Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | ₹14.5 L Quoted ₹15.4 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹15.9 L+₹47,852 (3.10%)Rejected-Finance RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | ₹15.9 L+₹47,852 (3.10%) | L2 | Rejected-Finance Being other than lowest |
| 3 | L3₹16.9 L+₹1.5 L (9.48%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | ₹16.9 L+₹1.5 L (9.48%) | L3 | Rejected-Finance Being other than lowest |
| 4 | L4₹17.6 L+₹2.1 L (13.9%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | ₹17.6 L+₹2.1 L (13.9%) | L4 | Rejected-Finance Being other than lowest |
| 5 | L5₹17.7 L+₹2.2 L (14.6%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹17.7 L+₹2.2 L (14.6%) | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
29 Nov 2024, 6:00 pmClosed
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
COMPRESENSIVE MAINTENANCE INCLUDING REPAIR/ REPLACEMENT OF UNSERVICEABLE PARTS OF COLD ROOM, TOWER ADS DUCTABLE ACS AND CONNECTED MISC E/M WORKS AT BASE HOSP, AFTC AND AFMSD UNDER GE (EAST) DELHI CANTT-10
2024_MES_682991_1
GE/DE-90/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE (EAST) DELHI CANTT-10
Class D Cat c (i)
8 documents required · 8 mandatory
₹500
Yes
GE (EAST) DELHI CANTT-10
₹80,000
Yes
20 Jan 2025
8 Nov 2024
2 Dec 2024
8 Nov 2024
29 Nov 2024
22 Nov 2024
Amount
S&F in repair Controller Suitable for Cold Chamber of any make and model complete all as specified and as directed. Make: Blue Star/ Carrier/ Ice Make.
S&F in repair IDU axial fan complete set suitable for cold room of following model complete all as specified and as directed:-
IDU axial fan complete Set, suitable for cold chamber (Model No-RAUH0-2012 KP-I). Make: Blue Star/ Carrier/ Ice Make.
IDU axial fan complete Set, suitable for cold chamber (Model No RAUH0-1015 KP-I). Make: Blue Star/ Carrier/ Ice Make.
IDU axial fan complete Set, suitable for cold chamber (Model No RAUH0-1012 KP-I). Make: Blue Star/ Carrier/ Ice Make.
S&F in repair Outdoor Unit Fan Motor SP 230V/415V Suitable for cold chamber of following model complete all as specified and as directed:-
Outdoor Unit Fan Motor, SP 230V/415V suitable for cold chamber (Model No RUAH0-2012 KP-O). Make: Blue Star/ Carrier/ Ice Make.
Outdoor Unit Fan Motor, SP 230V/415V suitable for cold chambers (Model No RUAH0-1015 KP-O). Make: Blue Star/ Carrier/ Ice Make.
Outdoor Unit Fan Motor, SP 230V/415V suitable for cold chambers (Model No RUAH0-1012 KP-O). Make: Blue Star / Carrier/ Ice Make.
S&F in repair ODU Fan Blade Set suitable for fan motor of sweep- 300mm of following model complete all as specified and as directed:-
ODU Fan Blade Set suitable for cold chamber (Model No RUAH0-2012 KP-O). Make: Blue Star/ Carrier/ Ice Make.
ODU Fan Blade Set suitable for cold chamber (Model No RUAH0-1015 KP-O). Make: Blue Star/ Carrier/ Ice Make.
ODU Fan Blade Set suitable for cold chamber (Model No RUAH0-1012 KP-O). Make: Blue Star/ Carrier/ Ice Make.
S & F in replacement Compressor working on 230 Volt, AC, single phase complete duly filled with capila 'D' including supply and charging the refrigerant gas to the required capacity including flushing the complete refrigerant system after leak detection and replacing the filter complete for cold chamber of following models complete all as specified and directed:-
Compressor suitable for outer door unit 40000 BTU/Hour ( Cold chamber Model No- RUAH04012KP-O). Make: Blue Star/ Emerson Copeland/ Danfoss
Compressor suitable for outer door unit 20000 BTU/Hour ( Cold chamber Model No- RUAH0-2012 KP-O). Make - Blue Star/ Danfoss/ Emerson Copeland.
Compressor suitable for outer door unit 15000 BTU/Hour ( Cold chamber Model No- RUAH01015KP-O). Make: Blue Star/ Emerson Copeland/ Danfoss
Compressor suitable for outer door unit 10000 BTU/Hour ( Cold chamber Model No- RUAH01012KP-O). Make: Blue Star/ Emerson Copeland/ Danfoss
S&F in repair Evaporator Coil suitable for Cold Chamber IDU of following models complete all as specified and as directed:-
Evaporator Coil suitable for cold chamber (Model No RUAH0-2012 KP-I). Make : Blue Star /Carrier/ Ice make.
Evaporator Coil suitable for cold chamber (Model No RUAH0-1015 KP-I). Make : Blue Star/ Carrier/ Ice make.
Evaporator Coil suitable for cold chamber (Model No RUAH0-1012 KP-I). Make : Blue Star/ Carrier /Ice make.
S&F in repair Condenser Coil, Size 24 inch and 2 Row suitable for Outdoor Unit of Cold Chamber of following models complete all as specified and as directed:-
Condenser Coil suitable for cold chamber (Model No RUAH0-2012 KP-O). Make : Blue Star/ Carrier/ Ice make.
Condenser Coil suitable for cold chamber (Model No RUAH0-1015 KP-O). Make : Blue Star/ Carrier/ Ice make.
Condenser Coil suitable for cold chamber (Model No RUAH0-1012KP-O). Make : Blue Star/ Carrier/ Ice make.
S&F in repair Service Valve 7/8'' suitable for ductable AC/cold chamber of any make and model complete all as specified and as directed. Make : Blue Star/ Carrier/ Ice make.
S&F in repair Service Valve 5/8'' suitable for ductable AC/cold chamber of any make and model complete all as specified and as directed. Make : Blue Star/ Carrier/ Ice make.
S&F in repair Service Valve 6/8'' suitable for ductable Ac/cold chamber of any make and model complete all as specified and as directed. Make : Blue Star/ Carrier/ Ice make.
S&F in repair Service Valve 3/8'' suitable for ductable AC/cold chamber of any make and model complete all as specified and as directed. Make : Blue Star/ Carrier/ Ice make.
S&F in repair Service Valve 1/2'' , 1/8'' suitable for ductable AC/cold chamber of any make and model complete all as specified and as directed. Make : Blue Star/ Carrier/ Ice make.
S&F in repair copper tubing 7/8" dia & wall thickness- 20 SWG with required insulation complete all as specified and as directed. Make: Totaline/ Godrej or equivalent.
S&F in repair copper tubing 6/8" dia & wall thickness- 22 SWG with required insulation complete all as specified and as directed. Make: Totaline/ Godrej or equivalent.
S&F in repair copper tubing 5/8" dia & wall thickness-20 SWG with required insulation as per site requirement complete all as specified and as directed. Make: Totaline/ Godrej or equivalent.
S&F in repair copper tubing 3/8" dia & wall thickness- 16 SWG with required insulation complete all as specified and as directed. Make: Totaline/ Godrej or equivalent.
S & F in replacement copper tubing ½” dia & wall thickness - 22 SWG with required insulation complete all as specified & as directed. Make: Totaline/ Godrej or equivalent
S & F in replacement copper tubing 1/4” dia & wall thickness - 22 SWG with required insulation complete all as specified & as directed. Make: Totaline/ Godrej or equivalent
Supply and charging of refrigerant gas R-22, of suitable grade after carrying out the pressure test with nitrogen and rectify the leakage of cold chamber/ductable AC/tower ac complete all as specified and as directed.
Supply and charging of refrigerant gas of suitable grade R-407C after carrying out the pressure test with nitrogen and rectify the leakage of cold chamber/ductable AC/tower ac complete all as specified and as directed.
Supply and charging of refrigerant gas of suitable grade R-410 after carrying out the pressure test with nitrogen and rectify the leakage of cold chamber/ductable AC/tower ac complete all as specified and as directed.
S&F in repair strainer 3/8" for cold chamber of suitable size and make as per existing site complete all as specified and as directed. Make-Blue Star/Carrier/ Ice make.
S&F in repair strainer 5/8" for cold chamber of suitable size and make as per existing site complete all as specified and as directed. Make-Blue Star/Carrier/ Ice make.
S&F in repair watch timer switch single phase 2400 Hrs, 16 Amps for cold chamber including necessary wiring complete all as specified and as directed. Make : L&T/GIC(FM1 series) or equivalent.
S&F in repair expansion valve suitable for cold chamber of suitable size as per site requirement complete all as specified and as directed. (Model No. RUAHO-1012 KP-1) Make- Danfoss/Indfoss/Sporlon/Alco.
S&F in repair expansion valve suitable for cold chamber of suitable size as per site requirement complete all as specified and as directed. (Model No. RUAHO-1015 KP-1) Make- Danfoss/Indfoss/Sporlon/Alco.
S&F in repair expansion valve suitable for cold chamber of suitable size as per site requirement complete all as specified and as directed. (Model No. RUAHO-2012 KP-1) Make- Danfoss/Indfoss/Sporlon/Alco.
M&L for servicing, and cleaning of condenser/evaporator of out door and indoor unit of cold chamber respectively with suitable chemical detergent and acid using pump, washing the same with water by using pump set of 110 feet head and making clear and clean all the tubes , fins and other parts and then clear with suitable dry air blower, Checking and tightening of all electrical connection and making fully serviceable including top up of refrigerant Gas complete all as specified and as directed.
Attending the break down/ complaint of all nature including wiring of panels and all others mentioned below for walk in cooler of base hospital and carry out the required repairs, on all days including Sunday and holidays complete all as specified and as directed. Note- (i)The spare parts required to be replaced shall be measured and paid separately as "Supply only" under respective item of this Schedule. (ii) Adequate resources shall be deployed by the contractor for attending day to day defect being an essential installation. (iii) All complaint/repairs shall be attended within 06 Hour failing which a recovery of Rs 1000/- per day per complaint shall be made from contractor dues.
Supply only in repair single phase preventer VSP-II complete all as specified and as directed. Make: Minilac/Siemens/L&T
Supply only in repair running capacitor 50 + 5 MFD complete all as specified and as directed.
M&L for servicing and cleaning of condenser/evaporator of out door and indoor unit of ductable AC respectively with suitable chemical detergent and acid using pump, washing the same with water by using pump set of 110 feet head and making clear and clean all the tubes, fins and other parts and then clear with suitable dry air blower, Checking and tightening of all electrical connection and making fully serviceable including top up of refrigerant Gas complete all as specified and as directed.
Attending the break down/ complaint of all nature including wiring of DB for ductable ac of base hospital and carry out the required repairs, on all days including Sunday and holidays complete all as specified and as directed. Note- (i)The spare parts required to be replaced shall be measured and paid separately as "Supply only" under respective item of this Schedule. (ii) Adequate resources will be deployed by the contractor for attending day to day defect being an essential installation. (iii) All complaint/repairs shall be attended within 06 Hour failing which a recovery of Rs 1000/- per day per complaint shall be made from contractor dues.
S & F in replacement scroll type Compressor for ductable AC , working on 440 Volt, AC, three phase complete duly filled with capila 'D' including supply and charging the suitable refrigerant gas to the required capacity including flushing the complete refrigerant system after leak detection and replacing the filter complete for cold chamber of following models complete all as specified and directed:-
Compressor suitable for out door unit of ductable AC of cap 8.5 TR (102000 BTU/HR), (Ductable AC Model No- DSA1021R3-OA). Make - Blue Star / Danfoss/Emerson Copeland.
Compressor suitable for out door unit of ductable AC of cap 8.75 TR (102000 BTU/HR), (Ductable AC Model No- ACDCUSC-875DGR407IM). Make - Blue Star / Danfoss/Emerson Copeland.
Compressor suitable for out door unit of ductable AC of cap 8.5 TR (102000 BTU/HR), (Ductable AC Model No- DSA1021R2-OT). Make - Blue Star / Danfoss/Emerson Copeland.
Compressor suitable for out door unit of ductable AC of cap 5.5 TR (66000 BTU/HR) ( Ductable ac Model No- DSA661R3-OA). Make - Blue Star / Danfoss/Emerson Copeland.
Compressor suitable for out door unit of ductable AC of cap 5.5 TR (66000 BTU/HR) ( Ductable ac Model No- DSA661R2-O ). Make - Blue Star / Danfoss/Emerson Copeland.
Compressor suitable for out door unit of ductable AC of cap 3 TR (9000 BTU/HR), ( Ductable ac Model No- DSA361R2-O). Make - Blue Star / Danfoss/Emerson Copeland.
All as per srl item No 40.00 here-in-before but compressor of Capacity 2 TR working on 230 V, AC, single phase (Ductable AC Model No - DSA522R3-O) complete all as specified and as directed.
S&F in repair Outdoor Unit Fan Motor of following models ductable AC complete all as specified and as directed:-
Outdoor Unit Fan Motor 3 Phase, 415V, Suitable for ductable AC (Model No - DSA1021R3-OA). Make: Blue Star /Carrier/ Ice Make.
Outdoor Unit Fan Motor 3 Phase, 415V, Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM). Make: Blue Star /Carrier/ Ice Make.
Outdoor Unit Fan Motor 3 Phase, 415V, Suitable for ductable AC (Model No - DSA1021R2-OT). Make: Blue Star /Carrier/ Ice Make.
Outdoor Unit Fan Motor 3 Phase, 415V, Suitable for ductable AC (Model No -DSA661R3-OA). Make: Blue Star /Carrier/ Ice Make.
Outdoor Unit Fan Motor 3 Phase, 415V, Suitable for ductable AC (Model No-DSA361R2-O). Make: Blue Star /Carrier/ Ice Make.
Outdoor Unit Fan Motor 3 Phase, 415V, Suitable for ductable AC (Model No - DSA661R2-O ). Make: Blue Star /Carrier/ Ice Make.
All as per item No. 42.00 here in before but fan Motor of single Phase, 230V, Suitable for ductable AC (Model No DSA522R3-O). Make: Blue Star /Carrier/ Ice Make.
S&F in Repair outdoor unit fan Blade Suitable for any make and model of ductable type AC of following model complete all as Specified and as directed:-
Outdoor Unit Fan blade Suitable for ductable AC (Model No - DSA1021R3-OA). Make: Blue Star /Carrier/ Ice Make.
Outdoor Unit Fan blade Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM). Make: Blue Star /Carrier/ Ice Make.
Outdoor Unit Fan blade suitable for ductable AC (Model No - DSA1021R2-OT). Make: Blue Star /Carrier/ Ice Make.
Outdoor Unit Fan blade suitable for ductable AC (Model No -DSA661R3-OA). Make: Blue Star /Carrier/ Ice Make.
Outdoor Unit Fan blade Suitable for ductable AC (Model No-DSA361R2-O). Make: Blue Star /Carrier/ Ice Make.
Outdoor Unit Fan blade Suitable for ductable AC (Model No - DSA661R2-O ). Make: Blue Star /Carrier/ Ice Make.
ODU fan blade Suitable for ductable AC (Model No DSA522R3-O). Make: Blue Star /Carrier/ Ice Make.
S&F in repair Indoor Unit blower of following models ductable AC complete all as specified and as directed:-
Indoor unit blower Suitable for ductable AC (Model No - DSA1021R3-OA). Make: Blue Star /Carrier/ Ice Make.
indoor Unit blower Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM). Make: Blue Star /Carrier/ Ice Make.
Indoor Unit blower Suitable for ductable AC (Model No - DSA1021R2-OT). Make: Blue Star /Carrier/ Ice Make.
Indoor Unit blower Suitable for ductable AC (Model No -DSA661R3-OA). Make: Blue Star /Carrier/ Ice Make.
Indoor Unit blower Suitable for ductable AC (Model No-DSA361R2-O). Make: Blue Star /Carrier/ Ice Make.
Indoor Unit blower Suitable for ductable AC (Model No - DSA661R2-O ). Make: Blue Star /Carrier/ Ice Make.
Indoor unit blower Suitable for ductable AC (Model No DSA522R3-O). Make: Blue Star /Carrier/ Ice Make.
Supply and fixing in repair Indoor Unit Blower Motor of following models ductable AC complete all as specified and directed:-
Indoor unit blower Motor 1 Phase, 230 V, Suitable for ductable AC (Model No - DSA1021R3-OA). Make: Blue Star /Carrier/ Ice Make.
indoor Unit blower Motor 1 Phase, 230V, Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM). Make: Blue Star /Carrier/ Ice Make.
Indoor Unit blower Motor 1 Phase, 230 V, Suitable for ductable AC (Model No - DSA1021R2-OT). Make: Blue Star /Carrier/ Ice Make.
Indoor Unit blower Motor 1 Phase, 230 V, Suitable for ductable AC (Model No -DSA661R3-OA). Make: Blue Star /Carrier/ Ice Make.
Indoor Unit blower Motor 1 Phase, 230V, Suitable for ductable AC (Model No-DSA361R2-O). Make: Blue Star /Carrier/ Ice Make.
Indoor Unit blower Motor 1 Phase, 230V, Suitable for ductable AC (Model No - DSA661R2-O ). Make: Blue Star /Carrier/ Ice Make.
Indoor unit blower Motor of 1 Phase, 230V, Suitable for ductable AC (Model No DSA522R3-O). Make: Blue Star /Carrier/ Ice Make.
S&F in repair expansion valve of following models ductable AC complete all as specified and as directed: -
Expansion valve Suitable for ductable AC (Model No - DSA1021R3-OA). Make: Blue Star /Carrier/ Ice Make.
Expansion valve Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM). Make: Blue Star /Carrier/ Ice Make.
Expansion valve Suitable for ductable AC (Model No - DSA1021R2-OT). Make: Blue Star /Carrier/ Ice Make.
Expansion valve Suitable for ductable AC (Model No -DSA661R3-OA). Make: Blue Star /Carrier/ Ice Make.
Expansion valve Suitable for ductable AC (Model No-DSA361R2-O). Make: Blue Star /Carrier/ Ice Make.
Expansion valve Suitable for ductable AC (Model No - DSA661R2-O ). Make: Blue Star /Carrier/ Ice Make.
Expansion valve Suitable for ductable AC (Model No DSA522R3-O). Make: Blue Star /Carrier/ Ice Make.
S&F in repair evaporative coil for indoor unit of ductable AC of following models complete all as specified and as directed:-
Evaporative coil Suitable for ductable AC (Model No - DSA1021R3-OA). Make: Blue Star /Carrier/ Ice Make.
Evaporative coil Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM). Make: Blue Star /Carrier/ Ice Make.
Evaporative coil Suitable for ductable AC (Model No - DSA1021R2-OT). Make: Blue Star /Carrier/ Ice Make.
Evaporative coil Suitable for ductable AC (Model No -DSA661R3-OA). Make: Blue Star /Carrier/ Ice Make.
Evaporative coil Suitable for ductable AC (Model No-DSA361R2-O). Make: Blue Star /Carrier/ Ice Make.
Evaporative coil Suitable for ductable AC (Model No - DSA661R2-O ). Make: Blue Star /Carrier/ Ice Make.
Evaporative coil Suitable for ductable AC (Model No DSA522R3-O). Make: Blue Star /Carrier/ Ice Make.
S&F in repair condenser coil for outdoor unit of ductable AC of following models complete all as specified and as directed:-
Condenser coil Suitable for ductable AC (Model No - DSA1021R3-OA). Make: Blue Star /Carrier/ Ice Make.
Condenser coil Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM). Make: Blue Star /Carrier/ Ice Make.
Condenser coil Suitable for ductable AC (Model No - DSA1021R2-OT). Make: Blue Star /Carrier/ Ice Make.
Condenser coil Suitable for ductable AC (Model No -DSA661R3-OA). Make: Blue Star /Carrier/ Ice Make.
Condenser coil Suitable for ductable AC (Model No-DSA361R2-O). Make: Blue Star /Carrier/ Ice Make.
Condenser coil Suitable for ductable AC (Model No - DSA661R2-O). Make: Blue Star /Carrier/ Ice Make.
Condenser coil Suitable for ductable AC (Model No DSA522R3-O). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement gas filter/ dryer 5/8" suitable for ductable AC of any make and model complete all as specified and as directed.
S&F in replacement PCB for IDU suitable for ductable AC of any make and model complete all as specified and as directed.
S&F in replacement capillary thermostat for controlling temperature complete all as specified and as directed.
M&L for servicing and cleaning of York mortury Chamber for capacity of 6 body respectively with suitable chemical detergent and acid using pump, washing the same with water by using pump set of 110 feet head and making clear and clean all the tubes, fins and other parts and then clear with suitable dry air blower, Checking and tightening of all electrical connection and making fully serviceable including replacement of unserviciceable parts, top up of refrigerant Gas complete all as specified and as directed.
YASHVI ENGINEERS (BID ID -3175731)
Vishal Traders (BID ID -3176990)
Saini Enterprises (BID ID -3176587)
SANJEEV ENTERPRISES (BID ID -3176061)
INDO CONSTRUCTION (BID ID -3177215)
ASHUTOSH BUILDERS (BID ID -3176525)
Singh Associates (BID ID -3175264)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .