Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹7.8 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹8.1 LRejected-Finance CHANDIGARH | ₹8.1 L | L2 | Rejected-Finance L2 |
| 3 | L3₹12.0 LRejected-Finance NOT AVAILABLE | ₹12.0 L | L3 | Rejected-Finance L3 |
Tender Value
₹15.8 L
EMD Value
₹31,510
Closing Date
27 Feb 2026, 12:00 pmClosed
Er. Gurpreet Singh Bhains
Office of the Executive Engineer, Electrical Division No. 1, Sector-9,Chandigarh.
RENOVATION OF WORK IN SDO (BUILDING) BRANCH, ESTATE OFFICE SECTOR-17, CHANDIGARH. (IBM SCHEME NO. W2/2025/24883).
2026_CHD_90785_1
E1/TN-584
Open Tender
Electrical Works
60 days
Chandigarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹31,510
17 Mar 2026
20 Feb 2026
27 Feb 2026
20 Feb 2026
27 Feb 2026
20 Feb 2026
DSR Item No. 1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required.
Group C.
DSR Item No. 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Group-C
DSR Item No.1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
DSR Item No. 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
DSR item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
3 Pin 5/6 A. socket outlet
Telephone socket outlet
DSR item No.1.27 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75 mmX75 mm)
6 Module (200 mmX75 mm)
8 Module (125 mmX125 mm)
12 Module (200 mmX150 mm)
DSR item No.1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
DSR item No.1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
DSR item No.1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
DSR Item No. 1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
DSR item No.1.57 Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
DSR Item No. 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections Ics=100% Icu and Operational Voltage 690V etc. as required.
100 A,36KA,FPMCCB
200 A,36KA,FPMCCB
630 A,50KA,FPMCCB
DSR Item No. 8.6 LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, (As per Complete Item No. 14 of the DNIT)
DSR ITEM NO. LED 8.9.5 Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, (As per Complete Item No. 15 of the DNIT).
DSR ITEM NO. 9.2 Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, (As per Complete Item No. 16 of the DNIT)
1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Supply and fixing of 12 modules (200 mm x 150 mm) G.I box suitable for accommodate the following accessories along with modular base and cover plate for modular switches in recess / surface etc as required for Computer Point with 4 Nos. 5/6 Amp. modular switch and 4 Nos. 3 pin 5/6 Amp.(As per Complete Item No. 17 of the DNIT)
Supply & fixing of Computer jack & contact one module RJ45 of Molex/ R&M/ Panduit make including making connection etc. as required to complete the job to the entire satisfaction of Engineer-in-charge.
Supply and fixing extra down rod of 15 mm dia G.I. pipe length to fix the ceiling fan. The job includes cost of cutting, making holes and cutting groove in pipe for proper tightening of rod to the fan motor. The pipe should be B-Class of Jindal / Hindustan/ Tata make only. The job including installation testing, commissioning of ceiling fan including making connection with existing wire.
LT PANEL: Supply, erection testing and commissioning of L.T. Cubical panel outdoor type double door with canopy, degree of protection IP–65 as per IS 8623/93 cold rolled sheet steel 1.6mm thick for frame work, enclosure & doors, (As per Complete Item No. 20 of the DNIT)
Size of LT Panel 1850mm x 2000mm of suitable depth.
LT PANEL: Supply, erection testing and commissioning of L.T. Cubical panel outdoor type double door with canopy, degree of protection IP–65 as per IS 8623/93 cold rolled sheet steel 1.6mm thick for frame work, enclosure & doors, 3mm thick for gland plates with stiffeners fabricated and MS,(As per Complete Item No. 21 of the DNIT)
Size of LT Panel 1250mm x 1350mm of suitable depth.
Providing and fixing MCB TPN 63 AMPS, 415 volt ‘C’ curve 10 KA breaking capacity in the existing enclosure as per site requirement. The job includes making connection with suitable size with copper wire to the entire satisfaction of engineer in charge. Make should be
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.06 MB
BOQ_111024.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid