Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
13 Jul 2026, 3:00 pm
Similar tender results from the same govt authority in the past 3 years.
Electrical work in connection with "Prayagraj Provision of concrete levelled track on Line No. 22, 23, 23A, 24 & 25 and 120m examination pit on Line No. 23A in PRYJ coaching yard".
ELG-31-2627
ELG-31-2627
Open
6 Months
Prayagraj, Uttar Pradesh
₹0
₹1.5 L
19 Jun 2026
19 Jun 2026
29 Jun 2026
Item Breakup - 1-NS Schedule
Supply, replacement, fixing, testing, connectingandcommissioning of Numbers 250 Watt or above LED flood light fittings asper IS:10322. LEDLuminaries:-(1) A complete LED lighting unitconsisting of alight source and driver together with parts ofdistribute lights,to position and protect the light source, and toconnect the lightsource to a branch circuit.The light source itselfmay be an LEDarray and LED module, or an LED lamp.(2):-Supplied LEDluminaries shall confirm to IS:16101 (2012)IS:16106(2012). Light Source (LED) in the Luminaries should beofmake:- (1):-NICHIA/CREE/OSRAM/ SEOUL/PHILIPS/LUMILEDS/LEDNIUM. (2):-LEDs toIS:16105(2012).IS:16108(2012),IEC:62471.Type LED:- Highpower LED,SMD(Surface Mounting device)/COB(Clip on board). 1.Input operatingvoltage :-105-295 V AC. 2:- NormalVoltage-220V AC, 3.Drivertype: constant current driver withshort circuit protection. 4. LEDlife:- >=50000 burninghours.5.Depreciation:- 30% max. after50000 burninghours.6.Control of distribution:- Full cut off.7.Surgeprotection: 4KV. 8. Drive component :Industrialgradeonly. 9. Efficiency of driver electronic: > 85%. 10.Beamangle:>=140 degree along with road and >=80 degreeacrossthe road. 11.Colour temperature: 5000-6500K.12.Colourrendering index (CRI):>=75. 13. Ingress protection :IP-66. 14. Lumen output: >=120 lumens/watt. 15. Power factor:->=0.95. 16. Total harmonics distortion(THD):-<15%. 17.Lampcover :Toughened glass or UV stablised polycarbonate. 18.Finishing:Power coated /Anodized. 19.Secondryoptics :polycarbonate reflector/ poly carbonateslens. 20. Construction ofhousing: extrudedaluminum/CRCA/Pressure die castaluminum.21. Mounting: Suitable for existing pole/Truss/Lanternmounted.22. Certificate:Firm to submit LM 80 (In respect of LEDused) &LM79(In respect of luminaire used) test certificatefromNational/International accredited Laboratory and OEM certificate for compliance of BIS/IEC. 23. Warranty: Firmtosubmit warranty certificate for five year along with the supply.All fittings shall be fitted with new suitable bend/elbow withclampand proper nut and bolt and connection with twisted twinflexiblecord of minimum size 16/1 mm copper conductor as perrelevanttechnical specification. Material parameters must remainunchanged during entire warranty period.Inspection by- RITES. PRAYAGRAJ DIVISION-ELECTRICAL/NORTH CENTRAL RLY
Supply, erection, testing, connecting &commissioning of 20 meter Numbers high mast systemcomplete with all accessories 16 nos. luminaries of 200W LED each Light, including making offoundation as per recommendation of manufacturesalong with required materials for making offoundation and with feeder pillar including allaccessories. 20 M high mast with its accessoriesMast shaft shall be hot dip galvanized (Singledip)comprising of polygonal pole and welded baseplate hot dip galvanized head frame with clamps,nuts & bolts for fixing sixteen luminaries and CGbox etc.(01 Job) A rising & lowering mechanismwith winch Lenten carriage head frame, SS wire,Rope cable &power tools with 1.5 HP motor. (1Job). Supply,erection, testing, connecting andcommissioning of16 nos. luminaries of 200W LEDincluding allaccessories. (01Job). Supply of M30foundation bolts of size-850mm manufactured fromspecial steel C/W nuts, washers anchor plates &template for above mast including earthingarrangement with electrode of 40 mm dia "B" classGI pipe of 3.0 mtrslong as per Drg. No. SrDEE/G/ALD 10/94. (01 Job).Construction ofsuitable shallow foundation with M20 gradeconcrete for 20M high mast considering the SBC as10/T sqmtr at 2 mtr depth with all materials &labour (01 Job). Supply of twin domeaviationobservation light with 2 Nos LED array lamp. (01set) Supply & installation of separate control panelin front of feeder pillar housingsuitable controlcircuit with timer & AVR for theoperation of themast. It shall also consist of suitable control for the power tool motors with suitable foundation.Inspection by- RITES.
"Supply, erection, testing, connecting and commissioning of 500KVA Numbers 11/.415V CSS with 1. 11KV 3 Way RMU (2 Nos LBS + 1 No VCB with Transformer Protection Relay ) 2.11/.415V 500KVA Oil type Transformer with OCTC 3. I/C 800A 4P 50KA MDO ACB With MP Based O/C , S/C & E/F Release - 1 No. I/C 800A 4P 50KA MDO ACB With MP Based O/C , S/C & E/F Release - 1 No. O/G 630A 4P 50KA MDO ACB With MP Based O/C , S/C & E/F Release - 3 Nos. 4. 800A Aluminium Bus Bar."Inspection by- RITES.
Design, Supply, fixing, testing and commissioning of outdoor type Numbers front operated double door weather proof feeder pillar having IP 65 protection (MCCB - Incoming & MCCB - Outgoing) comprising with the following MCCB's fixed in it of make Havells, Siemens, L&T, Schneider, Legrand or equivalent conforming to IEC 60947-2 / IS 13947: 2008 & IS 8623:2008 or latest with digital measuring instrument & bus-bar arrangement confirming to PCEE'NR's spec No. PCEE/NR/126-Elect/PS/2019 at Tech Spec-VI and as per IS, IE rules and site requirement. 160A Microprocessor MCCB 4P 36 kA = 01 No. (Incoming) 63A Microprocessor MCCB 4P 36 kA = 04 No. (outgoing).Inspection by- Consignee.
Supply, erection, testing andcommissioning of single earth electrode Numbers of 50 mm. dia 4000mm long GI pipe class Bcomplete with earth box with CI coverhinged to CI frame including connectionfrom earth electrode toMDB/SDB/poles/with 8 swg GI wire/stripas per attached drawing.Inspection by-Consignee.
Collecting, Transporting from SSE/PS/store to site, laying, testing, Metre andcommissioning of above LT cable . Layingdirect in ground (Including excavation,sand cushioning, protection brick coveringand refilling the trench etc.), direct inRCC/Metal pipes in rod/track crossings andon surface/required in wall/in concretefloor by cutting recessed and finishedoriginally as required as per relevanttechnical specifications.
Termination of LT XLPE cables of varioussizes (One Job means all 4 Numbers cores ofcables).Inspection by- Consignee.
Drilling of bituminous road/track and layingcharges of cable in road Metre crossing for laying110 mm dia HDPE pipe through it.
Supply and laying of HDPE Pipes (Upto PN8.0 Pressure Rating Material Metre Grade: PE 63,Pressure Rating: PN 8.0, NominalDia(mm): 110) as per IS-4984:2016suitable for HT/LT XLPE cable & as requiredand as per relevant technicalspecification.Inspection by- Consignee.
Wiring for circuit / sub mainwiring along with earth wirewith the Metre following sizes of FRLSPVC insulated copperconductor, single core cable insurface/recessed PVC conduitas required. 2 x 4 sq. mm+ 1 x4 sq. mm earth wire..Inspection by- Consignee.
Supply, Erection, Testing andCommissioning of followingModular Type Numbers switch 10 A (1-way) complete in all respect.Inspection by-Consignee.
Supply, Erection, Testing andCommissioning of followingModular type Numbers Plug socket outlet2/3 Pin 10 A complete in allrespect. Inspection by- Consignee.
Supply and Erection of whitefinish single mounting coverplate with Numbers base frame suitable8 module suitable for mountingof Modular type pianoswitches/ plug Socket, fanregulator and connection towiring. Inspection by-Consignee.
Supply and Erection of ModularMetal boxes concealed Boardssuitable Numbers for mounting of 8module white finish singlemounting cover plate withFrame and Modular type pianoswitches/ plug Socket, fanregulators. Metal board boxesare to be concealed in wall.Inspection by-Consignee. PRAYAGRAJ DIVISION-ELECTRICAL/NORTH CENTRAL RLY
Supply, erection, testing andcommissioning of One phasedistribution Numbers board comprisingof one no. 32/40 amps DP MCBwith 40 A ELCB/RCCB asincoming and 4 nos. 10 ampsSP MCB , 4 nos. 20 A SP MCBas outgoing complete withcopper bus bars, neutral linkand other accessories housedin CRCA sheet enclosure withdouble door type. Inspection by-Consignee.
Supply, fixing, testing andcommissioning of wall mounteddistribution Numbers board (TPN MCB -Incoming & SP MCB -Outgoing), made up of steelsheet, phosphatised powerpainted complete with neutrallink, earth point, Din railconforming to IS:13032 &8623 of reputed make withfollowing items of matchingmake to be fixed in distributionboard confirming to IS:8828:1996 or latest, IE rules andsite requirement. TPN MCB 63Amps 10kA "C" series = 01Nos. (incoming) SP MCB 6- 32Amps 10kA "C" series= 18Nos. (outgoing). Inspection by- Consignee.
Supply, fixing, testing andcommissioning of DP RCBO's10 (2P, 30 mA) Numbers Amp out going confirming to IS: 12640-2,IEC-61009-1 or latest. Inspectionby-Consignee.
Supply of PVC insulated multistranded copper conductorsingle core Metre HRFR cable 1.5 Sq.mm conforming to IS: 694(latest version), and drawing inlaid (recessed /surface) PVCconduit pipe for Earth wire asrequired as per technicalspecification including connections, testing and commissioning.Inspectionby-Consignee. Total 7264865.94
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022_2022__27_04_227.pdf
ATTACHMENT
2022_12_13RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril2022ACSNo_2.pdf
ATTACHMENT
2023_04_26RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_3ACS-3113.pdf
ATTACHMENT
2023_08_07RBCE_CE-I-CTIndianRailwayStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_4ACS-4.pdf
ATTACHMENT
2023_10_20RBCE_CE-I-CTIndianRailwayStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_5ACS-5.pdf
ATTACHMENT
2023_12_21IndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_6ACS-6.pdf
ATTACHMENT
2024_05_14ClarificationregardingsubmissionofAnnexure-VofGCC.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
AnnxVIB.pdf
ATTACHMENT
GCCACS2022CORRECTION1.pdf
ATTACHMENT
Likelysourceofsupply.pdf
ATTACHMENT
TNDoc.pdf
ATTACHMENT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_111.pdf
ATTACHMENT
Download all tender documents and submit your bid