| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest tender | |
| 2 | L2₹22.0 L+₹2.0 L (10.1%)Rejected-Finance | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹22.0 L+₹2.1 L (10.4%)Rejected-Finance | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹22.6 L+₹2.7 L (13.5%)Rejected-Finance | L4 | Rejected-Finance Not being lowest tender | |
| 5 | L5₹23.2 L+₹3.3 L (16.4%)Rejected-Finance 197 C P COLONY MORAR GWALIOR GWALIOR MADHYA PRADESH 474006 | GWALIOR | MADHYA PRADESH | 474006 | L5 | Rejected-Finance Not being lowest tender |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
10 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TA
GE AF TA GWALIOR-474020
REPAIR/MAINT OF AMF PANEL AND CONNECTED MISC WORKS IN TECH AREA/SINGPUR AT AF STN GWALIOR
2021_MES_496184_1
8900/1371/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF TA GWALIOR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF TA GWALIOR
₹40,000
Yes
11 Feb 2022
20 Dec 2021
18 Jan 2022
20 Dec 2021
10 Jan 2022
3 Jan 2022
60 days
Amount
Dismantling, taking down and removing the old existing un serviceable non-functional / broken hinges of any description and in any position of existing feeder pillar boxes/panel boards etc and supply and fixing new cold rolled medium weight mild steel hinges in position as per existing requirement with necessary spot welding, screwing etc including making necessary adjustment for free and smooth movement of panel and locking arrangements complete all as specified and directed.
S & F following items in AMF Panel of any description and in any position of capacity DG Set upto 500 KVA including checking AC/DC circuits, tightening of all power / control wiring connection and replacement of unserviceable control wiring with suitable size, single core, copper conductor, flexible, PVC insulated, unsheathed cable suitable upto 1100 volts trade confirming to IS-694, taking out, removing and replacement of unserviceable parts / spares / items to make AMF functional inclusing testing complete all as specified and directed.
Pla relay 24 Volts DC, 11pin, 2 change over, cat part No. 2C/O – MPC -24D of pla make or equivalent of Eagle man.
Pla relay 12 Volts DC, 11pin, 2 change over, cat part No. 2C/O – MPC -12D of pla make or equivalent of Eagle man.
Ammeter size 96 mm X 96mm, flush mounted digital type, three phase of class 1.0 complete all as specified and directed.
Voltmeter size 96 mm X 96mm, flush mounted digital type, three phase, class 1.0 complete all as specified and directed.
Frequency meter size 96 mm X 96mm, flush mounted digital type, three phase, class 0.2 complete all as specified and directed.
Under voltage relay suitable for 3 phase 415 volts, AC supply complete all as specified and directed.
Engine starting relay with sequence timer & master timer suitable for 12 / 24 Volts DC supply complete all as specified and directed.
Electronic timer, time range from 3 seconds to 10 seconds , suitable of 12/ 24 Volts, 50 Hz, AC supply complete all as specified and directed. Make : L&T / PIC / Aditya Electronic.
Rectifier 4 plates, single phase, having charging rate 15–20 Amp per minute for 12/24 Volts DC battery charge complete all as specified and directed. Make : Usha / URI / Kirloskar.
Rectifier 8 plates, single phase, having charging rate 15–20 Amp per minute for 12/24 Volts DC battery charge complete all as specified and directed. Make : Usha / URI / Kirloskar.
LED Indicator 22.5mm for 12 /24 volts AC/DC supply complete all as specified and directed. Make: L&T/ BCH / Seimens / ABB.
Battery charging transformer 0 to 10 Amperes ,12 Volts DC tapping 0-12 -18-24 Volts complete all as specified and directed .
MCB single pole, 10 KA, rating 6 to 32 Amps ‘C’ series, 240 volts complete all as specified and directed.
S&F in repair including testing of Power contactor , of following capacity, for 415 Volt AC supply complete all as specified and directed :-
Power contactor 3 pole, AC3 rating of 630 Amps, with 1NO + 1NC auxiliary contacts
Power contactor 3 pole, AC3 rating of 580 Amps, with 1NO + 1NC auxiliary contacts
Power contactor 3 pole, AC3 rating of 500/550 Amps, with 1NO + 1NC auxiliary contacts
Power contactor 3 pole, AC3 rating of 400 Amps, with 1NO + 1NC auxiliary contacts
Power contactor 3 pole, AC3 rating of 325 Amps, with 2 NO + 2 NC auxiliary contacts Make : L&T MNX 325 or equivalent in make as approved by GE.
Power contactor 3 pole, AC3 rating of 210 Amps, with 1NO + 1NC auxiliary contacts
Power contactor 3 pole, AC3 rating of 200/225 Amps, with 1NO + 1NC auxiliary contacts
Power contactor 3 pole, AC3 rating of 185 Amps, with 1NO + 1NC auxiliary contacts
Power contactor 3 pole, AC3 rating of 110/125 Amps, with 1NO + 1NC auxiliary contacts
Power contactor 3 pole, AC3 rating of 110 Amps, with 2 NO + 2 NC auxiliary contacts Make : L&T: Model No MNX 110 or equivalent in make as approved by GE.
Dismantling of alternator assembly of DG Set of capacity 200 KVA to 400 KVA and taking out U/S Exitation winding and rewinding of excatation coil with supper enamell insulated copper winding wire varnishing & heating up complete all as per specified and directed.
M&L for repairing of canopy of DG set by carrying out repairing of door with replacement of broken hinges including nuts, bolts/welding etc as per requirement, cleaning of base of foundation and painting with black paint MS channel with two coats including touching of paint at cannopy where required complete all as specified and directed for DG set capacity ranging from 160 KVA to 500 KVA.
S&F in repair lead acid battery DC 12 Volts, 150 AH complete all as specified and directed. Make - Exide/Amaron or make as approved by GE
S&F in repair lead acid battery DC 12 Volts, 180 AH complete all as specified and directed. Make - Exide/Amaron or make as approved by GE
S&F in repair including testing of MCCB, of following capacity, having adjustable thermal magnetic release for 415 Volt AC supply complete all as specified and directed :-
(a) MCCB, 4 pole, 100 Amps, breaking capacity Icu = 25 KA.
(b) MCCB 3 pole, 125 Amps, breaking capacity Icu = 25 KA.
(c) MCCB, 4 pole, 160 Amps, breaking capacity Icu = 25 KA.
(d) MCCB, 4 pole, 200 Amps, breaking capacity Icu = 25 KA
(e) MCCB, 4 pole, 250 Amp, breaking capacity Icu = 35 KA
(f) MCCB, 4 pole, 315/320 Amp, breaking capacity Icu = 36 KA
(g) MCCB, 4 pole, 400 Amps, breaking capacity Icu =36 KA
(h) MCCB, 4 pole, 630 Amps, breaking capacity Icu = 50 KA
S&F in repair including testing of ON LOAD change over switch of following capacity for 415 volts conforming to IS : 13947( Part I & III ) complete all as specified and directed :-
(a) ON LOAD change over switch, 4 pole, 630 Amps, in open execution/Panel mounting, front operated.
(b) ON LOAD change over switch, 4 pole, 400 Amps, in open execution/Panel mounting, front operated.
(b) ON LOAD change over switch, 4 pole, 315/320 Amps, in open execution/Panel mounting, front operated.
(c) ON LOAD change over switch, 4 pole, 250 Amps, in open execution/Panel mounting, front operated.
(d) ON LOAD change over switch, 4 pole, 200 Amps, in open execution/Panel mounting, front operated.
(e) ON LOAD change over switch, 4 pole, 160 Amps, in open execution/Panel mounting, front operated.
(f) ON LOAD change over switch, 4 pole, 100 Amps, in open execution/Panel mounting, front operated.
S&F in repair including connecting and testing of change over switch OFF LOAD type in sheet metal enclosure with side handle operation of following capacity, 415 volts, AC supply confirming to IS : 13947( Part I & III ) complete all as specified and directed :-
(a) Change over switch OFF LOAD type 400 Amp, 4 pole.
(b) Change over Switch OFF LOAD type, 320 Amps, 4 pole.
(b) Change over Switch OFF LOAD type, 200 Amps, 4 pole.
(c) Change over switch OFF Load type 100A, 4 pole.
(d) Change over switch OFF Load type 63A, 4 pole.
Disconnecting electric connection & taking out connected panel & earthing from foundation of DG Set capacity of up to 63 KVA with Acoustic enlosure without canopy from foundation with panel, loading in vehicle for shifting to any site within Tech Area not exceeding 3.0 Km unloading & at location complete all as specified and directed .
Taking out and dismantling Cable any size upto 120 sqmm any description complete all as specified and directed.
Installation, commissioning and testing of DG set Capacity 62.5 KVA including Plain cement concrete( PCC) 1:3:6 Type C 2 (Using 40 mm graded stone aggregate ) as in fountation,with hight not less 3 feet , filling & mass concrete complete with foundation nut,bolt washers all as specified and directed .
Supplying ,Laying and jointing XLPE insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes :- (a) 95 Sqmm 3.5 core
(b) 70 Sqmm 3 .5 core
Excavation in trenches in soft loose soil not exceeding 1.5 m deep and not exceeding 1.5 m width and getting out including forming bottom surface for laying cables/pipes all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm thick after the cables are laid, jointed & tested complete all as specified and directed
Removing of surplus excavated soil not exceeding 50 M distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Supply & Laying precast PVC cable concrete cable cover LV voltage type -I flat size 250 mm x 150 mm x 40 mm complete all as specified and directed.
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed.
Disconnecting, dismantling top cover of oil cooled servo controlled voltage stabilizer 3 Phase, 415 voltage balance/unbalance type oil cooled/air cooled for reparing including taking out/draining of oil if required, keeping in safe custody in dry container for refilling after dehydration/replacement of defective parts including refixing of serviceable parts with and including minor parts such as lugs, washers, nuts, bolts etc, desladging of bottom, resemmbling, connecting and testing of following capacity :- Note : The major spares, if any, shall be miasused repaid under relevant item of schedule here-in-after.
(a) up to 63 KVA .
(b) 100 KVA to 200 KVA
(c) 250 KVA to 400 KVA
Supply only the following items for oil cooled servo controlled voltage stabilizers to be fixed under item No 23.00 here-in-before complete all as specified and directed.
(a) Variac coil of copper (autotransfer/dimmer coil) complete single phase of 150 Amps
(b) Packing sheet of Variac 100 to 150 Amps
(c) Carbon brush 150 Amps.
(d) Carbon brush 100 Amps
(e) Variac arm of 150 Amps
(f) Variac arm of 100 Amps
(g) Servo Motor 10 Kg - cm 60 RPM, Single Phase, 230 Volts
(h) RC network 10 kg cm
(j) PCB suitable upto 63 KVA
(k) PCB suitable 75 to 150KVA
(l) PCB suitable for 200 to 400 KVA
(m) Carbon brush 60 Amps
(n) Oil cooled Dimmer State model 60 D - 1F of make AE (Variac coil of 60 Amps)
(o) Variac coil of 28 Amps
(p) Packing sheet of Variac
(q) Carbon brush 30 Amps.
(r) Variac arm of 30 Amps
(s) Servo Motor 3 Kg 60 RPM, Single Phase, 230 volts
Supply and fixing in replacement of overload protection relay for the following capacity of stabilizers :-
(a) Upto 63 KVA
(b) 100 KVA to 200 KVA
(c) 250 KVA to 400 KVA
M/S YOGANSH CONSTRUCTION CO.
KPELECTRICAL AND AUTOMATION
SHRI RAM CONSTRUCTION
lodhi builders
UNIVERSAL AGENCY
M/s Yashika Enterprises
ISHWAR ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .