| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 CrAccepted-AOC MUMBAI 400074 ACHARYA COOMERCIAL SHOPPING CENTRE 119 1ST FLOOR ACHARYA COMMERCIAL AND SHOPPING CENTRE DR C G ROAD NEAR BASANT CINEMA CHEMBUR MUMBAI 400074 DR C G ROAD | MUMBAI SUBURBAN | MAHARASHTRA | 400074 | ₹3.4 Cr | L1 | Accepted-AOC Being L1 |
Tender Value
₹3.7 Cr
EMD Value
₹7.3 L
Closing Date
1 Mar 2024, 3:00 pmClosed
CE, CED
CED,BARC,Trombay, Mumbai
Construction of 03 Nos. of L and CM Site offices including Civil and PH Works at various locations in BARC, Trombay, Mumbai.
2024_BARC_790914_1
BARC/CED/ET/78/2023-2024 Dated 16.01.2024
Open Tender
Civil Works
Item Rate
365 days
BARC, Trombay, Mumbai
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹7.3 L
Yes
CED,BARC,Trombay, Mumbai
27 Aug 2024
18 Jan 2024
7 Mar 2024
19 Jan 2024
1 Mar 2024
15 Feb 2024
19 Jan 2024 - 31 Jan 2024
6 Feb 2024
Amount
Supplying and injecting with approved quality chemical emulsion at the rates and concentrations as per IS 6313-2001 Part II for pre-constructional anti-termite treatment and creating a chemical barrier under and alround the masonry pits, masonry foundations, wall trenches, plinth filling, junctions of wall and floor, expansion joints, surfaces of RCC works for a depth of min. 500 mm from the finished ground level, surrounding of pipes, conduits etc., walls retaining soil above floor level, apron and drain along the perimeter of the building including all bye works complete as per specification / IS 6313:2001 or latest revision and direction of Engineer In charge (only ground floor plinth area of the building will be measured for the payment in the following three stages. i) 20% after completion of the foundations ii) 50% after completion of the ground floor flooring iii) 30% after completion of all treatment works including ground floor doors & windows. Work to be executed by approved agency and specified guarantee for 10 (ten) years shall be furnished by the contractor.
Providing and laying in position cement concrete of 1:3:6 (1 cement, 3 crushed sand, 6 graded stone aggregate of maximum size 20 mm) including consolidation, finishing, curing etc. complete as per specifications and drawings but excluding the cost of Form work shuttering, centering Complete at all levels
Providing and laying in position Reinforced Cement Concrete (RCC) of grade M-30 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticiser or super plasticiser) if required, including weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. complete but excluding the cost of centering, shuttering and reinforcement complete as per specifications up to Plinth Level.
Providing and laying in position Reinforced Cement Concrete (RCC) of grade M-30 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticiser or super plasticiser) if required, including weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. complete but excluding the cost of centering, shuttering and reinforcement complete as per specifications in super structure up to 20.00 metre height
Extra over for supplying RCC Using Ready Mix Concrete from outside project area including transporting and pumping from approved batching plants .
Providing Reinforcement Steel for reinforced cement concrete at all levels including supplying, preparation of bar bending schedules, cutting, bending, transporting, fixing, tieing in position with PVC coated G.I binding wire, all labour charges, cost of cover blocks in specified grade of concrete etc. complete as per specifications and drawings. Steel to be supplied by the contractor
"Using TMT bars of specified grades all dia. bars. TMT bars to be supplied by the contractor manufactured confirming to IS 1786. All test reports to be provided along with the supply of the materials."
Using Welded wire mesh of 50mm x 50mm x 5 mm thick as reinforcement as directed by the Engineer in charge.
Providing Structural steel work in M.S Plain Plates and chequrred Plates for Embedded Parts, Trench Covers, Connection plates etc. including cutting, hoisting, fixing in position and applying a priming coat of approved zinc chromate steel primer etc. including cost of structural steel Plates, welding all labour charges etc. complete as per drawings and specifications. Notes : '(1) Welding weights, connections, bolts and nuts, anchor bolts shall not be measured for payment, but the cost of which shall be deemed to have been included in the rate. '(2) All holes will be made by drilling only. Gas cutting of holes will not be permitted. (3) Edges of plates shall be grinded to uniform smooth finish. '(4) Full length welding shall be carried out as directed by the EIC. Note : Tentative/suggested make for the guidance of the bidder (s) : M/s. ADOR, ESAB, Indian Oxygen and D&H SECHERON or approved equivalent make - Welding Electrodes.
Using materials manufactured confirming to IS 2062. All test reports to be provided along with the supply of the materials.
Providing Structural steel work using angles, channels, joists and other sections, welded and / or bolted in built up sections for trusses, structural steel floors, frame works, monorails and other structures including supplying, cutting, welding, fabricating, hoisting, fixing in position, applying a priming coat of approved steel primer etc. complete all as per specifications, drawings and as directed by the Engineer in charge. Notes : '(1) Welding weights, connections, bolts and nuts, anchor bolts shall not be measured for payment, but the cost of which shall be deemed to have been included in the rate. '(2) All holes will be made by drilling only. Gas cutting of holes will not be permitted. (3) Edges of plates shall be grinded to uniform smooth finish. '(4) Full length welding shall be carried out as directed by the EIC. Note : Tentative/suggested make for the guidance of the bidder (s) : M/s. ADOR, ESAB, Indian Oxygen and D&H SECHERON or approved equivalent make - Welding Electrodes.
Up to and including 300 mm Joists, 350 mm channels, and below sections Using materials manufactured confirming to IS 2062. All test reports to be provided along with the supply of the materials.
Above 300 mm Joists, 350 mm channels, sections using materials manufactured confirming to IS:2062. All test reports to be provided along with the supply of the materials
Providing, supplying, cutting, welding, fabricating, hoisting and fixing in position structural steel members like trusses, purlins, posts etc. using MS hollow / circular / square / rectangular tubular sections including applying a coat of Zinc chromate primer of approved make all as per specifications, drawings and as directed by the Engineer in charge. Notes : '(1) Welding weights, connections, bolts and nuts, anchor bolts shall not be measured for payment, but the cost of which shall be deemed to have been included in the rate. '(2) All holes will be made by drilling only. Gas cutting of holes will not be permitted. (3) Edges of plates shall be grinded to uniform smooth finish. '(4) Full length welding shall be carried out as directed by the EIC. Note : Tentative/suggested make for the guidance of the bidder (s) : M/s. ADOR, ESAB, Indian Oxygen and D&H SECHERON or approved equivalent make - Welding Electrodes.
Providing and fixing hand rail using 304 grade Stainless Steel pipes of approved size and make and quality by welding, mirror / matt polishing, fixing at site etc. for balcony railing & staircases railing including special sections as per drawings, specifications. complete as directed by the Engineer-in-charge. Notes : '(1) Welding weights, connections, bolts and nuts, anchor bolts shall not be measured for payment, but the cost of which shall be deemed to have been included in the rate. '(2) All holes will be made by drilling only. Gas cutting of holes will not be permitted. (3) Edges of plates shall be grinded to uniform smooth finish. '(4) Full length welding shall be carried out as directed by the EIC. Note : Tentative/suggested make for the guidance of the bidder (s) : M/s. ADOR, ESAB, Indian Oxygen and D&H SECHERON or approved equivalent make - Welding Electrodes.
Providing and fixing Anchors M-08 dia or approved equivalent meeting all the technical specification as per relevant codes and standards including drilling in concrete as per requirement for fixing EPs or other structures all as specified by the manufacturer complete all as per specifications and drawings. Note : Tentative/suggested make for the guidance of the bidder (s) : M/s. Hilti (Anchors HST STUD Type) or approved equivalent make
Providing and fixing at all levels MS bolts including nuts and washers of approved size, quality and make as per requirements and as per specifications, drawings complete all as directed at site by the Engineer in charge
Providing, centering, shuttering Form work using PVC film faced plywood to get a neat form finish surface for all types of structures including necessary strutting, proping, staging, supports etc. and de-shuttering the same after the specified time all as per drawings, specifications and as directed by the Engineer-in-charge.
For Sub Structure
For Super Structure
Providing and constructing Half brick masonry using Flyash/ Flyash Lime bricks with minimum 70 kg / Sq.cm strength of approved make and size in partition walls in C.M 1:4 (using crushed sand) including scaffolding, raking out joints, curing etc. complete and with stiffeners of RCC 1:2:4 (105 X 75 mm size) at every 900 mm height including form work curing etc. complete as per specifications but excluding reinforcement in Super Structure up to Floor - II level. (Note : Reinforcement will be paid under relevant item)
Providing and constructing Brickwork in cement mortar 1:4 using crushed sand with Flyash / Flyash Lime bricks with minimum 70 kg / Sq. cm strength of approved make and size in Sub structure including, scaffolding, raking out joints, curing, cleaning complete all as per specifications and drawings.
Providing and constructing Random Rubble masonry using approved Rubble stone in super structure (above plinth) in C.M 1:6 (using crushed sand) including raking out joints or simultaneous flush pointing above ground level / plinth level and up to and including 20 m height including scaffolding, curing etc. complete as per drawings and specifications.
Supplying , cutting to shape and fixing specified diameter PVC pipes as per IS 4985 in RR Masonry/ RCC walls for weep holes complete all as per drawings and as specified at site.
110 mm dia UPVC Pipes
Providing filter media of size 300 mm x 300 mm at external face of Drains at Weep hole locations using stone aggregates of size 63 to 45 mm during refilling of earth around the drains all as directed by Engineer in charge.
Labour charges for constructing Random Rubble masonry using Rubble Stone available at site in foundation and plinth in C.M 1:6 (using crushed sand) including cost of bond stones, raking out joints or simultaneous flush pointing below ground level / plinth level, curing etc. complete as per drawings and specifications.
Providing 15 mm thick plastering using Ready mix internal plastering compound of approved make for internal faces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning, scaffolding complete all as per specifications and as directed at site by the Engineer-in-charge
Providing 20 mm thick plastering using Ready mix external plastering compound of approved make for external faces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning scaffolding up to 10 metres height complete.all as per specifications including forming drip moulds wherever necessary and as directed by the Engineer-in-charge
Providing and fixing G.I. chicken mesh in the junctions of concrete & brick work / masonry or as directed by the Engineer in charge including cutting, fixing with nails in position before plastering complete all as directed by the Engineer-in-charge. (Note : Only area of the chicken mesh used alone will be measured)
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS 15622 of approved make. shade and colour of size ranging from 300 - 600 mm long and 300 mm - 600 mm wide and thickness not less than 6 mm as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (using crushed sand), setting the tiles in cement slurry and pointing the joints with matching colour Tile grout of approved make of matching shade including using PVC tile trim in the exposed corners, complete as per drawings, patterns and specifications complete as directed by the Engineer-in-charge.
Providing and fixing Glazed VITRIFIED floor tiles of approved make in different sizes conforming to IS 15622 in all colours and shades in Glossy or Matt or satin finish laid over a bed of minimum 20 mm thick bed of cement mortar 1:4 (using Crushed sand) and jointing with grey cement slurry including grouting with the joints with white cement based Tile Grout of approved make and matching shade complete as per patterns, drawings and specifications complete as directed by the Engineer-in-charge
Using Tiles of size 600 X 600 mm
Supplying, stacking and laying of 230 mm thick rubble soling stones as under floor base including packing with smaller stone and compacting, ramming including spreading and consolidation of blinding material, murrum etc. complete all as per specifications and as directed by the Engineer-in-charge
Murrum filling under floors of specified thickness in layers of not more than 150 mm thickness including supplying required materials and consolidation etc. complete (Murrum to be brought from out side campus of BARC)
Labour charges for murrum filling under floors of specified thick in layers of not exceeding 150 mm thickness including consolidation etc. complete (using murrum available at site)
Labour charges for murum filling under floors of specified thickness in layers of not exceeding 150 mm thickness including consolidation etc. complete (using murrum available at BARC campus with a lead of up to 4 Km)
Providing and fixing Minimum 15-17 mm thick gang saw cut mirror polished (pre-moulded and pre-polished) machine cut Granite of Jet Black colour for kitchen platforms, vanity counters, wash basin counters, door frames, window sills, facia and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (using crushed sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing the edges to give high gloss finish etc. complete at all levels
Extra for providing edge moulding to 15-17 mm thick Granite Slab counters, Vanitis etc. including machine polishing to edge to give high gloss finish et. Complete as per design approved by Engineer-in-charge.
Providing and fixing anodized aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / Z sections and other sections of approved make conforming to IS 733 and IS 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereever required including cleat angle, aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete as per drawings and and directions of Engineer-in-charge including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required filling the gaps using silicon grout sealent etc. (Note : Fittings, glazing and panelling shall be paid for separately) Notes : 1) The rates for aluminium is inclusive of all fasteners required for fabrication and fixing in the walls. 2) All joints shall be of mittered Joints. 3) A long M.S. rod threaded at both ends to be provided in all aluminium door shutters in Top & bottom Horizontal members internally connecting Vertical members and fixed with M.S washers & nuts. 4) Only Aluminium members alone shall be measured and paid for.
Anodised Aluminium sections (Minimum anodizing thickness of 15 micron)
Extra over for colour anodizing
Providing and fixing glazing in aluminium doors, window, ventilator shutters and partitions etc. with PVC / Neoprene gasket etc. complete as per the architectural drawings and directions of the Engineer-in-charge (Cost of snap beading shall be paid in basic item)
With clear float glass panes of 6.00 mm thickness
With tinted colour float glass panes of 6.00 mm thickness
Providing and fixing approved quality stain less steel body roller wheels of approved make for sliding shutters
Providing and fixing 40 / 42 mm thick Aluminium Flush Door Shutter consisting of 2 mm thick colour anodized Aluminium Sheets (15 micron), 37 mm wide Aluminium frame work inside filled with glass wool 50 mm thick compressed to 37 mm including all furniture fittings, 4 Nos SS Heavy duty hinges of size 125 mm with SS Screws, 6 lever mortise lock with handles, 1 No. 250 X 12 mm long Aluminium tower bolt including vision panel with glass as per drawings complete manufactured by approved manufacturer complete as per approved fabrication drawings as directed by the Engineer-in-charge.
Providing and fixing FRP door shutters flush door / panelled type with plain colour or wooden veneer finish of approved make, design & colour, made out of 1.5 mm thick FRP skin moulded over wooden frame work of 40 mm wide and required thickness wooden styles and minimum 100 mm wide lock rails and wooden blocks for door stoppers, tower bolts, baby latch, aldrop, handles etc. wherever required and core filled with Polyurethane Foam and fixing with 4 Nos 100 mm (ISI marked) stainless steel hinges with S.S. wood screws
30 mm thick panelled door type of approved colours including the cost of ISI marked 100 mm heavy quality stainless steel butt hinges with necessary screws.
Providing and fixing IS: 3564 marked aluminium die cast body tubular type universal hydraulic door closer of approved make with necessary accessories and screws etc. in wooden doors / steel doors with necessary bolts & nuts complete as per specifications and as directed by the Engineer-in-charge.
Providing and fixing aluminium hanging heavy quality floor door stopper ISI marked with twin rubber stoppers, anodised transparent or dyed to required. colour or shade with necessary screws etc. complete.
Providing and laying water proofing treatment in sunken portions of WCs, bath rooms etc. by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) 1st layer of slurry of cement @ 0.488 kg / sq.m mixed with water proofing cement compound @ 0.253 kg per sq.m. including injecting cement slurry. This layer will be allowed to air cure for 4 hours. (b) 2nd layer of slurry of cement @ 0.242 kg / sq.m mixed with water proofing cement compound @ 0.126 kg / sq.m. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with cement slurry. Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (using crushed sand) admixed with proprietary water proofing compound conforming to relevant IS and approved by Engineer-in-charge including mixing fibre at the rate of 125 grams per 50 kg of cement in top layer of plaster and finally finishing the surface with trowel with neat cement slurry in bottom and all the sides of sunken portion. complete as directed by the Engineer-in-charge. The treatment to be tested for water tightness before filling the sunken areas. Note : Tentative/suggested make for the guidance of the bidder (s) : M/s. RECRON 3S' fibre or approved equivalent make
Providing and applying wall painting two coats on new work with premium plastic emulsion paint of approved brand to give an even shade, including a coat of approved cement primer, including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge
Providing and Painting two coats of synthetic enamel paint on steel surfaces of approved brand and manufacture to give an even shade over a primer coat including preparation of the surfaces, scaffolding complete as per specifications and as directed by the Engineer-in-charge.
Providing and fixing double tubular scaffolding system using H-frames with cup lock type on the exterior side upto seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S clamps and M.S staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and as approved by the Engineer -in - charge. The elevational area of the scaffolding shall be measured for payment purposes. The payment shall be made once irrespective of duration of scaffolding
Providing and painting walls with (TWO coats) of approved shade of high build protective , elastomeric water proof exterior grade paint of approved make of required shade, minimum dry film thickness of 250 microns achived in two or more coats / as per manufacturer's specifications including preparation of the surfaces by scrapping / wire brush, scaffolding complete. Primer coat will be with approved make with water in ratio of 1:2 and 2 coats of finishing coat without water all as directed by Engineer-in-charge.
Providing and applying white cement based wall putty of approved make over concrete or Plastered surface up to 3 mm thick to get uniform surface free from undulation including cleaning complete all as directed by the Engineer-in-charge
Dismantling plain cement concrete manually / by mechanical means carefully without damaging adjacent structures including disposal of debris within 200 m lead as per direction of Engineer-in-charge
Dismantling of RCC works carefully manually without damaging adjacent structures excluding cutting of reinforcement including stacking of steel reinforcement bars and disposal of unserviceable materials within 200 m lead as per direction of Engineer-in-charge
Dismantling brick work in Cement mortar carefully without damaging adjacent structures including stacking of materials and disposal of unserviceable materials within 100 m lead as per direction of Engineer-in-charge
Demolishing Stone rubble masonry (In cement mortar) manually / by mechanical means carefully without damaging adjacent structures including stacking of serviceable materials and disposal of unserviceable materials within 100 m lead as per direction of Engineer-in-charge
Dismantling steel work in single sections including dismantling and stacking within 100 m lead In R.S Joists, Angles etc.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismantling and stacking within 100 m lead
Demolishing dry stone pitching in floors, drains etc. including stacking serviceable materials and disposal of unserviceable materials within 200 m lead
Dismantling roofing including ridges, valleys and gutter etc. and stacking the material within 50 m lead
G.S Sheet / FRP Sheet / AC Sheet
Dismantling and stacking within 100 m lead fencing posts or struts including all earth work and dismantling of concrete etc.
"T" or "L" iron or pipe
R.C.C Post
Dismantling G.I pipes of all diameter external work including excavation and refilling trenches after taking out pipes manually / by mechanical means including stacking of pipes within 100 m lead as per direction of Engineer-in-charge
Lead charges for lead Exceeding 3 KM but not exceeding 4 KM, by mechanical transport including loading, unloading, stacking / levelling etc. Note: The rates in respect of this Item are applicable for NET Quantities arrived at after making deduction for voids @ 20% in respect of soil, 50% in respect of rock and 30% in respect of debris from corresponding TRUCK Measurement
Debris
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made with strong vibratory compaction and approved size, shape, design laid in required colour and pattern over and including 50 mm thick compacted bed of crushed sand, filling the joints with crushed sand etc. all complete as -per the direction of the Engineer-in-charge.
Providing and grouting the joints of rubble stone pitching with cement mortar 1:3 and pointing the surfaces as directed complete as directed by the Engineer-in-charge
Providing and fixing Stainless steel Barbed wires using SS 304 Grade over RCC post/ M.S angles placed at required distance, using Stainless steel 304 Grade including long "J" hook fixed while fixing over the cement concrete/MS post etc. complete as directed by the Engineer-in-charge. With Stainless steel 304 Line wire – Diameter : 2.50 +/- 0.05 mm, Tensile strength : 1450-1650N/Sq mm., Barb Wire diameter : 2 mm +/- 0.02 mm, Tensile Strength : 1450-1650N/Sq mm. ,Barbing Pitch : 100mm, No. of Ply : 1 Barb, Type : 4 point IOWA Style, Roll Length: 200m, Weight / Roll : 22.12Kgs (+/- 5%) grade barbed wire 12 swg ( 2.50mm 2 ply line wire & barbs with 2.50 mm thick wires. Complete as per IS 1278. Note : Payment to be made in weight for total length of barbed wire used only.
Providing, supplying and fixing wire fabric Chain link fencing made of G.I. wire of dia. 3.0 mm and 2mm PVC coated to achieve outer dia not less than 5 mm in required colour and shade and size of 50 mm x 50mm with posts of specified material and of standard design placed steel wire fabric fixed between the posts fitted and fixed with G.I. staples / G.I Bolts or tied to 6 mm bar nibs with G.I. binding wire complete all as per specifications and drawings and as directed at site.
Providing and fixing pre-coated Galvalume Roofing sheets of Mangalore Tile profile or approved equivalent profile of approved size, shape and pitch up to and including single length of 12.00 m. The sheet shall be fixed using self drilling / self tapping screws of size (5.5 X 55 mm) with EPDM seal including Supplying, fabricating, testing, transporting, handling and erecting at required positions and levels metal roofing including insulation etc. as per approved drawings and design complete as directed by the Engineer-in-charge including all consumables comprising of the following : Top Layer :- Colour coated galvalume tile profile in 0.50mm thickness having yield strength min. 245 MPa with RMP finish (Regular Modified Polyester). Second Layer :- GI Z Spacer in 2.00mm thickness with min. Zn 80 GSM & Yield Strength 245MPa. (Size: 50mm X 50mm X 50mm). Third Layer :- Rockwool insulation in 50mm thickness with 48Kg/m3 density. Bottom Layer :- Colour coated galvalume Steel in MxRib Profile. The feed material is manufactured out of nominal 0.50 mm total coated thickness (TCT), Hi-tensile steel with minimum 550 MPa yield strength, metallic hot dipped coated with Alu.+Zinc alloy mass coating of AZ 150(min. grams / sq. m. total on both sides) with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as directed by the Engineer-in-charge.
Supplying, fabricating, testing, transporting, handling and erecting of colour coated galvalume flashings / ridge matching above Mangalore Tile profile or approved equivalent profile of approved size, shape and pitch in 0.50mm thickness with AZ 150GSM & Yield Strength 550MPa. About Size: Upto 610mm girth
Providing, laying, jointing, fixing and testing heavy quality (ISI Marked C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples, reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cm hydraulic pressure with a minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing teflon tape, chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anti corrosive bitumastic paint, all as directed by the Engineer-in-charge. Pipes with ISI marked 'C' -Class heavy quality pipes of approved make.
15 mm dia GI pipe
20 mm dia GI pipe
25 mm dia GI pipe
40 mm dia GI pipe
Providing & fixing in position heavy pattern screw down gun metal gate valve with handles and wheels of approved make including testing for 10Kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours etc.as per specification and as directed by the Engineer-in-charge
Providing and fixing C.P brass bib cock of heavy quality of specified / approved make as per specifications and as directed by the Engineer-in-charge
15 mm dia bib cock of approved type and make .
Providing and fixing C.P Brass open stop cock of Heavy Quality of specified / approved make as per specifications and as directed by the Engineer-in-charge
15 mm n.b CP Brass open stop cock of approved make and type
Providing and fixing C.P brass concealed stop cock of Heavy Quality of specified / approved make as per specifications and as directed by the Engineer-in-charge
15 mm n.b CP brass concealed stop cock of approved make
Providing and fixing C.P brass Angle cock of heavy quality of specified / approved make, for wash basin inlet / flush cistern etc. as per specifications and as directed by the Engineer-in-charge
Providing and Fixing 15 mm CP brass Angle stop cock of approved make- quarter Turn
Providing and Fixing CP brass 100 mm dia shower rose with Shower arm of Specified make as per specifications and as directed by Engineer-in-charge complete
Providing and fixing 15 mm C.P brass 2 in 1 bib cock and Angle cock combination of Heavy Quality of approved make as per specifications and as directed by the Engineer-in-charge
Providing and fixing 15 mm C.P brass pillar cock of heavy Quality of approved make and specified type as per specifications and as directed by the Engineer-in-charge.
Providing and fixing heavy quality health faucet with 1.50 metres long flexible hose (hand shower) of approved make with wall brackets and type as per specifications and as directed by the Engineer-in-charge
Providing and fixing square mouth S.W. gully trap complete with CI grating brick masonry chamber with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.5 kg and frame to be not less than 2.70 kg as per standard design
150 x 100 mm size gully trap "P" type
Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 100 m lead and disposal of unserviceable materials
100 mm diameter
Providing and laying non pressure NP2 class RCC Hume pipes of approved make, with collars jointed with stiff mixture of cement mortar in the proportion of 1:2, laying to the levels, slopes and as per the drawings and specifications and as directed by the Engineer-in-charge including testing of joints etc. complete.
100 mm Dia RCC Hume pipe class Np2
150 mm Dia RCC Hume pipe class Np2
250 mm Dia RCC Hume pipe class Np2
Providing and construction of Inspection chambers of Internal size clear dimension of 900 x 600 mm in 230mm thick brick masonry with cement mortar 1:4 over a bed of 150 mm thick 1:4:8 cement concrete foundation, plastering with cement mortar 1:4 20 mm thick on inside, out side and all exposed surfaces finished with a floating coat of neat cement, brick corbelling at top to provide opening of 900 X 450 mm, embedding the frame and cover with CC 1:2:4 concrete, and fixing cast iron steps if necessary at 300mm intervals complete . Depth of chamber not exceeding 900 mm. (excavation, soling, cast iron cover and C.I steps will be paid separately under relevant item)
Extra depth over initial depth of 900 mm for chambers of 900 x 600 mm internal size including fixing cast iron steps (C.I steps shall be paid under relevant item)
Constructing brick masonry circular type manhole 1520 mm internal dia at bottom and 560mm Internal dia at top, in cement mortar 1:4, inside cement plaster 12 mm thick with cement mortar 1:3 finished with a floating coat of neat cement, foundation concrete 1:3:6 mix, and making necessary channel in cement concrete 1:2:4 finished with a floating coat of neat cement all complete as per standard design including fixing C.I manhole Cover of specified weight in Concrete 1:2:4, Cast Iron Steps, complete as per drawings. to a total Depth of 2.30 metres (C.I manhole Cover, Cast Iron Steps and Earth work excavation will be paid for separately under relevant Item)
Extra depth for circular type manhole 1520 mm internal dia at top and 560 mm internal dia at top beyond the Initial depth of 2.30 m
Supplying and fixing Cast Iron Man hole or Cast Iron Steps cover of approved make and weight as specified in the drawings or as directed by the Engineer in charge.
Supplying and fixing CI cover 300 x 300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg
Providing, supplying, fixing in position, under floors or in walls sand cast iron pipes including required specials like bends, tees, 'Y' collars, cowl etc for soil, waste and ventilation pipes conforming to IS.1729 or Cast Iron hubless pipes confirming to IS 15905 of approved make including cost of jointing with spun yarn and molten lead of specified quantity, caulking the joints, including testing of pipes, painting with primer, fixing at walls with necessary approved type of clamps and brackets complete all as per drawings and specifications and as directed at site.
75 mm dia sand cast iron S&S pipe as per IS:1729 with 0.90 kg lead / joint or Cast Iron hubless pipes confirming to IS 15905
100 mm dia sand cast iron S&S pipe as per IS:1729 with 1.00 kg lead / joint or Cast Iron hubless pipes confirming to IS 15905
150 mm dia sand cast iron S&S pipe as per IS:1729 with 1.20 kg lead / joint or Cast Iron hubless pipes confirming to IS 15905
Providing, supplying, fixing in position in walls Rain water down take pipes using Centrifugally cast iron pipes (3.00 metres long) including required specials like bends, shoes etc for Rain water down take pipes Confirming to IS.3989 or Cast Iron hubless pipes confirming to IS 15905 of approved make including cost of Jointing with spun yarn and molten lead of specified quantity, caulking the joints, including testing of pipes,painting with primer , fixing at walls with necessary approved type of clamps and brackets complete all as per drawings and specifications and as directed at site.
100 mm C.I rain water down take pipe with 1.00 kg lead / joint conforming to relevant IS or Cast Iron hubless pipes confirming to IS 15905
Providing and fixing cast iron nahani trap / floor trap of 100 mm inlet and 75 mm outlet, (weighing 5.80 Kg each), jointing with lead with the connection pipes, placing as per the drawings, embedding in cement concrete 1:2:4 and making circular hole up to floor level using 110 mm O/D PVC pipes of 6 Kg / sq.cm pressure and fixing 1 No 125 mm dia C.P. brass grating, complete all as specifications and drawings and as directed by the Engineer-in-charge.
Providing and fixing heavy quality stainless steel / C.P brass grating of approved equivalent make as specified for floor traps / nahani traps all as directed by the Engineer-in-charge
SS grating 150 mm square with frame
Providing and fixing 150 mm x 150 mm cast iron grating for rain water down takes at roof including chipping and grouting complete all as directed by the Engineer-in-charge
Providing and constructing storm water chambers of Internal size clear dimension of 900mm x 600 mm in 230 thick brick masonry with cement mortar 1:4 over a bed of 150 mm thick 1:4:8 cement concrete foundation, plastering with cement mortar 1:4 20 mm thick on inside, out side and all exposed surfaces finished with a floating coat of neat cement, embedding the C.I frame and cover / RCC precast slab by making suitable rebate in concrete and fixing cast iron steps if necessary at 300 mm intervals complete as directed by the Engineer-in-charge. Depth of chamber not exceeding 900 mm. (Excavation, soling, cast iron cover, C.I steps and precast slab will be paid separately under relevant item)
Providing and fixing Indian water closet (Orissa pan) of approved make with 100 mm China ware P or S trap, One no. 10 litre High level or low level white PVC flushing cistern with flush pipe & bend with manually controlled device (handle lever) conforming to IS:7231, PVC 15 mm Inlet connection with all fittings and fixtures complete including all connection, embedding in position commissioning, cleaning etc. all as per drawings and specifications and as directed by the Engineer-in-charge.
White Vitreous china Orissa pattern W.C. pan of size about 580x440 mm
Providing and fixing white vitreous china European type Water Closet with 'P' or 'S' Trap with solid seat and lid of approved make, 10 litre low level white PVC flushing cistern with manually controlled device (handle lever) conforming to IS:7231, flush bend, fixing EWC with C.P brass screws, 15 mm PVC heavy quality inlet connection of 450 mm long, including testing , commissioning & cleaning etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge
E.W.C. pan in White colour with ISI marked white solid plastic seat and lid.
Providing and fixing white vitreous china flat back half stall urinal size 580x380x350 mm / 610 mm of approved make with Push cock of approved make,with CP brass flush pipe unions, heavy quality C.P. brass spreaders, C.P waste coupling with dome grating, clamps complete all as per specifications drawings and as directed by the Engineer-in-charge. Note : Tentative/suggested make for the guidance of the bidder (s) : Aquaseal model or approved equivalent make
Providing and fixing vitreous China wash basin of approved make and colour with C.I. brackets, 15 mm C.P. brass pillar tap of approved make,15 mm x 600mm long PVC Inlet connection, 32 mm heavy quality C.P. brass waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls and testing complete all as per specifications and as directed by the Engineer-in-charge
White vitreous China wash basin size about 630 x 450 mm and equivalent sizes with single 15 mm C.P. brass pillar tap
Providing and fixing 6 mm thick mirrors of size 600 x 450 mm of approved make with bevelled edges complete with 6 mm thick asbestos sheet back ground fixed to walls with C.P. brass screws and concealed washers complete. all as per specifications and as directed by the Engineer-in-charge .
Extra for providing and fixing mirrors with approved make- stainless steel 304 grade STUDS (with wall spacers) complete all as per specifications and as directed by the Engineer-in-charge
Providing and fixing stainless steel toilet paper holder recessed type of approved make and type with S.S screws as directed by the Engineer-in-charge complete.
Providing and fixing 150 X150 mm soap dish of white vitreous Chinaware, of approved make including chasing walls making good the same after fixing the China Soap dish etc. complete all as per specifications and as directed by the Engineer-in-charge
Providing and fixing heavy quality CP brass bottle trap 31 / 32 mm of approved make single piece moulded with height of 270mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal,of approved make for wash basins / urinal etc all as per specifications and directed by the Engineer in charge.
Providing and fixing C.P brass towel rail of approved make 600 mm long complete fixed to walls with 30 mm CP brass screws with concealed fitting arrangement all as directed by the Engineer-in-charge.
Providing and fixing Brass 15 mm C.P auto-shut urinal flush cock of approved make and quality as directed by the Engineer-in-charge. Note : Tentative/suggested make for the guidance of the bidder (s) : Presstomatic series / model or approved equivalent make
Providing and fixing 15 mm PVC inlet connection suitable for hot and cold water 600 mm long with nuts and washers complete for wash basins/ Urinals etc. with all necessary accessories complete as directed by the Engineer-in-charge
Providing, supplying and fixing JET spray with 1.00 metre long flexible tube connection in European / Anglo Indian closet under seat cover fixtures complete all as specified and as directed by the Engineer-in-charge
Providing, hoisting and installing at required elevation moulded HDPE cylindrical vertical water storage tanks of approved make of the following capacities with WHITE SILICON coated and with suitable S.M.C. cover at top including the cost of labour for making hole in the storage tank for inlet, outlet, scour and overflow, providing and fixing necessary G.I nipples ranging from 15 mm to 50 nn n.b of average150 mm length with double check nuts, washers etc. complete as directed by the Engineer-in-charge.
HDPE CYLINDRICAL vertical storage water tank white silicon coated 500 lit capacity
Providing and laying in position Fill-Crete cement concrete (Flowable Fill) of proportion 1:12 (1 cement : 12 crushed sand) brought from approved RMC plant including pumping, compaction, finishing etc. complete as per specifications and drawings but excluding the cost of Form work shuttering, centering complete at all levels.
Providing, transporting, lowering & laying in position at site at required elevation on prepared foundation concrete beds ready made RCC Hume pipe septic tanks of 900 mm Internal dia., constructing access shafts over the Hume pipe of internal clear size 600 mm x 600mm in brick masonry with cement mortar 1:6 raised up to ground level, plastering of the access shafts with cement mortar (1:4), 20 mm thick on in- side, outside & all exposed surfaces, finished smooth including providing c.i. steps weighing not less than 3.5 kgs. at 300 mm c/c of the access shaft chamber, depth not exceeding 1000 mm etc. complete including the cost of 1 No. of 75 mm dia. C.I. vent pipe about 3 meter long embedded in a PCC bed 450 mm x 450 mm x 300 mm & projecting 2 m above ground level & terminating with a C.I. cowl at top, & providing & fixing 150 mm dia. SWG tee as per drawing & specifications. Note : Tentative/suggested make for the guidance of the bidder (s) : M/s. Pranali Company or approved equivalent make
Providing and fixing at or near ground level Precast Cement Concrete factory made kerb stone of size 300 x 125 x 500 mm, edgings etc. as per approved patterns and setting in position with C.M 1:3 as per drawings and as directed by Engineer in Charge. Note : Tentative/suggested make for the guidance of the bidder (s) : M/s. Super Tiles & Marble Pvt. Ltd / Shree Precast or approved equivalent make ,
Providing & Fixing 304 Grade Stainless steel wire fabric mesh 30 Swg thick & 625 Holes per Sq. Inch for windows/ ventilators etc. beading will be paid seprately.complete all as directed by the Engineer Incharge.
Providing, supplying and fixing Venetian Roller Blinds of approved make with all accessories and fabricating to required sizes etc. as per approved design and approved fabric complete all as directed by the Engineer-in-charge.
Providing and fixing lay in false ceiling 600 x 600 mm perforated corrosion resistant Aluminium magnesium alloy metal panel fixed in 24 mm 'T' frame work of module 600 x 600 mm. Panels shall be of size 575 mm x 575 mm with perforation of 1.50 mm dia in a 3 diagonal square pattern giving 22% perforated area of approved colour in 0.70 mm thick Aluminium alloy 3105 with square edges Tiles to be stove enamelled on a continuous application for pre-treatment. The coils to be go through 4 stages of pre treatment three times of oven baked through conversion coating, priming and finish coat ensuring superior adhesion, high corrosion resistance and good colour stability.The coils to be painted on both sides after degreasing. inside surface to have a primer of 5 microns and a coat of natural colour of 5 microns, exposed surface to have a primer of 5 microns, binder of 5 microns and a top coat of approved colour 15 microns. Grid system for fixing ceiling tiles shall comprise of tees. The 24mm main tee runers shall be suspended at an interval of 1200mm centre to centre. The 24nn cross tee runner shall be suspended at an interval of 600mm centre to centre and further supported with 24mm cross tee with inter locking arrangements to form a Grid of 600mm x 600m. The main tee shall be supported by means of 4mm G.I.rod from slab / roof. The suspension shall be provided at 1200 to 1500mm centre to centre.provision for lights, diffusers etc. to be made including extra supports wherever necessary. A non-woven felt made of glass reinforced fibre glued oner the perforation for sound absorbtion Measurements shall be as per actual area of false ceiling with out deductions for lights and diffusers. Note : Tentative/suggested make for the guidance of the bidder (s) : M/s. Hunders Douglas ("LUXALON" model) or approved equivalent make
Supplying of Unskilled manpower/ labour for loading/ unloading, area cleaning and misc. works etc. including cost of equipement whichever is required at site.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .