Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 CrAccepted-AOC 5 217 D1 TEACHERS COLONY MOHANUR ROAD NAMAKKAL 637001 | NAMAKKAL | TAMIL NADU | 637001 | ₹20.0 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹21.7 CrRejected-Finance | ₹21.7 Cr | L2 | Rejected-Finance Other than Lowest bidder |
| 3 | L3₹22.9 CrRejected-Finance | ₹22.9 Cr | L3 | Rejected-Finance Other than Lowest bidder |
| 4 | L4₹26.3 CrRejected-Finance THOTTAPPALLY HOUSE EMILY KALPETTA P O KERALA 673121 | WAYANAD | KERALA | 673121 | ₹26.3 Cr | L4 | Rejected-Finance Other than Lowest bidder |
| 5 | L5₹32.0 CrRejected-Finance | ₹32.0 Cr | L5 | Rejected-Finance Other than Lowest bidder |
Tender Value
₹17.1 Cr
EMD Value
₹15 L
Closing Date
19 Nov 2022, 6:00 pmClosed
Chief engineer coast guard visakhapatnam
Office of Chief engineer coast guard Visakhapatnam-530007
PROVISION OF DEFICIENT MARRIED ACCOMODATION AT KARAIKAL
2022_MES_537409_1
CE (CG) /VIZ/KRKL/TOKEN 07 OF 2022-23
Open Tender
Civil Works
760 days
Karikal
As per tender documents
8 documents required · 8 mandatory
₹3,000
Garrison Engineer (I) (CG) Chennai
₹15 L
Yes
16 Jan 2023
12 Jul 2022
21 Nov 2022
12 Jul 2022
19 Nov 2022
7 Nov 2022
Amount
Schedule "A" Part – I to Schedule "A" Part – XIV:- NOTE: Schedule "A" Part – I to Part – XIII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lump Sum price worked out by the contractor for "BUILDINGS & STRUCTURES", for the lumpsum price of Rs. 148429153.35 inserted by MES as listed in Schedule 'A' Part - I on Serial Page No. 34 (R)
Price worked out by the contractor for "EARTH WORK, SITE CLEARANCE AND AREA DEVELOPMENT ", against the price of Rs. 1686633.44 inserted by MES as listed in Schedule 'A' Part - II on Serial Page No. 36 (R)
Price worked out by the contractor for "PILE WORK ", against the price of Rs. 17945040.00 inserted by MES as listed in Schedule 'A' Part - III on Serial Page No. 37 (R)
Price worked out by the contractor for "INTERNAL WATER SUPPLY", against the price of Rs. 1401761.92 inserted by MES as listed in Schedule 'A' Part - IV on Serial Page No. 40 (R)
Price worked out by the contractor for "INTERNAL ELECTRIC SUPPLY AND TV", against the price of Rs. 1377480.45 inserted by MES as listed in Schedule 'A' Part - V on Serial Page No. 43 (R)
Price worked out by the contractor for "EXTERNAL WATER SUPPLY", against the price of Rs. 684002.12 inserted by MES as listed in Schedule 'A' Part - VI on Serial Page No. 46 (R)
Price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY", against the price of Rs. 303329.29 inserted by MES as listed in Schedule 'A' Part - VII on Serial Page No. 47 (R)
Price worked out by the contractor for "AREA DRAINAGE", against the price of Rs. 1432447.13 inserted by MES as listed in Schedule 'A' Part - VIII on Serial Page No. 48 (R)
Price worked out by the contractor for "SEWAGE DISPOSAL", against the price of Rs. 12,31,288.06 inserted by MES as listed in Schedule 'A' Part - IX on Serial Page No. 52 (R)
Price worked out by the contractor for "ROAD/PATH/HARDSTANDING/CULVERT WORK", against the price of Rs. 2888862.30 inserted by MES as listed in Schedule 'A' Part - X on Serial Page No. 55 (R)
Price worked out by the contractor for "LIGHTENING PROTECTION AND OBSTRUCTION LIGHT WORK", against the price of Rs. 1,16,339.20 inserted by MES as listed in Schedule 'A' Part - XI on Serial Page No. 57 (R)
Price worked out by the contractor for "FIRE FIGHTING AND FIRE ALARM SYSTEM", against the price of Rs. 13,61,047.00 inserted by MES as listed in Schedule 'A' Part - XII on Serial Page No. 64 (R)
Price worked out by the contractor for "FENCING AND GATE", against the price of Rs. 431669.80 inserted by MES as listed in Schedule 'A' Part - XIII on Serial Page No.66 (R)
Schedule "A" Part - XIV [Miscellaneous Items]
INTERNAL WATER SUPPLY
Item No 1 :S&F two way bib cock with wall flange quarter turn (Low-flow) 16 mm dia. complete all as specified and directed by Engineer-in-Charge Make - Jaquar Model No KUP-35041PMGE or equivalent in Crab Tree/Kohler brand
Item No 2 :S&F bib cock with wall flange quarter turn (Low-flow) 16 mm dia. complete all as specified and directed by Engineer-in-Charge Make - Jaquar Model No KUP-35037PMGE or equivalent in Crab Tree/Kohler brand
Item No 3 :S&F Pillar Cock (Low-flow) 16 mm dia. complete all as specified and directed by Engineer-in-Charge Make - Jaquar Model No KUP-35001PMG or equivalent in Crab Tree/Kohler brand
Item No 4 :S & F Hand shower (Health faucet) with 1 meter long easy flex tube in chrome finish and wall hook with NRV (Back flow preventer) complete all as specified and directed by Engineer-in-Charge Make - Jaquar Model No ALD-579 or equivalent
Item No 5 :S & F Angular Stop Cock 15 mm bore of pipe (16 mm outer dia) with Wall Flange chromium plated Stop valves complete all as specified and directed. Make - Jaquar Model No KUP-35053PM or equivalent
Item No 5A :S & F angle stop valve of size 15mm cast copper alloy chroium plated of high pressure screwed for iron pipe and fixed, complete all as specified and directed
Item No 6 S & F Overhead Shower ø140mm Round Shape Single Flow with Air Effect (ABS Body & Face Plate Chrome Plated) with Rubit Cleaning System 16 mm dia. complete all as specified and directed by Engineer-in-Charge Make - Jaquar Model No OHS-1757GD or equivalent
Item No 7 S & F Wall Mixer with Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flanges complete all as specified and directed. Make - Jaquar Model No FUS-29273UPR or equivalent
Item No 7A S & F Chrome finish pillar cock contintal brass hole mixture, complete all as specified and directed. Make - Jaquar Model No CON-CHR-167KNB or equivalent
INTERNAL ELECTRIFICATION
(a) One light point/security light/ceiling/exhaust/wall mounted fan controlled by one switch
(b) One bell point controlled by one switch
(c) One 3 pin socket outlet , 5/6 Amps on an independent board controlled by one switch .
(d) One additional light point on the same board controlled by one switch .
(e) One 3 pin socket outlet , 5/6 Amps on same board controlled by one switch .
(f) One light point controlled by two switches single pole two way
Item No 9 : M & L for point wiring using 1.1 kV grade single core FR-LSH flexible cable 2.5 sqmm, conforming to IS 694: 2010, having multi-drawn thin strands of electrolytic copper conductors and insulation for phase, neutral, and earth continuity conductor connecting to earth dolly, colour-coded as per IS 11353: 1985, drawn in medium grade UPVC conceled conduits, conforming to IS 9537 (Part- 3): 1983, of size not less than 20 mm NB, including cutting chases, factory made not less than 1.2 mm thick sunken, modular flush sheet galvanized metal enclosure having zinc coating not less than 120 GSM, , conforming to IS 14772: 2000, having top, bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover-plates and making good of disturbed surfaces of wall / ceiling / floor, etc. complete all as specified in IS 732: 2019 and directed by the Engineer-in-Charge.
Item No 10 : M & L for point wiring using 1.1 kV grade single core FR-LSH flexible cable 4.0 sqmm, conforming to IS 694: 2010, having multi-drawn thin strands of electrolytic copper conductors and insulation for phase, neutral, and earth continuity conductor connecting to earth dolly, colour-coded as per IS 11353: 1985, drawn in medium grade UPVC conceled conduits, conforming to IS 9537 (Part- 3): 1983, of size not less than 20 mm NB, including cutting chases, factory made not less than 1.2 mm thick sunken, modular flush sheet galvanized metal enclosure having zinc coating not less than 120 GSM, , conforming to IS 14772: 2000, having top, bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover-plates and making good of disturbed surfaces of wall / ceiling / floor, etc. complete all as specified in IS 732: 2019 and directed by the Engineer-in-Charge.
Item No 11 : Modular type 3 pin 25/32 A socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 complete all as specified as directed.
Item No 12 : Vertical triple pole & neutral, double door, metallic modular distribution board, 6- Way conforming to IEC 61439-3, suitable for flush / surface mounting with provision for MCCB up to 250 A as incomer and SP/TP MCBs as outgoing, reversible metal door, fully insulated 250 A copper busbar for each phase, two fully insulated & shrouded neutral bars, two earthbars, cable ties for cable management, prefitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and as directed.
Item No 13 : MCB for AC applications 6- 32 A, 230 V, 50 Hz, SP MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. as specified in IS 732: 2019 all as directed.
Item No 14 : MCB for AC applications 6- 32 A, 230 V, 50 Hz, DP MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. as specified in IS 732: 2019 all as directed.
Item No 15 : MCB for AC applications 6- 32 A, 415 V, 50 Hz, TP MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. as specified in IS 732: 2019 all as directed.
Item No 16 : MCB for AC applications 40 - 63 A, 415 V, 50 Hz, TP MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. as specified in IS 732: 2019 all as directed.
Item No 17 : MCB for AC applications 6 - 32 A, 415 V, 50 Hz, Four Pole MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. as specified in IS 732: 2019 all as directed.
Item No 18 : MCB for AC applications 40 - 63 A, 415 V, 50 Hz, Four Pole MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. as specified in IS 732: 2019 all as directed.
Item No 19 : S & F of 100 A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 25 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply all as directed.
Item No 20 : Supply and fixing ceiling fans complete with blades, down rods, stepped type electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engineer-in-Charge.
Item No 21 : Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed by Engineer-in-Charge.
Item No 22 : Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed by Engineer-in-Charge.
Item No 23 : MCB modular type 6 to 32A SP MCB, conforming to IS 60898- 1: 2002 complete all as specified in IS 732: 2019 with all incoming / outgoing connections with proper size of copper lugs complete all as specified as directed. Note:(i) Cost of copper lugs shall be included in the unit rate.
Item No 24 : Supply and fixing LED lights fitting 1x 20W, 220V, AC with driver, including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete, 4 feet and luminous efficacy more than 120 lm/W with integrated sleek extruded polycarbonate Endura LED Channel available with 6500 K CDL with white acrylic cover and mounting accessories, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size from ceiling rose to fitting etc, Energy efficency not less than BEE 4 Star rating, complete all as specified and as directed.
Item No 25: Supply and fixing LED light fitting with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete, 2 feet and luminous efficacy more than 120 lm/W with integrated sleek extruded polycarbonate Endura LED Channel available with 6500 K CDL with white acrylic cover and mounting accessories,complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size from ceiling rose to fitting etc, Energy efficency not less than BEE 4 Star rating, complete all as specified and as directed.
Item No 26: MCB SPN 240 volts, 32A, C series, breaking capacity 10kA complete all as specified and as directed.
Item No 26 to Item No 27 : BLANK
Item No 28 : S & F surface / wall mounted LED batten capable of delivering 2000 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the Engineer-in-Charge. Make: Philips Cat-Part No. BN 021C LED20S- PSU CW GR S2 or equivalent model of Havells Cat-Part No. LHEXAPP7IN1W020 or Wipro Cat-Part No. LL20-281-XXX-65AL1
Item No 29 : S & F 3-star (EEL) T-shape lamp capable delivering 1000 lumen having luminous efficacy of > 100 lm/W, starting time < 0.5 s, CRI > 80, CCT 6500K, PF >0.9, input voltage range 140- 270 V, input frequency 50- 60 Hz and B22 socket complete all as specified and directed by the Engineer-in-Charge. Make: Philips Cat-Part No. T- Bulb CW 10W B22 or equivalent model of Havells Cat-Part No. LHEXACP7FN1W010 or Wipro Cat-Part No. LL20-111-XXX-65-NE
Item No 30 : S & F LED Bathroom light suitable for wall mounting & 220- 240 V, 50 Hz mains voltage with built-in LED & driver, power rating ≤ 8 W, including IP 20 protection as well as electrical connection with 3 core 1.0 mm² PVC insulated copper conductor unarmoured cable to the fixture complete all as specified and directed by the Engineer-in-Charge. Make: Philips Cat-Part No. 34034/14/86 or equivalent model of Havells Cat-Part No. LHLDEUECNL8R009
Item No 31 : S & F surface mounted round shape LED downlight capable of delivering 1200 lumen. having minimum luminous efficiency > 100 lumen/W, CCT 6500K, CRI > 80, high quality polycarbonate diffuser, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection complete all as specified and directed by the Engineer-in-Charge. Make: Philips Cat-Part No. SM250C LED12S- 6500 PSU WH or equivalent model of Havells Cat-Part No. LHEAABP7IL1W012 or Wipro Cat-Part No. LD80-101-XXX-60-SM
Item No 32 : S & F 25 W street light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of ≥ 2600 lumen/W, integral SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, IP 66 protection, high efficacy polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry, pole mounting with bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enamel paint over a coat of red oxide primer complete in all respect as specified and directed by the Engineer-in-Charge. Make: Philips BRP042 LED 26 CW MR S1 PSU GR or equivalent model of Havells Cat-Part No. ENDURAPEARLSL25W LED757 SASYTOPCMP or Wipro Cat-Part No. LR02-291-XXX-57-XX
Item No 38 : BLANK
Item No 39 : Supply and fix PVC insulated telephone cable 4P for indoor applications confirming to TEC specification G/WIR06/02, unarmoured 0.5mm ATC etc complete all as specified and as directed at site by the Engr-in-charge.
Item No 40 : Supply and fix PVC insulated co-axial cable for indoor applications for TV complete all as specified and as directed at site by the Engr-in-charge.
Item No 41 : Supply and fix RJ 11 modular telephone socket complete all as specified and as directed at site by the Engr-in-charge.
Item No 42 : Supply and fix TV socket, co-axial socket 1 module complete all as specified and as directed at site by the Engr-in-charge.
Item No 43 : Supply and fix rosette junction box complete all as specified and as directed at site by the Engr-in-charge.
PILE FOUNDATION
Item No 44 : Boring for bored cast in situ piles 600mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil to a distance not exceeding 50 M using DMC (Direct Mud Circulation) method complete all as specified and directed.
Item No 45 : Boring for bored cast in situ piles 450mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil to a distance not exceeding 50 M using DMC (Direct Mud Circulation) method complete all as specified and directed.
(a) Compression test
(b) Pull out test
(c) Lateral test
(a) Compression test
(b) Pull out test
(c) Lateral test
Item No 48 : Chipping out pile upto cut off level including initial load disposal upto a distance of 50M all as specified and directed.
(a) Compression test
(b) Pull out test
(c) Lateral test
(a) Compression test
(b) Pull out test
(c) Lateral test
Item No 50d Carrying out non- destructive interigity test of pile as per qualitative evulation of the physical dimension (cross sectional varation) soundness or defects of the piles concrete with respect to its continuity shall be carried out with IS 14893:2001for 600 MM dia pile.
Item No 50e Carrying out non- destructive interigity test of pile as per qualitative evulation of the physical dimension (cross sectional varation) soundness or defects of the piles concrete with respect to its continuity shall be carried out with IS 14893:2001for 450 MM dia pile.
SEWAGE DISPOSAL
Item No 51 : S&F 150 mm ID x 175 mm OD DWCPE (Double wall corrugated polyethylene pipe) as per IS 16098 P.2 :2013- SN4 complete all as directed. Make: ASTRAL
Item No 52 : S&F 200 mm ID x 225 mm OD DWCPE (Double wall corrugated polyethylene pipe) as per IS 16098 P.2 :2013- SN4 complete all as directed. Make: ASTRAL
Item No 53 : S&F SFRC Manhole cover complete all as directed.
HOT WATER APPLIANCES
Item No 54 : Supply, installing & Testing of Water heater(Geyser) storage type of capacity 25 liters, BEE 5 Star rated , 2KW capacity, glass lined coated inner tank, suitably installed with grouting of Nuts, Bolts and washers of suitable size, including 2 KW heating element, cable of suitable size as recommended by manufacturer, with 3 pin plug Top of suitable capacity, etc complete all as specified and as directed at site by the Engr-in-charge. Make: V-Guard Model No Steamer Plus EC or equivalent in the makes detailed in list of makes in Particular Specifications.
Item No 55 : S & F PVC connection for Cold/Hot Water 15mm with CP nuts and bolts and washers of length 300mm complete all as specifed and as directed at site.
AVIATION OBSTRUCTION LIGHT
Item No 56 : Supply and fix solid state electronic type aviation obstruction light fitting 300 Nos LED with cast aluminium poly carbonate red colour, with control switch and connecting & testing complete on top of Buildings all as directed. Make :-BAJAJ Model BGAV 302 LED or equivalent approved by GE.
EXTERNAL ELECTRIFICATION
Item No 58 : Supply, installation, commissioning and testing of Main LT Panel board 440 volts, 3 phase, 4 wire, 50 cycle per second, AC supply comprising of 600 Amps capacity Aluminium bus bar for the 3 phase and neutral, out door type of suitable size both side opening along with locking arrangement, rainguard canopy system, with ventilations, fabricated (panel body) out of steel sections i.e 3.00 mm thick CRCA sheet . The construction of panel shall be dust and vermin proof with phosphatised powder coated painting externally and internally to protect against corrosion. The panel shall be mounted on 4 nos supporting Legs of size 60 mm x60 mm and 6 mm thick and 60 cm long fixing with 1:2:4 PCC, Digital multi function meters with necessary CTs complete with cable duct ground clearance 45 cm from grouting bolts with following accessories complete all as specified and as directed :- Incoming : (i) MCCB, 4 Pole, 400 Amps,with Thermal release ,415 V, 35 KA -01 No Outgoing : (i) MCCB 4 Pole, 250 Amp,with Thermal release, 415 V , 36 KA -01 Nos (ii) MCCB 4 Pole, 125 Amp,with Thermal release, 415 V , 25 KA -03 Nos (iii) MCCB 4 Pole, 63 Amp,with Thermal release, 415 V, 25 KA -02 Nos ( for New Type-IV ) (iv) MCB TPN 16A-01(for servent qtr) (v) Indicator Lamp Set of 03 - 01 No Note :- LT Panel board shall be manufactured by a firm having its sample panel tested and certified by CPRI.
Item No 60 : Supply, installation, commissioning and testing of Essential Panel board 440 volts, 3 phase, 4 wire, 50 cycle per second, AC supply comprising of 300 Amps capacity Aluminium bus bar for the 3 phase and neutral, out door type of suitable size both side opening along with locking arrangement,rainguard canopy system, with ventillations, fabricated (i.e panel body made of) of 3.0 mm thick CRCA sheet . The panel shall be dust and vermin proof with phosphatised powder coated painting externally and internally to protect against corrosion. The panel shall be mounted on 4 nos supporting Legs of size 60mm x 60 mm and 6 mm thick and 60 cm long fixing with 1:2:4 PCC, Digital multifunction meters with necessaty CTs . Panel bottom to ground clearance shall not be less than 45 cm complete with following accessories complete all as specified and as directed :- a) LED/Neon indicator bulb in RYB Colour - 1 Set. b) Digital Voltmeter 0-500 volts, and Digital Ammeter 0-500 Amps of suitable size - 01 Set c) 4 No Bus bar 300 amps with chamber INCOMING :- a) MCCB 4 Pole, 63 Amp,with Thermal release,415 volt 16 KA -01 Nos OUTGOING a) MCCB 4 Pole, 40 Amp,with Thermal release,415 volt, 16 KA -01 No( for FPDG-1 panel) b) MCCB 4 Pole, 25 Amp,with Thermal release, 415 volt, 16 KA -01 Nos (for FPDG-2 panel) c) MCB TPN, 16 Amp,415 volt, 10 KA -01 No( for pump house) Note :- LT Panel board shall be manufactured by a firm having its sample panel tested and certified by CPRI.
Item No 61 : Supply, installation, commissioning and testing of Main LT Panel board 440 volts, 3 phase, 4 wire, 50 cycle per second, AC supply comprising of 200 Amps capacity Aluminium bus bar for the 3 phase and neutral, indoor type of suitable size both side opening along with locking arrangement, rainguard canopy system, with ventilations, fabricated (panel body) out of steel sections i.e 2.00 mm thick CRCA sheet . The construction of panel shall be dust and vermin proof with phosphatised powder coated painting externally and internally to protect against corrosion. The panel shall be mounted on 4 nos supporting Legs of size 60 mm x60 mm and 6 mm thick and 60 cm long fixing with 1:2:4 PCC, Digital multi function meters with necessary CTs complete with cable duct ground clearance 45 cm from grouting bolts with following accessories complete all as specified and as directed :- (FP1, FP2 for Type III & II) Incoming : (i) MCCB, 4 Pole, 125 Amps,with Thermal release ,415 V, 25 KA -01 No Outgoing : (i) MCB SPN, 20 Amp - 20 Nos (ii) Kwh Meter digital type 5-30A - 20 Nos (iii) Indicator Lamp Set of 03 - 01 No Note :- LT Panel board shall be manufactured by a firm having its sample panel tested and certified by CPRI.
Item No 62 : Supply, installation, commissioning and testing of Main LT Panel board 440 volts, 3 phase, 4 wire, 50 cycle per second, AC supply comprising of 200 Amps capacity Aluminium bus bar for the 3 phase and neutral, indoor type of suitable size both side opening along with locking arrangement, rainguard canopy system, with ventilations, fabricated (panel body) out of steel sections i.e 2.00 mm thick CRCA sheet . The construction of panel shall be dust and vermin proof with phosphatised powder coated painting externally and internally to protect against corrosion. The panel shall be mounted on 4 nos supporting Legs of size 60 mm x60 mm and 6 mm thick and 60 cm long fixing with 1:2:4 PCC, Digital multi function meters with necessary CTs complete with cable duct ground clearance 45 cm from grouting bolts with following accessories complete all as specified and as directed :- (FPDG1) Incoming : (i) MCCB, 4 Pole, 40 Amps,with Thermal release ,415 V, 10 KA -01 No Outgoing : (i) MCCB, 4 Pole, 25 Amps,with Thermal release ,415 V, 16 KA -03 No (for 03 Nos lifts) (ii) MCB SPN , 10 Amp, 230 volt -01 Nos ( for Type II and Type III common lights) (iii) MCB SPN, 10 Amp,-05 Nos (iv) Indicator Lamp Set of 03 - 01 No Note :- LT Panel board shall be manufactured by a firm having its sample panel tested and certified by CPRI.
Item No 63 : Supply, installation, commissioning and testing of Main LT Panel board 440 volts, 3 phase, 4 wire, 50 cycle per second, AC supply comprising of 200 Amps capacity Aluminium bus bar for the 3 phase and neutral, indoor type of suitable size both side opening along with locking arrangement, rainguard canopy system, with ventilations, fabricated (panel body) out of steel sections i.e 2.00 mm thick CRCA sheet . The construction of panel shall be dust and vermin proof with phosphatised powder coated painting externally and internally to protect against corrosion. The panel shall be mounted on 4 nos supporting Legs of size 60 mm x60 mm and 6 mm thick and 60 cm long fixing with 1:2:4 PCC, Digital multi function meters with necessary CTs complete with cable duct ground clearance 45 cm from grouting bolts with following accessories complete all as specified and as directed :- (FP3 for Type IV) Incoming : (i) MCCB, 4 Pole, 63 Amps,with microprocessor ,415 V, 25 KA -01 No Outgoing : (i) MCB TPN, 32 Amp - 04 Nos (ii) Kwh Meter digital type 5-60A - 04 Nos (iii) Indicator Lamp Set of 03 - 01 No Note :- LT Panel board shall be manufactured by a firm having its sample panel tested and certified by CPRI.
Item No 64 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 3.5 core, 185 sqmm cross-sectional area, complete all as specified and as directed.
Item No 65 : S&F 20 Watt LED building Security light fitting 230 V AC out door type die cast aluminium housing with heat resistant glass IP 65/66 environmental friendely, energy efficient not less than BEE 4- star rated with electronic driver including GI bracket made out of suitable dia GI pipe light grade 1.2 mtr. length bend to shape fixed to wall and connecting to ceiling rosewith three core flexible rose 1.5 Sqmm PVC copper conductor, complete all as specified and directed.
Item No 66 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 3.5 core, 120 sqmm cross-sectional area, complete all as specified and as directed.
Item No 67 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 3.5 core, 35 sqmm cross-sectional area, complete all as specified and as directed.
Item No 68 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 4 core, 25 sqmm cross-sectional area, complete all as specified and as directed.
Item No 69 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 4 core, 16 sqmm cross-sectional area, complete all as specified and as directed.
Item No 70 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 4 core, 10 sqmm cross-sectional area, complete all as specified and as directed.
Item No 71 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 2 core, 10 sqmm cross-sectional area, complete all as specified and as directed.
Item No 71A : S & F MCB TP, 32 Amp, 415 Volts, 10KA breaking capacity, "B" curve complete all as specified and as directed.
Item No 71B : S & F MCB DB, TPN, 4 way, 415 Volts, 50Hz, vertical type with bus bar neutral link blank plates etc. and provision for MCCB,s as incomer, complete all as specified and as directed. Note: Cost of copper lugs shall be included in the unit rate.
FIREFIGHTING
Item No 75 : Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor, cubical compartmental type "Motor Control Center" (MCC) of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete with all accessories all as specified and as directed. Make: Schneider, Siemens, L & T, ABB The "Motor Control Center" shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 500 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] 200 A, 415 V, Ics = 100% Icu =25 kA, 50 Hz FP MCCB, conforming to IEC 60947-2- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set
[vi] 32 A, 10 kA, 230 V, 50 Hz, SPN MCB- 01 Nos. [vii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 02 Nos. [iii] 32 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz FP MCCB, conforming to IEC 60947-2 01 Nos. [for jockey pump] [viii] LED phase indicators (Red, Yellow, Blue)- 02 Set NOTES: [i] The Panel shall be purchased from the original equipment manufacturer (OEM) only. [ii] The bidder shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, GADs, etc. for approval of the Engineer-in-Charge. [iii] Pump sets shall be installed as per IS 15301: 2003
Item No 76 : M & L for low smoke zero halogen (LS0H) fire survival control cable 2 core, 2.5 mm² (for instrumentation) with circuit integrity, conforming to BS 7846 and rated for 600 V, having plain annealed stranded copper conductor with fire-resistant mica tapes covered by an extruded layer of cross-linked polyethylene, extruded layer of thermoplastic low smoke zero halogen (LS0H) compound, single layer of galvanized steel wires and thermoplastic LS0H compound sheath, suitable for operating temperature range -40 ˚C to +90 ˚C and minimum bending radius being 12 times the overall cable diameter, including laying, clamping, termination and ferruling complete all as specified and as directed.
Item No 77 : M & L for low smoke zero halogen (LS0H) fire survival control cable 3 core, 2.5 mm² (for auto start/stop panel) with circuit integrity, conforming to BS 7846 and rated for 600 V, having plain annealed stranded copper conductor with fire-resistant mica tapes covered by an extruded layer of cross-linked polyethylene, extruded layer of thermoplastic low smoke zero halogen (LS0H) compound, single layer of galvanized steel wires and thermoplastic LS0H compound sheath, suitable for operating temperature range -40 ˚C to +90 ˚C and minimum bending radius being 12 times the overall cable diameter, including laying, clamping, termination and ferruling complete all as specified and as directed.
Item No 78 : M & L for low smoke zero halogen (LS0H) fire survival control cable 12 core, 2.5 mm² (for diesel engine pump) with circuit integrity, conforming to BS 7846 and rated for 600 V, having plain annealed stranded copper conductor with fire-resistant mica tapes covered by an extruded layer of cross-linked polyethylene, extruded layer of thermoplastic low smoke zero halogen (LS0H) compound, single layer of galvanized steel wires and thermoplastic LS0H compound sheath, suitable for operating temperature range -40 ˚C to +90 ˚C and minimum bending radius being 12 times the overall cable diameter, including laying, clamping, termination and ferruling complete all as specified and as directed.
Item No 79 : M & L for 1.1 kV grade copper conductor, XLPE insulated armoured cable 3 core, 35 mm² (for electric motor driven main fire pump) conforming to IS 7098-1: 1988, having stranded aluminium compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete all as specified and as directed.
Item No 80 : M & L for PN 1.6 rated 200 mm NB Cast iron foot valve for suction lift, conforming to IS 4038 with stainless wire mesh, bolts, nuts and washers, etc. Flange end connections, complete all as specified and as directed.
Item No 81 : Supply, installation, testing and commissioning of FM approved and UL listed microprocessor- based, true peer-to-peer networkable, Single Loop addressable Fire Alarm Control Panel (FCAP) with its own microcontroller memory, communication module, fire device loop interface cards for intelligent initiating and indicating devices and peer-to-peer networkable with other addressable fire alarm panels. conforming to UL 2572 mass notification systems & NFPA 72, with required accessories complete with all accessories all as specified and as directed. The FACP shall meet the following specifications / functional requirements. [i] The FACP shall have one to ten isolated intelligent Signalling Line Circuits (SLCs) capable of connecting up to 159 detectors and 159 modules per SLC or 318 devices per loop. [ii] The FACP shall have a degrade mode and the loops shall work in degrade mode in case of the CPU failure. [iii] The FACP shall have 640 character LCD backlit display/ Touch Screen display, full QWETRY program keypad, LED indicators viz. power; fire alarm; supervisory; system trouble; other event; signals silenced; point disabled; CPU failure; controls active; etc. membrane switch controls viz. acknowledge; signal silence; drill; system reset; lamp test; etc [iv] The FACP shall have four access levels, flash EPROM, 240 VAC power supply, automatic battery charger, 24 V sealed lead acid batteries, sufficient for 24 hrs normal working and 30 min in alarm condition. [v] The FACP shall have manual sensitivity adjustment up to nine levels, built-in alarm; trouble; security and supervisory relays, history file with 4000-event capacity in non-volatile memory plus separate 1000-event alarm-only file, keypad operation, LCD unit to indicate fire / fault signal of individual unit, in built printer to log all incoming data, etc.
[vi] The FACP shall have integrated 8 channel digital voice evacuation system controller capable of broadcasting evacuation messages on the same peer-to-peer network, fire fighter's telephone two-way communication system capable of supervising all the speaker circuits with adequate zone control and accessories etc. NOTES: [i] The FACP shall be servicable by any system integrator & shall not have dependency on specific system integrator. [ii] The FACP shall have feature to "ADD", "EDIT" & "DELETE" field devices like detectors & modules without dependency on PC / Software / Special tool / dongle. Make: Notifier NFS23030 + DVC or equivalent model of JC, Esser
Item No 82 : Supply, installation, testing and commissioning of UL listed (fire fighter's) addressable Telephone Jack mounted to a single-gang electrical back box with suitable interface module for two way communication with the Central Fire Fighter Telephone Console complete all as specified and as directed. Make: Notifier FPJ + FCM-1 or equivalent model of JC, Esser
Item No 83 : Supply, installation, testing and commissioning of UL listed Fire Fighter's Telephone Handset for two way communication with the Central Fire Fighter Telephone Console complete all as specified and as directed.
Item No 85 : M & L for low smoke zero halogen (LS0H) flame retardant fire alarm cable 2 core, 1.5 mm², conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and as directed.
Item No 86 : M & L for low smoke zero halogen (LS0H) flame retardant fire alarm cable 2 core, 2.5 mm² (supply to hooter / strobe), conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and as directed.
Item No 87 : M & L for PN 1.6 rated 100 mm NB Cast iron (CI) Sluice Valve, conforming to IS 14846: 2000 with cast iron body & bonnet, SS spindle & stem conforming to IS 6603: 2001, cast iron stuffing box, carbon steel stud / bolt / nut & washer, Hand wheel operated and flange end connection conforming to IS 1538: 1993 with necessary accessories complete all as specified and as directed.
Item No 88 :S & F of CL#150 rated two-piece design 25 mm NB Cast iron (CI) Straight pattern ball valve, conforming to IS 9890: 1981 and tested as per BS 6755-1, having Cast iron body, Stainless steel AISI 304 ball, renewable PTFE seat & gland packing, CS fastners & lever having screwed / socket weld end connection with accessories complete all as specified and as directed.
Item No 89 : S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and as directed. Make: Newage, AAAG, Minimax
Item No 90 : S & F of 3 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and as directed. Make: Kanex, Minimax, Aim-EX, Safeguard, coffco, Variex NOTES: [i] Operating pressure:10 to 15 bars [ii] Operating temperature : -30 Degree C to + 55 Degree C [iii] Performance criteria : Discharge time not less than 45 sec , throw not less than 4 meters [iv] Hydro test and burst pressure test : Shall pass hydro test pressure of 35 bars for 2.5 minutes and with stand a burst pressure of 55 bar
Item No 91 : S & F 4 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and as directed. Make: Kanex, Minimax, Aim-EX, Safeguard, coffco, Variex NOTES: [i] Operating temperature : -30 Degree C to + 55 Degree C [ii] Locking pin and wire seal should be provided to indicate that the extinguisher has not been use. [iii] Every Extinguisher should be supplied with an operating manual.
Item No 92 : S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and as directed. (In Parking Area). Make: Kanex, Minimax, Aim-EX, Safeguard, coffco, Variex
Item No 93 : S & F of 9 litre mechanical foam type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and as directed. (In Parking Area). Make: Kanex, Minimax, Aim-EX, Safeguard, coffco, Variex
Item No 94 : S & F of Signage having size 300 mm X 150 mm reading "EXIT" in 12.5 mm block letters in Green and white background, self illuminated properly spaced to provide good legibility located directly in corridor near to each staircase and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level.These lights shall emit the maximum light required even during the electricity supply or in Black out period with high energy efficiency manufactured using superior quality Aluminium Extrusion body raw material complete all as specified and as directed. Product Material: Aluminium ALLOY Extrusion Product Finish:- Matt Black / Snow white finish after phosphochromate treatment Wattage:- 5 Watt Mounting: Surface / Hanging Make: Variex, Mr safe, Matrix sign lab
Item No 95 : S & F of Signage having size of 500 mm X 500 mm, indicating the "Floor Number" in bold type and at 75 mm high numerals in red and white background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, posted and maintained within each stair enclosure on every floor, securely attached to the stair side of the door in a way that the bottom of the sign is not above 1.5 m from the finished floor level complete all as specified and as directed. Make: Variex, Mr safe, Matrix sign lab
Item No 96 : S & F of Signage having size of 450 MM X 150 MM reading "FIRE EXTINGUISHER" in 12.5 mm block letters in White and Red background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board,properly spaced to provide good legibility located directly in corridor near to each Manual call point/Fire Extinguisher and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level complete all as specified and as directed. Make: Variex, Mr safe, Matrix sign lab
Item No 97 : S & F of Signage having size of 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the "STAIRCASE" by an alphabetical letter in bold type and at 75 mm high letters in red and white background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board,securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level complete all as specified and as directed. Make: Variex, Mr safe, Matrix sign lab
DG SET
Item No 98 : Supply, installation, testing and commissioning of silent, Diesel engine driven factory assembled, floor mounted generating set alongwith retrofit emission console device as per CPCB norms, of capacity 62.5 KVA/50 KW at 0.8 power factor or nearest higher size, 3 phase, 4 wire, 50 Hz, 1500 RPM as per IS 10001/10002 to take 10% over load complete with safety control and metering equipments mounted on & including common base frame with acoustic enclosure (canopy), weather proof as per CPCB norms, powder coated all as per manufacturer's instructions manual and all as specified and comprising of the items/ accessories listed hereinafter:- (A) Prime Mover : Directly coupled diesel engine, water cooled suitably de-rated of matching BHP for driving 62.5 KVA capacity, alternator electric start, four stroke confirming to latest IS-10001/10002 for continuous running and capable for taking 10% over load for 01 hour complete with following accessories:- (i) Fly wheel to suit flexible coupling. (ii) Flexible coupling with guards. (iii) Air cleaner with filters. (iv) Lubricating oil filter (v) Heavy duty radiator assembly with fan. (vi) Anti-vibration pad as recommended by manufacturers. (vii) PT pump with electronic gevernor of suitable capacity. (viii) Self starter 12 volts DC. (ix) Necessary arrangement for charging battery. (x) Maintenance free battery 12 volts , duly charged -01 Nos, capacity as supplied by manufacturer and as recommended by manufacturer alongwith flexible copper battery lead and connector. Make :- EXIDE/ AMCO/STANDARD or as approved by GE.
(xi) Battery rack made out of MS angle iron 40 mm x 40 mm x 5 mm & 150 mm height - 01 No. (xii) Standard safety device. (xiii) Daily services fuel tank for full running capacity of DG set for min 12 hours enclosed within the canopy all as per CPCB with lever indicator inlet, fuel outlet drain plug, air vent and locking arrangements etc including fuel pipe connections with connected GI pipe medium grade from fuel tank to DG set and over flow from the DG set to fuel tank complete with gate valve. (xiv) Exhaust system shall be provided with retrofit emission control device as per CPCB norms shall be provided with thermal insulation by using fire retardant/ non igniting foam conforming to BS-4735 to prevent excess heat radiation on the engine and safety of operator. (xv) Mechanical panel having following accessories :- (aa) Digital Lubrication oil temperature guage - 01 No. (ab) Digital Lubrication oil pressure guage - 01 No. (ac) Digital Water temperature guage - 01 No. (ad) Starting switch with key - 01 No. (ae) Battery voltmeter. (af) Indicator lamp etc. (ag) Digital Ammetar DC-01 No. (ah) Digital RPM meter-01 No. (aj) Safety measures : (i) Low lubricant oil pressure trip. (ii) High coolant temp trip. (iii) Engine over speed trip. (iv) Battery charging alternator. (v) Emergency stop pressed.
(B) Alternator : 62.5 KVA at 0.8 power factor, self regulated 3 phase with neutral 415 volts 50 Hz 1500 RPM as per IS : 13364 complete with automatic voltage regulator and foot mounted including making cable connection. The salient feature of alternator are as under :- (i) Voltage regulation under static condition + 1.5%. (ii) Class 'F' insulation. (iii) Permanently lubricating bearing. (iv) Capable to take 10% over load for one hour for every 12 hours. (C) Control AMF Panel : AMF control panel inside the floor mounted acoustic enclosure. Suitable for 62.5 KVA DG set with by pass assessment including all necessary operating and control device (to meet the requirement of above capacity plus 25% over load) such as contactors, MCCBs, CT's, volts meter, Ammeter, indicating lamp, frequency meter, energy meter with protection fuses for panel instrument battery charging ststem with indicator and cut off relays low and high oil pressure, high speed over load and earth fault protection, reverse current protection duly wired copper conductor cable and cable connection with lugs/thimbles complete as recommended by manufacturers and as directed.
(D) Repair tools and 2 years maintenance spare parts as per following:- Repair Tools :- (i) Ring spanner set of 10-01 set. (ii) Screw driver 6”, 8”, 12”, 14” & 24”-02 each (iii) Spanner set of 01-01 set. (iv) Adjustable spanner 12” – 04 Nos. (v) Cutting pliers – 01 No. (vi) Techo meter- 01 No. (vii) Tools kit box (only box) – 01 N (viii) 2 Years Spare :- (a) Fan belt set complete - 01 No (b) Lub oil filter - 01 Set (c) Fuel filter - 01 Set (d) Service manual and spare part catalogue with guarantee card (e ) Shock treatment chart dully framed - 01 Set (f) First Aid Box - 01 set (g) Fire extinguisher foam - 01 set (h) Fire extinguisher (electricity ) - 01 set Make - Engine and Alternator :- Refer to PS.
(E) OEM MADE ACCOUSTIC ENCLOSURE :- Acoustic enclosure (canopy) suitable for 62.5 KVA DG with the following provisions/ specifications :- (i) The enclosure fabricated out of CRCA sheet of 14 SWG suitable to accommodate the DG Set properly. (ii) The sheet metal components are hot dip seven tank pretreated. (iii) It is pure polyester based powder coated (inside as wall as outside). All nuts/bolts/hardwares are zinc coated with salt spray test as per ASTMB- 117. (iv) Battery is accommodated in a tray in the enclosure. (v) The doors are fitted with gasket with high quality EPON gasket to avoid leakage of sound. (vi) Sound proofing of enclosure is done with high quality rock wool/mineral wool conforming to IS 8131 of 50 mm thickness and density of 96 kg/cum. (vii) The wool is further covered with fiber glass cloth and perforated powder coated sheet, insulation level conforming to UL 94 HF1 class flammability. (viii) A special residential silencer is provided within the enclosure to control exhaust noise. (ix) Specially designed alternators are provided to control sound at air entry to the container and exhaust from the container. (x) Adequate ventilation is provided to meet requirement for combustion and heat removal. If required a blower is used to meet total air requirement and air changes. (xi) Temperature of enclosure does not exceed beyond 50 degree C of ambient temperature. (xii) The enclosure is provided with “high enclosure temperature” safety device. (xiii) There should be provision of emergency shutdown from out side the enclosure. (xiv) There should be arrangement for proper illumination inside the canopy. (xv) Noise level should be 75 DB (A) at 1 mtr distance. (xvi) The accoustic enclosure should be as Approved by CPCB.
(F) CPCB NORMS :- DG Set should be as per CPCB-II norms emission limit (g/KWH) standards as follows:- (i) Oxides of Nitrogen + Hydrocarbon (NOx + HC < 4.7) (ii) Carbon Mono Oxide (CO < 3.5) . (iii) Particulate Matter (PM < 0.3) . (v) Smoke limit (Light Absorption Coefficient, per m ) < 0.7
Item No 99 : Design supply, install, testing and commissioning of 08 (544Kg) passengers , speed 1.5 metre/sec, with Machine Room, with single speed motor suitable for 415 Volts, 3 phase, 50 Hz AC supply operation, conforming to IS-14665, suitable to serve Ten upper floors (G+10) i.e. with 11 stops and 11 landings (Travel/rise 40 M approx) with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescuer device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Guard Room, machine room & near Ground floor landing door), complete all as specified and directed. Note :- 1) Contractor should keep the lift functional by repairing/replacing as decided by GE the components during the defects liability periods. 2) .Including all civil works required in connection with erection of lifts complete all as specified. The lift shall be provided with and including the following :- :- Make :- OTIS/MITSUBISHI/KONE/THYSSONKRUPP/JOHNSON
(A) TECHNICAL SPECIFICATION (a) Type & capacity : passenger elevator for 08 persons (544 Kg) (b) Type of drive : variable voltage and variable frequency drive with microprocessor based controller ± 5 mm landing accuracy with speed encoder. (c) Speed : 1.5 meter per second (d) Travel : Suitable for passenger travel of 40 meter (approx) (opening on same side). (e) Required well size : As per requirement. (f) Power supply : 415/440 volts, three phase 50Hz AC (should withstand variation of + 5% of Voltage) . (g) Inner size : 2000mm x 1100mm deep (Approx) (k) Car enclosure : Car size shall be in conformity with IS 3534-1976 , body to be stainless steel 16 gauge moonrock finish , SS false ceiling (hairline finish) with stainless steel hand rail 38mm hairline finish and mirror of 4mm thickness of suitable size. (l) Flooring : Polished granite flooring. (k) Electric light : LED light fitting (Minimum 04 Nos). (l) Fan : Pressure air fan 380 mm sweep – 01 No. (m) Car entrance : Automatic, centre opening, sliding doors (n) Clear opening : Not less than 800mm x 2000mm high. (o) Operation door : Automatic operation (p) Control : Simplex full collective with and without attendant. (q) Indicators : Hall position indicators for car & landing. Direction and position indicator with stainless steel fixtures at all floors.
(B) STANDARD FEATURES (i) Anti nuisance car call protection (ii) Automatic car return device (home landing) (iii) Specification plate with complete details (iv) Overloading Device. (v) Nudging (buzzer if door is held open for more than 30 Sec). (vi) Emergency fireman’s service (vii) Audible Car Call button (viii) Emergency Car light unit (ix) High performance contact free infrared curtain door protection (x) Door time protection (xi) Emergency alarm Buttom (xii) Extra door time of lobby & parking (xiii) Door open close button (xiv) Manual rescue operation (xv) Battery operated emergency light (LED ceiling fitting) alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeble arrangement for battery.
(xvi) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. (xvii) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. (xviii) Steel wire rope of adequate size as per relevant IS and as per manufacturer's specifications. (xix) Other standard fixtures and fittings like guide rails, sheaves, counter weights and guards, buffers, gear unit brakes control. (C) ADDITIONAL FEATURES (a) Automatic rescue device during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load.
(D) HUMAN INTERFACE DEVICE (HID) (i) Hall button with micro stroke push buttons combined with 16 – segment digital LED display position indicator. (ii) Full height car operating panel with micro stroke call push buttons (located on side panel) (iii) Door open/ door closed on car operating panel. (v) Monochrome LED digital position indicator display. (vi) Over load and floor announcement audio and visual arrangement. (vii) Fireman’s switch at main lobby (viii) Manual rescue operation (ix) Call register indicator in all landings (x) Attendent operation system in car panel
Item No 100 : Design supply, install, testing and commissioning of 13 (884Kg) passengers , speed 1.5 metre/sec, with Machine Room , with single speed motor suitable for 415 Volts, 3 phase, 50 Hz AC supply operation, conforming to IS-14665, suitable to serve Ten upper floors (G+10) i.e. with 11 stops and 11 landings (Travel/rise 40 M approx) with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescuer device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Guard Room, machine room & near Ground floor landing door), complete all as specified and directed. Note :- 1) Contractor should keep the lift functional by repairing/replacing as decided by GE the components during the defects liability periods. 2) .Including all civil works required in connection with erection of lifts complete all as specified. The lift shall be provided with and including the following :- :- Make :- OTIS/MITSUBISHI/KONE/THYSSONKRUPP/JOHNSON
(A) TECHNICAL SPECIFICATION (a) Type & capacity : passenger elevator for 13 persons (884 Kg) (b) Type of drive : variable voltage and variable frequency drive with microprocessor based controller ± 5 mm landing accuracy with speed encoder. (c) Speed : 1.5 meter per second (d) Travel : Suitable for passenger travel of 40 meter (approx) (opening on same side). (e) Required well size : As per requirement. (f) Power supply : 415/440 volts, three phase 50Hz AC (should withstand variation of + 5% of Voltage) . (g) Inner size : 2000mm x 1100mm deep (Approx) (k) Car enclosure : Car size shall be in conformity with IS 3534-1976 , body to be stainless steel 16 gauge moonrock finish , SS false ceiling (hairline finish) with stainless steel hand rail 38mm hairline finish and mirror of 4mm thickness of suitable size. (l) Flooring : Polished granite flooring. (k) Electric light : LED light fitting (Minimum 04 Nos). (l) Fan : Pressure air fan 380 mm sweep – 01 No. (m) Car entrance : Automatic, centre opening, sliding doors (n) Clear opening : Not less than 800mm x 2000mm high. (o) Operation door : Automatic operation (p) Control : Simplex full collective with and without attendant. (q) Indicators : Hall position indicators for car & landing. Direction and position indicator with stainless steel fixtures at all floors.
(B) STANDARD FEATURES (i) Anti nuisance car call protection (ii) Automatic car return device (home landing) (iii) Specification plate with complete details (iv) Overloading Device. (v) Nudging (buzzer if door is held open for more than 30 Sec). (vi) Emergency fireman’s service (vii) Audible Car Call button (viii) Emergency Car light unit (ix) High performance contact free infrared curtain door protection (x) Door time protection (xi) Emergency alarm Buttom (xii) Extra door time of lobby & parking (xiii) Door open close button (xiv) Manual rescue operation (xv) Battery operated emergency light (LED ceiling fitting) alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeble arrangement for battery.
(xvi) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. (xvii) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. (xviii) Steel wire rope of adequate size as per relevant IS and as per manufacturer's specifications. (xix) Other standard fixtures and fittings like guide rails, sheaves, counter weights and guards, buffers, gear unit brakes control. (C) ADDITIONAL FEATURES (a) Automatic rescue device during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load.
(D) HUMAN INTERFACE DEVICE (HID) (i) Hall button with micro stroke push buttons combined with 16 – segment digital LED display position indicator. (ii) Full height car operating panel with micro stroke call push buttons (located on side panel) (iii) Door open/ door closed on car operating panel. (v) Monochrome LED digital position indicator display. (vi) Over load and floor announcement audio and visual arrangement. (vii) Fireman’s switch at main lobby (viii) Manual rescue operation (ix) Call register indicator in all landings (x) Attendent operation system in car panel
EXTERNAL WATER SUPPLY
Item No 101 : Construction of Valve Chamber of size 900 X 900 X 900 mm internal size suitable for Sluice Valve, with PCC 1:3:6, Type C2, using 40mm graded aggregate for foundation, 75 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:4, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 5 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as directed.
Item No 102 : Construction of Valve Chamber of size 600 X 600 X 600 mm internal size suitable for Sluice Valve, with PCC 1:3:6, Type C2, using 40mm graded aggregate for foundation, 75 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:4, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 5 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as directed.
Item No 103 : Supply, installation, testing and commissioning of chemical dosing system, (calcium Hypo chloride, 60-70% chlorine content granules) alongwith injector with following specification alongwith complete accessories like lead tubing, connecting ferrules, check valves including followings:- 1. Preparation Tank Model No. VST-1005 of net capacity 170 litres of FRP dosing tank consisting of:- a) Water inlet line b) Over flow c) Outlet with Y-Strainer d) Drain e) Conical bottom for sludge deposition f) Pot hole with cover g) Level Gauge h) Agitator 120W, 900 RPM, 1Phase flangemounted motor with plastic shaft and impeller. 2. Service tank model No. VST-1006 of net capacity 100 litres of FRP dosing tank, consisting of:- a) Water inlet line b) Over flow c) Outlet with Y-Strainer d) Drain e) Level Gauge f) Agitator 120W, 900 RPM, 1Phase flangemounted motor with plastic shaft and impeller. g) Inspection Report h) Provisioning of mounting pump on lid/wall.
3. Dosing pump consisting of max pressure 5 Kg/cm square & Max flow rate 5 ltr/Hr. Make- M/S Rayalaseema (Varima Dosing Pump Model No VDP-0505.) or Equivalent approved Make as per E-In-C. complete all as directed.
Item No 104 : Supply install, testing and commissioning of horizontal type submersible pump set open well type, electric driven, AC 415 Volt, 3 Phase, 50Hz, S1 duty suitable for dischage min 250 LPM at 47 Mtr Head, complete inclusive of 40 mtr long submersiable suitable size flat copper cable and Soft Starter.(01 No Working/01 No Standby i.e. Total 02 Nos) complete all as directed. Make: KSB, Crompton and Kirloskar
Item No 105 : Cutting the any size/type of pipe line and inserting Tee and other specials as required for taking the 100mm tapping from the existing pipe line. complete all as directed.
Item No 106 : M & L for Construction of Valve pit of size 0.6 X 0.6 X 0.6 mtr internal dimentions with 23 CM brickwork in CM 1:6, 10 CM thick PCC (1 :3 :6 ) type C-2 in foundation, including plastering of all the exposed surface in CM 1:4 15 mm thick and upto 30 CM plastering of all unexposed surface of wall and 3 mm thick MS steel cover angle iron frame work 50X50X6 mm complete with locking arrangement including two coats of synthetic enamel paint over one coat of red oxide primer on steel surfaces including excavation and earth work and all as directed.
Item No 107 : M & L for 200 mm dia double wall corrugated pipe PVC (SN4) laid in trenches and jointed incl coupler with rubber rings complete all as directed. Make: ASTRAL or eqivalent
EARTHINGS
Item No 108 : Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 25x4mm GI earth Strip [Earth Lead] and GI pipe 32 mm bore, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and directed.
Item No 109 : Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and directed.
Item No 109A : Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 4 mm dia GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC pit with 1:2:4 type B1 concrete and RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and directed.
STP (SEWAGE TREATMENT PLANT)
Item No 110 : Design (hydraulically, structurally & aesthetically) engineering, procurement, construction, testing and commissioning of Sewage Treatment Plant based on Moving Bed Bio Reactor Technology (MBBR) with tertiary treatment having capacity of 100 KLD at karikal, as shown in the site plan. It comprises of Inlet chamber, fine bar screen chamber, oil and grease chamber, Air grid, Sewage pump, Air blower, equalization tank, anoxic chamber , anoxic pump, MBBR Tanks, Lamellar settling tank, sludge pump, Chlorine contact cum feeder tank, chlorine dosing system, feed pumps, multigrade filter, activated carbon filter, sludge drying beds, treated water tank, clear water pumps, cables, pipe, earthing, testing equipment ,foundation for all E/M equipment, pump house associated piping works with required valves, gates, drains, pathways , electrical control panels with interconnecting cables including spare parts required to keep STPs functional till defect liability period of 2 years of operation etc. complete as turnkey job including hydraulic testing with all involved civil, electrical, digital, mechanical works . The detailed specifications for civil, electrical & mechanical components are mentioned in Particular specification for guidance only. The scope of works shall also include Manning & Operation of STP for a period of two years up to Defect liability period .The cost for Manning & operation shall be quoted separately.The maintaince of the plant shall be the responsiblity of the contractor during defect liablity period (DLP) Make: ION EXCHANGE INDIA LTD. THERMAX LTD., M/S OPTIMUS ENVIIROPRO PVT LTD AND ALL OEM APPROVED BY E-IN C BRANCH. Notes1: - (a) Complete scheme shall be designed by the contractor based on Design parameters i.e. Raw sewage characteristics and treated sewage characteristics after tertiary treatment. The scheme shall be prepared by the contractor and vetted by IITs/NITs. /Govt. University for further approval from the accepting officer. The detailed design shall commence only after approval of the scheme. (b) The structural drawings shall be developed based on the final approved scheme duly vetted by IITs/NITs. The final approved scheme and drawings duly signed by the contractor’s authorized representative shall submit to the accepting officer for approval in six A1 hard copies and softcopy (CD).
(c) The items mentioned above are indicative only. Any items required over and above for completion and efficient functioning of the plant are deemed to be included in the rate quoted by the contractor. (d) The treated water shall be tested quartely up to DLPby the contractor from NABL accredited Lab and the test should conform to the parameters of treated water within limits as mentioned in Particular Specification. Nothing extra shall be payable for the same. (e) All the finalized drawings shall form part of the tender and all clauses for design of RCC structural elements mentioned in the tender shall be applicable thereto. (f) Preparation and submission of architectural drawings and structural drawing & design by using design software like STAAD/ETABS with load chart for entire structural components, viz, walls, columns, beams, slabs, staircases, tanks etc., along with structural drawings and complete design folder containing structural analysis and design calculations duly vetted by any IIT/NIT.
(g) For design purpose, expected life of building to be considered as minimum 50 years. The design shall be sound, economical and as per best engineering practices suitable for the region. Design shall be compliant of provisions of all relevant IS codes and statutory rules of Govt of India/concerned state Govt. (h) Design and detailing shall be as per requirements applicable to the karaikal area in respect of seismic forces as per IS code 1893, wind forces as per IS code 875 part 3, dead loads as per IS code 875 part 1, live loads as per IS code 875 part 2. (i) Structural design of foundation shall be based on a detailed soil investigation report to be supplied to the consultant (Appendix). The structural designer should analyse the soil investigation report completely and merely depending on the recommendation part. If any inconsistent data is found part of the soil investigation report, clarifications shall be obtained from GE (I) Chennai under intimation to E2 (Des) section of HQ CE (CG) Visakhapatnam. (j) Structural design of RCC structure shall be as per IS 456, IS 1893 & IS 13920 and detailing shall be as per IS 456, SP 34 and IS 13920. (k) For detailing and design ‘severe’ environmental exposure conditions and 2 hrs. fire rating shall be considered.(l) Contractor shall consider existing invert levels for design of STP in consultation with GE.
TESTING: Testing and commissioning of STP will include testing of all electro-mechanical equipments, treated effluent parameters for treatment of the sewage, etc starting from collection chamber to outlet of tertiary treatment plant. (i) The plant shall be run continuously for minimum 72 hours. Test will be carried out in the presence of GE and Engineer-in-Charge, Contractor/rep of contractor and Rep of OEM. Contractor shall deploy adequate technical staff to operate the plant continuously for 72 hours and he shall be liable to carry out all the maintenance / rectification required during this period . (ii) The contractor shall afford all facilities and make all necessary arrangements for these tests at his own cost. All arrangements including various instruments required to facilitate testing shall be arranged by contractor. (iii) If the test results are not acceptable, all repairs and replacement and extra work of removal and relaying or refixing shall be carried out by the contractor at his own expense and the STP plant will be retested, until test results indicate compliance with the prescribed requirement. (iv) The installation shall be taken over by MES after the plant has been successfully commissioned and tested . (v) Quarterly test report of the treated efflent will be submiited by the contractor during the period of DLP.TEST EQUIPMENT: The contractor will submit the following test eqipments (minimum) deemed to be included in the contract. pH Meter Digital- 01 Nos TDS Meter Digital Tester-01 Nos Chlorine Testing Kits-03 Nos (vi) any other equipments required for testing shall also be provided by the contractor, no extra cost will be paid on this regard. NOTES2:- (i) Defect liability period of Two year. (Repair / replacement/spares of various plant components, including labour for such work covered under performance Guarantee) (ii) The items given above are indicative only. Any items required over and above items, for complete and efficient functioning of the plant is deemed to be included in the rates quoted by the tenderer. (iv) Rates of Minor civil work for foundation of machinery etc deemed to be included in the work. (v) All works shall be carried out by skilled technicians of relevant trade under supervision of rep of OEM. (vi) The routing of cables/pipes/drains etc , shall have proper protection. The workmanship, finish, general appearance & layout of the plant shall be technically correct and aesthetic; all as directed by Engineer in Charge. (vii) Tenderer’s offered rate shall be deemed to include training and operation for 1 month after completion of the plant.
M & O FOR STP
Item No 111: Manning of Sewage Treatment Plant of 100 KLD - 1 No at Karaikal by providing one semi skilled operator for One Nos pump houses in two shifts per day during DLP period including operating of chlorine dosing system, operation of valves in each shift of 8 hours each including Sundays and Holidays by providing one operator per shift ,the shift timings are :- Ist shift ( 06:00 Hrs to 14:00 Hrs) IInd Shift (14:00 Hrs to 22:00 Hrs)
(a) During 1st year of DLP
(b) During 2nd year of DLP
Note for item 111: The scope of work includes : (i) Clearing of vegitation/bushes in and around the installations. (ii) Maintening of log sheets for operation and maintenance done. (iii) Periodically clearing of sludge drying bed.
Item No 112 : Supply only of sodium hypochloride solution (During 2 years maintaince period).
BALAJI MATRIX HOLDINGS
G R M CONSTRUCTIONS
SHAIJAL T M
CREATIVE BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid