Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹57.3 L+₹6.6 L (12.9%)Rejected-Finance 1 OPP NAGAR NIGAM KATNI MAIN ROAD KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | L2 | Rejected-Finance Being not lowest tenderer | |
| 3 | L3₹60.7 L+₹9.9 L (19.5%)Rejected-Finance | L3 | Rejected-Finance Being not lowest tenderer | |
| 4 | L4₹61.1 L+₹10.3 L (20.4%)Rejected-Finance F 83 GREEN PARK MAIN NEW DELHI 110016 | NEW DELHI | NEW DELHI | DELHI | 110016 | L4 | Rejected-Finance Being not lowest tenderer | |
| 5 | L5₹64.7 L+₹13.9 L (27.4%)Rejected-Finance 0 00 NEAR KRISHNA PETROL PUMP GEEDAM ROAD JAGDALPUR BASTAR CHHATTISGARH 494001 | BASTAR | CHHATTISGARH | 494001 | L5 | Rejected-Finance Being not lowest tenderer |
Tender Value
₹80 L
EMD Value
₹1.4 L
Closing Date
5 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF TUGHLAKABAD
HQ CWE AF TUGHLAKABAD AF STATION, TUGHLAKABAD PO SANGAM VIHAR NEWDELHI-110080
INTEGRATED COMPREHENSIVE MAINTENANCE OF SMQ BLOCK NO- P-2, P-11 AND P-26 AT AF STATION TUGHALAKABAD UNDER GE (AF) TUGHLAKABAD
2024_MES_639848_1
CA NO. CWE/TKD/TOKEN-85 OF 2023-24
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Tughlakabad
As per NIT conditions
8 documents required · 8 mandatory
₹1,000
GE (AF) Tughlakabad
₹1.4 L
Yes
27 Mar 2024
31 Jan 2024
7 Mar 2024
31 Jan 2024
5 Mar 2024
20 Feb 2024
Amount
Sch 'A' Part-I (B/R)(Earth work, Demolition & Dismantling)
Excavation in trenches in soft / loose soil nexc 1.5 mtr wide and not exc 1.5 m in depth etc complete and getting out in soft soil inciuding trimming sides and bottom of trenches complete all as specified and directed by Engr-in- charge.
Retuning filling in trenches including watering and well ramming in layer not exc 25 cm thick in soft/ loose soil complete all as specified and directed by Engr-in- charge.
Removing excavated surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting pointall as specified.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar incl all quoins, arches, pillars etc but excluding ashlar facings dressed stone work and precast concrete articles
Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified incl removal of debris.
Demolition of cement concrete reinforced in any position incl cut of bars as required complete all as spd and directed
Dismantling floor hearth or wall tiling including cement mortar bedding and removing debries off the premisis.
Dismantling of stone slab any thickness jointed in cement mortar complete all as specified and directed
Taking up or down any steel water tubing and connections including cleaning for refixing or removal to store and making the same for ready for re-fixing as per appropriate item complete all as specifed and directed.
Disconnecting existing water tanks,setting a side (or lowering if required) for repairs, cleaning etc and hosting, reconnecting and re-fixing in same or other position of exc 500 ltr but n'exc 1000 ltr for roof treatment portion.
Disconnecting existing water tanks,setting a side (or lowering if required) for repairs, cleaning etc and hosting, reconnecting and re-fixing in same or other position of exc 250 ltr but n'exc 500 ltr for roof treatment portion.
Dismantling of existing water tank (PVC/RCC/AC) exc 500 ltr but n exc 1000 ltr capacity and removing from site to store yard complete all as specified and directed by Enar-in-charge.
Dismantling of existing water tank (PVC/RCC/AC) exc 250 ltr but n exc 500 ltr capacity and removing from site to store yard complete all as specified and directed by Engr-in-charge.
Dismantling of wrought iron or Mild Steel work of any description complete all as specified and directed by EIC
Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) fitting such as switches, ceiling roses, pendents, regulators, sockets etc complete removing material to store for keeping in safe custody and making good disturbed surfaces of walls, floors etc all as specified as directed.
Sch 'A' Part-II (B/R)(Building Work)
M&L for Brick work with sub-Class ‘B’ bricks (with old size bricks), straight or curved on plan exc. 6m mean radius, built in cement mortar 1:6, complete all as specified and as directed.
M&L for gunniting to RCC works in column beams, slabs, chajja, facia, landing, balconies etc by dismantling of RCC (loose concrete) and chipping of unsound/weak concrete material with manual Chisel and/ or by standard power driven percussion type and cutting of steel bar including cleaning the exposed concrete surface and reinforcement with wire brushes etc , after that cleaning the steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry and placing steel bars at location where the balance steel dia is less than half including fixing the steel bars in position using epoxy resin anchor grout of approved make and painting with ant rust coating on exposed steel. The surface then be fixed by welded with hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed (dia of wire shall not be less than 4mm) & firmly anchored to the concrete surface by means of "L" shaped mild steel shear key welded with existing reinforcement. The surface then be treated with epoxy bonding adhesive having coverage 2.20sqm/kg of approved make and providing gunniting with a minimum pressure of 2 to 2.5 Kg sqcm and providing, mixing and applying 25mm thick (Average) gunniting of SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications complete all as specified and directed by Engineer-in-Charge. Note:- (i) The quoted rate shall be inclusive of all the works. (ii) Work to be carried out as in patches as directed by Engr-in-charge (iii) Rate for scaffolding upto fifth storey shall be included in quoted rate. (iv) All demolished material removed from MOD land completely distance exe 5 km. (v) The prepared area shall be neatly cleaned (vi) The rate of TMT shall not be included in the quoted rate. (vii) The final surface shall be finished with 15mm thick cement Plaster in C:M (1:4).The quoted rate shall be inclusive of the same.
M&L TMT steel bars of any dia cut to length bent shape required, including cranking bending binding with mild steel wire (annealed) not less than 0.9mm dia quality conforming to relevant IS complete all as specifieds
Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge. Note:- (a) The payment of Floor Door spring, door handle, shall be paid seperately (b) The payment of bottom lock patch, pivot and stopper of make Godrej or Harisons shall be inclusive of quoted rate (c) After fixing the toughened glass, a film shall be duly indicating MES logo shall be paseted, the quoted rate shall be inclusive of the same
M&L for Re-baring by drilling holes and fixing nozzle if required in existing concrete/brick work as in column, beams, slabs and foundation etc in any position and any description size of hole 14mm, 16mm & 22mm suitable for dowels of size 10mm, 12mm & 16mm respectively (minimum depth 140mm for 10mm & 12 mm dia bars and 180mm for 16mm dia bar, cleaning the surface properly with blow out pump & round brushes and fixing of dowel bars with epoxy resin (resin+hardner) complete all as specified and directed. Note:- (i) Adequate lap length shall be provided as per IS-456-2000. (ii) Reinforced TMT bars where incorporated in work will be paid seperately. (iii) The work shall be carried out upto four storied building with scaffolding.
M&L for providing and applying corrosion resistance non-shrink free flow, cementitious one component Micro-concrete with average thickness 75mm having compressive strength (BS 4551-80-60) 50 MPA at 28 days, Tensile strength (ASTM C 348)-2.0 N/mm2 @ 28 days, Flexural strength (ASTM C 348)-9 epoxy bonding agent TM bond EP thermax having mix density of 1.45 to 1.5 kg/ltr, compressive strength (BS-6319 PT 3)-25 Mpa at 7 days bond strength (ASTM C 881)- 11 N/mm2 at 7 days, having an over lay time of 3 hrs at 30°C pouring of micro concrete into the formwork using suitable arrangement or if required using pumping device for and the bottom shuttering after 7 days ensuring proper bond between the micro concrete and existing concrete substrate etc including all tools and tackles as per accepting office, complete all as specified and directed by Engineer-in-Charge.
Providing and fixing double action hydraulic floor spring With stainless steel cover plate minimum 1.25 mm thickness of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. Make - Godrej, Harrison
M&L stainless steel door D-type pull handle for toughned glass door of size 300x 25mm of make Godrej or Harrisons made of SS 304 materials for high corrision resistant including all fitting and fixtures complete all as specifed and directed.
M&L 5 mm thick rendering on ceiling etc surfaces in CM 1:3, finished even and smooth (without using extra cement) including taking down and complete removal from site complete all as specified and directed by Engineer-in-Charge.
M & L preparation of newly plastered surfaces and including applying two coats of cement base paint walls over and including a coat of primer complete all as specified and directed.
M&L fpr Preparing Newly Plastered Surfaces of ceiling and applying Three COATS of WHITE WASHING, complete all as specified and as directed. by Engineer-in-Charge.
M&L for Preparing New Plastered Surfaces including applying of TWO COATS of DISTEMPER OIL EMULSION (OIL BOUND WASHABLE DISTEMPER) over and including a Coat of primer, complete all as specified and as directed by Engineer-in-Charge.
M&L for 10 mm thick cement plaster with readymix plaster (as per manufaturer's instruction) on fair faces of brick wall or concrete surfaces finished even and smooth, (without using extra cement) including taking down and removal from site exe 50 m complete all as specified and directed by Enigneer-in-Charge. Note:- 1. Make of readymix plaster shall be Birla Aerocon/Ultratech readiplast/ACC Accoplast / Fosroc Chemical (India) Pvt Ltd Renderoc and as approved by GE) 2. The readymix plaster shall be procured directly from the manufacturer or their authorised dealer. 3 The contractor shall produced original purchase voucher alongwith test certificate of readymix plaster by manufacturer or their authorised dealer while claiming RAR/ Final Bill.
M&L for 15 mm thick cement plaster with readymix plaster (as per manufaturer's instruction) on fair faces of brick wall or concrete surfaces finished even and smooth, (without using extra cement) including taking down and removal from site exe 50 m complete all as specified and directed by Enigneer-in-Charge. Note:- 1. Make of readymix plaster shall be Birla Aerocon/Ultratech readiplast/ACC Accoplast / Fosroc Chemical (India) Pvt Ltd Renderoc and as approved by GE) 2. The readymix plaster shall be procured directly from the manufacturer or their authorised dealer. 3 The contractor shall produced original purchase voucher alongwith test certificate of readymix plaster by manufacturer or their authorised dealer while claiming RAR/ Final Bill.
Providing and laying Polished Granite stone (colour of Black only), flooring in required design and patterns, in linear as well as curvilinear portions of the building with 18 mm thick stone slab over and including 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge
M&L for Cement concrete type C1, 1:3:6 (using 20 mm graded stone aggregate) as in sunken floor incl finishing the surface even and smooth w/o using extra cement all as specified and directed.
M&L for cement concrete type F2 (1:7:12) using 40mm graded aggregate as in sunken portion of toilets complete all specified and directed
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate in CM 1:4 mixed with water proofing compound @ 3% by weight of cement for fixing of nahani trap or floor trap,P TRAP etc in sunken position complete all as specified.
M&L for rendering 15mm thick in cement mortar 1:4 with water proofing compound 3% by wt of cement, finished even and smooth withot using extra cement in sunken portion complete all as specified. Note:- WPC shall be measured and paid separately
Supply only integral water proofing compound. Note:- 1 The contractor shall produced original purchase voucher alongwith test certificate of readymix plaster by manufacturer or their authorised dealer while claiming RAR/ Final Bill.
M&L applying a coat of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course,then pasteing of polythene film, 150 micron, matural colour with cold cut back adhessive over sunken portion including depth of sunken area complete all as specified. After Applying the water tightness shall be checked for 24 Hrs .
M&L for leakage/seepage proof coating consisting of preparing the surface of roofs,exterior walls, parapet ,sunken area ,chajjas etc. with wire brush to remove all loose dirt, oil, grease etc. and filling cracks above 5mm thickness with Dr Fixit Pedilite URP or with plaster seal of STP Ltd and crack less than 5mm with Dr Fixit Crack X powder or with plaster seal of STP Ltd and applying Dr Fixit primeseal primer or STP Ltd (and allow today for 8hrs under touch dry condition and subsequently two coats of water proof decorative elastomeric coating system of Dr Fixit Raincoat with DFT 100 microns or shalicry 215 of STP (The surface after painting one coat shall be allowed to dry at least 6 hours before next coat) etc. complete all as per manufacture instruction and all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B1 as in slabs supported on walls, beams and columns in floors, roofs, landings balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B1 as in columns, pillars, piers, posts and struts and the like complete all as specified and directed.
M&L for rough finished surfacesof Formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers,lintels, cantilevers, shelves including supports, overhangs,etc. also splays between floors and beams, etc chajja shelves incl supports etc complete all as specified & directed.
M&L for glazed ceramic coloured designer concept tiles matching with existing tile 350x250x7 or 450x350x7mm size as in walls set and jointed in neat cement slurry over and including 10mm thick recuing in cement mortar (1:4) and pointed in coloured cement to match for work on vertical surface such as skirting dado etc all as specified and as directed by Engr-in-Charge.
M&L glazed ceramic colour (non skid) tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 Sqm ( 300 mmx300mm x 7mm thick) set and jointed in neat cement slurry and pointed in colour cement as in floor over and including 15 mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified and as directed.
Material and labour for First quality Non-skid Ceramic coloured tiles jointless, 7-8 mm thick of any size as decided by GE laid in floors with neat cement slurry @ 3Kg/Sqm over and including 15mm thick screed bed of cement mortar (1:6) and including pointing in white cement with pigment to match the shade of tiles including dismantling of floor, hearth or wall tiling including cemetn mortar bedding including removing from the premises complete all as specified and directed.
Description same as per above item but, as on dado/ skirting over and incl 10 mm thick rendering in CM 1:4 complete all as specified and as directed.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut Granite stone slab of any colour for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over and including 15 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete all as specified.
Rounding to the edge of stone slabs on edge such as cooking platform etc complete all as specified.
S&F Galvanised Steel Water Tubing 15mm Bore (dia), ‘Medium Grade’ ISI marked with all Fittings, fixed to concealed or on Walls, Ceiling or laid in Floors or any other Situation including Taking up down unserviceable Steel Water Tubing with Fittings and Connections, etc. complete all as specified and as directed.
S&F Galvanised Steel Water Tubing 20mm Bore (dia), ‘Medium Grade’ ISI marked with all Fittings, fixed to concealed or on Walls, Ceiling or laid in Floors or any other Situ-ation including Taking up or down unserviceable Steel Water Tubing with Fittings and Connections, etc. complete all as specified and as directed.
Refixing only GI water tubing of bore 20mm with all necessary fittings and fixd complete to walls and ceiling or laid in floors
Refixing only GI water tubing of bore 15mm with all necessary fittings and fixd complete to walls and ceiling or laid in floors
Providing and fixing on wall face unplasticised Rigid PVC pipes 110 mm in Bore (dia), Single Socketed conforming to IS : 13592 Type B (SWR), including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion including taking down of old pipe of any size and discription and removal from site complete all as specified and directed.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes 75 mm in Bore (dia), Single Socketed conforming to IS : 13592 Type B (SWR), including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion including taking down of old pipe of any size and discription and removal from site complete all as specified and directed.
Providing and fixing on wall face unplasticised - PVC moulded followings fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type B(SWR), including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion complete all as specifed and directed
Single tee with door : 100 mm
Single tee with door : 75 mm
Bend 87.5° : 75 mm
Bend 87.5° : 100 mm
S&F in repair for high pressure PVC connection pipe 15mm dia with Brass CP Check nut and rubber washer complete with 600 mm length complete all as specified and as directed by Engr-in-Charge.
Providing and fixing Semi Rigid PVC waste pipe for sink and wash basin 40 mm dia with length not less than 700 mm including P.V.C. waste fittings complete all as specified and directed
Providing & fixing White vitreous china water closet squatting pan (Indian type) Orissa pattern W.C Pan of size 580x440 mm along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge including provision of 150mm thick Lime Concrete Bedding complete all as specified and as directed.
BLANK
Providing & fixing White vitreous cwhite vitreous china pedestal type water closet (European type W.C. pan) with white seat and lid along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge including provision of 150mm thick Lime Concrete Bedding complete all as specified and as directed.
S&F in repair SS Health Faucet with 1.50 mtr long SS tube, as Approved, including Taking down unserviceable Health Fosset of any description, complete as all specified and directed.
S&F in repair PVC Flushing Cistern 10 LITRE capacity conforming to IS : 7231, Low Level Valve Less, Symphonic Action type, White, with Inlet, Ball Valve, Float and Handle including a Pair of Cast Iron Brackets duly Painted/Erecting Stand and PVC connection pipe 15mm size, PVC Flush Pipe of polythene 32mm dia for Low Level Flushing Cistern including Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 and fixed including Taking down/out Unserviceable Flushing Cistern and connected Items, complete all as specified and as directed.
Fixing only in repair of PVC low level cistern of 10 lit capacity inclusive of brackets and PVC bend long type and connectin to flush pipe of any size and pattern with inlet ball valve float and handle etc complete all as specified & directed.
S&F in repair Vitreous China Wash Hand Basin 630X450mm in size, White (Flat Back Type) with 32mm dia Brass Chromium Plated Waste Fitting,UPVC Bottle trap, Chromium plated pillar tap, UPVC’ 32mm bore Waste Pipe, a Pair of Cast Iron Brackets duly Painted/ Erecting Stand including Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 and fixed including Taking down Unserviceable Wash Hand Basin and connected Items, complete all as specified and as directed.
Fixing only in repairs vitreous china wash basin, white, flat back, size 550 mm x 400 mm fixed on and including cast iron cantilever bracket 32 mm dia brass waste coupling and including fixing of tap, waste fitting and union complete all as specified and as directed.
M&L for ISI marked 3 Layer Rotational moulded polyethylene water storage tanks (cylindricalvertical with closed top) conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge, hoisted and fixed in position all as specified in SSR part-I for capacity 500 liters incl hoisting fixing at speciifed location including tank nipple, union and Lowering/removing of unserviceable Water Storage Tank with Float Valve of any description complete all as specified and directed. NOTE: - (i) The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. (ii) The Contractor shall submit purchase voucher and the same shall be defaced by the Engr-in-Charge before making payment. Non-submission may lead to non-payment
M&L for ISI marked 3 Layer Rotational moulded polyethylene water storage tanks (cylindricalvertical with closed top) conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge, hoisted and fixed in position all as specified in SSR part-I for capacity 1000 liters incl hoisting fixing at speciifed location including tank nipple, union and Lowering/removing of unserviceable Water Storage Tank with Float Valve of any description complete all as specified and directed. NOTE: - (i) The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. (ii) The Contractor shall submit purchase voucher and the same shall be defaced by the Engr-in-Charge before making payment. Non-submission may lead to non-payment
S&F in repairs ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed 25 mm bore complete all as specified and directed by Engineer in charge.
S&F in repair Stainless Steel Kitchen Sink with Drainage Board of Overall Size 915X460mm and Bowl Size 410X330X160mm, made of Stainless Steel 1.0mm thick Sheet with Plugs, Chromium Plated Waste Coupling and Washer including Bedding in Cement Mortar 1:4 to Dwarf Wall or fixing Cantilever Brackets and Connection to Pipe including Taking down unserviceable Sink and Connected Items complete all as specified and as directed by Engr-in-Charge. Note: The Contractor shall submit purchase voucher and the same shall be defaced by the Engr-in-Charge before making payment. Non-submission may lead to non-payment
Cleaning of roof slab/chajja with sweeping with brooms, removing complete all as specified and directed by Engr-in-charge.
Taking down old existing roof treatment of any type including mud phuska and removing from MoD Land complete all as specified and directed by Engr-in-charge.
M&L Brushing neat cement slurry with 3kg of cement per Sqm complete all as specified and directed by Engr-in-charge.
M&L for PCC average 40 mm thick in proportion (1:2:4) type B-O using 12.5 mm graded stone aggregate as in padding finishing surface of concrete topping in floors, roofs, finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
M&L for 10mm thick plastering in CM (1:3) on green concrete roof surfaces Sqm with liquid water proofing compound as per manufature instructions surface finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge. Note - WPC shall be measured and paid separately.
M&L for preparing new surfaces including applying two coat of Polyurethane resin based top protective clear coat of minimum 80 micron each applied with rollers on properly cured and dry clean surface as per manufacturer's instruction to stop leakage/seepage from roof/wall over and including a coat of primer complete all as specified and directed by the Engineer-in-Charge. Note:- (i) The work shall be executed through authorised applicator and the applicator shall be approved by Accepting Officer. (ii) The Contractor shall submit purchase voucher and the same shall be defaced by the Engr-in-Charge before making payment. Non-submission may lead to non-payment. (iii) The Photograph of Work shall be taken and kept on record and shall be fwd along with RAR/Final bill. Non-Submission may lead to non-Payment. (iv) An Amount @ 5 % of this item including connected items shall be reserved and shall be released after completion of 10 years subject to no defects observed till that time. The contractor shall submit warrantee certificate on ther letter head in this regards.
S&F in repair Pre- painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
S & F joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc (cut to ordinary lengths i.e. with in 20 mm of the length indicated to FE 410-W (Gde-E-250 quality-B) complete all as specified and directed.
M&L for preparation of new steel surfaces exc 10cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxideprimer all as specified.
M&L in repair PVC floor trap/nahani trap ,plain with grating including jointing to waste pipe with solvent cement dia of outlet 75mm in repairs
S&F in repair,Stainless steel Plate rack of size 24"x36"x10"(all dimensions in inches) complete all as specified and directed by Engr in charge.
S & F in repairs fancy type chromium plated cast copper alloy bib taps long shank & cup 15 mm dia bore complete all as specified and as directed.
S & F in repair PVC PTMT bib tap 15mm dia pipe with crutch or butter fly handle screwed down, screwed for iron pipe or for brass ferrule complete with check nut 15mm bore, make - Polytuff /Paryag
S&F in repair of Wall mixture 15mm bore dia cast copper alloy with cap capston chromim plated screwed down high pressure with or without lettered "Hot" or "Cold" with long screwed shanks and fly buts screwed for iron pipe.
S&F in repair 15 mm dia bore stop valve, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipes or for union and fixed complete all as specified and as directed.
S & F in repairs 15 mm dia bore stop valves cast copper alloy chromium plated fancy type with long shank & cup (concealed type) complete all as specified and as directed.
S & F in repairs 15 mm dia bore cast copper alloy chromium plated fancy type angle cock with long shank & cup complete all as specified and as directed.
Supply and fixed in repair 15 mm dia bore pillar taps cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or “cold’ with long screwed shank and flynuts, screwed for iron pipe and fixed complete all as specified and as directed.
S & F in repairs 15 mm dia bore cast copper alloy chromium plated fancy type wash basin mixer for cold & hot water complete all as specified and as directed.
NOTE- The contractor shall submit the purchase voucher of all the Sanitary Fittings. The Engr-in-Charge shall deface the same and fwd the same with RAR/Final Bill. Non-Submission may lead to non-payment.
Sch 'A' Part-III (E/M Portion)
M&L for point wiring complete with 1.5 Sqmm (nominal area) PVC insulated, multi stranded, FRLSH copper conductor cable unsheathed 1.1 KV for followings items and including 20 mm medium grade ISI Marked concealed PVC conduit with all fittings and including PVC insulated FRLSH copper conductor cable of size 1.5 sq mm as earth wire all as specified and as directed by Engr-in-charge, NOTE:- (i) The works includes cutting and making good disturbed surfaces and rate deemed to included in quated rate. (ii) The contractor are requetsed to plan the work so that laying of conduit is finished during plaster stage (iii). The contractor shall submit Purchase voucher of All type of FRLSH wires used at site
For one light/fan/exhaust point controlled by one way switch all as specified and directed.
For one 3 pin sockets outlet 5 Amps on the same board with other switches with cable of size 1.5 sqmm
For 3 pin socket outlet 5Amps on independent board with cable 1.5 Sqmm size
For one 3 pin sockets outlet 15 Amps on independent Board with cables 2.5sqmm size
Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. complete all as specified & directed and as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. complete all as specified & directed and as required.
5/6 A switch -One Way
2 way 5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Bell push
S&F in replacement of Single pole and neutral enclosure with a two pin and earth including plug and socket complete set with one single pole MCB of 20 Amps,complete all as specified and directed.
Supplying and fixing two module five stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. complete all as specified & directed and as required.
S&F in replacement of Ding Dong AC. 230 volts, single pole, complete all as specified & directed by Engineer - In-Charge.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
NOTE for Item no. 95.00 to 101.00 (i) The Contractor shall submit Purchase Voucher for the same of full qunatity used at site. The Engr-in-Charge shall check the quantity and shall verify the same before forwarding the RAR/Final Bill. Non-Submission may lead to non-payment or as part thereof.
M&L for Taking out the unserviceable wall mounted Panel board including all connection and supply, installation, commissioning and testing of LT panel, indoor type, double door, IP 65 Protection, CPRI Approved base frame mounted dust proof and vermin proof with bus bar of 400 Amps current capacity to accommodate 3 Phase, 415Volt with suitable aluminium busbar designed as per relevant IS connected to busbar by aluminium strip of suitable Size, fabricated out of 3.15 mm thick CRCA sheet for outer chamber and 2 mm thick for partition and doors and painting with seven tank process with twin shutter closing, locking arrangements and with 2 nos earthing sprout connectors complete and fixed in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in foundation 40 cm above ground level including provision for fixing of MCCB 250A, 50 KA, 4Pole -1 Nos (Incomer), Digital VAF Meter, LED Indication Lamps, CT's etc and outgoing MCCB 200A, 36KA, 3 Pole-2 Nos, outgoing mcb 40 A, k0 KA, 4 pole - 2 nos, along with spare space for fixing of 01 Nos MCCB complete control wiring for the above accessories all as specified and as directed. Note:- (i) The contractor shall submit CPRI approval of Panle Manufature at the time of Sample Approval. The Sample Approval shall only be carried out after verification of CPRI Panel. (ii) The Contractor shall submit Purchase Voucher for the same of full qunatity used at site. The Engr-in-Charge shall check the quantity and shall verify the same before forwarding the RAR/Final Bill. Non-Submission may lead to non-payment or as part thereof.
Supply and fix in replacement of factory made epoxy polyster powder coated VTPN distribution board 8 way with incomer MCCB of 200Amps, 4 pole, 36KA, fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-54 protection) fixed on wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incoming and 6 outgoings complete all as specified and confirming to IS: 8623 Note: (i) Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate. (ii) The Contractor shall submit Purchase Voucher for the same of full qunatity used at site. The Engr-in-Charge shall check the quantity and shall verify the same before forwarding the RAR/Final Bill. Non-Submission may lead to non-payment or as part thereof.
Supply and fix in replacement of factory made epoxy polyster powder coated distribution board SP&N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incoming and 6 outgoings complete all as specified and confirming to IS: 8623 (Make: Legrand /Siemens). Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate. (ii) The Contractor shall submit Purchase Voucher for the same of full qunatity used at site. The Engr-in-Charge shall check the quantity and shall verify the same before forwarding the RAR/Final Bill. Non-Submission may lead to non-payment or as part thereof.
S&F in repalcement of MCB SP 6-32 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge .
S&F in repalcement of MCB SPN 40 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge .
S&F in repalcement of MCB SP 63 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge.
S& F in replacement of MCCB 200Amps, 36 KA, 4 Pole, with thermal & megnetic release setting, including spreader, complete all as specified and directed by Engr-in-charge.
S&F in replacement of submain wiring with unsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 4 Sqmm single core HR Grade and one run of 4 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB/ Geyser/ AC plug points complete all as specified and as directed. Note :- (i) Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. (ii) Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit. (iii) The Contractor shall submit Purchase Voucher for the same of full qunatity used at site. The Engr-in-Charge shall check the quantity and shall verify the same before forwarding the RAR/Final Bill. Non-Submission may lead to non-payment or as part thereof.
S&F in replacement of submain wiring with unsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 10 Sqmm single core HR Grade and one run of 10 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB/ Geyser/ AC plug points complete all as specified and as directed. Note :- (i) Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. (ii) Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit. (iii) The Contractor shall submit Purchase Voucher for the same of full qunatity used at site. The Engr-in-Charge shall check the quantity and shall verify the same before forwarding the RAR/Final Bill. Non-Submission may lead to non-payment or as part thereof.
M&L in replacement of Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated complete all as specified and directed.
S&F in replacement of LED retrofit tubelight, 4 ft long of 20 watt, complete all as directed.
S&F in replacement of LED 2 ft retrofit tubelight of 10 watt, complete all as directed.
S&F in replacement Powder coated pressure die cast aluminium compact LED building light/ street light of 45watt confirming to IP 65, complete all as specified and as directed by Engineer -in-charge. Make: Crompton cat No: LSTS-45-CDL or equivalent make of Philips /Wipro/C&S/Havell's Note: Twin core copper wire of 1.5 Sqmm upto 7Rm required for connection of street light fitting is deemed to be included in quoted rates (ii) The Contractor shall submit Purchase Voucher for the same of full qunatity used at site. The Engr-in-Charge shall check the quantity and shall verify the same before forwarding the RAR/Final Bill. Non-Submission may lead to non-payment or as part thereof.
S&F in replacement of Street light bracket of size 40mm dia light grade GI pipe, including nut, bolts, Fastner etc, complete all as specified & directed.
S&F Galvanised Steel Water Tubing 25mm Bore (dia), ‘Medium Grade’ ISI marked with all Fittings, fixed to concealed or on Walls, Ceiling or laid in Floors or any other Situation complete all as specified and as directed.
S&F Galvanised Steel Water Tubing 50mm Bore (dia), ‘Medium Grade’ ISI marked with all Fittings, fixed to concealed or on Walls, Ceiling or laid in Floors or any other Situation complete all as specified and as directed.
S&F in repairs, 20 mm Bore gun metal Gate/Globe half turn valves with iron wheel/Lever fixed-in-repairs complete all as specified and directed by Engineer in charge.
S&F in repairs, 25 mm Bore gun metal Gate/Globe half turn valves with iron wheel/Lever fixed-in-repairs complete all as specified and directed by Engineer in charge.
S&F in repairs, 50 mm Bore gun metal Gate/Globe half turn valves with iron wheel/Lever fixed-in-repairs complete all as specified and directed by Engineer in charge.
S&F in replacement of GI union of 20 mm ISI marked complete all as specified and directed by Engr-in-charge.
S&F in replacement of GI union of 25 mm ISI marked complete all as specified and directed by Engr-in-charge.
S&F in replacement of GI union of 50 mm ISI marked complete all as specified and directed by Engr-in-charge.
S&F in replacement of PPR gate valve (brass insert) of size 63 mm dia including connection and testing complete all as specified and directed including taking out old unserviceable gun metal gate valve 50mm dia Complete all as specified and directed
Supply and fixing in replacement of triple layer rotational moulded polyethylene water storage tank (cylindrical vertical with closed top ) hoisted and fixed in position all as specified in SSR part I. of size 5000 Ltrs. e
S&F in replacement of GI tank Nipple of 50mm dia, complete all as specified & directed.
Supply & laying/fixing in replacement of 3 layered (outer green coloured UV stabilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded PP-R (polypropylene Random Co-Polymer) pipes, ISI marked including plain PP-R fittings and brass threaded PP-R fittings such as flanges, elbow, bend, sockets, tee etc. as required at site and testing of joints complete all as specified and as directed of size (a) PN-16, 63mm OD (SDR– 7.4) including taking out old rusted GI pipe of 50mm dia. Note: Contractor has to provide heater & othere T&P for jointing of PPR pipe, rate are deemed to be inculede in quoted rate.
S&F in replacement of PPR union of size 90 mm dia including connection and testing complete all as specified and directed.
S&F in replacement of PPR union of size 63 mm dia including connection and testing complete all as specified and directed.
S&F in replacement of PPR union of size 32 mm dia including connection and testing complete all as specified and directed.
S&F in replacement of PPR socket of size 90 mm dia including connection and testing complete all as specified and directed.
S&F in replacement of PPR MTA of size 90 mm dia including connection and testing complete all as specified and directed.
S&F in replacement of PPR MTA of size 63 mm dia including connection and testing complete all as specified and directed.
S&F in replacement of PPR MTA of size 32 mm dia including connection and testing complete all as specified and directed.
S&F in replacement single phase Direct on line starter of capacity 2 HP overload relay range 10-17 Amp.Make- L&T Cart part No: SS97227OOBO /Havell's/ Seimens/ Schineder or equivalent ISI marked. Note: (i) The Contractor shall submit Purchase Voucher for the same of full qunatity used at site. The Engr-in-Charge shall check the quantity and shall verify the same before forwarding the RAR/Final Bill. Non-Submission may lead to non-payment or as part thereof.
S&F in replacement of tank cover suitable for 5000Ltr cap tank complete all as specified and directed.
Schedule of Credit
Neeraj Enterprises
Bee Kay Engineers & Contractors
Green Leaves
POOJA ENTERPRISES
Bluemax Associate
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .