SE,EDC-IV,LESA-CISS GOMTI,MVVNL
4/82-83, INDERLOK HYDEL COLONY, KRISHNANAGAR, LUCKNOW
FOR THE WORK OF -Sifting of 11 KV Line and other work against deposit scheme (Package no. 369 and 370/19-20) UNDER JURISDICTION OF E.E., EDD, CESS-I, CISS GOMTI, LESA, Lucknow
2020_MVVNL_449994_1
128/EDC-IV/LESA/2019-20
Open Tender
Miscellaneous Works
Fixed-rate
90 days
Lucknow
AS PER TENDER DOCUMENT
2 documents required · 2 mandatory
₹1,180
A/C-1444100402,IFSC Code-CBIN0280139
₹7,000
3 Apr 2020
17 Mar 2020
23 Mar 2020
17 Mar 2020
23 Mar 2020
17 Mar 2020
Amount
Safe Loading, Carriage & unloading of following Materials from Centre Store to Pit Site/J.E. Dump Store.
a- Line Material
b- PCC Pole
c- ST Pole 11/9 Mtr. Long
d- T/F 250 KVA
e- 11 KV XLPE Cable 3x185 sq. mm.
f- ABC 3x120/3x95 sq.mm.
g- LT PVC Cable 1x240/1x400 sq.mm.
Dragging of ST/PCC Pole digging of pit erection of sub-station type double pole structure on ST/PCC Pole with fixing of necessary item such as Top Channel, along with grouting (As per RESPO Norms) Dropper Channel, 11 pin insulator with Pin & 11 KV Disc Insulator with fitting, DO Fuse set its ramming, as per RESPO Specification. Only Pole and insulator will be Provided by the Department.
Fabrication, erection of double pole for end terminations/sectional double pole, 11 KV line on ST/PCC Pole with fixing of necessary clamps & other accessories like 1 nos top channel 100x50 mm 2.24 m. 1 No. Guarding Angle. Its grouting in ratio 1:4:8 plinthing 300 mm above ground level, earthing of support & one side cable expose.
Dragging of ST/PCC Pole from Dump Store to pit site, diging of pit erection and grouting (As per RESPO Norms) of LT support suitable for laying of ABC Line on 8.5 Mtr Long PCC Pole by providing of necessary eye hook/Lt Shackle insulator with Clamps and its accessories etc. as per RESSPO Specification. Only Pole will be Provided by the Department.
Grouting & Nuzzling of 11 KV stay set complete including fixing of necessary clamps. Accessories required including its grouting by civil material (Sand, Brick blast & cement). All material except stay wire shall be supplied by the contractor.
Ordinary earthing by 11 KV MS earth Rod 2500mm long as per RESPO Schedule. All material except earthing wire shall be supplied by the contractor.
Laying of 3X185 sq.mm 11 KV XLPE cable by drill method as per RESPO Norms. Only 11 KV XLPE cable supplied by Department.
Proper laying & commissioning of (3x95/3x120 sq.mm) XLPE Aerial Bunched Conductor. Only ABC Provided by deptt.
Cable Hosting of 11 KV 3x185 sq. mm XLPE Cable at the following including jumpering etc complete with help of GI Pipe as Per RESPO Norms. GI pipe and other required material shall be supplied by contractor.
High pressure testing of 11 KV 3x185 XLPE cable along with arrangement of High Pressure equipment.
Well type earthing of with 60 Fit Deep borring and providing GI Pipe 1.5" dia ("B" Class) and earthing must be joint by G.I. Strip of 32x5 mm thick long attached with nut & bolts and GI pipe cap. All material and labour shall be supplied the contractor.
Construction of T/F plinth of size 2x2x1.2 mtr with the help first class brick & masonary in the ratio 1:4 cement & sand coarse. Filling the structure completely per norms with RCC to 1:2:2 cement & stone grit with MS bar and MS channel for resting transformer.
Wiremess fencing of 11/0.4 KV S/S shall be made of rectangular of size as per site requirement not exceeding 3 meter fabrication 45x45x5 mm angel the frame is also have 1 no. Horizontal runner of MS flat 40x5 welded in middle to support of wire mesh. Rectangular welded type wire mess of size 50x25 made of 12 S.W.G. wire mess shall be welded all along the periphery of the frame as well as on horizontal runner to give extra strength of welding to wire mess welded on the frame. Diagonal bracing of all the frame panel will be welded with Ms flat of size 25x3mm to support as per RESPO specification & direction of E/I.
Construction of masonry/metalic type distribution pillar of size 1x1.5x2.5 mtr. with supply & fixing of fabricated 4 nos. doors (2ft.x4ft.) made of BP sheet of 18 SWG with locking arrangement, 2 Nos. Straight MS angle 50x50x6mm (1800 mm olng) 2 nos. 500 Amp, 3 Nos. 300 Amp henely Type Tailess Funse Unit, 3 Nos coper bus bar of size 1000x50x6 mm and one No. Alum busbar 1000x50x6 mm including all civil material required for work. All material shall be supplied by contractor.
Fabrication, errection & commissioning of 250 KVA T/F on Plinth Pole with all accessories. All material except 250 KVA T/F shall be supplied by the Contractor.
Fabrication, errection & commissioning of 400 KVA T/F on Plinth Pole with all accessories. All material except 400 KVA T/F shall be supplied by the Contractor.
Dismantling of Old HT line/LT Line/Pole and other material including rolling back its conductor, wire, pole including stacking & transporation of these materials form site to JE dump store/Central Store Daliganj, Lucknow.
Safe Dismantling of 400 KVA Transformer as per RESPO Norms
Laying and Fixing of LT PVC cable 1*400/1*240 sq. mm with required Allu. Lugs and L-Piece as Per RESPO Norms. Only PVC Cable shall be supplied by Deptt.
Lopping & Chopping of tree branches for clearance of HT/LT line. After clearance of line through out pieces of tree branches of site.
Tax as payable time to time shall be paid by department
CHAUHAN ELECTRICALS
M/S SURAJ ASSOCIATES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .