Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC H NO 1 7 1 79 1 ROAD NO 7 REDDY ENCLAVE TEMPLE ALWAL SECUNDERABAD 500 010 | HYDERABAD | TELANGANA | 500010 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹17.7 L+₹2.7 L (17.9%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹17.8 L+₹2.7 L (18.3%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹18.1 L+₹3.0 L (20.2%)Rejected-AOC | L4 | Rejected-AOC Not a lowest bid | |
| 5 | L5₹17.5 L+₹2.4 L (16.2%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
11 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MCEME Secunderabad
GE MCEME Secunderabad MCEME Campus, Trimulgherry (Post) Secunderabad - 500 015
PRE MANSOON ROOF MAINTENANCE REPAIRS TO BLDG AND ASSETS AT ZONE II AREA UNDER GE MCEME SECUNDERABAD
2021_MES_413244_1
GE/MCEME/32 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
Secunderabad
Class E Category a(I)
6 documents required · 6 mandatory
₹500
GE MCEME Secunderabad
₹40,000
Yes
18 Mar 2021
16 Jan 2021
13 Feb 2021
16 Jan 2021
11 Feb 2021
29 Jan 2021
60 days
Amount
Demolition of Lime concrete/ Mud phuska/ PCC of any description and in any position not otherwise specifically provided for renewal including removal of demolished material beyond the Md land to a distance exceeding 500 mtr not exceeding 1.5 KM complete all as specified and directed
M&L 25mm thick (average thickness) plain cement concrete 1:2:4 type B-0 using (12.5mm graded aggregate), mixed with WPC @ 3.00 kg by weight of cement as in roof, padding to maintain the uniform slope complete all as specified and directed. Note : WPC shall be measured & paid separately.
M&L for rendering 10mm thick in CM 1:4 on concrete surfaces and finished even smooth without using extra cement complete all as specified and directed
Supply only Integral water proofing compound complete all as specified and directed
M&L priming the surfaces by applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2kg per sqm including cleaning surfaces complete all as specified and directed
M&L providing water proof treatment by applying bituminious primer 0.30 kg/sqm and laying APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3mm thick reinforced with polster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surfaced by forced applicaion complete all as specified and directed by Engr-in-Charge.
Taking up or down 15mm steel tubing and including cleaning for refixing or removal to store complete all as specified and directed
S&F 15mm bore tubes medium grade galvanised with all fittings and fixed complete to walls or laid in floors complete all as directed by Engr-in-Charge
Refixing for 15mm bore steel tubing and connections in new or old positions (walls, ceiling, floors etc) complete all as directed by Engr-in-charge
Taking up or down 20mm bore steel tubing and including cleaning for refixing or removal to store complete all as specified and directed
S&F in 20mm tubes medium grade galvanised with all fittings and fixed complete to walls or laid in floors bore of pipe complete all as specified and directed
Refixing for 20mm bore steel tubing and connections in new or old positions (walls, ceiling, floors etc) complete all as specified and directed
Taking up or down 25mm bore steel tubing and including cleaning for refixing or removal to store complete all as specified and directed
S&F 25mm bore of tubes medium grade galvanised with all fittings and fixed complete to walls or laid in floors bore of pipe complete all as specified and directed
Refixing for 25mm bore steel tubing and connections in new or old positions (walls, ceiling, floors etc) complete all as specified and directed
S&F in repairs 15mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plstic ball screw for pipe and fixed complete all as specified and directed.
S&F in repairs 20mm dia ball valves high pressure PTMT with epoxy coated aluminium rod and high density plastic hall screw for pipe and fixed complete all as specified and directed
Taking down cement plaster or cement lime plaster of any description including racking out joints and hacking for key and scrubbing down with water etc.complete all as specified and directed
M&L for rendering 15mm thick in concrete surfaces of walls in CM 1:6 finished even smooth without using extra cement complete all as specified and directed
M&L for Rendering 5 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.in ceilling
M&L for preparation of new undecorated surfaces of ceiling and applying three coat of white wash complete all as specified and directed
M&L for rendering 15mm thick in CM 1:4 on brick wall of concrete and finished even smooth without using extra cement complete all as specified and directed
M&L for preparation of two coat of OBD over a coat of chalk whiting on plastered surfaces of primer on newely plastered surfaces of walls complete all as specified and directed
M&L for preparation of two coat of cement base paint over a coat of alkali resistant primer on newely plastered surfaces of walls complete all as specified and directed
Dismantling of 1000 ltr water storage tanks and removed to store complete all as specified and directed
Dismantling of 500 ltr water storage tanks and removed to store complete all as specified.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting and reconnecting and re-fixing in position (Cleaning repairing etc. measured separately) Upto 500 ltr capacity tanks)complete all as specified and directed
Cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes with bleaching poder exc 250 ltr and n.exc 500 ltr complete all as specified and directed
Cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes with bleaching poder exc 500 ltr and n.exc 10000 ltr all as spd and directed
S&F 1000 ltr capacity of rotational moulded PVC water storage tank (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed. NOTE: Temporary water arrangement should be provided by the contractor during execution of work.
All as per item no 30 above but tank capacity 500 ltr.
S&F 15mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plstic ball screw for pipe and fixed complete all as specified and directed.
S&F 20mm dia ball valves high pressure PTMT with epoxy coated aluminium rod and high density plastic hall screw for pipe and fixed complete all as specified and directed
Taking down eaves, gutters and rain water pipes including all fittings any size and pattern complete all as specified and directed
S&F PVC (SWR) 100/110mm bore single socketed pipes in any length with rubber ring joints fixed to wall with pvc clamps complete.
S&F in repairs PVC(SWR) bend/shoe for 100/110 mm dia complete all as specified and directed
S&F in repairs PVC(SWR) bend/shoe for 150/160 mm dia complete all as specified and directed
Demoition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed
M&L for PCC 100mm thick type D2, 1:4:8, 40mm graded agg as in sub base complete all as specified and directed
M&L 40mm th for PCC 1:2:4 type B1, 1:2:4, 20mm graded aggregates as in finishing of concrete even and smooth using extra cement complete all as specified and directed
M&L for removing loose and broken concrete by chiselling /picking etc upto a depth of 10 to 20mm from floor/ roof slab/ chajjas/ceiling and similar structural members cleaning the dismantled portion with wire brushes etc to remove dust, dirt and other foreign particles including necessary scaffolding etc and removal of debris to a distance not exceeding 50m, complete all as specified and as directed by Engineer-in-Charge.
M&L for application of high build polymer modified cement mortar (1:2.5) mixed with 3 kg SBR per bag of cement in ceiling surfaces 10 to 20mm thick in two layers surfaces over a coat of bonding agent Nito Bond SBR (1 Ltr SBR + 1 Ltr) water + 3 kg cement), complete all as specified and as directed by Engineer -in-Charge.
Dismantling Asbestos cement (corrugated semicorrugated) sheet in roof coverings complete all as specified and directed
M&L for 6mm thick Asbestos cement sheet corrugated or semi-corrugated sheets in roofs walls fixed with L type or J type or Cranked hooks bolts complete all as specified and directed
M&L for Asbestos cement one piece plain angular ridge fixed with L type or J type or Cranked hooks bolts complete all as specified and directed
Labour only for fixing of Asbestos cement sheet corrugated or semi-corrugated sheets in roofs walls fixed with L type or J type or Cranked hooks bolts complete all as specified and directed
Dismantling plain or corrugated steel sheeting, AC Sheets any guage, thickness including Nainital or similar pattern roof covering/wall cladding complete all as specified and directed.((Note : height of the bldg truss is upto 6 mtr)
S & F pre painted galvalume aluminium zinc coating GI based corrugated steel sheets 0.50 mm thick any colour having tensile strength 0f 550 Mpa as in roof covering/wall cladding to walls, fixed with self tapping screws as specified and directed. Note ; ht of the bldg is upto 7 mtrs
S & F 0.50mm thick plain galvanised, mild steel sheeting ,in ridges,hips,valley gutters,drip and straight flashings (length and girth as fixed) with grade of zinc coating by manufactureres instruction or directed by Engr-in-Charge
Dismantling structural steel work including doors, gates,etc all as specified and directed by Engineer in Charge
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming tofe -410W (gde E-250) quality complete all as specified and directed
S&F Rolled mild steel in joist ,channel angle or tee section, flat iron fixed independently quality conforming to Fe 410W(Gde-250) complete all as specified and directed
M & L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 etc complete all as specified and directed
Uprooting of vegetation growthl, shurbs, small plants and small trees of any size/girth from walls, roof chajja gutter, up to four storey at any location and position of bldg completely including roots and making good the disturbed surfaces cleaning the surfaces and making good holes with cement mortar (1:3) with WPC @ 3.00 kg by weight of cement, each hole not exc 0.10 Sqm complete all as specified and directed Note : Rate including WPC
M/S DIVIJA BUILDERS
HRML CONSTRUCTIONS
NEWS CONSTRUCTIONS
SURA INFRASTRUCTURE
VACON INFRASTRUCTURES
M/s Bhavani Constructions
Sri Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .