| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹18.6 L+₹1.5 L (8.54%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN L1 | |
| 3 | L3₹18.9 L+₹1.8 L (10.3%)Rejected-AOC 97 ABROL NAGAR PATHANKOT 145001 PB | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-AOC OTHER THAN L1 | |
| 4 | L4₹20.0 L+₹2.9 L (17.0%)Rejected-AOC NEAR CIVIL HOSPITAL VILLAGE PO CHOWARI DISTT CHAMBA HP | CHOWARI | CHAMBA | HIMACHAL PRADESH | 176302 | L4 | Rejected-AOC OTHER THAN L1 |
Tender Value
₹20.4 L
EMD Value
₹40,800
Closing Date
18 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE YOL
HQ CWE YOL CANTT
PROVN OF ADDN/ALTR TO BUILDING NO HT-11 AT BHARATPUR LINE UNDER AGE(I) DHARAMSHALA
2022_MES_509105_1
CWE/Y-83/2021-22
Open Tender
Civil Works
Item Rate
180 days
DHARAMSHALA
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
AGE (I) DHARAMSHALA
₹40,800
Yes
25 Apr 2022
18 Feb 2022
25 Mar 2022
18 Feb 2022
18 Mar 2022
5 Mar 2022
60 days
Amount
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thick above or below ground level complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Demolition of brick work or stonework built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings ,dressed stonework and precast concrete articles and stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Taking down cement plaster including backing etc from brick/stone walls / concrete surfaces including raking out joints, hacking for key , scrubbing down with water etc complete all as specified and directed
Taking down and removing chowkats with shutters (without taking off shutters from chowkat) exc 1.50 Sqm but not exc 4.00 Sqm each complete all as specified and directed.
Demolition of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
Dismantling framed steel trusses of span exceeding 10m and not exceeding 15m complete all as specified and directed.
Dismantling plain or corrugated steel sheets any gauge thickness including Nanital or similar pattern roof covering including ridges complete all as specified and directed.
Dismantling timber in scantling 40 sqcm and over in section framed work complete all as specified and directed.
Brick work with old size fly ash bricks, class 7.5, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:6 all as specified & directed.
Powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing of glass, particle board,aluminium frame etc complete all as specified and directed.
Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per the directions of Engineer-in-Charge.
Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per the directions of Engineer-in-charge.
Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.
Aluminium handles cast type anodized of size 100 mm complete all as specified and directed.
Aluminium handles cast type anodized of size 200 mm complete all as specified and directed.
Aluminium anodized barrel tower bolt of extruded section of size 125 mm and fixed complete all as specified and directed.
Aluminium anodized barrel tower bolt of extruded section of size 200 mm and fixed complete all as specified and directed.
250mm long aluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
Galvanished mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanished wire staples complete all as specified and directed.
Sheet glass, 5.5mm thick ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed.
Aluminium anodised snap grid frame work of size of size 605 mm X 605 mm as in false ceiling, flat or sloping (pattern as per manufacturer's catalogue/ instructions), cutting holes for electrical fittings fixed on and including aluminium tee of size 25mmX25mmX1.50 mm as main runner, aluminium tee of size 25mmX25mmX1.25 mm as cross runner and aluminium angle of size 25mmX25mmX1.25mm at the perimeter suspended from soffit at approx 900 mm centre to centre with hangers 6 mm dia galvanised (length as per site requirement) adjusting level fixed to roof by means of ceiling cleats made out of galvanised iron flat 40 mm X 3 mm size, 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm long including necessary scaffolding all as specified and directed.
9mm thick, high pressure stream cured fibre cement pre-primered textured variant E- board classic, ISI marked is 14862-2000 as in ceiling fixed or laid/ inserted to timber/ GI/ aluminium frame work fixed complete all as specified and directed.
2nd class soft wood, clean sawn timber framed and fixed as in scantling complete all as specified and directed.
Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed.
Prepainted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge, hips, valley/ eaves/ rain water gutters, drip and straight flashing (length and girth as fixed), fixed with self tapping screws all as specified
Plain cement concrete 1:3:6, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 50mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved).
Vitrified ceramic tiles (light shade) 10mm thick (square/rectangular) polished, area of each tile not exceeding 0.36 sqm as directed by EIC, as in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
Glazed ceramic coloured tiles of size 450mm x 300 mm x 7mm thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:4 complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the GE.
Marble work 15 to 18mm thick (Green Marble) (table rubbed and polished) in steps,skirting, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over and including 15 mm thick screed base in cement mortar 1:6 over and complete all as specified and directed.
Rendering cement plaster 15mm thick in cement mortar 1:6 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
Removing old white wash/ cement base paint, raking out joints and washing with water and rendering cement plaster 15mm thick in cement mortar 1:4 on brick wall surfaces, surface finished even and smooth without using extra cement, all as specified.
Preparation of wooden surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Preparation of newly plastered or un plastered, previously undecorated wall surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over and including a coat of 2 mm thick wall care putty complete, all as specified and as directed by Engr-in-Charge
Taking down point wiring with aluminium/ copper conductor for light point, socket point/ power point etc. in PVC casing and caping, surface pvc/ steel conduits, wood batten with clips including taking down board any type and size complete with any type of switches, sockets, holders, (batten or pendent type), ceiling rose etc. The light fittings (any type), main switches, distribution board with MCB’s of any capacity and make are to be removed/ replaced if required and all as specified and directed. NOTE: - Existing fan regulator any type (Where required) and electric meters are to be refixed and connected properly where required.
Point wiring with 1.5 Sqmm copper conductor FRLS (Multistrand) PVC insulated ISI Marked unsheathed cable in and including PVC casing and caping of suitable size (as per conductor run) with all fittings/ accessories as specified in preamble 1 (a) to (q) of Section 19 of SSR Part-II, under heading point wiring and also including PVC insulated ISI marked unsheathed 1.5 Sqmm copper multistranded conductor FLRS as earth wire (green colour) connected to common earth dolly and including pressed steel terminal boxes made out of 1.20 mm thick mild steel sheet duly painted with one coat of red oxide primer for mounting of switches, sockets, fan regulators, light fittings etc. covered with 3mm thick plastic laminated sheet (Make Hylum or equivalent ISI marked) for one light point or one fan point or one fan point through regulator or one bell point, controlled by one way switch/ push button complete including making good disturbed surfaces to match with existing all as specified and directed.
All as per serial item No '37' above, but for one 3 pin 5 Amps socket outlet on the same board all as specified and directed.
All as per serial item No '37' above, but for one 3 pin 5 Amps socket outlet, independent all as specified and directed.
All as per serial item No. '37' above but for 3 pin 15 Amps socket out let independent with 2.5 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.
Switch piano flush type, single pole, one way, 5 Amps, all as specified.
Switch piano flush type, single pole, one way, 15 Amps, all as specified.
Socket outlet, 2 in 1, 3 pin, 5 Amp flush type, all as specified.
Socket outlet, 2 in 1, 5 Pin, 5/15 Amp ,flush type, multipurpose, complete all as specified.
Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified.
LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. complete all as specified and directed.
Exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as directed.
Universal batten for LED tube light fitting suitable for indoor applications type alongwith 18 Watts ultra bright glass LED tubelight with very high efficacy complete with all accessories and fixtures prewired and making connection with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light fixed in repair complete all as specified and as directed . Make : Havell's Cat Part No. REGALBATTENT5UPTO01X18WDSBSWH & CRYSTAL 1213T8DSTL18WLED865SGLASS or equivalent in makes mentioned PS.
10 Watts, surface and wall mounted LED batten (2 Feet), extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driveralong with LED tube 10 watts, complete with all accessories and fixtures prewired and making connection with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light complete. Make : Havell's Cat Part No. ENDURALINEARNEOBS10WLED865SPCWH or equivalent in makes mentioned PS.
MCB TPN 100 Amps (01 incoming & 06 outgoing), 415 Volts, 10 KA all as specified.
MCB SPN 32 Amp, 240 Volts, 10 KA all as specified.
MCB SP 6 to 32 Amp, 240 Volts, 10 KA all as specified.
Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 12 way, double door, 240 volts with 200 Amp rated bus bar completed all as specified.
Renewal of sheet metal enclosures for DBs when MCBs to be used, triple pole and neutral, 4 way, double door, 415 volts with 200 Amp rated bus bar including taking down ICDP/ DB's any type, kit kat fuse, MCB's any type, all as specified.
LED street light fitting, 35 W, Energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistance of IK07 complete fixed on pole/ wall with and including bracket made out of galvanised iron pipe 40mm dia, medium grade of length 1.50 metres with two clamps made out of mild steel flat 25x4 mm with nuts, bolts and washers complete accesseries including two coats of aluminium paint after preparation of surfaces including making connection with aluminium PVC insulated copper wire 2.5 sqmm as required at site and connecting the same to the cable with the help of the connector all as specfied and directed .
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in hard and dense soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed.
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed. Note: Punned thickness shall be measured.
Sub class "B" bricks for covering to cable laid dry flat, with width equal to length of bricks all as specified and directed.
GI pipe light grade of size 40 mm dia laid in trenches/ walls including clamps, screws etc, complete all as specified and directed.
Renewal of sub main wiring with two single core PVC insulated cable 1100 volts grade with copper stranded FRLS conductor of size 6 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire of size 6 Sqmm and drawn into PVC conduit/ casing & capping with all fittings/ accessories, junction boxes 1 to 4 way 20mm dia, cutting chases, making good in cement mortar (1:3), finishing surfaces to match with existing and connected to common earth dolly including taking down old unservicable submain wiring, complete and as directed. Note :- Two run (each run of 1 RM) of 6 sqmm copper conductor and one RM of earth wire of 6 Sqmm, shall be measured as one RM).
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm, 3.5 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC (1:2:4), type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC (1:2:4), type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 24 of tender doucments.
VIJAY KUMAR LAKHNI
Eshaan Construction Co.
m/S Varun Gupta
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .