| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.2 LAccepted-AOC H NO 861 SECTOR 1 4 HOUSING BOARD COLONY NEAR POLY CLINIC HISAR HARYANA | HISAR | HARYANA | 125001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹35.7 L+₹1.8 L (5.35%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹37.0 L+₹3.1 L (9.02%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹38.6 L+₹4.7 L (13.8%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹39.4 L+₹5.5 L (16.3%)Rejected-Finance H NO 29 DEVILAL COLONY TCP 2 HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L5 | Rejected-Finance Being L5 |
| Sl No | Description | Qty | Unit | R N Enterprises L6 | M/s Devendera construction L5 | KUNAL ENTERPRISES L8 | Natwadia Electrical Company L1 | Om Sai Enterprises L7 | M/S SURJIT CONSTRUCTION COMPANY L2 | DHARMA CONSTRUCTION L3 | FOUJI ELECTRIC WORKS L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully existing LT panel of any cap and size including connected item i.e LT cable, PCC foundation and cleare the site complete all as specified and directed. | 8 | Each | 200 ₹1,600 | 200 ₹1,600 | 477 ₹3,816 | 300 ₹2,400 | 2,000 ₹16,000 | 600 ₹4,800 | 100 ₹800 Lowest | 1,000 ₹8,000 |
| 2.00 | Supply, installation, commissioning and testing of LT Panel out door type ,LT 415 Volts, 50 Hz , 3-phase, 4 wire supply, size of LT panel not less than 1.5 m high x 2.5 m width x 1.0 m depth CPRI approved/tested, factory assembled ,out door type, weather and vermin proof (Protection Class IP-54) made out of 3.15 mm (for external) and 2.00 mm (for internal) thick MS Sheet CRCA sheet with both side (front and back) hinged, double door opening for external, rubber lining, locking arrangement, painted internally and externally with powder coating of grey shade (RAL-7032) as per seven tank process complete mounted on chanel iron of size 75mm x 40mm x 5 mm mounting on blocks of PCC 1:2:4 type C1 of block size 60x60x60 cm comprising of the following. (a) Bus bar chamber having 4 nos air insulated Aluminium strip bus bars of rating not less than the 1.5 times the rated capacity of the incomer ACB/MCCB, bus bar must be colour coded heat shrinkable as well as outgoings shall have aluminium four pole (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.:- (a) INCOMING :- (i) ACB 4 pole , LT 415 Volts, 50 Hz AC grade of 800 Amps rating 50 KA rupturing capacitiy with Adjustable Thermal and Fixed Magnetic setting - 01 No. (ii) Voltmeter 0-500 V digital type with 3 way rotary selector switch - 01 No (iii) Ammeter 0-800 Amp digital type with 3 way rotary selector switch - 01 No
(iv) Indicating lamp one set of three (v) CT of suitable size class-1 ISI marked - 01 Set of three (b) OUTGOINGS (i) MCCB 4 pole, 415 Volts, 50 Hz AC, 250 Amps 36 KA rupturing capacitiy with Adjustable Thermal and Fixed Magnetic setting -8 Noc. (ii) MCCB 4 pole, 415 Volts, 50 Hz AC, 63 Amps 25 KA rupturing capacitiy with Adjustable Thermal and Fixed Magnetic setting - 1
No. Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples.(ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint (iii) All MCCB should be connected to Bus bar directly through expended links | 6 | Each | 4,25,550 ₹25,53,300 | 4,75,000 ₹28,50,000 | 3,77,777 ₹22,66,662 | 2,75,000 ₹16,50,000 Lowest | 3,20,000 ₹19,20,000 | 3,20,000 ₹19,20,000 | 3,75,000 ₹22,50,000 | 4,25,000 ₹25,50,000 |
| 3.00 | All as per item No 2 here-in-before, size of LT panel not less than 1.0 m high x 1.5 m width x 0.5 m depth but incommer & outgoing as per the following:- (a) INCOMING :- (i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 400 Amps rating 36 KA - 01 No. (ii) Voltmeter 0-500 V digital type with 3 way rotary selector switch - 01 No
(iii) Ammeter 0-400 Amp digital type with 3 way rotary selector switch - 01 No
(iv) Indicating lamp one set of three (v) CT of suitable size class-1 ISI marked - 01 Set of three
(b) OUTGOINGS (i) MCCB 4 pole, 415 Volts, 50 Hz AC, 250 Amps 36 KA -1 Nos. (ii) MCCB 4 pole, 415 Volts, 50 Hz AC, 63 Amps 25 KA -8 Nos. | 2 | Each | 1,38,970 ₹2,77,940 | 1,80,000 ₹3,60,000 | 87,777 ₹1,75,554 | 75,000 ₹1,50,000 Lowest | 1,20,000 ₹2,40,000 | 90,000 ₹1,80,000 | 1,50,000 ₹3,00,000 | 1,77,000 ₹3,54,000 |
| 4.00 | M&L for earthing complete in replacement with galvanized earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth streep 25x4 mm by welding thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 40mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, welding, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete including taking down existing u/s earthing all as specified & as directed. | 16 | Each Job | 2,280 ₹36,480 | 2,300 ₹36,800 | 2,777 ₹44,432 | 5,000 ₹80,000 | 4,500 ₹72,000 | 4,700 ₹75,200 | 2,000 ₹32,000 Lowest | 2,800 ₹44,800 |
| 5.00 | Supply , laying, jointing, testing and commissioning in replacement of LT underground cable, 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased cable of size 35 sqmm 3.5 core, including taking out old us cable complete all as specified. | 450 | RM | 199 ₹89,550 | 180 ₹81,000 | 277 ₹1,24,650 | 225 ₹1,01,250 | 280 ₹1,26,000 | 250 ₹1,12,500 | 180 ₹81,000 | 170 ₹76,500 Lowest |
| 6.00 | All as per item No 5.00 (here-in-before) but 95 Sqmm 3.5 core. | 300 | RM | 405 ₹1,21,500 | 250 ₹75,000 Lowest | 547 ₹1,64,100 | 487 ₹1,46,100 | 540 ₹1,62,000 | 320 ₹96,000 | 400 ₹1,20,000 | 300 ₹90,000 |
| 7.00 | All as per item No 5.00 (here-in-before) but 120 Sqmm 3.5 core. | 280 | RM | 480 ₹1,34,400 | 330 ₹92,400 Lowest | 677 ₹1,89,560 | 610 ₹1,70,800 | 645 ₹1,80,600 | 450 ₹1,26,000 | 500 ₹1,40,000 | 415 ₹1,16,200 |
| 8.00 | All as per item No 5.00 (here-in-before) but 185 Sqmm 3.5 core. | 250 | RM | 680 ₹1,70,000 | 450 ₹1,12,500 Lowest | 977 ₹2,44,250 | 937 ₹2,34,250 | 1,265 ₹3,16,250 | 810 ₹2,02,500 | 700 ₹1,75,000 | 550 ₹1,37,500 |
| 9.00 | All as per item No 5.00 (here-in-before) but 240 Sqmm 3.5 core. | 200 | RM | 829 ₹1,65,800 | 550 ₹1,10,000 Lowest | 1,277 ₹2,55,400 | 1,168 ₹2,33,600 | 1,462 ₹2,92,400 | 930 ₹1,86,000 | 820 ₹1,64,000 | 700 ₹1,40,000 |
| 10.00 | All as per item No 5.00 (here-in-before) but 400 Sqmm 3.5 core. | 200 | RM | 1,650 ₹3,30,000 | 650 ₹1,30,000 Lowest | 1,977 ₹3,95,400 | 1,800 ₹3,60,000 | 2,270 ₹4,54,000 | 1,450 ₹2,90,000 | 1,550 ₹3,10,000 | 900 ₹1,80,000 |
Tender Value
₹38.8 L
EMD Value
₹77,620
Closing Date
23 Sept 2025, 6:00 pmClosed
GE Hisar
GE Hisar
SPL REPAIR / REPLACEMENT OF LT PANEL AND CONNECTED ITEMS IN DSTV JCOs / ORs MD ACCN AT HISAR MIL STN UNDER GE HISAR
2025_MES_727408_1
GE(H)-31/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
GE Hisar
As per NIT
6 documents required · 6 mandatory
₹500
GE Hisar
₹77,620
Yes
27 Oct 2025
23 Aug 2025
1 Oct 2025
23 Aug 2025
23 Sept 2025
8 Sept 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .