Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.3 LAccepted-AOC | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹48.1 L+₹2.1 L (4.66%)Rejected-Finance VILL P O MANKAR DIST BARDHAMAN PIN 713144 | MANKAR | BARDHAMAN | WEST BENGAL | 713144 | L2 | Rejected-Finance Higher rate quoted | |
| 3 | Rejected-Technical 84 B LOWER BURDWAN COMPOUND RANCHI 834001 JHARKHAND | RANCHI | JHARKHAND | 834001 | - | Rejected-Technical Recommended as No in the WLR for the QE Jun 2021 by HQEC |
Tender Value
₹49.2 L
EMD Value
₹98,400
Closing Date
27 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2021_MES_483512_2
8400-697/E8
Open Tender
Civil Works
Works
180 days
PANAGARH
Class D, Cat a (i)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹98,400
Yes
4 Jan 2022
29 Nov 2021
29 Dec 2021
29 Nov 2021
27 Dec 2021
13 Dec 2021
60 days
Amount
Dismantling asbestos cement (corrugated/ semi corrugated etc) sheet in roof covering complete all as specified and directed.
S&F 0.50 mm thick Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering in ridge/cladding to wall, fixed with self tapping screws as specified and as directed.
S&F wind ties for roof including securing bolts, flat iron fillets (for securing weather boarding with screw bolts and nuts) including all necessary drilling,bolting or riveting, etc and similar work conforming to Fe 410-0 or Fe 310-0 including painted with one soap coat of zinc chromate primer paint. (including preparation of surface at contractor's workshop before fabrication) complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing to low lying area and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete (un- reinforced) not exceeding 15 cm thickness (above or below ground level) complete all as specified and directed.
Demolition of RCC(other than ground floor) pillar, beams landing, chajjas, slab shelves & similar suspended work (reinforcement cut as required to facilitate demolition) and removing unseviceable material complete all as specified and directed
Surface dressing n exc 15 cm deep in soft /loose soil complete all as specified and directed.
M&L for moorum/red bajri filling in floors or in foundation, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for hardcore of gauge n exc. 63mm, deposited, spread and leveliled in layers n exc. 150mm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100mm thick Cement concrete type B- 2,1:2:4 (using 40mm graded stone aggregate) as in subbase of floor complete all as specified and directed.
M&L for 100 mm thick PCC type C-2, 1:3:6 (using 40 mm graded stone aggregate) finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for 25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in floor for levelling course complete all as specified and directed by Egineer-in-Charge complete all as specified and directed.
M&L for Non - skid Ceramic Coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry over screed bed or bedding layer of 15 mm thick with cement mortar 1:6 and pointed in white or coloured cement to match complete all as specified and directed. (Make: M/s Kajaria / M/s Somany/ M/s Johnson India).
All as per item No 13.00 as mentioned here -in-above but in skirting/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. (Make: M/s Kajaria / M/s Somany/ M/s Johnson India).
M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles over 10mm thick rendering in cement mortar 1:4 complete all as speciified and directed. (Make: M/s Kajaria / M/s Somany/ M/s Johnson India).
Dismantling wall and ceiling board of any descrition complete all as specified and directed.
S&F anodised aluminium snap grid frame work size of grid 605 x 605 mm for false ceiling complete all as specified and directed.
S&F hangers 6mm di GI (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40x 3mm size 60mm long and expansion hold fteners 12.5 mm dia, 40 mm long complete all as specified and directed.
S&F 6mm thick non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/Aluminium framework with screws as in ceiling complete all as specified and as directed.
Dismantling timber scantlings 40 sq. cm and over in section in unframed work, in any position complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling framed trusses n.exc 10 m span complete all as specified and directed.
Errection fixing only Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
Taking down cement plaster of any description on concrete surfaces such as soffit of chajjas and brick walls etc incl raking out joints, hecking for key scrubbing down with water and removal of rubbish off the premises complete all as specified and directed
M&L for rendering 10 mm thick cement plaster in cement mortar (1:6) on brick work or concrete surfaces including finished even and smoothh without usig extra cement complete all as specified and directed
M&L for rendering 15mm thick in CM 1:4 using liquid waterproofing compound as per manufacturer instruction on fair faces of brick work or concrete surfaces complete all as specified and directed. Note : (WPC will be measured and paid separately)
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete wall surfaces & finishing the surfaces fair and even complete all as specified and directed.
M&L for rendering 20 mm thick cement plaster in CM 1:6 on external fair faces of brick/concrete work surfaces finished even and smooth (without using extra cement) incl WPC (WPC will be measured and paid separately).
M&L for rendering 5 mm thick in CM 1:6 on fair faces of brick work or concrete wall surfaces & finishing the surfaces fair and even on ceiling complete all as specified and directed.
Supply only Liquid water proofing compound complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying a layer of wall care putty and two coat of oil bound distemper complete all as specified and directed. (Make: M/s Tractor Acrylic Distemper of Asian/M/s Bison Acrylic Distemper of Berger, M/s No 1 Premium Acrylic Distemper of Shalimar)
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint (exterior weather proof) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior weather coat paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. (Make: M/s Apex Ultima of Asian/ Weather Coat all guard of Berger/Xtra Tough of Shalimar)
M&L for preparation new plastered surfaces and applying three coat of white washing on ceiling complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressedstonework and precastconcrete articles complete all as specified and directed
M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete, all as specified and as directed.
M&L for brick work using old size bricks (except Bricks) straight or curved on plan exceeding 6.00 Meter mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brick work with flyash bricks straight or corve on plan to any radius in half bricks thick walls, built in cement mortar (1:4) complete all as specified and directed.
M&L for Plain Cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) in surface channels and drains complete all as specified and directed.
M&L for plain cement concrete type B0(1:2:4) using 12.5mm graded stone aggregate as in coping complete all as specified and directed.
M&L for Setting coat of 3mm thick of CM (1:2), trowelled to even and smooth finish over rendering 15mm thick in CM 1:4 on fair faces of brick work finished surface even & smooth with using water proofing compound @ 2% complete all as specified and directed.
Taking down chowkhat or frame with shutters n.exe 1.50 Sqm (without taking of shutter from frame ) each complete all as specified and directed.
Taking down chowkhat or frame with shutters exe 1.50 Sqm and not 4 sqm (without taking of shutter from frame ) each complete all as specified and directed.
Supply and fix Steel windows with side hung shutters (minimum wt. of steel section should be 1.42 kg/M) including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
All as per Item No 40.00 mentioned here-in-before but with out glazing bars complete all as specified and directed.
M&L for framed work such as grills etc with endsof bars shouldered nd or riveed or forged into spike, framed guard bars and similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed.
Supply and Fix Steel ventilators with centre hung shutter (minimum wt. of steel section should be 1.42 kg/M) including two pairs of brasscup pivots, catch spring and pulleywheel, complete dovetailed or welded including pintol hinges, steel handles, etc. as shown with fixed type complete all as specified and directed.
M&L for two coats synthtic enamel paint over a coat of red oxide primer on new steel surfaces incl preparation of surfaces over 10 cm width or girth complete all as specified and directed.
M&L for two coats synthtic enamel paint over a coat of red oxide primer on old steel surfaces incl preparation of surfaces over 10 cm width or girth complete all as specified and directed.
M & L for 3mm thick plain sheet glass ordinary quality & glazing with oil putty n.exc 0.50 Sqm in each pane complete all as spd and directed by Engr-In-Charge .
S&F stainless steel wire cloth of 0.36 mm nominal dia of wire and averaging of width of aperture 1.40mm, fixed with stainless steel wire staples including taking out old wire cloth complete all as specified and directed.
M&L for Chowkhat 2nd class hard wood and frames wrought , framed rebated on the solid rounded or chamfered, put together with gluepinned at joints complete all as spd and directed by Engr-In-Charge.
S&F Anodised aluminium powder coated (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
S&F anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
S&F door closer aluminium body, hydrailically regulated, designation No.2, universal type, suitable for door shutters and weight between 36 to 60 kg and fixed complete all as specified and directed.
S&F floor door stopper over all length of cover plate 140mm of aluminium alloy body with rubber shoe and tongue, anodised, with hard drawn steel spring and fixed complete all as specified and directed.
S&F mortice lock vertical type 100mm 4 lever brass fixed in luminium door complete all as specified and directed.
S&F 35mm thick 2nd class hardwood, factory made plain framed, panelled shutters (two panel), with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS :1003 (Part I), kiln seasoned and chemically pressure treated complete all as specifiedd and directed by Engr-In-Charge.
S&F 35mm thick 2nd class hardwood glazed & skeleton shutters, open repeated & prepared to received glass gauze etc. (without sash bars) edges of framing plain for securing glass etc, fitted to chawkhats complete all as specifiedd and directed by Engr-In-Charge .
S&F Mild steel flat iron 25x6mm as in hold fasts including all necessary cutting etc complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in bed block for fixing of hold fasts etc complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described treating ends of posts, backs of chowkats, etc., area tarred exc 0.1 sq. m but n exc 0.5 sq. m each and treated with tar or coal tar black paint complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described treating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats, etc.,area n exc 0.1 sq. m each and treated with tar or coal tar black paint complete all as specified and directed.
M&L for painting on new wooden based surfaces of any description not other wise described over 10cm width or girth applying two coat synthetic enamel paint over one coat of pink primer including preparation of surfaces complete all as spd and directed by Engr-In-Charge .
S&F Mild steel sliding door bolts 300mm long, plate type stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and two on staple plate and fixed complete all as spd and directed by Engr-In-Charge.
S&F mild steel ordinary rat tail rod pattern spring 300mm including roller and roller plate on wooden/steel choukhat including welding, riveting etc complete all as specified and directed by Engr-in-Charge.
S&F 2nd class Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 cu. cm each all as specified and directed by Engr-in-Charge
S&F 200mm Mild steel barrel tower bolts, stove enamelled black, with bright bolt complete all as specified and directed.
S&F 125mm Cast iron or malleable cast iron handles, cast type, stove enamelled black complete all as specified and directed.
S&F stainless steel butt hinges, medium weight, and fixed with screws or with welding to existing MS frames, 100 mm size, ISI marked, complete all as specified and directed.
S&F in repairs MS drapery rod of 25mm dia of PVC coated in curtain rod complete all as specified and directed.
S&F MS PVC sheeted/powder coated bracket size 150mm made to shape suitable for holding curain/draprey rod of 25mm dia fixed with PVC rawl plugs and MS steel screws for single/double rods complete all as specified and directed
S&F for coloured conical end balls dia not less than 50mm and PVC coated made to shape suitable for fixing as end of curtain/drapery rods complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
All as per iem No. 71.00 mentioned here-in-above but exc 1.5 m depth beyond the first 1.5 m complete all as specified and directed.
Returning, filling in and including spreading, leveling, watering & well ramming in layers n.exceeding 25 cm in soft/loose soil complete all as specified and directed.
Removing of excavated materials to a distance n. exc 50m and depositing where directed at a level n exc 1.5m above the starting point in oft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil complete all as specified and as directed.
M&L for PCC type D2, 1:4:8 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
M&L for Reinforced cement concrete (nominal mix) type B1(1:2:4) (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M & L for reinforced cement concrete (design mix) M-25 in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for Reinforced cement concrete (nominal mix) type B1(1:2:4) using (using 20mm graded stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for Reinforced cement concrete (nominal mix) type B1(1:2:4) (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for reinforced cement concrete(Nominal Mix) type B-0 (1:2:4) (using 12.5 mm graded stone aggregate) as in chajjas and similar work complete all as specified & directed by Engineer in Charge.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finihed surfaces complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams for rough finished surfaces etc complete all as specified and directed.
Use and waste of form work to chajja and similar work including edges ffor rough finished surfaces complete all as specified and directed.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work for rough finished surface, not exceeding 200m thick (Horizontal or sloping) complete all as specified and directed.
S&F Mild Steel TMT bars 10mm and over, cut to lenghth, bent to shape requird, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clip complete all as specified and directed by Engineer in Charge.
All as per item No 82.00 as mentioned here-in-above 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
S&F Sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160 mm complete all as specified and directed.
S&F vitreous china wash basin, white, flat back, size, 550X400mm including bracket for fixing 32 mm waste coupling, waste pipe etc complete all as specifid and direted.
S&F in repair PVC waste pipe 32mm dia for wash basin and sink 01 mtr long complete all as specified and directed
S&F in repair Pillar taps, 15mm bore, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'HOT or COLD' with long scrwed shanks and fly-nuts, screwed for iron pipe or for connection pipe complete complete all as specified and directed.
S&F in repair bib taps of 15mm bore fancy type, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair stop valve of 15mm bore , chromium plated with long shank and cup concealed type cast copper alloy, screwed down, high pressure, with crutch handle, screwed both ends for brass ferrule complete all as specified and directed.
S&F in repair 32 mm bore Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm45gms/ 40mm-60 gms complete all as specified and directed.
S&F in repair 40 mm bore Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm45gms/ 40mm-60 gms complete all as specified and directed.
S&F in repair PVC connection 15 mm size PTMT nuts of length ength 600 mm complete all as specified and directed
S&F in repair grating square 150mm size of PTMT (minimum weight 100 gms) complete all as specified and directed.
Taking down rain water pipes (any size or pattern) , including all fittings and removal off the site complete all as specified and directed.
S & F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall with clamps and jointed complete all as specified and directed by EIC.
S&F CP tubular towel rail 20mm dia D type 60CM between two flanges complete all as specified and directed by Engineer -in-Charge
Taking up or down 15mm dia bore steel tubing and connection including cleaning for refixing or remove to store complete all as specified and directed.
S&F 15 mm dia bore steel tubing medium grade galvanised with all fittings and connection complete all as specified and directed.
Taking up or down 20 mm dia bore steel tubing and connection including cleaning for refixing or remove to store complete all as specified and directed.
S&F 20 mm dia bore steel tubing medium grade galvanised with all fittings & connection complete all as specified and directed.
M&L for 100mm thick Cement concrete type C- 2,1:3:6 (using 40mm graded stone aggregate) as in subbase complete all as specified and directed.
M&L for chequered cement concrete coloured tiles of size 30 cm x 30 cm x 25 mm thick, set jointed and pointed in neat cement slurry ( with grey cement and pigment) after and including 20mm thick screed bed in cement mortar (1:6) for fixing tiles compplete all as specified and directed.
M&L for 75mm thick Cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in plinth protection complete all as specified and directed.
Extra for fair finish drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms moulds, mitred/stopped ends etc cmplete all as specified and directed by Engr-in-Charge
Taking down carefully copper/aluminium conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified.
M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
M&L for wiring for socket out let on independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified.
All as per item No 111.00 mentioned here-in-above but 5 Amp socket on same board with other switches complete all as specified and directed.
M&L for wiring for socket outlet 3 pin, 15 amps on independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified.
S&F Bell push, flush type, 5 amp complete all as specified and directed.
S&F Buzzer, Ding dong, AC 230 Volts, single pole 230 volts all as specified and directed.
S&F switch piano flush type, single pole , 6 Amps, one way complete all as specified and directed.
S&F switch socket combination, 2 in 1 multipurpose 5 pin, (6 Amps ) complete all as specified and directed.
S&F Socket outlet 3 pin, 5A, flush type complete all as specified and directed.
S&F switch Socket combination 16 Amps flush type controlled by one switch complete all as specified and directed.
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed.
S&F stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified and directed.
S&F lamp holder, PVC/polycarbonate type with back plate straight or anfular suitable for batten fittings complete all as specified.
S&F LED bulb 7 watts, 240 volts, ISI marked complete all as specified.
S&F exhaust ventilation fan of sweep 400mm with louvers,240 volts, metalic body, BEE 5 star rated, ISI marked complete all as directed by Engr-in-Charge.
S&F in repair recessed mounted 2' x 2 ' LED luminaire 36 watts for grid ceiling minimumm lumen output 100 lumen/Watt, pre-treated CRCA frame powder coated with diffused Profied including necessary connection complete all as specified and directed.
S&F power unit, 25 Amps, ISI marked, 240 Volts complete all as specified.
S&F in repair wall mounted type decorative LED light with LED 9 watts bulb , 50Hz complete with all accessories complete all as specified and directed.
S&F GI pipe light grade 40 mm dia of size for road cross of cable,ISI marked all as specified and directed.
S&F XLPE insulated armoured cable, 25 sqmm 4 core,1100 volts grade heavy duty cable,ISI marked passing through pipe, with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed complete all as sepcified. Note : (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (ii) Cable Route Indicator made of metal of height 300mm above GL duly written ''LT CABLE'' to be fixed on every 30 mtr distance with pcc (1:3:6), 150 mm below the GL ,cost of indicator and pcc to be considered in this item rate.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (Note : Punned thickness shall be measured).
M&L for sub class B bricks locally available of size 25 x 12.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed.
S&F two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked), concealed, including 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed.
S&F two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC conduit (ISI marked), concealed, including 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed.
S&F 20 W LED batten light fittings with extruded polycarbonate complete with all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete, complete all as specified and directed.
S&F security light fittings 25 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. (Make - Bajaj/Crompton/Phillips)
S&F 9 W LED light fitting wall mounted batten 2ft , extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 9 watt , 6000K including necessary connection complete all as specified and directed.
S&F epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door, vertical type, including upto 250A MCCB incomer (when MCBs to be used), Vertical Triple pole and neutral 415 V, 12 ways with mounting fitted with bus bar, DIN channel , MCBs, neutral link and incoming contact complete all as directed.
S&F MCCB TPN 125 Amps, 25kA, 240 Volts,ISI marked and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCB SP 40 to 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCB SPN 6 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCB SPN 40 to 43 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
S&F Ceiling fan of capacity 1200 mm, 240 volts, ISI mark, BEE rated 5 star.
S&F Ceiling fan of capacity 1400 mm, 240 volts, ISI mark, BEE rated 5 star.
S&F portable shadow less light(moblie), OT light as per specification Model No : HOSPI CT M5 Hex Blue all as specified and directed. (a) Intensity : 150000 Lux (b) Spolt Diameter : 100-150mm (c) Depth illumination : 10-15mm (d) Colour Temp : 4300-5200K (e) Focusing : Adjustable (f) Nos of LED : 95 (g) Diameter of light : 650mm (h) Power Supply : 220V/50Hz AC Driven by DC 24Volts (j) Power Consumption : 100 Watts (k) Battery Backup : Upto 30 Mins (l) Special function : Remote operated
S&F ceiling mounted OT light as per specification Model No : HOSPI CT 5 APPLE all as specified and directed. (a) Intensity : 160000 Lux (b) Clour rendering index : 95 (c) Depth illumination ;10-25mm (d) Colour Temp : 3500-5200K (e) Focusing : Adjustable by handle (f) Nos of LED : 90+90 (g) Power Supply : 220V/50Hz AC Driven by DC 24Volts (h) Battery Backup : Upto 30 Mins
S&F Power backup UPS of Capacity 3000 VA,Model No: Microtek UPS JM SW 3000VA/24V or equivalent make complete all as specified and directed.
S&F Heavy duty Power backup UPS of Capacity 5500 VA, Model No : Microtek UPS JM SW 5500 VA/48V or equivalent make complete all as specified and directed.
S&F Tall tubler battery 12V 165 AH with complete assy complete all as specified and directed.
S&F PVC body UPS cabinet large size complete all as specified and directed.
S&F submain two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC casing and caping (ISI marked) including 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified.
ANIMA ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .