| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC WEST BIDYUTPUR MALDA | MALDA | MALDA | WEST BENGAL | L1 | Accepted-AOC L1-Accepted | |
| 2 | L2₹8.3 L+₹3,127.77 (0.38%)Rejected-Finance MAHESMATI MALDA | L2 | Rejected-Finance Higher than L1 | |
| 3 | L3₹8.3 L+₹3,669.05 (0.44%)Rejected-Finance BHIAGRAM ENGLISH BAZAR MALDA | MALDA | L3 | Rejected-Finance Higher than L1 | |
| 4 | L4₹8.3 L+₹4,915.06 (0.60%)Rejected-Finance 21 KBM CHAKDAH P O P S CHAKDAH DIST NADIA PIN 741222 | CHAKDAH | NADIA | WEST BENGAL | 741222 | L4 | Rejected-Finance Higher than L1 |
Tender Value
₹8.5 L
EMD Value
₹17,011
Closing Date
5 Sept 2022, 2:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER, MALDA MECHANICAL DIVISION, PHE
Office of the Executive Engineer, Malda Mechanical Division, PHE Dte. Doulatpur PHE complex, P.O. Maliha, Dist. Malda, PIN 732102
Supply, delivery and installation of 63 KVA servo motor operated copper wound line voltage corrector at Jotgopal kagmari Distribution Zone within Northern Sector of Malda Arsenic Area water supply scheme in the District of Malda
2022_PHED_395533_6
WBPHED/EE/MLMD/NIeT_08 of 2022-2023
Open Tender
Electrical Work/ Equipment
Item Rate
45 days
Doulatpur PHE Complex, P.O. Maliha, Dist. Malda
Please refer Tender documents.
4 documents required · 4 mandatory
₹17,011
Yes
13 Jun 2025
25 Aug 2022
7 Sept 2022
25 Aug 2022
5 Sept 2022
25 Aug 2022
Amount
Supply & delivery at site 63 KVA 3-Phase oil cooled type servo motor operated copper wound line voltage conforming to IS-9815 (Pt-1)-1994 suitable for unbalanced I/P Voltage with following specification including first filling oil as per IS-335 where applicable. [Make : Digitek / Fiji/ AE / Electortecnica / Power Grip/Other approved make.]
A) Input Voltage : 3 phase Main supply may or may not be balanced with respect to phase to phase 200V-500V and phase to neutral 115V-290V.
B) Output Voltage : 3 phase balanced output phase to phase 400V or 415V± 1% phase to neutral 230 V or 240 V± 1% (Provision should be made to adjust the variation of output voltage per phase by a variable pot well within ± 5% of output)
C) Line Regulation: Output voltage should remain well within ± 1% of set voltage (from Min. to Max. i.e. either 400V or 415V supply variation).
D) Local Regulation : Output voltage should remain neutral well ± 1% of set voltage be (From no load to full load) i.e. either 400V or 415 Volts.
E) Correction Speed: Better than 35 Voltes - Second.
F Efficiency : Better than 95% on full load.
G) Cut off limit: (Minimum & Maximum) by limit switch with Audio and Visual.
I) Lamp indication: For input and output should be provided (3 Lamp per side)
J) M.C.C.B. Protection: For input side..
K) Load Protection: TPN MCCB on each output phase should be available.
L) Output over shoot: Beyond 210V. 255 Volt/phase incase of "MANUAL MODE" and voltage Protection "AUTO MODE' operation.
M) VISUAL indication for under voltage over voltage of output.
N) Manual Mode: Up & Down correction with O/P Voltage over shoot protection beyond 210V-255 volts. Per phase..
O) Nature of cooling: Oil cooled system. (Manufacturing Test Certificate should be provided at the time of delivery.)
P) Electric Current Over Load Protection
Q) Circuit for delay output
R) Input High Voltage Cut-off above 500 volt.
S) Mode of operation:-Auto manual with a provision to restore the normal working of the unit '' standby operation'' should be available incase of any Electronic Failure auto-mode
T) Auto Mode:- Normal & Standby
Supply and delivery of following materials at site
200 A, 415 V, 4 pole off load changeover switch
200 A, 415 V TPN Rewirable type Mainswitch
1.1 KV grade 415 V, 50 Sqmm, 4 core AL. Ar. Cable
200 A Bus-Bar Chamber having 4 nos. Al. Bus-Bar
Making brick built foundation with supplying of all required materials suitable for the above voltage stabilizer by (4:1) cement mortar including holding down foundation bolts and 12mm thick plaster with neat cement finish as per direction of EIC.
Installation of the above voltage stabilizer of item No.1 on the foundation including all connection complete as per direction.
fitting, fixing of change over switch, Busbar Chamber and main switch as mentioned in item no. 2. 01, 2.02 and 2.04 on the iron angle frame of suitable size fixed at suitable location on wall by Supplying all necessary fixing materials all complete as per direction of EIC
Laying of cable as in item no. 2.03 on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting as directed by EIC.as per site requirement
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of supplied cable as in item no. 2. (c as per direction of EIC.
Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt.long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil byusing salt & charcoal or coke for plate electrode
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Testing Commisioning the whole installation upto entire satisfaction of E.I.C
MAKE AS PER DEPARTMENTAL APPROVED VENDOR LIST CIRCULATED VIDE MEMO NO.PHE/IV/2277/W-181/19 DATED- 25/09/2019
Add GST @ 12%
Add Cess @ 1%
ANIMA ENTERPRISE
DEVI ENTERPRISE
DAS CONSTRUCTION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .