up -down drive, braking arrangements including dismantling of 3 set (3 pair) of micro coupling, micro-drive arrangement for under taking repair including getting down all as dismantled parts from existing platform at a minimum height about 20' to 30' approximately reassembling and re alignment all the parts complete including testing on load on both micro and main drive complete all as specified and directed by Engineer -in-charge (capacity of Crane 2 to 5 Ton )
Dismantling/strip opening gear of micro main shaft drive for replacement of 2 Nos gun metal bushes having internal lining for oiling arrangement, replacement of all the nuts/bolts of bush side plate with L-key, bolts of size as per sample oiling/greasing of gear box including necessary cast iron repair to broken foundation which includes welding lathing and grinding complete all as specified and directed by Engineer -in-charge. (Crane capacity 2 to 5 Ton )
Dismantling and refixing after repair brake shoe leather suitable any motion of flameproof EOT crane 2 to 10 ton cap complete all as specified and directed Engineer in charge.
Dismantling/strip opening flameproof micro drive box complete with rectifier transformer arrangement, magnetic disc both side coupling for remotting both the side ends of driving shaft (Gear box coupling side and braking arrangement coupling side) making multi key arrangement on both the shaft and couplings (teeth system ) to avoid any kind of play in coupling and shaft including replacement of 4 Nos carbon bushes, replacement of 02 Nos gun metal bushes including making oiling arrangement in bushes and side covers of bushes/ housing of micro drive re-assembling/testing complete (crane capacity up to 5 Ton), complete all as specified and directed.
Dismantling/strip opening of up/down micro electric braking arrangement after un-screwing nuts, bolts washers, re-adjustment of braking springs, replacement of brake leathers, replacement of two Nos 440 volts any make brake coils, replacement of both gun metal bushes of shaft housing in brake box making oiling/greasing arrangement complete re-assembling and testing, complete all as specified and directed.(Crane capacity 2 to 5 Ton )
M&L for replacement coupling as per sample or approved by GE suitable for perfect alignment between flameproof motor and driven machine, complete all as specified and directed.
M&L for replacement of L Key bolts 1" x 10mm as per sample or approved by GE including applying moose threads found worn out and taking out broken bolts from body/housing of machine for 2 to 5 ton capacity flameproof EOT Crane, complete all as specified and directed.
Dismantling/ lowering of burnt flame proof/weather proof three phase 440 volts , 50 Hz , 960 RPM , class F, 5 HP induction motor from platform complete including strip opening the same and rewinding with super enameled copper winding wire of same size/ gauge as existing earlier complete including all backing material, insulation material and re- installation the same at original site complete all as specified and directed.
All as per Srl item No.212 but capacity of motor 3 HP.
M & L for of Power contactor 3 pole 16 Amp, 110 Volt as per sample or approved by GE, complete all as specified and directed.
M & L for of Power contactor 3 pole 40 Amp, 110 Volt as per sample or approved by GE, complete all as specified and directed.
M & L for of Over load relay 1.7 to 2.4 Amp as per sample or approved by GE complete all as specified and directed.
M & L for of main bearing as per site requirment suitable for 2 to 10 Ton cap crane, complete all as specified and directed.
M&L for breake oil suitable for flameproof EOT crane up to 5 Ton cap as per manufacture recommendation, complete all as specified and directed.
M&L for grease suitable for flameproof EOT crane up to 5 Ton cap as per manufacture recommendation, complete all as specified and directed.
S & F Thruster for flame proof EOT crane cap upto 5 Ton complete with all accessories, complete all as specified and directed.
M&L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.3 mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using using galvanised iron strip 32x6mm earthing lead as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil remain surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge incl testing on completion.
Taking out carefully unserviceable cable up to 95 Sqmm from trenches and relaying same after repairs in same or other indicated location after testing complete all as specified directed by Engr-in-Charge.( Note: Earth work, sand, bricks will be measured and paid separately)
Supply and laying in trenches or fixing to wall/pole or passing through pipe PVC insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 70 Sqmm 3.5 core. (Note : Incl making good all distributed wall surfaces/ flooring/ tilling to match with existing specification)
All as per item No 223 above but cable of size 50 Sqmm 3.5 Core
All as per item No 223 above but cable of size 35 Sqmm 3.5 Core
Cable jointing kit for 1100 volt grade cable for straight through termination heat shrinkable type complete with jointing material and accessories suitable for XLPE/PVC armoured aluminium conductor cable of size 25 to 50 Sqmm 3.5/4 core.
All as per item No 226 but for 70 to 150 Sqmm size.
Taking down carefully copper/aluminum point wiring(light,fan,socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, flors, etc.
M&L for point wiring with steel conduit 1100 volts grade single core FRLS having multi stranded copper conductor of 2.5 Sq mm nominal cross sectional area (ISI marked with valid CML No) drawn in and includin stove enamelled steel conduit less than 25 mm dia with all fitting and fixing accessories in surface wiring system and with 1.50 Sqmm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor connected to earth dolly complete all as specified and as directed.
Taking down carefully sub main wiring of any nos of wire and size with earth wire from wooden batten/surface conduit/casing caping complete with its all accessories
M&L for submain wiring with two single core PVC insulated flexible copper conductor cable of sze 4 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 2.5 Sqmm as earth lead in & including concealed PVC conduit light grade cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site, complete all as specified and directed.
S & F switch flame proof rotary type with termination box in LM6 16A single pole 250 V, complete all as specified and directed.
Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth, complete all as specified and directed.
Supply and fix flame proof weather proof DB TPN 240 volts 8 Way with busbar in cast aluminium LM-6 enclosure operated externally spring type knob complete with M-25 cable entry to suit incoming cable and 2 Nos M-20 cable entries for outgoing cable from bottom with cable glands suitable for hazardous area and confirming to IS-2147/62 neoprene gasket degree of protection IP 65 including flame proof MCB as under all as per directed and specified (a) MCB TPN 32 Amp - 01 No. (b) MCB SP 10 Amps - 04 Nos (c) MCB SP 20 Amps 2 Nos including taking down, complete all as specified and directed.
Material and labour earthing with copper earth plate electrode of size 600 mm x600 mm x3.15 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected with 20 x 3 mm copper strip as earth lead electrode by means of nuts, bolts and washers, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of gem all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, copper earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Supply and fixing in repair flameproof weather proof exhaust fan with louver shutter of size 380mm with 0.25 Hp flame proof motor240 volts, 50 Hz, single phase inculuding making hole, and making good surface after fixing the fan, complete all as specified and directed.
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
M/S SHRI RAM BUILDERS
JAI DURGA CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .