Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC | ₹7.5 L | L1 | Accepted-AOC AOC ISSUED |
| 2 | L2₹8.6 LRejected-Finance 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | ₹8.6 L | L2 | Rejected-Finance that the bid is not L1 |
| 3 | L3₹8.6 LRejected-Finance 24 C GOABAGAN LANE KOLKATA 700006 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700006 | ₹8.6 L | L3 | Rejected-Finance that the bid is not L1 |
Tender Value
₹8.9 L
EMD Value
₹17,760
Closing Date
3 Dec 2025, 1:00 pmClosed
EE-II KNHED PWDte.
KIT Building Annex, 4thFloor,P-16, India Exch. Place Extn., Kolkata -700073
Repair and Renovation Work at the Chamber of Principal, Medical College, Kolkata......... Electrical, A.C and Fire Detection Installation Work
2025_WBPWD_944543_1
WBPWD/EE-II/KNHED/NIQ-51/2025- 26
Open Tender
ELECTRICAL WORKS ORG
15 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹17,760
OFFICE OF THE EE KNHED PWDte.
15 Jan 2026
10 Nov 2025
5 Dec 2025
10 Nov 2025
3 Dec 2025
17 Nov 2025
14 Nov 2025
Amount
PART -I --- Electrical Installation Work. EI work:-- Dismantling the existing E.I. work by Co's own tools & tackles and take unnecessary items away from site by maintening normalcy as far as possible as per direction of EIC .
A. Distribution wiring:--- Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (MK: Havells/ Polycab/KEI/ Glostar) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (make--Anchor Roma plus / Legrand-Myrius / Schneider-Zencelo/Wipro- NOWA/ABB Ivie) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 12 mtr
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (MK: Havells/ Polycab/KEI/ Glostar) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Anchor Roma plus / Legrand-Myrius / Schneider-Zencelo/Wipro- NOWA/ABB Ivie) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] Average run 12 mtr.
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (MK: Havells/ Polycab/KEI/ Glostar) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Anchor Roma plus / Legrand-Myrius / Schneider-Zencelo/Wipro- NOWA/ABB Ivie) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC. i) On Board
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works a) 19 mm dia 3 mm thick polythene pipe without earth continuity wire. [3(a)/E-2]
Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works a) 25 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (MK: Havells/ Polycab/KEI/ Glostar) of the following sizes in the prelaid polythene pipe as per GS. a) 3 x (1.5 sqmm) [1(b) / E- 9]
b) 2x(2.5 sqmm)+1x(1.5 sqmm) For computer board & power plug [ 1(s) / E-9 ]
c) 2x(4 sqmm)+1x (2.5 sqmm) [ 1(v) / E- 9 ]
d) 2x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC For connection of HTPN To SPNDB
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (MK: Havells/ Polycab/KEI/ Glostar) in 20/25 mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required a) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
b) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
c) 2x(4 sqmm)+1x (2.5 sqmm)
d) 2x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC For connection of HTPN To SPNDB
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes .vide pg no F-5 item no. 9 a) 2.5 sqmm
b) 4 sqmm
c) 6 sqmm
B. BDB, PDB, VTPN etc:--- Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand/ ABB/ Schneider/ Siemens ) a) 6 Way [ 14 / D- 10 ]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. a) 2+12 Way ( Make - Legrand/ ABB/ Schneider/ Siemens ) [ 13 / D- 9 ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS ( Make - Legrand/ ABB/ Schneider/ Siemens ) a) 40A DP [ 6 / D- 5 ]
b) 100 A FP [ 6 / D- 5 ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connections per GS ( Make - Legrand/ ABB/ Schneider/ Siemens ) a) 6-32 SP [ 7 / D- 6]
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment ( Make - Legrand/ ABB/ Schneider/ Siemens ) a) 6way HTPN
C. Plug & Sockets:--- Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (make--Anchor Roma plus / Legrand-Myrius / Schneider-Zencelo/Wipro- NOWA/ABB Ivie), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 3 nos. 6 A, 3 pin Modular type plug socket with 3 nos. 6A Modular type switch & 1 nos. 16 A, 3 pin Modular type plug socket with 1 nos. 16A Modular type switch (make--Anchor Roma plus / Legrand-Myrius / Schneider-Zencelo/Wipro- NOWA/ABB Ivie), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 1 NO 16 A, 3 pin Modular type plug socket (make--Anchor Roma plus / Legrand-Myrius / Schneider-Zencelo/Wipro- NOWA/ABB Ivie) with 16A Modular type switch, without plug top & 1 nos. 6 A, 3 pin Modular type plug socket with 1 nos. 6A Modular type switch on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 2 NO 6 A, 3 pin Modular type plug socket (make--Anchor Roma plus / Legrand-Myrius / Schneider-Zencelo/Wipro- NOWA/ABB Ivie) with 2 nos 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
D. Supply of cables :--- Supplying and Delivery of following sizes Al. armoured PVC/XLPE cable (Havells/glostar/KEI) as mentioned below : a) 4 core 35 sqmm (from VTPNDB to PDB)
E. Laying of cables :--- Laying of 4 core 35 sqmm Al. armoured PVC/XLPE cable (Havells/ Glostar /KEI) with 2X10 SWG GI wire making hole etc. as necy., mending good damages and painting as mentioned below : (from VTPNDB to PBDB) Vide page no F-1,F-3 Item no 2 & 5 a. on wall by clamp
b. Concealed in wall
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : vide pg no F-4 item no. 7.C a) 4 core 35 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials . vide pg no F-5 item no. 8a & 9 : a) 4 core 35 sqm
F. Supply of Light Fittings :--- S/D 4feet single commercial LED type fluroscent light fittings (make-- Philips TMC 502 1xT-LED 22W/ CG Eco-I IGP161LT8-16 1XT8/Wipro WIO921208P/Bajaj BLRB-DB-118) complete with all accessories with 1X18/20 Wt LED tube lamp corresponding to(Make- Philips MAS LED Tube 18W, 2100lm 865 T8 (ve)/ Wipro LL13-181-65SESL1-G1/Bajaj BLRB 20W CW LED)
S & D recessed & surface mounted decorative LED ceiling tile 36 Wt (2'X2' ft) (Make Philips RC380B LED36S-6500 G6 L60W60 PSU OD/ Wipro LM10-451-XXX-65-G2/ Bajaj BZRSQL - 36 wt LED GX WH) incl. S & F flat difcuser complete set.
S&F of Eco Accent Track mounted accent lighting luminaire (with 1 mtr. Length Track) in presure diecast housing with lumen pack. MK: philips, cat no: ST271T LED40/830 PSU-E MB 1C WH or equivalent of Wipro/Bajaj
S&F of Flex cove LED strip with IP44 & 30000burning hours. Mounting accessories including AL Channel , PC Diffuser, leader cable & mounting clips & Driver. MK: Philips, Flex cove G4, Cat NO: LS17OS LED16 827 IP20 L5000PRO or equivalent of Wipro/Bajaj
G. Fixing of Light Fittings :--- Fixing only single/twin fluorescent light fittings suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp (125mmx125mm) as per G S Vide page no C-2, Item no 17
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length as per G S Vide page no C2 Item no 16
Fixing only recess type 2'x2' LED luminaire in false ceiling by S&F GI wire from ceiling with anchor fasner or bullet, nut, bolt etc. and necy. connection by S&F of 2 x1.5mm² PVC insulated Cu. Wire as per direction of EIC.
H. Supply of fans :--- S & D 230V,1200mm sweep ceiling fan, air delivery 230 CMH, (make-- Usha Striker 1 star/CG Hi speed (HS) 1 star/Orient Falcon-425 SHS) complete with blades, canopy, fork, rubber bush, down rod, 1000mm safety wire & S3 capacitor etc.
S & D 230 V 50 HZ, 98watt, 18" (450 mm) high flo ( air delivery-- 100 cm/min, RPM-- 1350) non-oscillating type metal body Wall Bracket fan with inbuilt regulator, (Make -CG, SSTORM 2 Plus WM)
S & D 230V, 1420 RPM heavy duty exhaust fan (Make -- USHA,S.Ph TURBO Heavy duty,1400RPM,ISI Grey/ Orient Heavy duty/CG EXHD300-4-1) of following sizes 15" (380mm)
I. Fixing of fans :--- Supply & Fixing 240V, fan regulator (Step type) (mk-Anchor) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush, etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire as per G.S. Vide page no C-3, Item no 21.a.
S & F fan down rod (14 SWG) incl. necessary connection wire (2X1.5sqmm cu wire) and painting the down rod as per direction of EIC
fixing only 18" (450 mm) Wall Bracket fan on (10'' x 12'' ) size wooden board in built on wall by S & F rag bolts ,nuts and washers (6 mm dia x 62 mm long) or as required incl. S & F 24/.20 PVC insulated flexible copper wire 0.5 mt. Length as per direction of EIC.
fixing only 15" (38 cm) exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of dia incl. S&F of GI louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS
K. Miscellaneous :--- Supply and installation of 1-Phase timer in double door SPN DB (2+10) way providing incoming and outgoing copper wires and other accessories. The interconnection should be made by 4 sq.mm. copper wires. The box should be painted by powder coated paint. a) 25A DP MCB -1 No. (b)Analog time switch - 1 No. (c) 2-pole 30A single phase power contactor, - 1 No. (d) Add-on auxiliary contact block(1 NO+1 NC) -1 no (e) 60A capacity 3 way AC/DC Epoxy terminal block.- 1 No. (f) Indicator Lamp (ESBEE make)-2 Nos. (g) Toggle switch,(ON_OFF_ON)- 1 No. (h) Steel Key Lock – 1 No. (Make- LK /ABB)
S & Installation of 25A 3 pin Modular type Power Socket with plug top with indicator in 2 module GI modular type switch board with top cover plate flushed in wall incl. making necy. Connection with PVC Cu wire & earth continuity wire etc. for RAC machine. (Mk. Legrand).
Supply & fixing 250V control starter type OLP 30M, 11-21A range, starter with AC looad display (make-- ultratech/Electron) incl. S&F of 6 module modular box
PART -II ---A.C Installation Work. Supply & delivery 2.0 TR capacity Normal Split type Air Conditioner of rated cooling capacity of 24000 BTU/hr, with 1 No. Rotary compressor, 1 No. IDU of rated power supply - 230V - 1ph-50Hz, 1 No. ODU of rated power supply - 230V, 1ph, 50 Hz, Air-flow/per IDU :- 800cfm, (Gas : R32/R410A )(Make : O-General/ /Mutsubishi Heavy/Daikin)
Erection, testing and commissioning charges for the above said 2.0 / 1.5 TR concealed Split / normal split AC. The Indoor (IDU) & Outdoor (ODU) unit must be supported by structure made of 40 x 40 x 5 mm amgle and tie rod incl. necy. Painting & as per direction & satisfaction of EIC.
Copper Refrigeration pipe line for Liquid Line hard drawn Cu piping (1/4" OD with 0.6 mm thick) & Copper Refrigeration pipe line for Suction Line hard drawn Cu piping (5/8" OD with 0.7 mm thick) with necy supports & brackets as per direction of EIC
Supply & Fixing of Nitrile Rubber tube insulation (make : Twiga/ supreme) of 9 mm thick on Suction & Liquid Line Copper Pipe.
Control Cabling from Condensing Unit to Control Panel, 4 core 2.5 sq.mm. communication Cable (Mk. Finolex / Havell's)
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. CPVC Pipes Class-1, SDR-11 of dia PWD Sch S&P P-29, Item no-1(a) (make-- Finolex/ Oriplast/ supreme) 25mm
Charges for Scaffolding arrangement including lifting for outdoor & indoor units.
FRAME WORK Enclosed Safety Cage for ODU :: Supplying, fabrication & fixing 3 Nos. M.S U-channel of 6mm thick of size (75mm X 40 mm X 40mm) of 1m length for making platform for installation of outdoor unit of 8.5TR / 5.5TR ductable split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 1/2:3) etc. fabricated with 2 Nos. horizontal angle of 25mm X 25mm X 5mm of 1m. length incl. S&F of enclosed safety cage (for ODU) made of angle (25 X 25 X 5 mm) and flat (25 X 5 mm) iron with necessary painting with 02 coat of R.O. primer (Asianpaint / Shalimer / Berger) incl. shade arrangement with corogated PVC shade with proper clamping arrangement incl. fixing of ODU as pr direction of EIC.
Cu Pipe Line Safety Grill Enclosure :: S & installation of rectangular type M.S frame of size 1’ x 1’ x 1’ of 25 mm M.S flat with 02 nos interconnections by 25 x 6 mm M.S.flat with 25 x 25 x 5 mm M.S angle with suitable clamping arrangement as required. All angle are jointed by argon welding system. M.S. bar gap at 2’’ distance. Whole structure are grouted on wall at each 18" gap with 3" M.S. flat leg splitted at end ( 4" bullet fastener are to be used where grouting will not be possible) and mending good the damage to original finish incl all necy. materials, tools and tackles incl charges of scaffolding and painting with 02 coat of Synthetic enamelled paint over 02 coat of R.O. primer (Asian Paint / ICI / Berger) incl. welding, carriage and transportation.
Wrapping both the copper pipe with kenofoam insulation by 26 SWG aluminum sheet to make it vermin proof.
Dismentaling the existing A.C Machine (including electrical connection) both indoor & outdoor and submit the pwd section office as per direction of EIC
PART-III ---- Fire Detection System installation work . One time rectification/cleaning contract of following types of Addressable type fire detection system(Make- siemens) as mentioned below. (Labour Cost) a) Multi Detector/Heat detector
c) Hooter
d) Repeter Panel / main panel
e) Module
Re-commissioning charge of existing Addressable type fire detection panel (Make- siemens) after rectification of all fault & connected news devices; submit a commissioning report as per direction of EIC
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : Cerberus Pro)
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Heat detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have maimum triggering temperature programmable from 60 deg. C to 80 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. (Approved Make : Approved Make : Cerberus Pro)
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Approved Make : Cerberus Pro)
Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL /ERTL/ LPCB / FM approved) approved. (Approved Make: Cerberus Pro)
Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL /ERTL/ LPCB / FM approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make : Cerberus Pro/Agni Suraksha )
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/Havells/Polycab ) with 20 mm NB PVC rigid conduit pipe(Make: Precision /AKG/ATUL /VIP/ Universal /BEC/Polycab) on the surface of the wall.
SITC of Conduit PVC (20mm) (Make: Polycab / Precision (M))
(Rate should be quotated including all taxes and duties, GST .)
M/S R. K. ENTERPRISE (BID ID -7400692)
ALPHA ELECTRICALS (BID ID -7452154)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.45 MB
BOQ_2242520.xls
BOQ • 0.40 MB
suspension.pdf
Additional Documents • 2.91 MB
2911.pdf
Tender Documents • 1.46 MB
Download all tender documents and submit your bid