Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹39.7 L+₹1.4 L (3.52%)Rejected-Finance 67 A HAFIZALI BAHADUR KHAN MARG SURAJI COMPOUND BEHIND KHATAU MILL BYCULLA W MUMBAI 400011 BRITE INDUSTRIES 67 A HAFIZALI BAHADUR KHAN MARG SURYAJI COMPOUND BEHIND KHATAU MILL MUMBAI | MUMBAI | MAHARASHTRA | 400011 | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹42.8 L+₹4.5 L (11.8%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L3 | Rejected-Finance Higher bidder | |
| 4 | L4₹43.3 L+₹5.0 L (12.9%)Rejected-Finance | L4 | Rejected-Finance Higher bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical Not recommended since not enlisted in b(ii) category |
Tender Value
₹38.7 L
EMD Value
₹77,400
Closing Date
11 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
PROVISION OF ADDITIONAL POWER SUPPLY FOR PROJECT MSMSE AT NUWR GOA UNDER GE NW VASCO
2021_MES_482865_1
85484/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE NW VASCO
₹77,400
Yes
22 Mar 2022
20 Oct 2021
14 Dec 2021
20 Oct 2021
11 Dec 2021
27 Nov 2021
60 days
Amount
Supply and installation of Ring main unit 4 way RLLL 11KV, 630A 21 KA/ 3S, Outdoor Extensible Type, 1 No Manually Operated LBS Feeder Incomer and 3 Nos Manually Operated VCB Feeder Outgoing ,8DJHST Type RLLLL Internal ARC Design-21KA/1S all as per specified by manufacturer of directed and comprising with the standard fittings/accessories including foundation and plinth complete all as specified and as directed
Supply install, testing and commissioning of distribution transformer mounted on masonry platform step down, 11KV / 0.433KV. Three Phase complying with IS 1180 / IEC -76(Part-1) 2014 with latest ammendments .Outdoor type double copper wound suitable for 50 Hz system of capacity 400 KVA,oil immersed naturally cooled delta connected on HT side and star connected on LT side ,vector group Dyn 11,provided with OFF load tap changer to vary secondary voltage from -7.5 % to + 7.5 % in step of 2.5 %. Losses should be confined to the limits specified as follows maximum allowable losses at full load (100 %) & Half Load (50 % )shall not be execeeded 0.98% & 0.70 % Percentage Impedance 5% Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335 .The transformer should have both side cable end box with neutral brought out complete and installation of transformer shall be carried out as per I5-10028 and comprising with the following standard fittings/Technical specifications with necesary civil work for foundation as per manufacture recommendation complete all as specified and as directed by Engineer-in-charge
Notes:- (i) The transformer shalll be provided with cable box on both HT and LT side (ii) Precommissioning test of transformer shall be done by SEI with out extra cost (a) Lifting lug for transformer and tank (b) Earthing terminal rating and diagram plate (c) Air release device (d) Oil filling inlet pipe with plug. (e) Drain outlet pipe with brass gate valve (f) Conservator tank with oil level indicator (g) Silica Jel breather (h) First fill of oil upto level including conservator lank with fresh new oil conforming to IS 335 (j) Type of connection Delta/Star (k) Type of cooing and Natural Air (l) Vector group DYN 11 (m) Temperature rise over an ambient of 50 "C maximum (n) Cable end box on both side for HT/LT cables of suitable size (o) Provision of thermometer with pocket (p) Provision of oil and winding temperature gauge
(iii) Transformer shall be over the plate form of size not less than 3 m (Length) X3 m (Width) X1.5 m (height) above ground level made by PCC 1:3:6, as mass filing and PCC 1:2:4 at top with 30 cm thickness Civil work required for installation of transformer deemed to be included under quoted rates (iv) Contractor shall submit the technical drawing, Constructional drawings, safety features drawing etc for approvel of accepting officer. (v) The contractor shall intimate for factory inspection for routine tests as per IS and ANSIC-57 12. 90 (Latest revision) in the OEM factory in presence of rep nominated by Accepting Officer before despatch from factory .Test after installation shall also be camed out SEI for which GE wit mate through proper channel.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 sqmm complete all as specified and as directed
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 sqmm complete all as specified and as directed
Supply and fix cable jointing kit for 11 KV grade cable for straight through joint , heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 sqmm complete all as specified and as directed
Supply & Lay , Testing and Commissioning HT 11KV XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade , 3 core 95 sqmm laid in trenches or ducts / fixed on walls /inside panel drawn through pipe and connecting up complete all as specified and as directed.
Supply & Lay , Testing and Commissioning LT 1100 Volts XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor , 3.5 core 300 sqmm laid in trenches or ducts / fixed on walls /inside panel drawn through pipe and connecting up complete all as specified and as directed. Note for Item Nos.6 & 7:- (i) Excavation,earthwork and sand cushioning shall be measured and paid separately.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6 mm thick buried directly in ground earth pit not less than 2.25 m deep below the ground level with top edge of the plate n. less than 1.5 m below ground level connected to GI strip 32 x 6 mm by means of bolts,nuts,check nuts and washers of galvanised steel including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and chamber RCC cover and light grade GI pipe 50 mm dia of required length for protection of GI strip and water funnel and wire mesh with GI pipe medium grade 20 mm dia etc complete all as per electrical plate No. 3 of SSR Part-I and as directed including connections and testing on completion all as specified and as directed. Note: GI strip of size 32 x 6 mm up to 7.5 m height is deemed to be included under quoted rate
M&L for earthing complete with copper earth plate electrode of size 60cm x 60cm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 m deep below the ground level with top edge of the plate n. less than 1.5 m below ground level connected to copper strip 20 x 3 mm by means of bolts,nuts,check nuts and washers of galvanised steel including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and chamber RCC cover and light grade GI pipe 50 mm dia of required length for protection of GI strip and water funnel and wire mesh with GI pipe medium grade 20 mm dia etc complete all as per electrical plate No. 3 of SSR Part-I and as directed including connections and testing on completion all as specified and as directed. Note: Copper strip of size 20 x 3 mm up to 7.5 m height is deemed to be included under quoted rate
Supply, Install ,testing and commissioning of LT Feeder pillar Box AC 415 V, 50 HZ ,3 Phase, 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure/cubicle, fully compartmentalized type, weather proof, protection IP 55, suitable for outdoor use, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet of suitable size with angle iron frame work and legs of ISA 50x50x5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover switch and MCCBs, with sloping canopy at top, double hinged doors at front with suitable locking arrangement structure treated under 8-tank metal treatment process and duly powder coated, complete and comprising of the following all as specified and as directed
BUSBAR:- Copper-bus bar having current raung of 900 Amps, 440 volts supported on non hygroscopic fibres and brass screws for mounting-04 Nos INCOMER:- (a) Supply and fixing MCCB 4 pole 440 Volts of 630 Amps Microprocessor release 50KA-01 Nos INDICATING DEVICES:- (a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y.B - 03 Nos (b) Supply and fixing multi function meter, incl CT having CTR 50/5-01 No (Parameters V, A, F, PF ,kW, KVA, KWN, KVAh, KVARH) OUTGOING FEEDERS:- (a) Supply and fixing MCCB 4 pole 440 Volts of 250 Amps Microprocessor release 50 KA - 03 Nos
Supply ,install, testing and commissioning of outdoor type Automatic Power Factor Correction (APFC) Panel of capacity 250 KVAR with auto / manual operation suitable for improving PF up to unity ,made out of CRCA Sheet of suitable thickness confirming to IS-375 CPRI Approved factory made, duly pretreated and powder coated finish and IP 54 and IS 8623 protection with cable alley suitable for three phase 415 volts, 50 HZ system including all necessaries and comprising and provision of the MCCB 4 pole ,400 amps, Capacitor duty contactor, Digital micro processor based PF correction relay and 250 KVAR capacitor bank with 6 steps consisting of MPP-H model capacitors of capacity (2 x 50 + 2 x 25 + 4 x 25 ) complete all as specified and as directed
Excavation in post holes (or similar holes ) each not exceeding 0.50 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around , in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface, in soft/loose soil.
M&L for plain cement concrete type B 2, 1:2:4 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed
S&F MS angle iron post with Y or swan neck & strut etc in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, MS flat iron fillets for securing wire mesh: MS flat iron clamp for securing strut with post including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed
M&L for 75 mm thick cement concrete type C2 1:3:6 (40 mm graded aggregate), as in sub base floorings complete all as specified and as directed
M&L for pre-cast cement concrete block masonry type C-5 , 20mm graded stone aggregate with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6, complete all as specified and as directed
S&F MS galvanned chain link fencing, including line wire mesh size any type of standard rails straining bolts etc, including provision of binding wire complete all as specified and as directed
S&F Mild steel TMT bars (CRS) 10 mm dia and over cut to length and bent to shape as reqd, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia complete all as speified and as directed
S&F mild steel screws bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends , each screwed end to be fitted with washers and one hexagonal or square nut , exc 5 cm long and diameter of shank 5 to 10 mm complete all as specified and directed .
Excavation in trenches not exc. 1.5 m in depth and not exceeding 1.5 m wide in soft loose soil for laying of under ground cable / GI piping complete all as specified and as directed
Excavation in trenches not exc. 1.5 m in depth and not exceeding 1.5 m wide in soft/ disintegrated rock / laterite rock for laying of under ground cable / GI piping complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/disintegrated rock all as specified and as directed
Removal of surplus excavated surplus soil to a distance not exceedng 50 M and depositing where directed at a level not exceeding 1.5 M from the starting point all as specified.
Supply and laying in trenches clear sand for cushioning under ground cable 8cm below and 15 cm above complete in level complete all as specified and as directed Note: Punned down thickness shall be measured and paid.
Supply and lay PCC cable cover class HV, type I, flat size 300 mm x 180 mm x 40mm in trenches to protect under ground cable complete all as specified and as directed
S& F GI pipe light grade of 100 mm for cable protection in trenches / at PCC poles for loop in / loop out of cable and cable entry at panel / equipment end complete all as specified and as directed
S& F GI pipe light grade of 150 mm for cable protection in trenches / at PCC poles for loop in / loop out of cable and cable entry at panel / equipment end complete all as specified and as directed
M&L for PCC type D-2 , 1:4:8 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete for pole foundation and stay assembly etc complete all as specified and as directed.
BRITE INDUSTRIES
Bharat Sales Corporation
S and G Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .