| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹19.4 L+₹36,497 (1.92%)Rejected-Finance | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder | |
| 3 | L3₹19.5 L+₹49,935 (2.63%)Rejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L3 | Rejected-Finance Rejected being 3rd Lowest Bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
13 Jul 2020, 6:00 pmClosed
COMMANDER WORKS ENGINEER, SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO. CWE SGNR-07 OF 2020-21 REPAIR / MAINTENANCE OF TRANSFORMER, VCBs, HT OVER HEAD LINE, HT CABLES AND ITS CONNECTED WORKS AT MILITARY STATION FARIDKOT
2020_MES_352016_1
CA NO. CWE SGNR - 07 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
FARIDKOT
Class E
Category b(ii)
10 documents required · 10 mandatory
₹500
GE FARIDKOT
₹50,000
Yes
4 Aug 2020
15 Jun 2020
15 Jul 2020
15 Jun 2020
13 Jul 2020
29 Jun 2020
Amount
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft / loose soil and making good the disturbed surfaces, complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material (soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified and directed by Engineer-in-Charge.
M&L for laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified and directed by Engineer-in-Charge.
M&L for Boring / Drilling (horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified and directed by Engineer-in-Charge.
S&F for Galvanised mild steel pipe / tubing, of size 80 mm bore, light grade complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washers complete all as specified and directed by Engineer-in-Charge.
S&F for Galvanised mild steel pipe / tubing, of size 100 mm bore, light grade complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washers complete all as specified and directed by Engineer-in-Charge.
Supply, laying, jointing testing and commissioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade of cross-sectional area 95 Sqmm, 3 core, IS 7098 marked, suitable for HT 11 KV(E) earthed system laid in trenches, in floor or fixed to pole complete all as specified and directed by Engineer-in-Charge.
Supply, laying, jointing testing and commissioning in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade of cross-sectional area 120 Sqmm, 3 core, IS 7098 marked, suitable for HT 11 KV(E) system , laid in trenches / ducts / encased in GI pipe / fixed to pole complete all as specified and directed by Engineer-in-Charge.
S & F in repair Pre-stressed cement concrete pole, 11 metre long of cross section 152mm x 152mm at top and 152mm x 260mm at bottom, class 9, complying with requirements of IS-1678-1998 errecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30 cm each in black and white colour upto 1.5 metre height from top of PCC pedestal/coping of poles and numbering of poles with synthetic enamel paint Black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint, complete all as specified and directed by Engineer-in-Charge.
S&F for stay assembly comprising of 7/10 SWG Mild steel galvanised stay stranded wire of required length fixed to pole with and including flat iron, stay clamps, bolts, nuts, galvanised stay plate 600 x 600 x 6mm thick, 20 mm dia GI stay bow (Rod) x 1.8 Mtr long , loop insulator etc.conform to IS 2141-2000 and painting to exposed surfaces of mild steel work with two coats of aluminum paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge.
S&F in repair jumper wire doble PVC bedded electric power cable (heavy duty) with aluminium conductor confirming to IS : 7098 (part 11 ) 11 KV (E) grade cross sectional area 70 sqmm single core as jumper /connecting lead on section pole of OH, GODs, HT Fuses etc. complete all as specified and directed by Engineer-in-Charge.
All as per item No 13 here-in-before but for size 50 Sqmm, complete all as specified and directed by Engineer-in-Charge.
M&L for Re-stretching of existing aluminum conductor steel reinforced (ACSR) of any size (In-situ) on over head lines fixed on insulators from 02/04 pole structure after loosening from insulators and fixing on pin, Disc insulator same with new aluminum binding wire 2mm dia complete all as specified and directed by Engineer-in-Charge. Note : Pin insulator and disc insulator shall be measured and paid separately and each wire will be measured separately.
M&L for Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the LT/HT overhead lines upto 3 metre width on each side with hacksaw/axe to clear the LT/HT line including disposal of trimmed branches 100 Metre away inside the cantonment area & clearing site complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old painted surface of 66 KV GRID Structure , fencing, gate and angle iron with connected accessories, etc and painting complete surface of installation stucture with one coat of synthetic alluminum paint - 10 Ltrs & Smoke gray - 10 Ltrs with paint brushes, writting brushes etc. enamel paint of approved colour and foundation/platform of installation painting with one coat Apex emulsion paint including writing of identification etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair, straining for replacement of GI earth wire 4 mm dia with guarding cradle on HT/LT overhead line complete all as specified and directed by Engineer-in-Charge.
M & L in replacement Heavy gang operated triple pole mechanically operated air break on load disconnecting switch each pole consist of galvanised iron base HT 11KV with polymer insulators per phase non ferrous knife and spring loaded contact GI pipe of adequate length for operation from ground level and operating handle complete in both OFF and ON position capacity 11 KV 200 Amps including taking down old one complete all as specified and directed by Engineer-in-Charge. Make : Jaipuria Brothers / National or equivalent as approved by GE
M & L in replacement 11 KV Heavy Drop Out Fuse complete in each pole consist of galvanised iron base HT 11KV with polymer insulators including taking down old one complete all as specified and directed by Engineer-in-Charge. Make : Jaipuria Brothers / National or equivalent as approved by GE
S&F for Pin type polymer insulator including one galvanised mild steel spindle two GI washers and one GI iron nut & bolt ,with hardware for 11 KV grade including dismantling the old unserviceable insulator complete all as specified and directed by Engineer-in-Charge. Make : Jaipuria Brother / National or equivalent as approved by GE
M&L for HT 11 KV Disc type insulator with hardware, single disc assembly, polymeric insulator, vitreous145mm high and 255 mm dia and socket type, including taking down old unserviceable insulator complete all as specified and directed by Engineer-in-Charge. Make : Jaipuria Brother / National or equivalent as approved by GE
S & F lightening arrestor HT 11000 KV pole mounting with polymeric insulator complete with all fittings including brackets, clamps, nuts, washers & connection , transmission class nominal discharge current upto 65 KA including removing the defective one complete all as specified and directed by Engineer-in-Charge.
Supplying, jointing and testing in replacement of heat shrinkable type end termination cable jointing kit, outdoor type, suitable for 11KV under ground earthed system 3 core XLPE cable of size 95 Sqmm including making connections complete all as specified and directed by Engineer-in-Charge.
Supplying, jointing and testing in replacement heat shrinkable type end termination cable jointing kit, indoor type, suitable for 11KV under ground earthed system 3 core XLPE cable of size 120 Sqmm to 185 Sqmm including making connections complete all as specified and directed by Engineer-in-Charge.
Supplying, jointing and testing in replacement heat shrinkable type, straight through cable jointing kit, suitable for 11KV under ground earthed system 3 core XLPE cable of size 95 Sqmm including making connections complete all as specified and directed by Engineer-in-Charge.
Supplying, jointing and testing in replacement heat shrinkable type, straight through cable jointing kit, suitable for 11KV under ground earthed system 3 core XLPE cable of size 120 Sqmm to 185 Sqmm including making connections complete all as specified and directed by Engineer-in-Charge.
Supplying, jointing and testing in replacement heat shrinkable type, straight through cable jointing kit, suitable for 11KV under ground earthed system 3.5 core XLPE cable of size 185 to 240 Sqmm including making connections complete all as specified and directed by Engineer-in-Charge.
S&F for applying petroleum jelly on GOD/ 66 KV GRID after removing carbon, dust etc complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:3:6 type C1 using 20 mm graded trap stone aggregate for repair of earth pit, cable duct PCC near GOD and transformer, etc complete all as specified and directed by Engineer-in-Charge.
M/L for PCC type C2, 1:3:6 using 40mm stone aggregates for filling and mass concrete for embedding posts of chain link fencing etc. complete all as specified and directed by Engineer-in-Charge.
M/L for PCC type B1, 1:2:4 using 20mm stone aggregates for filling and mass concrete for embedding posts of chain link fencing etc. complete all as specified and directed by Engineer-in-Charge.
M & L for filling and spreading aggregate using 40 mm grade trap stone aggregate around 4 pole , 2 pole structure, 66 KV GRID Structure and transformer etc. complete all as specified and directed by Engineer-in-Charge.
Disconnecting, dismantling and taking down carefully ACSR conductor from poles of LT/HT any size and setting a side complete all as specified and directed by Engineer-in-Charge.
S&F for stringing of Aluminium conductor steel reinforced (ACSR) conductor including binding wires of suitable size and suitable conductors / parallel grooves clamp etc other jointing materials for overhead lines of any sizes as required at site including cutting of tree branches falling on the site of work complete all as specified and directed by Engineer-in-Charge.
Dismantling / taking down old cross arms, clamps, braces etc of any section from pole including nuts, bolts, washers complete all as specified and directed by Engineer-in-Charge. Note - Cost of cutting of bolts (Slag bolts) if required shall deemed to be included in the unit rate quoted for respective item of BOQ
M&L for Mild steel cross arms, bracings, supports, clamps, and back plates fabricated from structural steel sections including nuts, bolts, washers , welding, bending, cold or hot , drilling holes for bolts , in any shape or size as indicated or directed and inclusive of one primer coat with red oxide Zinc Chrome and two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Collecting & transporting carefully the unserviceable step down transformers 11000/433 volts 3 phase 4 wire oil cooled copper/ aluminium wound of capacity 63 to 150 KVA (outdoor/indoor type) from AGE (E/M) store yard, stripping up of winding/ core to ascertain the defects/ defective parts, transporting to work shop and replacement of defective parts,, insulting materials impregnated paper, cleaning & desclaing the transformer scraping out of old paint & spray painting with superior quality smoke grey syntheic enamel paint to all exposed surface, assembling the transformers, filling dehydrated new oil complete after repairs, testing and writing MES & SM Numbers with white paint over black base in letters of height not less than 10 cm, transporting back to site from repair workshop and installing, hoisting of transformers on two/four pole sturcture at height not less than 3 meter, making all electric connetions with HT/LT side jumbers and leads including earth connections etc. and testing complete all as specified and directed by Engineer-in-Charge. Note : i) Transformers shall be got repaired form factory/ work shop. ii) The transformer shall be dismantled in presence fo contractor and MES representative/AGE E/M iii) The defective parts to be replaced shall be measured & paid for separately as supply only under respective items of BOQ iv) Safe oil container for collecting old transformer oil will be arragement by contractor. v) The T&P such as chain pulley, crane for loading unloading, transporting and for installing and hoisting shall also be arranged by the contractor at his own arrangement.
All as per Srl item No 38 here-in-before but of capacity 160 to 500 KVA etc complete all as specified and directed by Engineer-in-Charge.
Supply only in repair of defective HT/LT coil DPC copper windings strip of existing size (gauge), or cross section of winding wire corresponding to aluminium winding as per reccomendation and design of OEM grade and in weight complete with insulating material for transformers 63 KVA to 500 KVA Capacity complete all as specified and directed by Engineer-in-Charge. Make: Devidayal or equivalent as approved by GE
Supply only in repair defective HT/LT coil DPC aluminium windings strip of existing size(gauge), or cross section of winding wire as per reccomendation and design of OEM grade and in weight complete with insulating material for transformers 63 KVA to 500 KVA capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repair HT porcelain bushing including heat resistance gasket, brass spindles, nuts, bolts washers for transformers of capacity 63 KVA to 250 KVA, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of HT porcelain bushing including heat resistance gasket, brass spindles, nuts, bolts washers for transformers of capacity 400 KVA to 500 KVA, complete all as specified and directed by Engineer-in-Charge.
S&F in repair LT brass bushing including heat resistance gasket, brass spindles, nuts, bolts, washers for transformers of capacity 63 KVA to 160 KVA complete all as specified and directed by Engineer-in-Charge.
S&F in repair of LT brass bushing including heat resistance gasket, brass spindles, nuts, bolts, washers for transformers of capacity 200 KVA to 500 KVA complete all as specified and directed by Engineer-in-Charge.
S&F for silica gel breather assy including filled sillica gel complete as per size fixed for transformer of capacity 63 to 150 KVA including old unsv taking down complete all as specified and directed by Engineer-in-Charge.
S&F for silica gel breather assy including filled sillica gel complete as per size fixed for transformer of capacity 160 to 400 KVA including old unsv taking down complete all as specified and directed by Engineer-in-Charge.
M&L for top up with fresh transformer oil in transformer in-site after filtration / dehydration with minium dielectric strength of 55 KV complete all as specified and directed by Engineer-in-Charge. Make : Savita / Ascorl / Power Oil or equivalent as approved by GE
M&L for Dehydration / filtration of transformers oil of existing transformers (out door/indoor , step up/step down) / Voltage stabilizers at site by means of oil dehydration machine having arrangement for heating to remove the moisture silt/sludge and wastage removing arrangement etc to make the oil fit for use in accordance with IS-1886 to achieve minium dielectric strength of 42 KV by continoues process of dehydration complete including testing at standard gap of 2mm by oil testing machine complete all as specified and directed by Engineer-in-Charge. Note :- (i)Electricity for running dehydration machine & testing shall be provided by the deptt free of cost. (ii) Testing machine to be arranged by the contractor under his own arrangement.
Cleaning sprinkled transformer oil, grease and all other foreign materials from external surfaces of transformers of capacity 63 to 500 KVA and preparing the surface to receive paint and applying one coats of synthetic enamel paint (spray painting) including writing MES number and SM Number with white paint over black base in letters not less than 10 cms in height complete all as specified and directed by Engineer-in-Charge. Note : Painting & cleaning carried out as per location of transformer site
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade of length 2.25 metre and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 6mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. complete all as specified and directed by Engr-in-charge. Notes :- (i) GI strip upto earth test point/equipment is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement shall be 1 kg for each earth pit cover
Disconecting electric supply and strip open/dismantling carefully the existing 11 KV (VCBs) Vaccum circuit Brekers carefully at 66 KV grid Stn and testing segregating serviceble and unserviceable spare parts setting aside for re-use. After that servicing overhauling and calibration and testing of the HT panel comparising of protection and control wiring test, testing of CT's, PT's measuring and indicating instrument, earthing, over current, short circuit, insulation resistance etc, replacement of worn out wiring including bus bar insulation, applying protective kits complete all as specified and directed by Engineer-in-Charge. Note:- (i) The new spare parts required for replacement shall be measured and paid separately as Supply only. (ii) Relevent T&P and testing equipments/tools and minor accessories are arranged by the contractor and included in the unit rate of item. Make of VCB : Areva / CG / Schnieder or equivalent as approved by GE
Supply & Fix for Bushing SPOUT Set vertical type of epoxy resin with brass buss , colour red epoxy including connected of alluminium bus bar as per size - 03 Nos, for 400 A, 11 KV VCB Switch , etc with connetion complete all as specified and directed by Engineer-in-Charge. Make of VCB : Areva / CG / Schnieder or equivalent as approved by GE
Supply only for current transformer CT Ratio 100/50/5+5A of 11 KV, 15VA, Core 1, class - 0.5 complete all as specified and directed by Engineer-in-Charge. Make:-AREVA / ABB / L&T or equivalent as approved by GE
Supply only for current transformer CT Ratio 200/100/5+5A of 11 KV, 15VA, Core 1, class - 0.5 complete all as specified and directed by Engineer-in-Charge. Make:- AREVA / ABB / L&T or equivalent as approved by GE
Supply only for current transformer CT Ratio 300/150/5+5A of 11 KV, 15VA, Core 1, class - 0.5 complete all as specified and directed by Engineer-in-Charge. Make:-AREVA / ABB / L&T or equivalent as approved by GE
Supply and fixing for Auxillary switches provide remote electrical indication if the circuit breaker is open or closed. they are provided two -switch combinations, with a maximum of two switch combinations for the NF frame and six two switch combinations for the RF frame complete taking down old unserviceable switches complete all as specified and directed by Engineer-in-Charge. Make: Areva / CG / Schnieder or equivalent as approved by GE
S&F for Jaw Cluster contact rating 800 Amp , copper 99.9 % electrolite silver plated for VCB complete taking down old unserviceable jaw cluster complete all as specified and directed by Engineer-in-Charge. Make: Areva / CG / Schnieder or equivalent as approved by GE
S&F for CLOSING coil assembly voltage rating 110 V,DC of existiing specification complete all as specified and directed by Engineer-in-Charge.
S&F For TRIPING coil assembly voltage rating 110 V,DC of existiing specification complete all as specified and directed by Engineer-in-Charge.
S&F for multifunction meter conserv EM 6400 complete taking down old unserviceable multifunction meter complete all as specified and directed by Engineer-in-Charge. Make: Areva / CG / Schnieder or equivalent as approved by GE
S&F for Master Trip Relay , BR1231387, 110 Volt DC Supply complete taking down old unserviceable master trip relaycomplete all as specified and directed by Engineer-in-Charge. Make: Areva / CG / Schnieder or equivalent as approved by GE
S&F For Ammeter ALPHA A , as per size complete taking down old unserviceable Ammeter ALPHA A complete all as specified and directed by Engineer-in-Charge. Make: Areva / CG / Schnieder or equivalent as approved by GE
S&F for TNC Switch , three position switch , as per size complete taking down old unserviceable TNC Switch complete all as specified and directed by Engineer-in-Charge. Make: Areva / CG / Schnieder or equivalent as approved by GE
S&F for Segment gear for 11 KV Mechanism Assembly, as per size complete taking down old unserviceable segment gear complete all as specified and directed by Engineer-in-Charge. Make: Areva / CG / Schnieder or equivalent as approved by GE
S&F for Z Switch , Z type switch , Micro limit , 11 KV Windsor as per size complete taking down old switchs complete all as specified and directed by Engineer-in-Charge. Make: Areva / CG / Schnieder or equivalent as approved by GE
M&L for HT self fusing insulation tapes (without compound) of size 38 x 0.76 mm, 10 m long for VCB Bus bar insulation complete including taking down old to disposal off complete all as specified and directed by Engineer-in-Charge. Make: Scapa or equivalent as approved by GE
S&F for spray of Anti Track coating compound spray - 320, brick Red colour complete all as specified and directed by Engineer-in-Charge. Make: MOSIL Lubricants or equivalent as approved by GE
S&F in repair power pack 240 Volts AC/24 Volts DC supply suitable working on tripping system complete all as specified and directed by Engineer-in-Charge. Make : Maha Mai Engineers or equivalent as approved by GE
Supplying, installing, testing of Comperhensive numerical protection relay : Model Type : CGI 14N Relay 110V DC, Designation of relay : CGI 14N, Numerical Non - communicable FP IDMTL+INST 3O/C+ 1E/F Relay flush mounted type, Over current IDMLT setting - 5% to 200% of CT secondary, Earth fault IDMTL setting - 5% to 200% of CT secondary, instsntanious Over current setting 50-1600%in step of 1% complete all as specified and directed by Engineer-in-Charge. (A) Having the following additional facilities :- (i) Trip ckt supervision (ii) Disturbance recorder (iii) Event log with date and time. Make :- CG / Schneider or equivalent as approved by GE
M&L for flash over carbon cleaning kit consisting of CRCA Super Gasket Remover-400ML- 02 Nos, CRC LECTRA CLEAN-400 ML-04 Nos for cleaning of carbon deposited due to flash over on bus bars and insulators complete all as specified and directed by Engineer-in-Charge. Make: Hy poxy or equivalent as approved by GE.
M&L for moisture removing cum protection Kit consisting of CRC-2-26-500ML 06 Nos, LECTRA CLEAN-400 ML 06 Nos complete all as specified and directed by Engineer-in-Charge. Make: Hypoxy or equivalent as approved by GE
M&L for CT/PT/PCB protection Kit consisting of CRC Plastic-70-400ML- 12 Nos, which is moisture and acid proof protects equipment from moisture and acidic fumes complete all as specified and directed by Engineer-in-Charge. Make: Hy poxy or equivalent as approved by GE -------------------------------------------------------------------------------------------------------------- Note : A sum of Rs. 1,69,415.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 28 & 29 (Schedule of Credit) of Tender document
GILL ENTERPRISES
Singla Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .