Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.4 LAccepted-AOC GURUDWARA LANE PORT BLAIR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹47.2 L+₹1.8 L (3.86%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹47.9 L+₹2.5 L (5.55%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹48.9 L+₹3.4 L (7.57%)Rejected-Finance CHOTHRAPUR BRICHGUNJ POST PORT BLAIR SOUTH ANDAMAN 744 103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹49.4 L+₹3.9 L (8.68%)Rejected-Finance OPP CCS GARACHARMA PORT BLAIR 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹35.6 L
EMD Value
₹71,500
Closing Date
23 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BRICHGUNJ
GE BRICHGUNJ
ADDITION/ALTERATION TO WATCH TOWER AT SEA VIEW ENCLAVE AND CERTAIN PROVISION WORK BRICHGUNJ MILITARY STATION PORT BLAIR
2024_MES_639923_1
8429A
Open Tender
Civil Works
Item Rate
180 days
GE BRICHGUNJ
As per NIT
9 documents required · 9 mandatory
₹500
GE Brichgunj
₹71,500
Yes
2 Apr 2024
31 Jan 2024
26 Feb 2024
31 Jan 2024
23 Feb 2024
18 Feb 2024
Amount
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
Demolition of Precast Concrete Block work built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, approns and laid bedded and pointed in any mortar etc complete all as specified and directed.
Dismantling Plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings in roof covering complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed.
Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed.
Use & waste of Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick, for fair finished flat surfaces of concrete complete all as specified and directed.
M&L for RCC- M -30 Design Mix as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
S&F Mild steel TMT bars 6 to 8mm dia as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F Steel work in tubular/structural trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 or steel sections conforming to Fe 410-W (Gde E-250) quality -A complete all as specified and directed.
M&L for Plates (Plain or Chequered) channels, square or notched (Ordinary and counter sunk) forming holes, without any attachment of Fe 290 (Gde E-165) completely all as specified and as directed by Engineer in Charge.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc and fixed by riveting or welding or with nut and bolts (including nuts and bolts) conforming to Fe-410-W grade E 251 Quality B complete all as specified and directed.
S&F Mild steel bolts exc 12mm dia and n exc 20mm dia purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long complete all as specified and directed.
Mild steel screw bolts, diameter of neck in 16 to 20mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10cm and n exc 15cm long
S &F MS work in wind ties for roof including securing bolts complete all as specified and directed.
M&L Painting to new steel and iron surfaces of exc. 10cm wide or girth by two coats of synthetic enamel paints over a coat of red oxide primer including preparation complete all as specified and directed.
Surfaces of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet, 0.5mm thickness, of colour as approved by GE, having tensile strength of 550 Mpa as in roof coverings/cladding to wall, etc, fixed with & including self tapping screws on angle frame complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet, 0.5mm thickness, of colour as approved by GE, having tensile strength of 550 Mpa as in roof coverings/cladding to wall, etc, fixed with & including self tapping screws on angle frame complete all as specified and directed.
S&F Plain, Aluminium sheeting 0.56mm thick, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) complete all as specified and directed.
M&L Precast Cement Concrete Block Masonry with Solid Block, exc 10cm in width in type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) complete all as specified and directed.
Taking down cement plaster of any description on brick or concrete surfaces etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar 1: 6 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L Rendering 5mm thick in CM 1:3 on soffits of RCC slabs, roof projections, soffits and sides of RCC beams, waist slab, Loft Slab, RCC shelves, Chajjas, and the like finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in two coats on faces of brick work or concrete surfaces; first coat (rendering coat) of 10 mm thick in cement mortar 1: 6 and second coat (finishing coat) of 5 mm thick in cement mortar 1: 4 mixed with water proofing compound (water proofing compound to be measured separately as supply only) and finished even and smooth complete all as specified and directed.
Supply only integral WPC
M & L for preparing newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of putty complete all as specified and as directed.
M & L for preparing newly plastered ceiling surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of putty complete all as specified and as directed.
M & L for complete removal of existing treatment on old plastered wall surfaces and applying two coats of oil bound distemper over a coat of resistant primer over a coat of putty complete all as specified and as directed.
M& L for Finishing walls with Acrylic smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) etc complete all as specified and as directed. (Make Apex Ultima)
M & L for complete removal of existing treatment on old plastered surfaces of walls and applying Two or more coatsof 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over a coat of putty complete all as specified and directed.
M&L Light shade Vitrified ceramic tiles 10mm thick (Square/rectangular) area of each tile exc 0.42 Sqm but n exc 1.00 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
M&L Light shade Vitrified ceramic tiles 10mm thick (Square/rectangular) area of each tile exc 0.42 Sqm but n exc 1.00 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match but in skirting/dado laid over 10mm thick cement plaster in cement mortar 1:4 except screed bed complete all as specified and as directed.
M&L 100mm thk cement concrete type D2 1:4:8(Using 40mm graded stone aggregate) in sub base of flooring/hard standing complete all as specified and as directed.
M&L 40mm thk cement concrete type B-1 1:2:4(Using 20mm graded stone aggregate) in sub base of flooring/hard standing complete all as specified and as directed.
M & L for coloured chequered cement concrete tiles 30 cm x 30cm x 25 mm thick, set and jointed neat cement slurry and pointed with With mixture of white & grey cement in equal proportions & no pigment, over and including 20 mm thick screed bed or bedding layer in CM 1:6 etc. complete all as specified and directed.
M&L Machine cut pre polished kota stone slab flooring 20-25mm thick over 20mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
All as per itemn No. 39 above except screed bed but in skirting/dado laid over 15mm thick cement plaster in cement mortar 1:4 complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) soil, waste and vent pipe, in any length , with rubber joints, laid in trenches or in floors complete all as specified and directed.
S&F in repairs 75mm bore PVC (SWR) soil, waste and vent pipe, in any length , with rubber joints, laid in trenches or in floors complete all as specified and directed.
S&F 110mm bore PVC (SWR) soil, waste and vent pipe, in any length , with rubber joints, fixed in walls complete all as specified and directed.
S&F PVC (SWR) 110mm dia bend of any radius complete all as specified and directed.
S&F PVC (SWR) 75mm dia bend of any radius complete all as specified and directed.
S&F PVC (SWR) 110mm dia double T equal or unequal at Junctions of any radius complete all as specified and directed.
S&F PVC (SWR) 75mm dia double T equal or unequal at Junctions of any radius complete all as specified and directed.
Dismantling boarding/Frame work of any description, fixed in any position with nails/screws complete all as specified and directed.
S & F Aluminium anodised (minimum anodisation is 50 microns) Door / window / Ventilator/partition frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars,standard aluminium grills, with panel inserts of sheet glass, gauze including necessary joining cleats, glazing clips, rubberbeading, Neoprene packing, anodised aluminium snap beading, screws, imax hinges,butt hinges,handles, locking arrangements etc., complete with standard aluminium sections, complete all as specified and as directed (Aluminium section shall be of make Jindal/Hindalco/ Indalco). (Note:- Weight of various Aluminium sections handles and locking arrangements shall only be considered for measurement for payment. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted. Glass panels, prelaminated particle boards, aluminium wire cloth as applicable will be measured and paid separately).
Supply only 12mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination and fixed to aluminium frames complete all as specified and as directed.
Supply only 4.0mm thick sheet glass, ordinary quality in squares exc 0.50 sq.m in each pane complete all as specified and directed.
Supply only 150mm aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
Supply only 250mm aluminium alloy anodised sliding bolts with hasp, staple and fixing clips of sheet, cast or extruded section fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and directed.
Supply only Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed.
Supply only 125mm aluminium handles, cast type , anodised complete all as specified and directed.
Material and labour for false ceiling with aluminum grid work (Size of grid 600x600 mm) with 35 x 25 x 1.5 mm main tee and 25 x 25 x 1.4 mm cross tee and wall angle and suspended with 2mm dia GI wire hooked to roof with needful adjustment bolts at an interval of 1.20 m centre to centre staggered and board with Eco board decorative type size 600 x 600 x 4 mm thick finished with two coats of oil bound distemper over a coat of primer on exposed surfaces complete all as specified and directed.
Supply and fix in repair ECO board 600x600x4mm thick decorative type fixed in existing aluminium grid frame work for false ceiling incl two coats of oil bound distemper over a coat of primer complete all as specified and directed.
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
M&L for Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling complete all as specified and directed.
M & L for RCC- M -30 Design Mix as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed
Use & waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for fair finished surfaces of concrete complete all as specified and directed.
S&F Mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
All as per item no 64.00 here in before but for 6 to 8mm dia as in stirups
M&L for hard core of broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in 100mm thick as in sub base complete all as specified and directed
M & L Chequered cement concrete tiles, with grey cement and pigment 30cm x30cm x20mm thick set, jointed and pointed in neat cement slurrry in floors including 15mm thick screed bed in Cm 1:4 complete all as specified and directed
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete toFe-410- W(Gde?E-250) quality?B
Excavation in post holes (or similar holes) each not exceeding 0.5 cum getting out in Hard/dense soil returning filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25cm watering and removing surplus soil to a distance not exceeding 50m and making good surfaces complete all as specified and as directed.
M&L for PCC 1:3:6 type C2(using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed.
Taking down carefully, copper/aluminium point wiring (Light, fan, scoket or power) complete, including fittings and fixtures such as switches, ceiling roses, sockets etc., and making good disturbed surfaces of walls floors, etc., complete all as specified and as directed.
M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover/Pre moulded PVC switch board for housing the switches, socket outlets, fan regulators etc., all as specified and as directed for the following: - One light point controlled by one way switch
One ceiling fan point controlled by one way switch
One 3 pin switch socket outlet point 5 amps on same board with other switches.
One 3 pin switch socket outlet point 5 amps on independent board.
All as per item at sl No 73.00 here in before but with copper conductor cable for one 3 pin socket outlet, 15 amps independent, with cable 4 Sqmm size and 4 Sqmm earth continuty conductor, complete all as specified and as directed.
Supply and fix of switch piano flush type single pole one way 5 Amp complete all as specified and directed
Supply and fix switch socket combination 2 in 1, 3 pin (mult pin) 5 amps flush type, complete all as specified and directed
Supply and fix switch socket combination outlet, 2 in 1, 3 pin 15 and 5 amps, controlled by one switch flush/box type complete all as specified and directed
Supply and fix fan speed regulator, electronic suitable for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and directed
Supply and fix ceiling rose surface baklite 65 x 50 mm 3 terminal, complete all as specified and directed
Supply and fix energy efficient LED Smart bright batten 22 watt fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core shethed cable from fitting to ceiling rose complete all as specified and directed
S&F 36W New genration energy saving & envoirmental friendly long life versatile pressure dia cast aluminium IP65 road way luminaire with high power LEDs as light and electronic driver complete with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete all as specified and directed
Supply and fix in repair metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB, complete all as as specified and as directed.
All as per item at sl No.85 here in before but SPN, 4 way 240 volts complete all as specified and as directed.
Supply and fix MCB single pole, 240 volts, 5 to 32 Amps, complete all as specified and as directed.
Supply and fix MCB SPN 240 volts, 5 to 32 Amps, complete all as specified and as directed.
Taking down old unserviceable ceiling fan 1200 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades and transporting to workshop to undertake repairs by rewinding of burnt out winding using suitable gauge copper wire, replalcement of worn out capacitor 2.5 mfd - 01 No., PVC canopy - 02 No's and bearing including scrapping of old paint and applying two coats of synthetic enamelled white paint over a coat of red oxide primer complete and refixing back at site complete all as specified and as directed.
Taking down old unserviceable exhaust fan 300 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades and transporting to workshop to undertake repairs for rewinding of burnt out winding using suitable gauge copper wire, replalcement of worn out capacitor 4.0 mfd - 01 No and bearing including scrapping of old paint and applying two coats of synthetic enamelled grey paint over a coat of red oxide primer complete and refixing back at site complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F Bldg Security light 25W LED energy saving & envoirmental friendly long life versatile pressure dia cast aluminium IP65 road way luminaire with high power LEDs as light and electronic driver complete with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete all as specified and as directed.
Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor.complete all as as specified and as directed.
Supply and fix metal enclosure distribution board TPN 4 way 415 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, complete all as as specified and as directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN 16 to 32 Amps and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
Supply & Lay XLPE insulated, heavy duty 1100 volt grade electric armoured LT UG cable with aluminium conductor of size 25 Sqmm 3.5 Core in trenches/along the wall/including making all connections, saddles,complete wih aluminium lugs as required at site complete all as specified and as directed.
Supply & lay cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm OD and ID 38mm confirming to IS 14930 -II and ISI Marked complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for getting out for laying of pipelines /cables in hard/ dense soil complete all as specified and directed.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation over area, exceeding 1.5m but not exceeding 3m deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed. at a level not exceeding 1.5m above the starting point complete all as specified and directed.
S&F MCCB, 4 pole, 100 Amps with breaking capcity 25KA , 415Vs, including provision of one MCCB enclosure 4 pole with lugs/thimbles of suitable size in existing panels complete all as specified and directed.
Supply and fix 25 mm bore GI tubing medium grade laid in trenches / floor or fixed to wall in any length with screwed and socket joints together with all galvanised GI fitting such as sockets, bends, elbows, tees, reducers, unions, jointing materials etc and pressure testing, washing out complete all as specified and directed
Supply and fix 25 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed, complete all as specified and as directed
M&L for cutting existing 40mm GI line and making branch connection of 25 mm dia GI line including fittings required for connection complete all as specified and directed
Supply and fix 25 mm bore Gun Metal gate valve with iron wheel head ISI Marked screwed both ends suitable for GI tubing complete all as specifed and directed
Supplying, hoisting and fixing rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of 1000 Litre capacity etc complete all as specified and directed.
Supply, lay, test and commissioning under ground XLPE insulated and PVC sheathed, armoured heavy duty under ground cable, suitable for earthed system, laying in trenches/duct sleeving through pipe in duct, ISI marked with aluminium stranded conductor 1100 volt grade of cross section area 4 Core 16q mm complete all as specified and as directed.
S&F tube light grade galvanised with all fittings laid in trenches of following size.(a) 50 mm bore.
Material and Labour for cutting bituminous road at a width not more than 30cm and a depth not exceeding 60 cm for laying of pipes on road crossing for cable protection and making good with cement concrete 1:2:4, type, B-2 to match the existing surfaces of the road all as specified and as directed.
Excavation in trenches, exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.0m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed.
M&L Loose filling with aggregate of Broken stones or boulders of gauge 15 to 80 mm in soakage pits, soakage wells complete all as specified and directed. Note: Filling materials shall be of size 75,50,40,25 & 15 mm layers at the Ratio 5:4:3:2:1 laid from bottom to top for the portion 'H' and Top 700 mm shall be filled with 15mm material.
M&L Double layer of bamboo matting tarred on both sides and fixing to frames or supports with munj or other approved string complete all as specified and directed.
Spreading and levelling in layers of average 150mm thick using excavated earth well ramming including watering and consolidation over matting complete all as specified and directed.
ANITA VARMA ENTERPRISES
Nirman Construction Company
MAJUMDAR FURNITURE
DEEPAK AGENCIES
P Babu
Bismi Builders & Enterprises
M/s Kamal Electrical
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .