Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC 94A APR COLONY BILHARI JABALPUR MP | JABALPUR | MADHYA PRADESH | 482020 | ₹36.9 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹39.4 L+₹2.5 L (6.66%)Rejected-Finance | ₹39.4 L+₹2.5 L (6.66%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹41.5 L+₹4.6 L (12.5%)Rejected-Finance | ₹41.5 L+₹4.6 L (12.5%) | L3 | Rejected-Finance Not Lowest |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
13 Mar 2020, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
PROVISION OF SECURITY WALL WITH SOLAR FENCING AND APPROACH ROAD FOR NEWELY ACQUIRED 0.58 ACRES LAND AT DMDE AND PROVISION OF LIGHTNING CONDUCTOR AT DMDE OFFICE COMPLEX UNDER AGE B/R RND SECUNDERABAD
2020_MES_325574_1
GE I KBAGH TOKEN 85 OF 2019 2020
Open Tender
Civil Works
Item Rate
270 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹78,000
Yes
30 Mar 2020
15 Feb 2020
16 Mar 2020
15 Feb 2020
13 Mar 2020
29 Feb 2020
15 Feb 2020 - 21 Feb 2020
Amount
Excavating in trenches, n exc1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc., n.exc 10 sqm on plan and n exc 1.5 m in depth and getting out in Hard/dense soil complete all as directed
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as directed.
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as directed
M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, fillings and mass concrete complete all as directed
M&L for walling of random rubble masonry uncoursed, well bonded, beded and solidly hearted, brought upto courses built in CM 1:6 complete all as directed.
M&L for reinforced cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) as in foundations, including rafts,footings, foundation beams;plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as directed.
M&L for Reinforced cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as directed. Note: Use & waste of formwork & reinforcement shall be measured separately under relevant items of this BOQ.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as directed
All as per srl item No. 8 here-in-before but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders complete all as directed
M&L for raised pointing to random or polygonal rubble, uncoursed or brought upto courses in CM 1:3 complete all as directed
M & L for providing, plain cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate) as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses,parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs and the like including weathering, slightly rounded for chamfered angles and throating complete all as directed.
Returning, filling in including spreading, levelling watering and well ramming in layers n exc 25cm thick using soil complete all as directed
Removing of excavated surplus spoil to a distance exc., 1.50 km but n.exc. 5 km and depositing where directed
Use & waste of formwork to sides square, rectangular shaped columns, pillars, etc. for rough finished surfaces of concrete complete all as directed.
Use & waste of formwork to sides of concrete, foundations, footings, bases of coloumns, raft and raft beams, plinth beams and similar work and rough finished concrete surface complete all as directed
M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as directed.
M & L for preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed.
M&L for 150mm thick plain cement concrete 1:3:6, type C-2, (using 40mm graded stone aggregate) as in sub base complete all as directed.
M&L for machine pressed precast concrete PU coated interlocking paver block with grey cement and pigment of approved shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as directed.
M&L for sand cushion to floor tiles and consolidation for laying tiles complete all as directed.
M&L for Rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement)
M&L for preparation of new plastered or un-plastered surface of walls and applying two coats of exterior emulsion paint over a coat of primer on walls complete all as directed.
S&F Single Zone Energizer Model No CS: 250 /V3 with inbuilt alarm unit, controller and charger with necessary connecting up complete all as directed. MAKE :- CROWN SOLAR / HARPER CHALICE / GM
S&F External Hooter operated at 12V, DC, Range 150 meters complete all as directed. MAKE :- IOTA / SURAJ / KHERAJ
S&F AC Charger controller 6 Amps 12 Volts complete all as directed. MAKE :- CROWN SOLAR / HARPER CHALICE / GM
S&F 12V/65AH maintenance free dry battery with terminal lugs and jelly complete all as directed. MAKE :- EXIDE / AMRON
S&F Solar photovoltaic (PV) module 12V /74W with structure complete all as directed
S & F fence live light, one side visibility with super bright LED's with suitable choke and necessary connecting up complete all as directed.
S&F lightening diverter kit with suitable necessary connecting up complete all as directed. Make for srl item Nso. 26 to 28 :- CROWN SOLAR / HARPER CHALICE / GM
Out door type console rack made out of CRCA sheet 3mm thick of size 760mm x 760mm x 300mm made up of sheet steel surface finish enclosure and door dipcoat-primed, powder-coated in textured RAL 7035 on the outside mounting plate zinc plated IP-66, single door, door hinge with 2 cam locks fixed on suitable size angle iron at minimum 1metre height, interconnectivity cable for routing etc for housing Energizer - 02 Nos, Network switch-01 No, SMF Battery, UPS and MCB including control wiring with and including provision of Solar Photovoltaic module 12 V / 37Wp crystalline module as per MNRE standard alongwith solar module pole of 4metre length 50 NB Class B pipe, galvanised, with suitable accessories for mounting to withstand 120 Kmph wind speed, including provision of solar charge controller of 12V / 5Amps rating having overcharge and battery cut off features & short circuit protection, complete all as directed. NOTE:- (i) Energizer, Network switch, SMF Battery, UPS shall be measured and paid separetely under respective items of this Schedule. (ii) Control / power wiring between various items shall deemed to be included in quoted rate of this item. MAKE:- CONSULE RACK-RITTAL / SOLAR P / CROWN/ MODULE & CONTROLLER - TATA BP.
S&F Intermediate posts 1.6mmx45mmx25mm thick MS pre-fabricated KiWITAH type duly galvanised of 4 feet length on wall including errection charges complete all as directed.
S&F Intermediate posts 1.6mmx45mmx25mm thick MS pre-fabricated KiWITAH type duly galvanised of 3 feet length on wall including pole errection charges complete all as directed.
M&L for fixing end/corner post assembly 2mm thick 40mm square hollow MS pole prefabricated duly galvanised, 4 feet length, on wall complete all as directed.
S&F end/corner post assembly 2 mm thick 40mm square hollow pipe prefabricated duly galvanised of 3 feet length, on wall complete all as directed.
S&F 25NB class B support pole duly galvanised of 4.5 feet length complete all as directed.
S&F intermediate fencing post insulators complete all as directed.
S&F end strain insulators in power fence with nylon material UV stabilized, capable to terminate wires upto 3mm dia including provision of suitable fixing material as required complete all as directed.
S&F end strain Hooks of 8mm dia in power fence as required complete all as directed
S&F GI joint clamps for power fence including MS bolts and nuts mechanism to connect two wires having Maximum 3mm dia with fixing arrangement, complete all as directed
S&F fine pitch wire strainer complete all as directed. Make for srl item Nos.30 to 39 :- CROWN SOLAR / HARPER CHALICE / GM
S&F GI Fencing wire of 2.59 mm dia duly laid on wall not more than 5metre height, 134 Kg/sqmm UTS, zinc coating, in compliance with IS: 398 Part-II, including fixing with provision of suitable fixing material, complete all as directed. MAKE:- TATA / JINDAL / ZENITH
S&F PVC double insulated 2 mm GI wire, outdoor dia of cable 9mm for more than 15 KV grade, including fixing with provision of suitable fixing materials, complete all as directed. MAKE:- KEI/RPG/INDOASIAN/ FINOLEX / GLOSTER/ HAVELLS
Warning sign board of 247mm x 147mm x 3mm polypropelene material with caution sign as per IEC 60335-2-76 standards having yellow background & black / red letters with size of about 10 mm in English / Hindi including fixing with provision of suitable fixing material, complete all as directed. MAKE:- CROWN SOLAR / HARPER CHALICE / GM
Supply & fixing XLPE cable insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables(heavy duty)with aluminum conductor of size 4 core 95sqmm.
M&L Earthing complete with GI earth plate electrode 600x 600 x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 m below ground level with the top edge at a depth of not less than 1.5m below ground connected to GI earth wire 4 mm dia by means of bolts, nuts, washers of GI or steel, GI earth wire shall be protected by 15mm bore GI pipe light grade, watering pipe 20mm bore GI pipe light grade, fixed with GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation, earth work, PCC (1:3:6) type C1 earth chamber, 15mm thick RCC cover (1:2:4) mix with 6mm dia nominal reinforcement @ 150mm c/c both way etc complete all as shown in Electrical Plate No. 3 connected to earthing test point complete including testing on completion all as directed.
M & L for Earth continuity conductor or main earthing of 4mm dia galvanised iron or steel wire lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated sityation for loop earthing etc.
M&L for preparation of new surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as directed
S&F Air termination vertical type single pointed aluminium rod 12mm dia 300mm long inclding necessary fixing arrangement with aluminium bolts, nuts, lead wasters etc. complete and including provisin of GI tubing medium grade 40mmdia, 300mm long embedded in PCC block (size 30cmx30cmx30cm) one end and other end fitted with air termination rod complete all as directed.
S&F aluminium strip of size 25 x 3.15mm horizontal down conductor for including epoxy insulator, bus bar type 40mm thick at an interwal of 60 cm apart for lightning protection on roof and for down conductors including all fixing arrangments with aluminium nuts, bolts & washers complete all as per IS-2309-1989 and testing complete all as directed. Note: i) Aluminium strip shall be jointed with rivets (minimum 4 Nos.) (ii) Necessary T&P, safety equipments deemed to be included in the quoted rates.
S&F test point terminal block made out of gun metal or phosphorus bronze of size 75 x 75 x 25mm drilled and screwed including 3 Nos 8 mm dia 25mm long hex head screw for fixing the same on wall complete all as directed
S&F Galvanised iron strip of size 32 x 6 mm from earth pit to test point provided all around the bldg for lightning protection laid in trenches /fixed to walls on epoxy insulators with screws etc., and connecting up complete all as directed.
Material and labour for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 mtrs below ground level with the top edge of earth plate at a depth of not less than 1.5 mtrs below normal ground level, connected to and including galvanised iron earth strip of size 32x6 mm with GI medium grade protection pipe of 40 mm dia for earth electrode upto test point or upto 7.5 mtr whichever is less, by means of bolts, nuts, check nuts and washers of galvanised iron including necessary excavation earth work in any type of soil, PCC pit (1:3:6) type C1 and RCC (1:2:4) type B1 as in cover of 40 mm thick with 8mm dia TMT bars @ 100mm c/c bothways, GI watering pipe 20 mm diamedium grade , wire mesh, funnel, lugs, charcoal, salt etc complete all as per electrical plate No. 3 or SSR Part-I complete all as specified and directed. Note: GI strip 32x6mm and GI pipe 40mm dia beyond 7.5 metres shall be measured and paid separately.
Brite electricals
M.R.ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .