EE(A-M) Chinsurah (A-M) Division
EE(A-M) Chinsurah (A-M) Division
Annual maintenance and rewiring of internal wiring at pump house / kiosk box for different RLI Schemes Under Khanakul (A-M) Sub- Division under Chinsurah (A-M) Division under Non-Plan Programme in the District of Hooghly
2026_WRDD_1001763_11
WBWRDD/EEAM/CNS/NP /eNIT-20 of 2025-26
Open Tender
ELECTRICAL WORKS M/R
365 days
Hooghly
Please refer Tender documents.
4 documents required · 4 mandatory
₹8,800
4 Mar 2026
9 Feb 2026
23 Feb 2026
9 Feb 2026
20 Feb 2026
9 Feb 2026
(b) Supplying,fitting & fixing of M.S. angle (Size: 50mmx50mmx6mm) incuding gas cutting etc.
Supplying,fitting & fixing 350mmx250mmx25mm Size wooden plank on wall (for fitting & fixingof electrical eqipments as necessary on the plank )
Supply, Fitting & fixing of DPIC main switch 15/16A 250 Volts (Havells) on flat iron frame on wall including mending good the damage for light circuit of pump house
Supplying and fixing 240/415 V 63A MCB isolator on din rail on existing DBs and necessary connection. Brand Havells
Supplying & fixing bulk head light fitting 9Havells make) with die cast aluminium housing & frosted glass on wall/ceiling including S&F 8 watt CFL/ 100 watt GL lamp complete set
Wiring from 15/16A DPIC main switch to Busbar box in 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) of 2 x 36/0.3(2.5 Sq. mm) + 1 x 22/0.3(1.5 Sq. mm) in PVC casing capping (Precision make) including necessary PVC clips,fittings etc incl supply of wire.
Wiring from 15/16A DPIC main switch to BDB in 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 2X 36/0.3(2.5 Sq. mm) + 1 X 22/0.3(1.5 Sq. mm) in PVC casing capping (Precision make) including necessary PVC clips,fittings etc.incl supply of wire
Distribution wiring in 1.1KV grade 2 x 22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) in suitable size PVC Casing- caping with 1X22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire for ECC, including necessary PVC clips,fittings etc. to light/fan/calling bell point with piano key type switch of (Anchore make) fixed on sheet steel fabricated switch board with perspex/ bakelite top cover on wall including necessary connections and making earthing attachments and mending good damages to the building works incl. supply of wire.[PVC casing capping and switch board both on surface] average run 5 meter
Distribution wiring in 1.1KV grade 2X22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 1X22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire for ECC, including necessary PVC clips,fittings etc. to 5amps 3 pin flush type plug socket with piano key type switch of (Anchore make) fixed on sheet steel fabricated switch board with perspex/ bakelite top cover on wall including necessary connections and making earthing attachments and mending good damages to the building works.[PVC casing capping and switch board botyh on surface] average run 1.5 meter
Fitting & fixing of 200A 500 V iron clad/ sheet steel TP/ TPN main switch on iron legs on wall
Fitting & fixing of 63A 500 V iron clad/ sheet steel TP/ TPN main switch/isolators on iron legs on wall
Fitting & fixing of only 63A/100A/200A 500V iron clad M.S. sheet metal busbar chamber on angle iron frame on wall for 4 bars 63Amps
Fitting & fixing of Star - Delta starter (for 20 HP motor contol) on angle iron frame on wall
Fitting & fixing of Volt meter and Ammeter with necessary screws and other fixing materials including making holes where necessary and making connections
Suppling & fitting & fixing of danger Board (mannual) 4"x6" in two distinguishing position in the door of pump house (outside) and at the palce of panel board.
Earthing with 50 mm (2") dia Galvanized iron pipe(TATA MAKE) 3.64 mm thick X 3.04 mtr.(10ft) long and 1X4 SWG G.I.(Hot Dip) Wire (4 mtr. Long ) 13 mm (1/2") dia X80 mm (3") long G.I. Bolts, double nuts and double washer including S&F 15 mm dia G.I. Pipe protection (1 mtr) long to be fitted with bitumen partly under the ground level and partly above the ground level driven to an average depth of 3.56 mtr. (12") below the ground level and restoring the surface duly rammed for Soft/Morrum soil by TATA-Medium G.I. Pipe
Supplying and fixing earth bar of galvanized M.S. Flat 25 mm × 6 mm on wall having clearance of 6 mm. from wall including providing drilloed holes (on busbar) about 3 cm. apart complete with G.I. bolts, nuts, washers etc. as required for tapping.
Connecting the equipments to earth busbar including supplying and fixing G.I. Wire No. 8 SWG on wall/floor with stapples burried inside floor/wall as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and mending good all the damages.
Supplying and Drawing with 1.1 KV , PVC flexible FR cable copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall /Kiosk Box including making necessary connection to the prefixed device with all necessary accessories like saddle, screw,clips,gland, socket etc. conforming to IEE regulation and as per direction of EIC. Brand: Gloster/Havells/Finolex) i) 4C x 25 sqmm copper cable conforming to IS 694 [100/200 A TPN switch to Bus-bar[.
ii) 3C x 16 sqmm copper cable conforming to IS 694 [ Busbar to 63A TP Main switch]
iii) 3C x 16 sqmm copper cable conforming to IS 694 [ 63A TP Main switch to Motor Starter]
iv) 2 x 3C x 10 sqmm copper cable conforming to IS 694 in 32 mm GI conduit (ISI Medium quality) [Star/Delta Motor Starter to Motor]
Placing and positioning the Centrifugal pump motor set on the pump base/pump house floor, alligning properly with necessary packing and fixing the set with holding down nuts and washer including cutting holes of requisite size in the floor / base, grouting the bolts and mending good all damages- complete as per direction of the Engineer-in-Charge.
Insulation testing of internl wiring of Pump House/Kiosk box including wiring of motors and other ancilary equipments by means of Megger.
Reparing of Main Switch for 63 Amps/32 Amps (Rewireable Type) by taking out and fitting fixing Fuse Grip (63 Amps/32Amps) (to be supplied departmently) on existing iron legs on wall as per direction of the Engineer-in -Charge.
Reparing of Main Switch for 63 Amps/32 Amps (Rewireable Type) by taking out and fitting fixing Action Bar with U-Clip setting (to be supplied departmently) on existing iron legs on wall with testing as per direction of the Engineer-in -Charge.
Reparing of Main Switch for 63 Amps/32 Amps (Rewireable Type) by taking out and fitting fixing End Shield Block with connecting wire (to be supplied departmently) on existing iron legs on wall as per direction of the Engineer-in -Charge.
Repairing of Manually Operated Heavy Duty Star/ Delta oil Immersed Starters by taking out and fitting fixing Overload Coil (to be supplied departmently) with testing on exgisting angle iron frame on wall as per direction of the Engineer-in-Charge (for 100Amps/63Amps) .
Repairing of Manually Operated Heavy Duty Star/ Delta oil Immersed Starters by taking out and fitting fixing No Volt Coil (to be supplied departmently) with testing on existing angle iron frame on wall as per direction of the Engineer-in-Charge (for 100Amps/63Amps) .
Repairing of Manually Operated Heavy Duty Star/ Delta oil Immersed Starters by taking out and fitting fixing Set of Contact (to be supplied departmently) with testing on existing angle iron frame on wall as per direction of the Engineer-in-Charge (for 100Amps/63Amps) .
Heat varnishing with best quality ( Johnson & Johnson/Dr. Beck/ giliander) class E insulating varnish of required quantity for 3 course& unifoheating at 80' C for 48 hrs. with all cost of materials , labour as per direction of E.I.C. a) Insulating varnish 1 lit for 20 HP induction motor.
Motor bering change (All type of elrctro motor.17.5/20 HP3ph. 400/415 Volt).
Motor Terminal plate change (All type of elrctro motor.17.5/20 HP. 400/420 Volt).
GST @ 18% on every item
Labour welfare Cess@1%on every item
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.12 MB
Tendernotice_2.pdf
PDF • 0.51 MB
BOQ_2454897.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid