| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹33.1 L+₹57,100 (1.76%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹39 L+₹6.5 L (20.1%)Rejected-Finance 111 YADAV ELECRIC MARKET GB MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | L3 | Rejected-Finance Being L3 |
| Sl No | Description | Qty | Unit | M K Engineers and Contractors L2 | Industrial Traders L3 | M/S S.B. Singh and Sons L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply Installation testing and commissioning of digital soft starter panel for 20 HP motor the rating should be 42 A suitable for voltage range 200-525 Volt AC (10% variation) with built-in bypass contactor and short circuit protection. Start, Stop, Reset PB, RYB, Run and Trip Indication Indication. The soft starter Enclosure switch boards shall be manufactured in accordance with switchgear OEM design guidelines, ensuring full compliance with IEC 61439 standards. The type test certification shall be done by OEM, and franchisee shall carry out assembly as per type tested design. To ensure compatibility, both the panel design and the switchgear components (MCCB / Control gear / Softstarter / VFD etc) should be from same OEM. The type of designation and certification label on the panel shall prominently feature the OEM's name. The panel shall be dust and vermin proof, indoor type made of 2 mm CRCA MS sheet, over all powder coated finish, front opening type, with aprons for cable entry, and fixing danger notice plate made of 1.6 mm thick mild steel sheet, vitreous enamelled white, of size 20 x 15 cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with, internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 10 Sqmm. | 1 | Each Job | 1,80,300 ₹1,80,300 | 2,20,000 ₹2,20,000 | 1,76,000 ₹1,76,000 Lowest |
| 1.02(A) Soft starter Technical Specifications: (a) Soft Starter 3 phase controlled, xS4000, 42A, M:200-525 VAC, C:110 / 220 VAC for 20 HP Pump. (b) No of Starts per Hour-6, Amb Tem p:50 degree centigrade (c) Main Voltage Range 200 to 525 V ac (+/-10%), Built-in bypass contactor, Control voltage 110 V to 240 VAC (+10% /-15%) & optional 24 VAC / VDC (+/-20%). (d) DI-Fixed = 2 Nos (Start / Stop & Reset) Programmable = 2 Nos, Digital Outputs -3 Nos (Relay), AO-1 Nos. (e) Rated impulse withstand voltage - 6KV, Rated insulation - 600 VAC to earth (f) Pollution Degree 3 , Communication port – optional, Full graphical LCD display, Real language feedback messages (g) Multi-languages support (8 Nos), Real time graphs of motor operating performance, Main Menu and Quick Setup, Logs: 384 events (h) EMC Emissions - IEC 60947-4-2 Class B, CE Compliance-IEC 60947-4-2 | ||||||
| 1.03(B) Soft starter Features (a) XLR-8 Adaptive: Start / Stop Adaptive Control for better pump control in xS4000 soft starter, Profiles for common applications, starting methods of Constant Current, Current Ramp, Timed voltage ramp soft stop (b) Coast to Stop, DC Brake, Soft Brake, Real time performance graphs, Energy Efficient by supporting IE3 motors, Versatile starting & stopping options (c) Power Through function, Emergency Run (Fire Mode), Built-in Simulation Mode, USB port for easy and fast commissioning and data extraction | ||||||
| 1.04(C) Motor Protection features: (a) Motor overload, Excess start time(stall), Undercurrent, Instantaneous overcurrent (b) Phase loss, Phase Sequence, Undervoltage, Overvoltage, Motor Connection fault (c) Current imbalance, External trip (x2), Motor thermistor, Shorted SCR, Power loss (d) Supply frequency, Network communications, Heatsink over-temperature (e) Batter / clock failure, Bypass overload, Control supply | ||||||
| 1.05(D) ANCILLARY FUNCTIONS: (a) Jog, Emergency Mode, Dual Motor Sets, Inside Delta Operation, (b) Motor Reverse Control, Restart Delay: Anti-backspin (c) Power-Through Mode, Second Motor Set, Auto Reset (d) Pump Clean, Run Timers, Weekly Scheduling (e) Auto-Start / Stop Soft Brake Control Simulation Tools | ||||||
| 1.06(E) Semiconductor Fuse (a) Type-2 Coordination with semiconductor fuses should be followed, Bussman 170M3013 or Suitable rating semiconductor fuse along with mounting mechanism for soft starter should be used. | ||||||
| 2.00 | Supply Installation Testing and commissioning of digital soft starter panel for 25 HP motor the rating should be 52 A suitable for voltage range 200-525 Volt AC (10% variation) with built-in bypass contactor and short circuit protection. Start, Stop, Reset PB, RYB, Run and Trip Indication Indication, The soft starter Enclosure switchboards shall be manufactured in accordance with switchgear OEM design guidelines, ensuring full compliance with IEC 61439 standards. The type test certification shall be done by OEM, and franchisee shall carry out assembly as per type tested design. To ensure compatibility, both the panel design and the switchgear components (MCCB / Control gear / Softstarter / VFD etc) should be from same OEM. The type of designation and certification label on the panel shall prominently feature the OEM's name. The panel shall be dust and vermin proof, indoor type made of 2 mm CRCA MS sheet, over all powder coated finish, front opening type, with aprons for cable entry, and fixing danger notice plate made of 1.6 mm thick mild steel sheet, vitreous enamelled white, of size 20 x 15 cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with, internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 10 Sqmm. | 16 | Each Job | 1,95,300 ₹31,24,800 | 2,30,000 ₹36,80,000 | 1,92,000 ₹30,72,000 Lowest |
| 2.01(A) Soft starter Technical Specifications: (a) Soft Starter 3 phase controlled, xS4000, 52A, M:200-525VAC, C:110 / 220VAC for 25 HP Pump, (b) No of Starts per Hour-6, Amb Temp: 50 degree Centigrade. (c) Main Voltage Range 200 to 525 Vac (+/-10%), Built-in bypass contactor, Control voltage 110 V to 240 VAC (+10% /-15%) & optional 24 VAC / VDC (+/-20%). (d) DI-Fixed = 2 Nos (Start / Stop & Reset) Programmable = 2 Nos, Digital Outputs -3 Nos (Relay), AO-1 Nos. (e) Rated impulse withstand voltage - 6KV, Rated insulation- 600 VAC to earth (f) Pollution Degree 3, Communication port – optional, Full graphical LCD display, Real language feedback messages. (f) Multi-languages support (8 Nos), Real time graphs of motor operating performance, Main Menu and Quick Setup, Logs: 384 events (g) EMC Emissions -IEC 60947-4-2 Class B, CE Compliance-IEC 60947-4-2 | ||||||
| 2.02(B) Soft starter Features (a) XLR-8 Adaptive: Start / Stop Adaptive Control for better pump control in xS4000 soft starter, Profiles for common applications, starting methods of Constant Current, Current Ramp, Timed voltage ramp soft stop (b) Coast to Stop, DC Brake, Soft Brake, Real time performance graphs, Energy Efficient by supporting IE3 motors, Versatile starting & stopping options (c) Power Through function, Emergency Run (Fire Mode), Built-in Simulation Mode, USB port for easy and fast commissioning and data extraction | ||||||
| 2.03(C) Motor Protection features: (a) Motor overload, Excess start time(stall), Undercurrent, Instantaneous overcurrent (b) Phase loss, Phase Sequence, Undervoltage, Overvoltage, Motor Connection fault (c) Current imbalance, External trip (x2), Motor thermistor, Shorted SCR, Power loss (d) Supply frequency, Network communications, Heatsink over-temperature (e) Batter / clock failure, Bypass overload, Control supply | ||||||
Tender Value
₹37.9 L
EMD Value
₹75,720
Closing Date
14 Jan 2026, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
SPL REPAIR FOR REPLACEMENT OF SOFT STARTER AND CONNECTED ITEM AT WATER SUPPLY INSTALLATION AT VARIOUS LOCATIONS UNDER GE (E/M) LUCKNOW
2025_MES_745952_1
GE/EM/LKO/EXT(WS)/T-50 OF 2025-2026
Open Tender
Miscellaneous Works
Item Wise
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹75,720
Yes
13 Mar 2026
24 Dec 2025
16 Jan 2026
24 Dec 2025
14 Jan 2026
7 Jan 2026
Supply Installation testing and commissioning of digital soft starter panel for 20 HP motor the rating should be 42 A suitable for voltage range 200-525 Volt AC (10% variation) with built-in bypass contactor and short circuit protection. Start, Stop, Reset PB, RYB, Run and Trip Indication Indication. The soft starter Enclosure switch boards shall be manufactured in accordance with switchgear OEM design guidelines, ensuring full compliance with IEC 61439 standards. The type test certification shall be done by OEM, and franchisee shall carry out assembly as per type tested design. To ensure compatibility, both the panel design and the switchgear components (MCCB / Control gear / Softstarter / VFD etc) should be from same OEM. The type of designation and certification label on the panel shall prominently feature the OEM's name. The panel shall be dust and vermin proof, indoor type made of 2 mm CRCA MS sheet, over all powder coated finish, front opening type, with aprons for cable entry, and fixing danger notice plate made of 1.6 mm thick mild steel sheet, vitreous enamelled white, of size 20 x 15 cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with, internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 10 Sqmm.
(A) Soft starter Technical Specifications: (a) Soft Starter 3 phase controlled, xS4000, 42A, M:200-525 VAC, C:110 / 220 VAC for 20 HP Pump. (b) No of Starts per Hour-6, Amb Tem p:50 degree centigrade (c) Main Voltage Range 200 to 525 V ac (+/-10%), Built-in bypass contactor, Control voltage 110 V to 240 VAC (+10% /-15%) & optional 24 VAC / VDC (+/-20%). (d) DI-Fixed = 2 Nos (Start / Stop & Reset) Programmable = 2 Nos, Digital Outputs -3 Nos (Relay), AO-1 Nos. (e) Rated impulse withstand voltage - 6KV, Rated insulation - 600 VAC to earth (f) Pollution Degree 3 , Communication port – optional, Full graphical LCD display, Real language feedback messages (g) Multi-languages support (8 Nos), Real time graphs of motor operating performance, Main Menu and Quick Setup, Logs: 384 events (h) EMC Emissions - IEC 60947-4-2 Class B, CE Compliance-IEC 60947-4-2
(B) Soft starter Features (a) XLR-8 Adaptive: Start / Stop Adaptive Control for better pump control in xS4000 soft starter, Profiles for common applications, starting methods of Constant Current, Current Ramp, Timed voltage ramp soft stop (b) Coast to Stop, DC Brake, Soft Brake, Real time performance graphs, Energy Efficient by supporting IE3 motors, Versatile starting & stopping options (c) Power Through function, Emergency Run (Fire Mode), Built-in Simulation Mode, USB port for easy and fast commissioning and data extraction
(C) Motor Protection features: (a) Motor overload, Excess start time(stall), Undercurrent, Instantaneous overcurrent (b) Phase loss, Phase Sequence, Undervoltage, Overvoltage, Motor Connection fault (c) Current imbalance, External trip (x2), Motor thermistor, Shorted SCR, Power loss (d) Supply frequency, Network communications, Heatsink over-temperature (e) Batter / clock failure, Bypass overload, Control supply
(D) ANCILLARY FUNCTIONS: (a) Jog, Emergency Mode, Dual Motor Sets, Inside Delta Operation, (b) Motor Reverse Control, Restart Delay: Anti-backspin (c) Power-Through Mode, Second Motor Set, Auto Reset (d) Pump Clean, Run Timers, Weekly Scheduling (e) Auto-Start / Stop Soft Brake Control Simulation Tools
(E) Semiconductor Fuse (a) Type-2 Coordination with semiconductor fuses should be followed, Bussman 170M3013 or Suitable rating semiconductor fuse along with mounting mechanism for soft starter should be used.
Supply Installation Testing and commissioning of digital soft starter panel for 25 HP motor the rating should be 52 A suitable for voltage range 200-525 Volt AC (10% variation) with built-in bypass contactor and short circuit protection. Start, Stop, Reset PB, RYB, Run and Trip Indication Indication, The soft starter Enclosure switchboards shall be manufactured in accordance with switchgear OEM design guidelines, ensuring full compliance with IEC 61439 standards. The type test certification shall be done by OEM, and franchisee shall carry out assembly as per type tested design. To ensure compatibility, both the panel design and the switchgear components (MCCB / Control gear / Softstarter / VFD etc) should be from same OEM. The type of designation and certification label on the panel shall prominently feature the OEM's name. The panel shall be dust and vermin proof, indoor type made of 2 mm CRCA MS sheet, over all powder coated finish, front opening type, with aprons for cable entry, and fixing danger notice plate made of 1.6 mm thick mild steel sheet, vitreous enamelled white, of size 20 x 15 cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with, internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 10 Sqmm.
(A) Soft starter Technical Specifications: (a) Soft Starter 3 phase controlled, xS4000, 52A, M:200-525VAC, C:110 / 220VAC for 25 HP Pump, (b) No of Starts per Hour-6, Amb Temp: 50 degree Centigrade. (c) Main Voltage Range 200 to 525 Vac (+/-10%), Built-in bypass contactor, Control voltage 110 V to 240 VAC (+10% /-15%) & optional 24 VAC / VDC (+/-20%). (d) DI-Fixed = 2 Nos (Start / Stop & Reset) Programmable = 2 Nos, Digital Outputs -3 Nos (Relay), AO-1 Nos. (e) Rated impulse withstand voltage - 6KV, Rated insulation- 600 VAC to earth (f) Pollution Degree 3, Communication port – optional, Full graphical LCD display, Real language feedback messages. (f) Multi-languages support (8 Nos), Real time graphs of motor operating performance, Main Menu and Quick Setup, Logs: 384 events (g) EMC Emissions -IEC 60947-4-2 Class B, CE Compliance-IEC 60947-4-2
(B) Soft starter Features (a) XLR-8 Adaptive: Start / Stop Adaptive Control for better pump control in xS4000 soft starter, Profiles for common applications, starting methods of Constant Current, Current Ramp, Timed voltage ramp soft stop (b) Coast to Stop, DC Brake, Soft Brake, Real time performance graphs, Energy Efficient by supporting IE3 motors, Versatile starting & stopping options (c) Power Through function, Emergency Run (Fire Mode), Built-in Simulation Mode, USB port for easy and fast commissioning and data extraction
(C) Motor Protection features: (a) Motor overload, Excess start time(stall), Undercurrent, Instantaneous overcurrent (b) Phase loss, Phase Sequence, Undervoltage, Overvoltage, Motor Connection fault (c) Current imbalance, External trip (x2), Motor thermistor, Shorted SCR, Power loss (d) Supply frequency, Network communications, Heatsink over-temperature (e) Batter / clock failure, Bypass overload, Control supply
(D) ANCILLARY FUNCTIONS: (a) Jog, Emergency Mode, Dual Motor Sets, Inside Delta Operation, (b) Motor Reverse Control, Restart Delay: Anti-backspin (c) Power-Through Mode, Second Motor Set, Auto Reset (d) Pump Clean, Run Timers, Weekly Scheduling (e) Auto-Start/Stop Soft Brake Control Simulation Tools
(E) Semiconductor Fuse (a) Type-2 Coordination with semiconductor fuses should be followed, Bussman 170M3013 or Suitable rating semiconductor fuse along with mounting mechanism for soft starter should be used.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
BOQ_835261.xls
BOQ • 0.40 MB
Tender50.pdf
Tender Documents • 1.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .