The Executive Engineer Civil Tender KTK Circle
Executive Engineer (Civil) Tender, O/o Sr. CE(Civil), BSNL, KTK Circle, Room No 324, 3rd Floor, O/o CGMT, Doorasamparka Bhavan, No 1, Swamy Vivekananda Road, Bengaluru 560008
Periodical maintnce and allied civil works at D8/5, arresting leakages in garage and master bed room and miscellaneous civil works at MSEA-1, Reconstruction of collapsed compound wall at E-9 at WMS comp arresting leakages Q-1 Sqtrs at TE building Bgl
2024_BSNL_218750_1
58/EEC/BSNL/CD/BGL/2024-2025
Open Tender
Civil Works - Buildings
Item Rate
60 days
Bengaluru
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
The Accounts Officer (Cash) HQ BSNL BGTD BENGALURU
₹8,559
Yes
27 Dec 2024
10 Dec 2024
24 Dec 2024
12 Dec 2024
21 Dec 2024
12 Dec 2024
12 Dec 2024 - 20 Dec 2024
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing :
1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form work for :
Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc..
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.
Brick work with common burnt clay modular bricks of class designation 5.0 in foundation and plinth in:
Cement Mortar 1:6 (1 cement : 6 coarse sand).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level with :
Cement mortar 1:6 (1 cement : 6 coarse sand).
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level with :
Cement mortar 1:6 (1 cement : 6 coarse sand).
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :
Kiln seasoned and chemically treated hollock wood.
Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets :
20 mm dia (heavy type)
25 mm dia (heavy type)
Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378)
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with available M.S. Flat and nuts & bolts complete.
Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete.
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kgper sqm including pointing the joints with white cement mixed with pigment of matching shade complete.
12 mm cement plaster of mix :
1:6 (1 cement: 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix :
1:6 (1 cement: 6 fine sand)
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete :
old work (two or more coats)
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade.
Old work (one or more coats)
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
One or more coats on old work.
Finishing walls with Acrylic Smooth exterior paint of required shade :
Old work (One or more coat applied @ 0.90 ltr/10 sqm).
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge.
With cement mortar 1:4 (1 cement : 4 fine sand).
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm).
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge.
Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer in-charge
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge..
In cement mortar
Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :
In cement mortar
Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
For thickness of tiles 10 mm to 25 mm
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Flexible pipe
32 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
20 mm nominal outer dia. Pipes.
25 mm nominal dia Pipes
Making connection of CPVC distribution branch with G.I. main of following sizes by providing and fixing tee, threading the pipe including cutting and fixing with CPVC solvent cement etc. complete :
25 to 40 mm nominal bore
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
100 mm diameter
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
15 mm nominal bore.
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
15 mm nominal bore with 45 cm length.
Cutting holes up to 30x30 cm in walls including making good the same:
With common burnt clay F.P.S. (non modular) bricks.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.
(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and filling light weight cinder in sunken portions etc. complete as per directions of E-I-C (Nominal size 20mm)
P/F SWR grade fittings of approved make and manufacture
110 mm dia bend
75MM DIA BENDS
110MM DIA BENDS with access door
75MM DIA BENDS with acess door
P/F PVC SWR grade pipes of approved brand and manufacture including fixing it in position using solvent or cement mortar ,all complete as directed by Engineer-in-Charge
75mm dia
110mm dia
P/F PVC MULTI FLOOR TRAPS of approved brand and manufacture; 110mmx75 mm including breaking open and removing the damaged floor trap and making good the same with white cement all complete as directed by Engineer-in-Charge.
Providing and fixing stainless steel grating with or without hole for waste pipe for covering existing floor/nahani trap.
(a)100mm dia
Providing and fixing C.P. brass bib cock /stop cock of approved quality conforming to Is standards .Cost includes removal of non-funtional/worn-outbibcock/stop cock etc complete as directed by the Engineer in charge.
Providing and fixing 15 mm Health faucet of C.P brass head and P.V.C connection pipe of approved make etc. complete as per the directions of Engineer-in-Charge. Cost includes removal of non-funtional/worn-out health faucet.
Providing and fixing C.P brass two in one tap including fittings of approved make etc. complete as per the directions of Engineer-in-Charge.Cost includes removal of non-funtional/worn-out Two -in- one tap.
Removing and refixing of wash basin for maintenance and repair works including brackets, screws etc. complete as per the direction of Engineer-in-charge.
Removing and refixing the PVC door shutter after removing the dmaged hinges and fixinf with new butt hinges etc complete as directed by the Engieer in charge.( Note: The cost of butt hinges shall be paid separately)
Providing and laying Ceramic matfinish floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick CementMortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cementand matching pigment etc., complete. as directed by the Engineer in charge.
Providing necessary repairs to the damaged MS windows/doors by removing the door shutter (either by cutting/ burning the hinges using gas welding machine at site or by removing the shutter after removing the screws and butt hinges as the case may be) and refixing the door in original position after removing the bend/ undulations in the door (members either horizontal or vertical or replacing the member it self (if required) including making good the damaged portion with necessary enamel painting (two or more coats over a coat of steel primer) all complete as per the directions of Engineer in charge.
MS Garage DOOR Shutters (Note: The approximate door area to be repaired shall be 6sqm )
Providing and fixing frameless edge polished glazed side hung cubboard shutter of approved brand and manufacture with glass knob and Chromium plated brass pivot hinges , including making necessary holes etc., for fixing required fittings, all complete as per direction of Engineer-in-charge .With5 mm thick plain glass with edging.
Providing and fixing flexible/washable nylon mosquito mesh of approved make saint gobain or equivalent with necessary velcro and fixing to the existing frame with necessary adhesive all complete as directed by Engineer-in-Charge
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, of dia 10mm with open /close arrangement including fixing with necessary screws etc. complete. As directed by the engineer in charge.
Providing anfd fixing MS plate of 1mm thick bleow shaft opening of area up to 1.5 sqm with necessary screws, necessary welding ,grinding of edges and making good the damaged portions etc complete as directed by the Engineer in charge.(Note: The rate to include the cost of all labour material and related incidental work Nothing extra shall be paid on any account).
Repairs to the leaking SWR fttings such as bend, door bend of all dia including removing fixing in restricted shaft areas etc cmplete as directed by the Engineer in charge. (Note : cost of fitting shall be paid separately)
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Credit to the department by the Contractor for taking (a)dismantled damaged / defective C.P Brass/Brass/Gunmetal fittings such as ,Bib cocks , stop cocks, angle cocks, gate valves , ball cocks , waste couplings , towel rail , towel ring, Shower rose and other items identified by Engineer-in-charge.
Credit to the department by the Contractor for taking dismantled, damaged PTMT tamps etc., of similar items.
Cutting tree roots encountered in trench of girth from 10cm to 30 cm using carpenters saw, power cutter saw and axe wherever required complete as directed and disposal of debris to a lead of 50m.
Refixing the available grill in the brick work of area up to 5sqm including fixing the lugs embedded in cement concrete 1:2:4( 1cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size) etc complete as directed by the Engineer in charge.
Refixing the avaialble steel gate of area upto 5sqm in the available hold fast in original position after removing the bend/ undulations in the gate (members either horizontal or vertical or replacing the member it self (if required) etc complete as directed by the Engineer in charge.
P/F SWR grade fittings of approved make and manufacture
110 MM DIA PLAIN BEND
75MM DIA PLAIN BEND
110MM DIA BENDS with access door
75MM DIA BENDS with acess door
110MM DIA" T"with access door
75MM DIA "T" with acess door
110mm dia coupler
75mm dia coupler
Providing and fixing 15mm C.P Brass pillar taps of approved quality conforming to IS. Standard of approved make etc. complete as per the directions of Engineer-in-Charge. Cost includes removal of non-funtional/worn-out pillar tap
P/F 2mm thick GI slotted wall bracket for fixing of PVC pipes in shaft
200x50mm bracket
P/F GI saddle (U-clamp) with nuts and washers of matching size for fixing of PVC pipes over wall brackets
110mmx8mm
80mmx8mm
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .