Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Tender Accepted | |
| 2 | L2₹46.6 L+₹19.1 L (69.4%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹48.8 L+₹21.3 L (77.6%)Rejected-Finance NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹49.2 L+₹21.7 L (78.8%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹51.9 L+₹24.4 L (88.9%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
26 Feb 2020, 6:00 pmClosed
GE I R AND D East Bangalore
GE RD East Bangalore 93
REPAIRS AND MAINT OF CASETTE WINDOW SPLIT TYPE PACKAGE AC AT ADE DEBEL GTRE CABS UNDER GE I RD EAST BANGALORE
2020_MES_321715_1
8904
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND D East Bangalore
D c (i)
9 documents required · 9 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹89,000
Yes
30 Mar 2020
4 Feb 2020
2 Mar 2020
4 Feb 2020
26 Feb 2020
21 Feb 2020
5 Feb 2020 - 19 Feb 2020
Amount
Supply and fix in replacement of unserviceable micro processor PC board with new microprocessor PC board by dismantling /disconnecting the same carefully without disturbing other components up to 3 TR capacity AC including making necessary fixing arrangement etc., complete all as directed. Make : LG/Carrier/Voltas/Bluestar
M&l for dismantling of split AC complete inner and outer unit upto 2 TR after removing all connection like refrigerant pipe/voltage stabiliser safely and rexing the same at the other location including making all connection and testing in on position all as specified and directed. (Rate quoted by contractor shall deemed to include for core cutting/wall cutting including making hole for refrigerant pipe etc . No extra items except refrigerant gas if reqd shall be paid)
M &L for dismanling of window type AC from its own position and refixing the same in other location safely including making connection and testing complete all as specified and directed.
Taking down perished Unserviceable insulation cover of refrigerent piping and Supplying & Fixing brutile rubber insulation for refrigerent pipings of suitable size.
Supplying and Fixing in repairs Copper refrigerant pipe Copper tube 5/8 " x 3/8".
Supplying and Fixing in repairs Copper refrigerant pipe Copper tube 1/2 " x 1/4".
Supplying and Fixing in repairs Copper refrigerant pipe Copper tube 5/8 " x 1/4".
Material and Labour for removing the Split type Air conditioner outdoor unit/indoor unit from its position for pressure/ leak testing & arresting the leakages in condenser coil /cooling coil by brazing etc and gas charging as per reqd basis complete for Split type AC 1.5 ton / 2.0 ton / 3 TR (Notes : Rates quoted by the contractor shall includes for refrigerant gas charging as per required basis
Supply and fix in replacement of rotary type compressor for window/split air conditioner of cap 1.5 TR Air conditioning including making all connection , testing all as specified and directed. Make: Emerson/Tecumshah/toal line
All as per item No-9 above but of capacity 2 TR Split AC
Material and Labour for complete servicing after pumping down Indoor/outdoor units of split AC complete by cleaning condenser/ Evaporator coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary applying oil in fan motor bushes checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, cleaning the air filter for split air conditioner upto 2 TR all as specified and directed. Notes :- (i) The rate deemed includes for minor spares (ii) Gas shall be measured and paid separately under relevant item.
All as per item No.11 here in before but for Split type Air Conditioner 3.0 Ton ( 2 x 1.5 TR)
All as per item No.11 here in before, but for Window Type Air conditioiner upto 1.5 TR cap
All as per item No. 11 herein before, but for 3 TR capacity cassette/tower type AC
All as per item No. 11 herein before, but for 4 to 5 TR capacity split/ multi split/tower type AC
All as per item No. 11 herein before, but for 3 to 5 TR cap ductable type AC including control panel
Servicing the Voltage Stabilizer upto 5 KVA single phase of make - Soft line or equivalent after strip opening covers, taking out the burnt out winding from the transformer rewind with super enamelled copper winding wire, insulate properly, setting/testing of buck/boost relay, replacement of U/S electronic parts, assemble back & fixing in its original position including testing for proper functioning complete all as specified and as directed.
Supply and fixing in replacement of relay for automatic voltage corrector capacity upto 5 KVA, 230V AC suitable for make V guard/Volina/Syscom.
Supply and fixing in replacement of Electronic PCB for voltage stabilizer 5 KVA, 230V ACsuitable for make V guard/Volina/Syscom
Supply and fixing in replacement of Electronic PCB for voltage stabilizer of cap 4 KVA, 230V ACsuitable for make V guard/Volina/Syscom
Cleaning of external surface to window/split/cassette type AC of any capacity or any type including writing MES No etc complete all as specified and as directed by Engineer in Charge
Supply and fixing in replacement of transformer of voltage stabliser of cap 4 KVA including making all connection suitable for make V V guard/Volina/Syscom all as specified and directed.
Supply and fixing in replacement of transformer of voltage stabliser of cap 5 KVA suitable for makeV guard/Volina/Syscom including making all connection all as specified and directed.
Supply and fixing in replacement of front grill of existing window type AC of 1.5 TR as per existing make like LG/Hitatchi/Samsung/ Voltas etc all as specified and directed.
Supply and fix in replacement of remote for split type A/C, 1.5 TR/2 TR capacities along with wiring as per existing all as specified and directed. Make : LG/Voltas/Hitatchi/Bluestar/Carrier/Samsung
Disconnecting and taking down unserviceable overload relay from window/split type air-conditioner up to 3 TR capacity includign supply and fix new overload relay, testing and commissioning for satisfactory performance complete all as directed.
Disconnecting and taking down unserviceable thermostat from window /split type air-conditioner up to 3 TR capacity, supply and fix new thermostat, testing and commissioning the same for satisfactory performance complete all as specified and directed.
Suppky and fix in replacement of UNSV starting capacitor of 80/100 mfd suitable for split/window type Air conditioner upto 3 tr all as specified and directed. Make: Sarda/toal line
Supply and fix in replacement of running capacitor 25/36/45/50 mfd suitable for window/split type air conditioners up to 3 TR capacity. Make: Sarda/toal line
Disconnecting and taking down unserviceable internal wiring of window/split type air conditioner up to 3 TR capacity and supply and rewiring complete with copper conductors complete including testing and commissioning all as specified and as directed.
Supply and fix plastic /coir filter suitable for window/split type air conditioner up to 3 TR capacity including taking down old unserviceable plastic filters etc complete all as specified and as directed.
Removing defective unserviceable fan blades from window/split type air-conditioners up to 3 TR capacity and supply and fix new blade suitable for air-conditioners of existing make of LG/Blue star/Voltas/Carrierall as specified and as directed.
Time delay timer cum single phase preventer suitable for 2 TR / 3 TR capacity any make and any model of split type AC including taking down unserviceable timer etc., complete all as specified and as directed.Make : L & T/GIC/BCH/Minilec
Supply and lay PVC insulated cable flexible type with copper conductor 4 sq mm 3 core suitable for window/split type air-conditioner up to 3 TR capacity of length 3 mtr all as specified and as directed.Make Havells/Polycab/Finolex/RPG
Opening dismantling and removing the indoor unit of split air conditioner of cap 1.5 /2 TR and supply & fix new indoor unit of split air conditioner of 1.5/2 TR complete with making all connection all specified and directed by EIC. Make- LG/Voltas/Blue star/Samsung/Carrier or as per existing make
Supply & Charging refrigerant gas R-22/407C/134a. Make- Fluron/Mettron/Refron
Supply & fix in replacement of compressor oil servo friz F-68 of Indian oil or equivalent in BPCL/HPCL,complete all as specified
Supply and fix in replacement of outdoor condensing unit of split type AC 1.5/2 TR Capacity all as specified and directed.Make: Voltas/blue star/carrier
Supply and fix in replacement of new hermetically sealed compressor for 1.5 TR capacity split type AC including removing of unserviceable sealed compressor unit etc complete all as specified and directed. Make: Emerson/Tecumshah/toal line
All as per item No-39 above but of 2 TR
All as per item No-39 above but of 3 TR
Removing defective unserviceable condensing coil fan motor from split type air-conditioners up to 3 TR capacity and supply and fix new condensing coil fan motor suitable for air conditioners upto 3 TR all as specified and directed
Supply and fix in replacement of voltage stabilizer of 5 KVA capacity including testing etc complete all as specified and directed and taking down old unserviceable. Make V Guard/volino
Removing defective unserviceable blower fan motor indoor unit from split type air conditioners of 3 TR capacity and supply and fix blower fan motor unit suitable for split air conditioners up to 3 TR, complete all as directed.
Supply and fix in replacement of phase failure relay suitable for window/split type air conditoner upto 3 TR all as specified and directed. Make -VSP/Minilac
Supply and fix plug top metal clad 3pin 20 Amps suitable for window/split type air conditioner up to 2 TR capacity all as directed.Make Anchor/Finolex/Havells
Insulating the suction/ discharge line of split type air conditioner up to 3 TR capacity with necessary insulating filter wool 6mm thick complete all as specified and directed.
Supply and fix Contactor 240 volt, up to 32 Amps suitable for window/ split type AC capacity up to 3.0 TR including dismantling of existing contactor complete all as specified and as directed.Make havells/LG/L&T/BCH
Dismantling unserviceable cooling coil from 1.5/2/3 TR capacity split AC carefully without damaging the other parts supply and fix new cooling coil made out from seamless hard copper pipe including brazing and pressure testing dry nitrogen gas including charging of R-22 refrigerant gas testing, commissioning, etc suitable for make LG/Bluestar/Voltas/Carrier., complete all as specified and as directed.
Supply and fix MCB TP 32/63 Amps 16 KA including taking out Unserviceable MCB etc all as directed.Make : Havells/Indoasian/Legrand
Material and labour for Industrial type sheet metal plug and socket complete with MCB SP 20A complete all as directed and taking down old unserviceable ones. Make : Havells/Indoasian/Legrand
Supply and fix in replacement of blower of split air conditioner upto 1.5/2 TR capacity as per existing make and model suitable for make LG/Bluestar/Voltas/carrier Air conditioning including making all connection and testing for entire satisfaction to Engr-in- charge
PVC insulated cable flexible type with copper conductor of size 2.5 Sqmm 3 core suitable for window/split type air conditioner up to 3 TR capacity upto 3 Mtr length complete all as specified and as directed
Pressure testing and rectifying leakage in the system of window/split air conditioner up to 3 TR to 5 tr capacity including gas charging, testing for satisfactory performance, commissioning all as directed.
Removing defective PC board carefully with out disturbing the cooling coil and fan motor of upto 3 TR air conditioner and taking to reputed workshop check throughly and rectifiy the fault including replacement of IC transformer and connected accessories and refixing back to original position including testing and commissiomning etc complete all as specified and directed
Supply and fix complete body made out from 24 SWG GI sheet with powder coating of split type AC suitable for fixing of condenser coil, compressor and other accessories of 2 TR capacity split type AC including taking out unserviceable rusted existing outer body of 2 TR capacity slit type AC complete all as specified and as directed.
Supply and fix MCB SPN 32 Amps 16 KA including taking out Unserviceable MCB etc all as directed.
Removing old rusted outdoor unit split air conditioner stand upto 2 TR from the existing site and supply and fix new stand made of mild steel as per existing without disturbing/damage the copper piping etc all as specified and directed.
Sahara Engineers
Glacier Cooling Solutions Private Limited
devan enterprises
RASI AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .