Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹36.2 L+₹2.4 L (6.99%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹38.0 L+₹4.1 L (12.1%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹42.9 L+₹9.1 L (26.8%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹43.6 L+₹9.8 L (28.9%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
₹45.9 L
EMD Value
₹91,750
Closing Date
15 Nov 2023, 6:00 pmClosed
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
PROVN OF CERTAIN SPECIAL REPAIR WORKS IN THE AREA OF AGE B/R I UNDER GE (NORTH) AHMEDNAGAR
2023_MES_623775_1
8792 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer North Ahmednagar
Class D Cat a(i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer(North) Ahmednagar
₹91,750
Yes
1 Jan 2024
18 Oct 2023
17 Nov 2023
18 Oct 2023
15 Nov 2023
1 Nov 2023
Amount
Taking down cement plaster on brick or concrete surfaces on wall/ceilling/stone/block etc including racking out joint, hacking for key,scrubbing down with water etc all as specified and as directed
Demolition of brick work or stone/ boulder masonry/PCC block, built in cement mortar or cement lime mortar including all quoins, pillars etc.
M&L for PCC 1:4:8 type -D2 using 40 mm graded aggregate in fdn filling and mass concrete.
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6
M & for Plain Cement Concrete Type B0 1:2:4 (using 12.5 mm graded granite stone aggregate) in copings, kneelers, including weathering, slightly rounded or chamfered angles and throating, as directed
Material and labour for special treatment ot sunken portion with 10mm thick plaster in CM 1:4 with WPC liquid complast 421 and applying one coat Each of Nittoproof 120 on plastered surface rendering again 10mm thick in CM 1:4 mixed with complast - 421 filling the sunken floor with PCC 1:5:10 using brick bat area of floor upto 1.5 Sqm including 40 mm dia 0.60 m pipe etc complete all as specified and directed by Engineer-in-Charge. Note : Work has to be carried out strictly by the authonticated applicator of the manufacturer and as per manufacturers specification as approved by GE.
M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 , finished even and smooth without using extra cement
M&L for rendering 15 mm thick in CM 1:6 over brick surfaces, finished even and smooth without using extra cement all as specified and as directed.
M&L for rendering 10 mm thick in CM 1:3 on ceillng, finished even and smooth all as specified and as directed.
M&L 10 mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4 with finished even and fair with out using extra cement with and including water proofing compound @3% by weight of cement all as specified and directed .NOTE- Supply only integal water proofing compounnd shall be measured and paid separately
M&L for rendering 15 mm thick in CM 1:4 over brick or concrete surfaces, finished even and smooth using water proofing compound @ 3% by weight of cement in toilet/bath prtion floor Note: WPC shall be measured and paid separately.
M & L applying two coats of OBD over a coat of primer on newly plastered wall surfaces iover 2 coat of wall care putty preparation of surfaces all as specified and as directed.
M&L for preparing newly plastered surfaces of ceilings and applying three coats of white wash.
M&L for preparing new plastered surfaces and applying Two coats of cement base paint over a coat of alkali resistant primer on surfaces of walls.
Supply only integral water proofing compound
M&L for preparing old surfaces of walls by brooming down or by steel wire brushing and applying one coat of white wash including scafolding at any height complete all as specified and directed by Enggineer-in-charge.
M&L for preparing old surfaces of ceilings by brooming down or by steel wire brushing and applying one coat of white washincluding scafolding at any height complete all as specified and directed by Enggineer-in-charge.
Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint including scafolding at any height complete all as specified and directed by Enggineer-in-charge..
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) including scafolding at any height complete all as specified and directed by Enggineer-in-charge..
M&L for complete removal of existing treatment and prepartion of surfaces including filling the cracks if any on surfaces of walls and applying two coat of acrylic distemper over a coat of primer over 2 coat of wall care putty including scafolding at any height complete all as specified and directed by Enggineer-in-charge.
M&L for prepartion of newl plastred surafce and applying of two coat of exterior emulsion paint colour as approved as GE, using ultra clean paint or Dulax ICI or Apex Ultima of Asian Paints or equivalent in Berger Paints over the old decorated wall surfaces, edges of slab, roof/chajja projection ana column etc., after necessary preparation all as specified and as directed.
M&L for application of one coat of exterior emulsion paint colour as approved as GE, using ultra clean paint or Dulax ICI or Apex Ultima of Asian Paints or equivalent in Berger Paints over the old decorated wall surfaces, edges of slab, roof/chajja projection ana column etc., after necessary preparation all as specified and as directed.
M&L for preparing old painted surfaces by washing, rubbing down and stopping of painted surfaces and applying a coat of cement base paint on surfaces of walls including scafolding at any height complete all as specified and directed by Enggineer-in-charge.
Material and labour for 75 mm thick plain cement concrete 1:4:8 type D2, using 40 mm graded stone aggregate as in sub base all as directed.
Providing and laying rubber moulded glossy finish 60 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete
Taking down of chowkat with shutters without taking off shutters from the frame ,exceeding 1.5sqm but not exeeding 2 sqm each all as specified and as directed.
Taking down of chowkat with shutters without taking off shutters from the frame not exceeding 1.5sqm each all as specified and as directed.
Taking down of shutters of any description exceeding 1 sqm each and not exceeding 2 sqm each all as specified and as directed.
S&F IInd class hard wood plain solid, straight ,chowkats and frame, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints all as specified and as directed.
S&F 30mm thick flush door shutter soild core construction with block board core and plywood face panels commercial type on both sides .
S&F second class hardwood glazed and skeleton shutters 35mm thick open rebated and prepared to receive glass gauge etc with sash bar divided into squares edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass or gauze etc sizes of members of shutters as specified inSSR part-I section 8 clause 8.20 (a) fitted to chowkats .
S&F steel ventilators with centre hung shutters including two pairs of brass cup pivots, catch spring and pulling wheel complete including taking down old one all as specified and as directed.
S&F in repairs mild steel handle to existing steel windows left or right (as per existing pattern) all as specified and as directed.
S&F in repairs mild steel peg stay for windows/ ventilators all as specified and as directed.
M/L for welding in repairs n exc 2.5cm in length n exc 6mm thick all as specified .
M&L welding in repairs to broken hinges of doors and windows to metal frame all as specified and as directed.
M&L for preparing new surfaces of wood of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of pink primer all as specified and as directed.
Ditto all as per item No 37 above but on steel surfaces over red oxide primer
S&F 300 mm long, mild steel ordinary rat rail springs including roller and roller plate complete and facing down old one all as specified and as directed.
S&F butt hinge, medium weight ,cold rolled mild steel 100mm long all as specified and as directed.
Aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extruded sections or cast aluminium alloy 300 mm long and fixed all as specified and as directed.
Floor door stopper of aluminium alloy body double and tongue annodised with rubber shoe and fixed of size 150 mm all as specified and as directed.
Aluminium anodised barrel tower bolt of extruded section 200 mm long and fixed all as specified and as directed.
S&F extruded aluminium alloy handle fabricated type anodised 150 mm long
Aluminium framed windows any pattern, fixed/side hung/silding ( three track) using powder coated alluminium sections, of approved make with or with out sash bars suitable for 4mm thick glazing including necessary jointed cleats, glazing all as specified Note-: (glazing shall be measured and paid separatly)
Hacking out old broken glasses any thickness, size, quality or description from wooden frames glazed with putty or fixed with bead all as specified and as directed.
S&F sheet glass ordinary quality 3 mm thick with oil putty exceeding 0.5 sqm in each pane all as specified and as directed.
S&F sheet glass ordinary quality 4.8 mm thick with oil putty exceeding 0.5 sqm in each pane all as specified and as directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples all as specified and as directed.
S & F in repairs Harrison rails,anodised aluminium alloy with fixing brackets, stops, rollers etc
Demolition of Cement concrete (unreinforced) in any description and in any position not otherwise specifically provided forand pavings n exc 15 cm thickness (below or above ground level) including floor finishes
Demolition floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and removal of debries to a distance not exceeding 100m all as specified and as directed.
S/F double charged Virified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, of size 800x800, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar 1:6 .
S/F double charged vitrified ceramic tiles 8 to 10mm thick (square/rectangular) polished, area of each tiles exceeding 0.18 sqm but not exceeding 0.36sqm,in vertical surfaces such as skitings, dado set and jointed in neat cement slurry and pointed in white or coloured cement to match including rendering 10 mm thick in CM 1:4 on fair faces of brick or concrete surfaces of wall as in backing of skirting and dado all as specified and as directed.
S&F Non-skid Coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) size of each tiles 400x400 mm in floors etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar 1:6
M&L for Glazed ceramic coloured tiles in vertical surface 350*250*7 /450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match in backing of skirting and dado including rendering 10 mm thick in CM 1:4 on fair faces of brick or concrete surfaces of wall as in backing of skirting and dado all as specified and as directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc
M&L for Mirror polishing on marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish complete.
Material and labour for machine cut kota stone flooring 18-20 mm thick over Screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc as directed by Er-In-Charge.
Material and labour for machine cut kota stone flooring 20-25 mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and making 2 nos of 3mm thick grooves on edge of treads of staircase etc as directed by Er-In-Charge.
Material and labour for machine cut kota stone slab 20-25 mm thick in riser of steps,skirting,dado and pillar laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 10mm thick backing coat in cement
Material and labour for rough dressed shahabad stone, 25 mm to 40 mm thick laid over and including 15 mm thick screed bed in cement and sand mortar (1:6), laid and jointed and pointed in cement and sand mortar (1:3) etc complete all as specified and directed by Engineer-in-Charge.
M&L providing PCC 1:3:6 type C2 (using 40mm graded stone aggregate) 75mm thick finishing cement concrete surfaces even and fair without using extra cement as in plinth protection , path etc
M & L for PVC (SWR) multi floor trap of 75mm outlet with grating including jointing with solvent cement except trap
S & F PVC (SWR) Floor trap of 75 mm outlet plain with grating including jointing with solvent cement.
S & F 75 mm bore PVC (SWR) Vent Cowl
All as per item no above but 100 mm bore
M&L PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement all as specified.
S&F 75mm PVC (SWR) pipes single socketed in any length with rubber fing joints fixed to walls all as specified.
S&F 75mm PVC (SWR) pipes single socket in any length with rubber ring joints in trenches or in floors all as specified.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.
S & F 110 mm bore PVC (SWR) branch piece double (Double `Y') equal or unequal with access door.
S & F in repairs 15 mm bore Fancy type Chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S & F in repairs Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand.
S&F in repair Chromium plated shower roses 125 mm dia size with or without swevel joints and size including fixing to steel pipe or union.
S & F in repairs Fancy type chromium plated with long shank and cup (Concealed type) 15 mm bore Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
S & F in repairs 10 litres PVC valve less, Syphonic action type, Flushing cistern low level, white with inlet ball valve float chain and pull and brackets complete.
S&F in repair 15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed.
S/F for vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe)
S&F Towel rail 60cm long with lower hangers of CP with and including chromium plated brass screws and wooden /plastic cleats .
S&F 15mm dia Chromium plated fancy type Bib taps cast copper alloy with crutch or butterfly handles screwed down screwed for iron pipe fixed in repair all as spd & directed
S&F for 20 mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule all as specified and directed.
S&F for 25 mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule all as specified and directed.
Grubbing up plant including roofs and applying antiweed chemical in concrete surface and making good with PCC including necessary required scaffolding etc . Upto G+1 building all as specified and directed . Note: PCC will be measured and separately.
M & L for repairs to ends of chajja by removing the old loose concrete material, cleaing the reinforcement and fishing the surface apply epoxy base resin of manufacturer Pidcrete and Chowkasi and make good with concrete 1:1.5:3 as required to exiting broken surafce and fair and even in cement mortar 1:3 with epoxy coating and applying two coats of wether proof emulsion paint upto 600 mm depth and 100 mm thickness including nessasary scofolding as required at site Upto G+1 building all as specified and directed
Taking up/down steel tubing 15 mm bore and connection including cleaning/removal to store Complete all as specified and directed.
Taking up/down steel tubing 20 mm bore and connection including cleaning/removal to store Complete all as specified and directed.
Taking up/down steel tubing 25 mm bore and connection including cleaning/removal to store Complete all as specified and directed.
S&F GI water tubes of bore 15 mm dia tubes medium grade with all fittings and fixed complete to walls and ceilling or laid in floors all as specified and directed.
S&F GI water tubes of bore 20 mm dia tubes medium grade with all fittings and fixed complete to walls and ceilling or laid in floors all as specified and directed.
S&F GI water tubes of bore 25 mm dia tubes medium grade with all fittings and fixed complete to walls and ceilling or laid in floors all as specified and directed.
S&F 20 mm outer dia 3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings or in floors etc.
S&F 25 mm outer dia 3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings or in floors etc.
M&l for GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste
M&l for cutting of existing cracks on wall up to 10 mm deep and n exc 10 mm face and clean the groove properly and fill crack with filler materials with gunating machine up to last edge of crack in two coat and apply tow coat of wall care putty and 2 coat of oil bound distemper.
Taking down carefully existing unserviceable bitumen felt(any number of layers) including plaster of any thickness, wire brushing and cleaning of the surface of roof terraces including flashing and junctions of parapets kerb wall, PCC fillets, benching etc and removing of the rubbish to a distance not exceeding 500 m from the building and depositing where complete all as specified and directed
Demolition of plain cement concrete (unreinforced) in ground floor including concrete at junctions of parapets and roof terraces, flashing kerbs walls, PCC fillets, benching coving of chajjah top/junctions etc complete all as specified
Material and labour for providing plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) for roof, kerb, or mud stops, rounded or chamfered on edges etc complete all as specified and as directed.
M&L for rendering 10mm thick CM (1:4) on roof slab top mixed with water proofing liquid finished even and fair without using extra cement complete all as specified
M&L for cleaning the newly plastered surfaces of concrete (roof etc) with wire brushes and applying water proofing treatment as under :- (i) Applying one coat of oil bound bituminous primer @ 0.25 kg/Sq. M (ii) Providing and laying 3mm thick APP modified water proofing membrane weighing not less than 3.5 Kg/Sqm reinforced with non woven polyester mat weighing not less than 160 gm/Sqm all as specified procured from any one of the approved manufactures (iii) Apply one coat of solar reflective bituminous aluminium paint @ 0.15 kg/Sqm over membrane over non assesble roof surfaces complete all as per manufactures instructions and as directed
Disconnecting existing PVC water tanks of capacity exc 500 litres & n. exc 1000 litres setting aside (or lowering) for repair work and hoisting , reconnecting, refining in the same position complete all as specified and as directed.
Fabrication and fixing only existing Rolled Mild Steel Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe 410 - W (Gde E-250)quality-A,
Fixing only existing Pre-painted galvalume aluminium zinc coating GI based manglore pattern corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall,fixed with self tapping screwsaas specified etc all as directed.
M&L for preparing old surfaces of steel of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
M&L applying evenly a tack coat of leakge/seepage proof polymer chemical of Dr fixt/chaukasi/asian at the rate of 1.2 kg per sq.m including cleaning/drying the surfaces in wet portion of floor brfore plastering in item no 06 above. Note : Work has to be carried out strictly by the authonticated applicator of the manufacturer and as per manufacturers specification as approved by GE.
Excavation in trenches n.exc 1.5M wide and N.exc 1.5M in depth for foundation etc or for manholes n.exc 10 Sqm on plan and n.exc 1.5m indepth and getting out in soft/loose soil all as specified and directed by engineer-in-charge
Excavation in tr enches n.exc 1.5M wide and N.exc 3.0 M in depth for foundation etc or for manholes n.exc 10 Sqm on plan and n.exc 1.5m indepth and getting out in hard/dense soil all as specified and directed by engineer-in-charge
Demolition of cement concrete (unreinforced) blocks/bricks/RR walling built in cement mortar including coping etc of any description etc complete all as specified.
Demolition of cement concrete (unreinforced) of any description,in any position,from the foundation of manhole including benching etc complete all as specified.
Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for.
Demolition and breaking up drain pipes 150 mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar
All as per item above but 200 mm bore pipe
Returning,filling in including spreading levelling,watering and well ramming in layers n.exc 25cm complete as directed
Removing excavated soil n.exc 50mand depositing where directed at a level n.exc 1.5M above the starting point
M&L for 150 mm bore Reinforced cement concrete pipe,type NP-2,haunching against the sides of pipe in PCC 1:4:8 type D-2 using 40 mm graded machenically crushed stone aggregate and making necessary connection after cutting into existing sewer line/manhole to make it functional complete all as specified as following. Note: (i) Cutting into existing sewer line/manhole shall be measured and paid seperately. (ii) Excvation & earthwork shall be measured & paid seperately.
M&L for 200 mm bore Reinforced cement concrete pipe,type NP-2,haunching against the sides of pipe in PCC 1:4:8 type D-2 using 40 mm graded machenically crushed stone aggregate and making necessary connection after cutting into existing sewer line/manhole to make it functional complete all as specified .
M&L for 300 mm bore Reinforced cement concrete pipe,type NP-2,haunching against the sides of pipe in PCC 1:4:8 type D-2 using 40 mm graded machenically crushed stone aggregate and making necessary connection after cutting into existing sewer line/manhole to make it functional complete all as specified .
M&L for reinforced cement concrete 1:2:4 type B-1 using 20 mm graded mechanically crushed stone aggregate as cover slabs for drain and manhole including necessary formwork and making holes 25 mm dia@150 mm centre to centre ,set and jointed in cement morat 1:6 complete all as specified and as directed.
M &L for Plain Cement Concrete Type B0 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregate as in cills,stpes,bands ,coping,bed plates,kerbs,hold fasts block etc i including weathering, slightly rounded or chamfered angles and throating including formwork complete all as specified.
M &L for Plain Cement Concrete Type B0 1:3:6 type C-2 using 20 mm graded mechanically crushed stone aggregate as in surface chanel & drain etc complete all as specified.
Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips
Cutting in to existing manholes for connecting new drains 200/300 mm internal dia of making good to pipe and rendering cutting out existing benching for and foRming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and refoRming benching as required
Cutting in to existing manholes for connecting new drains 150 mm internal dia of making good to pipe and rendering cutting out existing benching for and foRming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and refoRming benching as required
Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Chage
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC boxes and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as Earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. Note : 1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etcMake of FRLSH Cable.Havells/Polycab/Finolex
One light point/fan point controlled by switch 5 Amp single pole one way
One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch
One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board
All as per Item No 126 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase, Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board Make of FRLSH Cable.
S&F switch piano flush type single pole, one way 5/6 Amp etc complete all as specified and directed by Engineer-in-Charge .
S&F Socket, 6 Amp,3 Pin 230V AC etc complete all as specified and directed by Engineer-in-Charge.
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required etc complete all as specified and directed by Engineer-in-Charge.
S & F Socket outlet 2 in 1 3 pin, 6/16 Amp, flush type
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directed by Engineer-in-Charge
M&L ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge .
S & F in replacement double door Sheet metal enclosures factory made DBs SPN, 8 way ,240 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed.
Supply & fixing MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing MCBs, SPN, AC, 240 volts of 40 Amps capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge .
S&F in replacement energy saving and environmental friendly long life LED street light 25 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge.
S & F in replacement double door Sheet metal enclosures factory made DBs 4 way TPN, 415 volts ,protection class IP-42, suitable for fixing of MCBs etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed.
Supply & fixing MCBs, TPN, AC, 415 volts of 63 Amps capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
S&F sub main wiring with two single core PVC insulated,unsheathed, FRLSH stranded copper conductor cable 4 Sqmm with 4 Sqmm PVC insulated, unsheathed, FRLSH stranded copper conductor cable as earth wire drawn through and including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note : 1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. Two run of 4 Sqmm cable i.e for one run for phase, one run for neutral with one run of 4 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit.
M & L for Supply,laying ,connecting ,testing and commissioning and jointing , LT underground cable in replacement ,1100 volts grade, XLPE insulated, armored with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in ducts, fixed on poles/walls with proper size saddles and clamp complete all as specified and as directed by the Engineer-in-Charge of following Sizes :- (a) LT cable 25 Sqmm, 3.5 core.
Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 m in depth and getting out in hard/dense soil etc complete all as specified and directed by Engineer-in-Charge
Returnig, filling in including spreading, levelling, watering and well ramming in layers, n exc 25 cm thick in soil etc complete all as specified and directed by Engineer-in-Charge
Removing exacavated soil to a distance n. exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point etc complete all as specified and directed by Engineer-in-Charge
Supply &lay HDPE pipe 50 mm bore for laying of LT cable complete with all accessores etc complete all as specified and directed by Engineer-in-Charge
Material and labour for submain wiring in PVC Conduit Pipe FRLS PVC insulated copper conductor wire of size 2x1.5 sqmm+1x1.5 sqmm earth wire complete all as specified and directed by Engineer-in-charge
Material and labour for submain wiring in PVC Conduit Pipe FRLS PVC insulated 3 Corec copper conductor wire of size 2x2.5 sqmm+1x2.5 sqmm earth wire complete all as specified and directed by Engineer-in-Charge
Supply and fixing open well submersible pump of 2 HP,single phase,230V,50 Hz complete all as specified and directed by Engineer-in-Charge
M & L for Supply,laying ,connecting ,testing and commissioning and jointing , LT underground cable in replacement ,1100 volts grade, XLPE insulated, armored with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in ducts, fixed on poles/walls with proper size saddles and clamp complete all as specified and as directed by the Engineer-in-Charge of following Sizes :- (a) LT cable 10 Sqmm, 4 core.
Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 m in depth and getting out in hard/dense soil etc complete all as specified and directed by Engineer-in-Charge
Returnig, filling in including spreading, levelling, watering and well ramming in layers, n exc 25 cm thick in soil etc complete all as specified and directed by Engineer-in-Charge
Removing exacavated soil to a distance n. exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point etc complete all as specified and directed by Engineer-in-Charge
Supply &lay HDPE pipe 50 mm bore for laying of LT cable complete with all accessores etc complete all as specified and directed by Engineer-in-Charge
M&L Factory made Outdoor type Panel, made out of 16SWG CRCA Sheet, Powder coated, Weather Proof,Front Opening Shutter with proper Locking Arrangement,suitable for Totally Enclosed complete and grouting in cement concrete 1:2:4(20 mm graded stone aggregate) work of suitable size including necessary Electric connection and Testing,Comprising with the following including Taking down unserviceable Panel,complete all as specified and as directed: (a)Copper Bus-bar 4 strip,450mm long,100 Amps,415 Volt- 01 Set (b) Incoming TPN 63 Amps,16 KA-01 (c) Outgoing MCB SPN ,10KA-04 (d) Digital Voltmeter-01,Digital Ammeter with CT-01 (e) S&F DOL Starter for 2HP open well submersible pump
S&F Insulating electrical rubber mats of size(1 Mtr x 2 Mtrs) and thickness 8 mm complete all as specified and directed by Engineer-in-Charge.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts & washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm CIC, both way, lifting arrangement complete including all necessary earth work etc complete all as specified and directed by Engineer-in-Charge
M/S. M. F. Sharif & Co.
M/s AG PATHAN
MATOSHREE CONSTRUCTION
MS. G.A. CONSTRUCTION
M/s. N D Karande
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .