Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC | ₹13.9 L | L1 | Accepted-AOC tcr |
| 2 | L2₹15.0 L+₹1.1 L (8.11%)Rejected-Finance UKHRA BARDHAMAN BARDHAMAN 713363 WEST BENGAL INDIA | BARDHAMAN | BARDHAMAN | WEST BENGAL | 713363 | ₹15.0 L+₹1.1 L (8.11%) | L2 | Rejected-Finance TCR |
| Sl No | Description | Qty | Unit | Karmakar Engineering Workshop L2 | MUKHERJEE AND CHATTERJEE CONSTRUCTION L1 |
|---|---|---|---|---|---|
| 1.00Discription of items | |||||
| 2.00 | Panel No. P9(A)& P9(B),-28L/-5D to-28L/9D, -5D/-23L to 9D/-23L in RVIIC seam Debris cleaning and Dismantling of 6 flange fitted M.S. pipe range installed from-131/-90 to-13L/9D, -131/-10 to -171/-10, -13L/6D to -17L/6D, -9D/17L to -250/-171, 1092mtr. (182 Nos.) long and 13L/2D to -6L/ZD, 180mtr(30 Nos) | 1 | ls | 1,40,000 ₹1,40,000 | 1,35,000 ₹1,35,000 Lowest |
| 3.00 | Manual transportation of 1272mtr.(212 Nos.) flange fitted 6 MS.pipes from -13L/-9D to-13L/9D, -13L/-1D to-17L/-10, -131/6D to -17L/6D, -9D/17L to -250/-171, -13L/20 to 6L/2D and stocking the same at mention location. | 1 | ls | 4,15,750 ₹4,15,750 | 3,82,000 ₹3,82,000 Lowest |
| 4.00 | Manual Transportation and Laying of flange fitted 6" Pipe M.S. From,-28L/-SD to-281/90, -50/-23L to 90/-23L 720mtr(120nos.) in Panel no.P9(A)&P9(B). | 1 | ls | 1,15,575 ₹1,15,575 Lowest | 1,15,600 ₹1,15,600 |
| 5.00 | Installation, joining of 6" M.S.pipe line from-281/-5D to-28L/9D, -5D/-23L to 9D/-231, 720mtr(120nos.) including bends and 2 pipe in Panel no.P9(A)&P9(B). for supplying water to CM package | 1 | ls | 87,000 ₹87,000 | 85,650 ₹85,650 Lowest |
| 6.00 | Complete testing and trial run of installed pipe range for any leakages and adjusting the pipe range for leak proof pipe range. | 1 | ls | 95,950 ₹95,950 | 87,500 ₹87,500 Lowest |
| 7.00 | Common Pipe line for panel no. P9(A)& P9(B), -8L/-5D to-28L/-5D in RVIIC Manual Transportation and Laying of flange fitted 6" Pipe M.S. from -5D/-8L to-5D/-28L, 520mtr(86nos.) in common Panel of P9(A)&P9(8). | 1 | ls | 1,50,200 ₹1,50,200 | 1,38,385 ₹1,38,385 Lowest |
| 8.00 | Installation, joining of 6" M.S.pipe line from -5D/-BL to-5D/-28L 520mtr(86nos.) in common Panel of P9(A)&P9(8) including bends and Z pipe in Panel no.P9(A)&P9(B) for supplying water to CM package | 1 | ls | 75,585 ₹75,585 | 65,958.64 ₹65,958.64 Lowest |
| 9.00 | Complete testing and trial run of installed pipe range for any leakages and adjusting the pipe range for leak proof pipe range. | 1 | ls | 62,950 ₹62,950 | 54,183.36 ₹54,183.36 Lowest |
| 10.00 | Cost for M.S. Nut Bolt 5/8"x 3" as per applicable IS | 50 | kg | 120 ₹6,000 | 95 ₹4,750 Lowest |
Tender Value
₹13.9 L
EMD Value
₹17,400
Closing Date
27 Dec 2025, 9:00 amClosed
General Manager Bankola Area
Office of The General Manager Bankola Area, PIN-713363
Installation and Commissioning of M.S.Pipe range in Panel no. P9(A)and P9(B) of RVIIC seam for LHCM 4 package in CM project at Nakrakonda Kumardihi B Colliery under Bankola area
2025_ECL_349475_1
ECL/GM/BA/E TENDER/25-26/ENM/227 Dt 17.12.2025
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Nakrakonda Kumardihi B Colliery
Please refer Tender documents.
4 documents required · 4 mandatory
₹17,400
16 Jul 2026
17 Dec 2025
29 Dec 2025
17 Dec 2025
27 Dec 2025
17 Dec 2025
17 Dec 2025 - 20 Dec 2025
Amount
Discription of items
Panel No. P9(A)& P9(B),-28L/-5D to-28L/9D, -5D/-23L to 9D/-23L in RVIIC seam Debris cleaning and Dismantling of 6 flange fitted M.S. pipe range installed from-131/-90 to-13L/9D, -131/-10 to -171/-10, -13L/6D to -17L/6D, -9D/17L to -250/-171, 1092mtr. (182 Nos.) long and 13L/2D to -6L/ZD, 180mtr(30 Nos)
Manual transportation of 1272mtr.(212 Nos.) flange fitted 6 MS.pipes from -13L/-9D to-13L/9D, -13L/-1D to-17L/-10, -131/6D to -17L/6D, -9D/17L to -250/-171, -13L/20 to 6L/2D and stocking the same at mention location.
Manual Transportation and Laying of flange fitted 6" Pipe M.S. From,-28L/-SD to-281/90, -50/-23L to 90/-23L 720mtr(120nos.) in Panel no.P9(A)&P9(B).
Installation, joining of 6" M.S.pipe line from-281/-5D to-28L/9D, -5D/-23L to 9D/-231, 720mtr(120nos.) including bends and 2 pipe in Panel no.P9(A)&P9(B). for supplying water to CM package
Complete testing and trial run of installed pipe range for any leakages and adjusting the pipe range for leak proof pipe range.
Common Pipe line for panel no. P9(A)& P9(B), -8L/-5D to-28L/-5D in RVIIC Manual Transportation and Laying of flange fitted 6" Pipe M.S. from -5D/-8L to-5D/-28L, 520mtr(86nos.) in common Panel of P9(A)&P9(8).
Installation, joining of 6" M.S.pipe line from -5D/-BL to-5D/-28L 520mtr(86nos.) in common Panel of P9(A)&P9(8) including bends and Z pipe in Panel no.P9(A)&P9(B) for supplying water to CM package
Complete testing and trial run of installed pipe range for any leakages and adjusting the pipe range for leak proof pipe range.
Cost for M.S. Nut Bolt 5/8"x 3" as per applicable IS
Cost for M.S. Nut Bolt 5/8"x 2" as per applicable IS
Cost for 6" Cast Iron Body Rising Spindle Sluice Valve Body Pressure 950psi, Valve Seat pressure 750 psi
Total impact of GST for the purpose of CTC
Karmakar Engineering Workshop (BID ID -1205472)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.86 MB
Tendernotice_2.pdf
PDF • 1.25 MB
BOQ_362221.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .