14 conditions · 2 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Form-2, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria: The Tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any work of provision or maintenance of Data Logger or RTU or other remote sensing eqipment for predictive/preventive maintenance of Signaling gears OR Any work in connection with Signaling Installation and which includes data logger and/or RTU and/or Other Remote sensing equipment for predictive/preventive maintenance of Signaling gears. OR Any other signaling work involving indoor wiring. Note 1: Tenderer may be required to submit the schedule of those works, Completion/Performance Certificates of which have been submitted by him/her in support of 30 / 40 / 60 % (as the case may be) criterion of similar nature of work.
15 conditions · 10 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Registered Office Address with contact no.
Detail of Bid Security paid, through only payment modes available on IREPS portal like net banking, debit card, credit card etc.
PAN Number to be attached.
Mandatory undertaking regarding Employment/Partnership of Retired Railway Employees as per Clause No. 12 of Chapter-I as per Annexure- E.
Mandatory certificate to be submitted by tenderer along with tender documents as per Annexure- A.
GST Number to be attached.
Mandatory Power of Attorney to be submitted by tenderer along with tender documents as per Annexure- B.
MOA & AOA, Resolution of Board and POA, Sole Proprietorship, Notarized partnership deed with POA and latest certificate of registration with Registrar of the firms must be attached. Year of Formation / Incorporation. (As per Clause-10 of Tender Document.
Upload duly filled and signed Cover Letter (Tender Form 1).
Mandatory Document Tenderer uploaded Annexure-A (1) {This certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV)/Hindu Undivided Family (HUF)/Limited Liability Partnership (LLP) etc.)}of tender documents.
An undertaking by the tenderer shall be provide at the time of tender submission that the equipment shall be procured from RDSO/TEC/OEM covering supply, installation, testing, commissioning of system including after sales support required during the warranty period.
The tenderer must be OEM of data logger or an Authorised representative of OEM of data logger. Tenderer will have to submit the proof of same with the tender document.
Provision of RTU at Interlocked Mid-Section LC Gates over Delhi Division.
558-Sig-16-M-Tender-1474
558-Sig-16-M-Tender-1474
Open
Works - General
12 Months
Delhi, Delhi
₹0
₹7.5 L
4 May 2026
10 Apr 2026
20 Apr 2026
35 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,75,30,585.43 | ||
| — | 75.00 | — | — | ||
| Supply of Micro Processor based Remote Terminal Unit (RTU) with 128 digital input & 16 analog input as per RDSO Spec. No. IRS (S) 99/2006 (Amdt. 3) or latest. It includes supply of all the items required for complete indoor relay room wiring from RTU to relay rack tag blocks, drawing/extension of power supply up to RTU. It includes supply of relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD (if installed), IPS, interlinking and networking of RTU. Note: Total numbers of relays and other signaling functions/gears required to be wired as per list circulated vide RDSO Letter No. STS/E/Data logger dtd.12.09.2011 or latest guidelines. Inspection: RDSO. | — | — | — | 1,83,65,510.25 | |
| — | 75.00 | — | — | ||
| Installation, Wiring, Testing, Validation and commissioning of Remote terminal unit with 128 digital & 16 Analog inputs with modem as per Specification No IRS:S-99/2006 (Amdt-3) or latest. Inspection: Consignee. | — | — | — | 11,84,102.25 | |
| — | 25.00 | — | — | ||
| Supply and installation of External modem for networking of RTU. (Inspection: Supply Portion-RITES, Installation- Site In charge). | — | — | — | 5,85,871 | |
| — | 60.00 | — | — | ||
| Supply of 4G GSM modem & PCI serial port Adapter card as per specification. Parameters: a. CELLULAR TECHNOLOGY: GSM/GPRS Bands b. Supports all major INDIAN GSM/GPRS/LTE Bands CONFIGURATIONAL FEATURES: a. Configuration method: AT Command set b. USB Driver support: Microsoft Windows 000 / XP / Vista / Win7 / Win8 / Win10 FUNCTIONAL FEATURES: a. Mode of SMS: Text INTERFACES: 1. SIM Slot Type: Standard SIM 2. Antenna Connector: MA(F) 3. Interfacing: Either USB2.0(Type-B) or USB2.0(Type-A) provided ELECTRICAL SPECIFICATION: a. Power Supply: Working on 5V DC, either external / USB b. Dimension (l x b x h):Max. 100x55x25 mm (Make: QUECTEL or similar). Inspection by Consignee. | — | — | — | 22,03,326 | |
| — | 2.00 | — | — | ||
| Supply, Transportation, installation, testing and commissioning of Central Monitoring unit make as per RDSO specification IRS.S.99/06 specification provided in Tender document in annexure technical specification. Inspection: RDSO for supply portion, Execution: Site Engineer. | — | — | — | 7,34,658.28 | |
| — | 7.00 | — | — | ||
| Supply of Multi port Front End Processor as per RDSO spec No:S:99/2006(Amendt.3) or Latest (Inspection: RDSO). | — | — | — | 15,32,581.05 | |
| — | 7.00 | — | — | ||
| Testing and Commissioning of Multi Port Front End Processor. Inspection: Consignee. | — | — | — | 1,56,969.4 | |
| — | 25.00 | — | — | ||
| Supply of VF Tapping & Termination Transformers 2T/1120:470 Ohm as per IRSTC- 22/76 with Amd-1 or latest amendments (round type). Inspection: Consignee. | — | — | — | 57,240.75 | |
| — | 40.00 | — | — | ||
| Supply of Failure Analysis System (FAS) & failure analysis software, as per Technical Specifications.: Processor Intel Core i7 processor 12th generation or latest, RAM 16 GB, Minimum Storage 512 GB SSD, optical Mouse Standard Keyboard (USB) Mouse (USB Optical) DVD Drive 16X DVD+/-RW with Dual layer Optical Drive Modem: High speed 64K Modem or latest, offline UPS 1 KVA, LAN Network: Integrated 100/1000 LAN Ethernet, Wi-FI, Bluetooth Graphics Card: 2 GB or higher (make: Nvidia/Radeon or higher) OS pre-installed licensed software, Windows 11 Professional (Licensed Version) or latest (Minimum) with MS Office (Licensed Version), Display 27" LED (Minimum) Warranty 3 years (Minimum) Make: Lenovo/HP/DELL or Superior, . Inspection: RITES | — | — | — | 71,57,912.8 | |
| — | 40.00 | — | — | ||
| Installation, testing and commissioning of Failure Analysis System (FAS) as per Technical Specifications. Inspection: Consignee. | — | — | — | 13,56,011.2 | |
| — | 20.00 | — | — | ||
| Supply and installation of 24-40V/5ADC-DC convertor module suitable for IPS systems as per instruction of Site In charge and RDSO spec No. RDSO/SPN/ 165/ 2012 ver.3.0 or latest. (Inspection: Supply- RDSO, Installation- Site In charge) | — | — | — | 3,87,526.8 | |
| — | 40.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of single app. cases of size (1160mmx760mm) at surface and 650mm deep as per approved Drg.No.NR/S&T/CON/2-7/97. A layer of 3 mm of bitumen compound has to be provided between foundation and location box to prevent ingress of water in the base of location box. All material such as cement, coarse sand, aggregate and anchor bolt shall be supplied by contractor. App. Case single will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination. Inspection: Site Engineer | — | — | — | 2,53,542.8 | |
| — | 40.00 | — | — | ||
| Supply of single app. case steel RE with 'E' type lock and key ward no.42 and handle as per drg. No. RE/S&T/ALD/SK/219/82 with (Alt A) and 221/82 with Alt.B. Inspection: RITES | — | — | — | 8,83,006.8 | |
| — | 40.00 | — | — | ||
| Preparation of App. Case single involving wiring of relays. Preparation & fixing of bakelite hylum sheet 910x800x6mm and backelite shelf 900x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts. This includes fixing of fuses, ARA terminal, Q series relays and other type relays on square bars fixing and jamming of cables with 2-inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. Wiring description for terminal drawing of circuits, inside app. Case. Painting from outside as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specn., non-deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer. | — | — | — | 2,46,194.4 | |
| — | 75.00 | — | — | ||
| Supply, Installation & Commissioning of maintenance free earth suitable kit as per RDSO Specification no. RDSO/SPN/197/2008 and Drg No.SDO/./E&B/001 dated: - 19.09.2008 and Drg No. RDSO/SDO/. /E&B/002 dated: - 19.09.2008. Casting of cement concrete enclosures as per drg. No. (NR/S&T/CON/6.4/97). Earthing kit consisting of earthing electrode of 17mm dia as 3m long -01 no 2 MEEB (300mmx25mmx6mm) -o1 no. 3. SEEB (150mmx25mmx6mm) -01 no 4. Earth enhancing compound - 30 kg (minimum). This includes: - Provision of earth connection from MEEB to S&T equipment i.e. cable sheath, apparatus case, BPAC, Axle counter, IPS, Data Logger etc. with PVC earth wire of size 25/35 sq.mm through copper lugs of suitable size PVC earth wire shall be supplied by contractor. Note: At certain locations, it may not be possible to achieve earth resistance of less than 1.0 ohm with one earth electrode /pit due to soil resistivity. In such cases, provision of loop earth consisting of more than one earth pit shall be done, for interconnection of two earth pits copper tape of size 25x2 sq.mm shall be provided by the contractor. The number of pits required shall be decided based on the resistance achieved for the earth pits already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as separate earth. Inspection: RDSO for supply portion, Execution: Site Engineer. | — | — | — | 19,40,465.25 | |
| — | 40.00 | — | — | ||
| Supply and installation of earth electrodes as per std. practice. The item includes digging of pit in earth, 3 Mtrs. deep and fixing earth electrode pipe. Casting of cement concrete enclosures as per drg. No. (NR/S&T/CON/6.4/97). The soil treatment shall be done as per std. practice. The item includes provision. of mild steel flat of size 35mm x 6mm (as per IRSEM) and nut bolted connection of MS flat with earth electrode. The other end of mild steel flat to be connected to block instrument, cable sheath of power equipment, signal base, apparatus case, CT rack / relay racks, other equipment's as per the instruction of Engr. at site & IRSEM. Earthing connection location to location shall be done through cable which shall be provided by Railway. Complete materials such as earth electrodes as per drg. No. (NR/S&T/CON/6. 3/97), cement, wiring material, nut bolt for connection & mild steel flat of size 35mm x 6mm or 210 sqm as per SEM etc. to be supplied by the contractor. Inspection: Consignee | — | — | — | 1,22,816.4 | |
| — | 5000.00 | — | — | ||
| Supply of ARA Terminal Block 25MM center M6 terminal made of PBT as per IRS spec. No.IRS-S75/2006 (Rev.2) & IRS drawing No. SA23741A(Alt.4), SA23745(Alt.5) ,SA-23746 & SA23756(Alt.3). Inspection: RDSO. | — | — | — | 3,62,850 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender-Doc-1474.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .