Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical 1 14 1 14 RAJNIKHAND ANSHIK RAJNI KHAND SHARDA NAGAR LUCKNOW UTTAR PRADESH 226002 | LUCKNOW | UTTAR PRADESH | 226002 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical 5D 95 VRINDAVAN YOJNA RAEBARELI ROAD LUCKNOW UP 226 029 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226029 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹1.5 Cr
EMD Value
₹2.9 L
Closing Date
19 Mar 2026, 6:00 pmClosed
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, LucknowCantt, Lucknow-226002
SPL REPAIR TO FENCING AND BOUNDRY WALL OF DILKUSHA QUARTERS FOR OFFICERS AND ALLIED WORKS UNDER GE (WEST) LUCKNOW.
2026_MES_753443_1
CWE/LKO/W/T-129 OF 2025-26
Open Tender
Civil Works
Item Rate
120 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE WEST LUCKNOW
₹2.9 L
Yes
9 Sept 2026
19 Feb 2026
26 Mar 2026
19 Feb 2026
19 Mar 2026
12 Mar 2026
19 Feb 2026 - 12 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling posts or struts(wood ,steel or RCC) of any section including taking out embedded portion of concrete, brick work of any and making good disturbed ground all as specified and directed. | 328 | Rm | - | - |
| 2 | Dismantling existing barbed wire/plain wire/ chain link fencing any type from RCC/Steel/Wdn posts complete etc all as specified and as directed. | 1,000 | Sqm | - | - |
| 3 | M & L for Modular brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 Incl Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles. all as specified and directed. | 20 | Cum | - | - |
| 4 | Excavation in trenches n.exc 1.5 m in depth for foundation n.exc. 10 sqm on plan and n.exc 1.5 mtr in depth and getting out complete in soft/loose soil complete all as specified and directed. | 207 | Cum | - | - |
| 5 | M & L for cement concrete type D2 1:4:8 (40mm graded aggregates) in foundation filling and mass concrete complete all as specified and directed. | 29 | Cum | - | - |
| 6 | S & F OF PRECAST I SHAPED COLUMN OF SIZE 2400MM X 200MM X 200MM PREPAINTED AND COLUR IS AS PER ENGINEER-IN-CHARGE,HAVING FLANGE THICKNESS OF 60 MM AND WEB THICKNESS 80 MM WILL PLACE ON PCC BASE SIZE 750MM X 750MM X 100MM ,GROUTED INTO PIT SIZE 600MM X 600MM X 900MM. USING SHUTTERING WITH CONCRETE RATIO 1:3:6, HAVING A CAP FIXED AT TOP OF THE COLUMN, HAVING 4 MM THICK HIGH TENSILE TENDOM STEEL 10 NOS IN EACH COLUMN WHICH IS MADE OF HIGH PERFORMANCE SELF COMPACTING CONCRETE (SSC) OF M40 GRADE, CURED UNDER CONTROLLED FACTORY CONDITIONS, ALL MANUFACTURING PROCESS MUST COMPLY WITH INDIAN STANDARDS. THE CURING PROCESS MUST BE MAINTAINED USING RO WATER AND CHILLER PLANTS FOR QUALITY ASSURANCE. THE FORMWORK USED FOR CASTING SHOULD BE MADE OF AUTOMOBILE-GRADE, WATER-TIGHT STEEL, ENABLING THE PRODUCTION OF HIGHLY ACCURATE AND CONSISTENT COMPONENTS. CONCRETE MIX DESIGN OF IS:9103 WITH WEIGHT OF EACH COLUMN AT LEAST 185 KG (TOLERANCE LIMIT 1.5%) , COMPLETE ALL AS SPECIFIED AND DIRECTED AS PER ENGINEER-IN-CHARGE. | 344 | Each | - | - |
| 7 | S&F OF PRECAST PANEL HAVE OVAL SIZE HOLLOW DESIGN PREPAINTED AND COLOUR AND DESIGN AS PER ENGINEER-INCHARGE OF SIZE 3000MM X 750 MM X 75MM HAVING 8 MM THICK STEEL BARS IN PANEL ,WHICH IS MADE OF HIGH PERFORMANCE SELF COMPACTING CONCRETE (SSC) OF M40, CURED UNDER CONTROLLED FACTORY CONDITIONS. ALL MANUFACTURING PROCESS MUST COMPLY WITH INDAIN STANDARDS. THE CURING PROCESS MUST BE MAINTAINED USING RO WATER AND CHILLER PLANTS FOR QUALITY ASSURANCE. THE FORMWORK USED FOR CASTING SHOULD BE MADE AUTOMOBILE GRADE WATER TIGHT STEEL ENABLING THE PRODUCTION OF HIGHLY ACCURATE AND CONSISTENT COMPONENTS. CONCRETE MIX DESIGN OF IS:9103 WITH WEIGHT OF EACH PANEL AT LEAST 270 KG (DEPENDS ON DESIGN), COMPLETE ALL AS SPECIFIED AND DIRECTED AS PER ENGINEER-IN-CHARGE. | 570 | Each | - | - |
| 8 | M & L plain cement concrete (1:2:4), type B1 using 20mm graded stone aggregate as in column footing including necessary form work complete all as specified and directed. | 130 | Cum | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
cancelled_1.pdf
pdf • 0.12 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.11 MB
TenderWT129.pdf
Tender Documents • 1.53 MB
BOQ_843908.xls
BOQ • 0.28 MB
129.pdf
PDF • 0.32 MB
CorrigendumOtherT129.pdf
PDF • 0.31 MB
Date10.pdf
PDF • 0.15 MB
DrgBoundarywall.pdf
PDF • 1.85 MB
Criticaldate_09.pdf
PDF • 0.12 MB
Criticaldate8.pdf
PDF • 0.12 MB
Criticaldate7.pdf
PDF • 0.12 MB
Criticaldate6.pdf
PDF • 0.12 MB
Criticaldate5.pdf
PDF • 0.12 MB
Criticaldate4.pdf
PDF • 0.12 MB
Criticaldate3.pdf
PDF • 0.12 MB
Criticaldate2.pdf
PDF • 0.15 MB
Criticaldate.pdf
PDF • 0.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .