| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 LAccepted-Finance BY LANE NUMBER HOUSE NO 2 SATGAON BAZAR PO UDAYAN VIHAR GUWAHATI 781171 ASSAM | KAMRUP METRO | ASSAM | 781171 | ₹1.0 L | L1 | Accepted-Finance L1 |
| 2 | L2₹1.0 LRejected-Finance | ₹1.0 L | L2 | Rejected-Finance L2 |
| 3 | L3₹1.0 LRejected-Finance | ₹1.0 L | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | DAS ELECTRICAL ENGINEERING CO L2 | PRADIP DEY L3 | DAS & CO L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & Delivery of following LED Industrial Batten light (System lumen efficacy 2110 Im/Watt) made of CRCA Sheet Body (Thickness > 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap), Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range Oo to 400 C, internal surge protection of 2.5 KV with Short & Open circuit protection . ITHD < 10% , P. F.20.95, P20, CRI >80, Flicker free, (Ricker should be below 5%), life time (LED, Driver & electrical circuitary), of minimum 40000 Burning Hours, with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FR/FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 3 year OEM warranty. LM79 & LM8O Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90 ° C) Double Batten Fittings (2 x 18/20 Watt) | 4 | Nos | 1,480 ₹5,920 | 1,485 ₹5,940 | 1,475 ₹5,900 |
| 2.00 | Supply & Delivery of 240V, 18/ 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] | 6 | Nos | 460 ₹2,760 | 465 ₹2,790 | 456 ₹2,736 |
| 3.00 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. | 4 | Set | 265 ₹1,060 | 265 ₹1,060 | 260 ₹1,040 |
| 4.00 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy.fittings as required. 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC | 95 | Mtr | 135 ₹12,825 | 135 ₹12,825 | 134 ₹12,730 |
| 5.00 | Do….....Do...2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC | 125 | Mtr | 155 ₹19,375 | 160 ₹20,000 | 156 ₹19,500 |
| 6.00 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC | 20 | Mtr | 645 ₹12,900 | 648 ₹12,960 | 645 ₹12,900 |
| 7.00 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. 25mm size | 40 | Mtr | 91 ₹3,640 | 100 ₹4,000 | 90 ₹3,600 |
| 8.00 | S&D 6A Modular type 5 pin Plug Socket | 40 | Nos | 140 ₹5,600 | 143 ₹5,720 | 138 ₹5,520 |
| 9.00 | S&D 16A Modular type 6 pin Plug Socket | 41 | Nos | 192 ₹7,872 | 196 ₹8,036 | 193 ₹7,913 |
| 10.00 | S&D 16A Modular type Switch | 1 | Nos | 140 ₹140 | 155 ₹155 | 136 ₹136 |
Tender Value
Refer Docs
EMD Value
₹2,060
Closing Date
27 Jan 2026, 12:30 pmClosed
Assistant Engineer, PWD
Alipurduar Electrical SD
Emergent Electrical installation work at Morgue, Labour room, Male and Female Medicine ward, HCCU, NRC etc in the District Hospital Alipurduar.
2026_WBPWD_990523_1
WBPWD/AE/AESD/eNIT-23/2025-26
Open Tender
ELECTRICAL WORKS ORG
7 days
Alipurduar DH
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,060
Alipurduar Electrical SD
27 Mar 2026
19 Jan 2026
29 Jan 2026
19 Jan 2026
27 Jan 2026
21 Jan 2026
21 Jan 2026
Supply & Delivery of following LED Industrial Batten light (System lumen efficacy 2110 Im/Watt) made of CRCA Sheet Body (Thickness > 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap), Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range Oo to 400 C, internal surge protection of 2.5 KV with Short & Open circuit protection . ITHD < 10% , P. F.20.95, P20, CRI >80, Flicker free, (Ricker should be below 5%), life time (LED, Driver & electrical circuitary), of minimum 40000 Burning Hours, with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FR/FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 3 year OEM warranty. LM79 & LM8O Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90 ° C) Double Batten Fittings (2 x 18/20 Watt)
Supply & Delivery of 240V, 18/ 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy.fittings as required. 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Do….....Do...2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. 25mm size
S&D 6A Modular type 5 pin Plug Socket
S&D 16A Modular type 6 pin Plug Socket
S&D 16A Modular type Switch
S&D 6 module Cover plate
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. [Make: Legrand/ ABB/ SIEMENS/ Schneider/ L&T] 40 A, DP
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. [Make: Legrand/ ABB/ SIEMENS/ Schneider/ L&T] 4 Way
Supply & Delivery of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 45o C, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66, IK-7, CRI >70 , under voltage and over voltage protection, EMI- EMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FR/FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). System lumen efficacy ≥110 <135 lm/Watt (IK-8) 100 Watt
S/D 25A contractor with 2NO 1Module) Make L&T Cat No - AUMC2OO2501)
S/D Daily Weekly Programamable Electronic Digital Crono Timer Switch cat no Gic L&T 67DDTO (2 Module)
Note:- Labour welfare Cess @ 1% and GST @ 18% on Bill amount will be deduct.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Tendernotice_2.pdf
PDF • 0.50 MB
BOQ_2421435.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid