Executive Engineer, PWD.,
Executive Engineer, PWD., Buildings (C and M) Division, Nagercoil.
Working Estimate for Providing Medical Gas arrangements and filling low lying area in Government Hospital at Kanniyakumari in Kanniyakumari District.
2026_PWD_715414_2
e-Tender Notice No 12 / C.8-1 / 383M / 2026-27 Dt 15.10.2026
Open Tender
Civil Works - Buildings
Lump-sum
Kanniyakumari
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹7,500
16 Oct 2026
16 Oct 2026
2 Nov 2026
16 Oct 2026
2 Nov 2026
16 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Medical Gas Copper Pipeline arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non arsenical phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (tee, elbow, reducer, coupling). The copper pipelines should be tested suitable for a steam of working pressure of 17.34 kg. / cm2 (17 bar) and confirm to BS 864 Standard with specially made for brazed socket type connection. The medical gas copper pipeline should be tested as per standard and commissioning after painting as per International Code No. IS 2379/1963 Table-V. The pipelines installed at the various wings and floors etc., complete as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. | |||||
| 1.01 | 15mm OD 0.90mm Thick Copper Pipe | 340 | RM | 544.9 | ₹1,85,266 |
| 1.02 | 10mm OD 0.90mm thick copper pipe | 20 | RM | 374.8 | ₹7,496 |
| 1.03 | 22mm OD 0.90mm Thick Copper Pipe | 21 | RM | 911.4 | ₹19,139.4 |
| 1.04 | 28mm OD 0.90mm Thick Copper Pipe | 4 | RM | 1,125 | ₹4,500 |
| 2 | DIN / BS Standard Outlet Points with from loading, inner connecting and brass body. Single press inlet with two stage process first stage for patient usage and second stage in parking mode, covered by plastic cover duly colour indicated with specific gas name and non inter-changeable for other gases. The cost of materials inclduing transport, etc., complete, as per standard specification and as directed by the Departmental Officers | 30 | Nos | 4,620 | ₹1,38,600 |
| 3 | Oxygen manifold arrangements of 2 2 banks 2 cylinder each wing with semi-automatic control panel which includes contact gauge 2 Nos., outlet pressure gauge, brass heavy duty IO x regulator 2 Nos. with suitable adopter, flexible SS Hose. Manifold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 1282-1989. Emergency alarms with illuminating display for low / high pipeline pressure and malfunctioning of system.
1) Manifold top frame with provision for connecting 4 cylinders on right bank and 4 cylinders on left bank with high pressure interconnecting copper tubing, silver brazing, non-return valve, fasteners and cylinder support middle angle frame for claping 4 x 4 cylinders and related fasteners. The O2 manifold should withstand a pressure of 140 kg. / CM
2) The installation is commissioned testing as per standards and painted as per International Code and as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. | 1 | Nos | 20,000 | ₹20,000 |
| 4 | Oxygen manifold arrangements of 1 banks x 1 cylinder each wing with semi-automatic control panel which includes contact gauge 2 Nos., outlet pressure gauge, brass heavy duty IO x regulator 2 Nos. with suitable adopter, flexible SS Hose. Manifold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 1282-1989. Emergency alarms with illuminating display for low / high pipeline pressure and malfunctioning of system.
1) Manifold top frame with provision for connecting 1 cylinders on right bank and 1 cylinders on left bank with high pressure interconnecting copper tubing, silver brazing, non return valve, fasteners and cylinder support middle angle frame for claping 1 x 1 cylinders and related fasteners. The O2 manifold should with stand a pressure of 140 kg/ CM
2) The installation is commissioned after testing as per standards and painted as per International Code and as directed by the Departmental Officers as per IS Code 12827/ 1989 & ISO 7396 / 1987 Specification. | 1 | Nos | 14,500 | ₹14,500 |
| 5 | Supplying and Fixing 4'' dial gauge adapter etc., complete, as per standard specification and as directed by the Departmental Officers . | 1 | Nos | 2,800 | ₹2,800 |
| 6 | Brass Isolation Valve suitable for the copper pipe and should be of non lubricated 90 degree turn lever ball valve of reputed make, conneced in line with medical gas pipe line system by using suitable size brass valve adopter union, ferrule, nipple, rubber O' ring, tapion lap and etc. All pipe line regulators shall be capable of controlling pipe line pressure and must compatible with the requirements specified in IS 12827-1989. All valves should be pneumatically tested for twice the working pressure for the gas line as per IS Code 12827 / 1989 & ISO 7396 / 1987 Sepecification. 15mm Isolation Valve | 8 | Nos | 1,446 | ₹11,568 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.50 MB
TD_MedicalGas_GH_750.pdf
Tender Documents • 1.29 MB
BOQ_859397.xls
BOQ • 0.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .